All three models are CHAMPIGNON PNOZ X2 compact basic safety relays, appartenant à la série PILZ classic X. Ils sont conçus pour la surveillance des circuits de sécurité des équipements industriels, mainly overseeing safety components such as emergency stop buttons, safety gates, safety light curtains and two-hand control units. The three products feature identical contact configuration, functions and dimensions, differing only in supply voltage. Equipped with standard automatic reset and dual-channel safety design, they comply with machinery safety standards Cat.3 / PLd / SIL 2.
- Explication du code modèle
1.1 General Rules for Brand & Série
CHAMPIGNON: Marque (a German professional safety automation manufacturer)
772140 / 772142 / 772143: Unique factory part numbers of PILZ
PNOZ: Main series code for PILZ safety relays
X: X Series – Compact general-purpose safety relays, DIN rail mounted, cost-effective basic type
2: Contact configuration code – 2 sets of force-guided safety normally open (NON) contacts
1.2 Model Correspondence Table
| Factory Part No. | Modèle complet | Tension d'alimentation | Différence clé |
| 772140 | PNOZ X2 24V AC/DC | 24V CA/CC | Most widely used in industrial control, compatible with DC systems for PLCs and sensors |
| 772142 | PNOZ X2 110V AC | 110V et | Suited for Japanese-style equipment and power supply systems in some overseas regions |
| 772143 | PNOZ X2 230V AC | 230V et | Matches domestic industrial mains power and European standard AC systems |
Note: All three models adopt automatic reset without manual reset function. Built-in dual-channel safety detection and force-guided contacts (core safety structure of safety relays to prevent failure caused by contact welding).
- Spécifications techniques de base
Except for supply voltage, all electrical, mechanical and safety parameters are identical for the three models, as summarized below:
| Catégorie | Article | Caractéristiques | Remarques |
| Basic Properties | Type de produit | Dual-channel Safety Relay | Dual-channel monitoring for safety circuits, compliant with machinery safety regulations |
| Safety Contacts | 2 × Force-guided Normally Open (NON) Contacts | Pas de contacts auxiliaires, pure safety output | |
| Mode de réinitialisation | Réinitialisation automatique | Automatically restarts after safety circuit recovers, no manual button required | |
| Montage | Standard 35mm DIN Rail Mount | Universal installation for control cabinets | |
| Protection contre la pénétration | IP40 | For indoor cabinet use; étanche à la poussière, not resistant to water splashing | |
| Paramètres électriques | Tension de fonctionnement nominale | 772140: 24V CA/CC | Coil supply voltage |
| 772142: 110V et | |||
| 772143: 230V et | |||
| Rated Contact Load AC-15 | 230V / 6UN | Applicable to resistive and inductive loads | |
| Rated Contact Load DC-13 | 24V / 6UN | Load capacity for DC circuits | |
| Max.. Switching Voltage | 250V et / 30À DC | Upper voltage limit for output circuits | |
| Typical Response Time | <20 ms | Fast safety actuation to ensure reliable emergency stop | |
| Consommation d'énergie | Environ. 2.5W | Faible perte de puissance, low heat generation during long-term operation | |
| Paramètres environnementaux | Température de fonctionnement | 0℃ ~ +55℃ | Standard industrial control environment |
| Température de stockage | -25℃ ~ +70℃ | Temperature range for storage and transportation | |
| Humidité relative | 10% ~ 90% (Sans condensation) | Condensation and frost are prohibited | |
| Safety Ratings | Machinery Safety Category | Cat. 3 | Compliant with EN ISO 13849-1 |
| Niveau de performance | PLd | Standard safety level for mainstream automated equipment | |
| Niveau d'intégrité de la sécurité | SIL 2 | Conforme à la CEI 61508 functional safety standard | |
| Certifications | Approvals | TUV, CE, cULus | Globally recognized industrial certifications, eligible for export |
| Physique & Câblage | Dimensions (L × H × P) | 22.5 × 94 × 120 mm | Narrow compact design, économise de l'espace dans l'armoire |
| Type de connexion | Bornes à vis | Reliable wiring, suitable for environments with mechanical vibration | |
| Poids | Environ. 140 g | Lightweight rail-mounted module |
- Full Range List (PNOZ X2 Family)
Same structure and contact configuration; differentiated only by voltage and reset mode for convenient replacement and selection:
| Numéro de pièce. | Modèle complet | Tension d'alimentation | Mode de réinitialisation | Description |
| 772140 | PNOZ X2 24V AC/DC | 24V CA/CC | Réinitialisation automatique | Mainstream standard model |
| 772141 | PNOZ X2 48V AC | 48V et | Réinitialisation automatique | Special low-volume voltage version |
| 772142 | PNOZ X2 110V AC | 110V et | Réinitialisation automatique | For 110V AC power systems |
| 772143 | PNOZ X2 230V AC | 230V et | Réinitialisation automatique | For 220/230V mains systems |
| 772100 | PNOZ X2 24V AC/DC | 24V CA/CC | Réinitialisation manuelle | Requires external reset button for high-safety applications |
Extended: Main Related Models of PNOZ X Series
| Modèle | Configuration des contacts | Poste de candidature |
| PNOZ X1 | 1 Safety Normally Open Contact | Basic single safety circuit monitoring |
| PNOZ X3 | 3 Safety Normally Open + 1 Auxiliary Normally Closed Contact | Multiple output circuits with signal feedback |
| PNOZ X4 | 4 Safety Normally Open Contacts | Synchronous cut-off for multiple loads |
- Cross-Generation & Remplacement entre marques
4.1 Internal Replacement within PILZ
Statut du produit: 772140/772142/772143 (PNOZX2) are active mass-production models, no obsolescence or direct discontinued replacements.
Upgraded Alternatives (Des performances supérieures, rétrocompatible):
PNOZ X2.8P: Equipped with diagnostic output and optimized terminals; pin-compatible for direct replacement.
PNOZ X3: Recommended if additional auxiliary feedback contacts are required.
Downgraded Replacement: Not available. PNOZ X2 is the entry-level model of X series.
4.2 Équivalents multimarques (Same Safety Rating: Cat.3 / PLd)
| Marque | Modèle | Tension d'alimentation | Configuration des contacts | Remarque sur la compatibilité |
| Schmersal | SRB 301ST | 24V/110V/230V | 2 NO Safety Contacts | Identical function and rating, similar wiring logic |
| SIEMENS | 3TK2821 | 24V CA/CC / 230V et | 2 NO Safety Contacts | Popular German alternative, universal DIN rail mounting |
| Schneider Électrique | XPSAC01 | 24V/230V | 2 NO Safety Contacts | Preferred for cabinets with Schneider components |
| ABB | JSBR4 | 24V/230V | 2 NO Safety Contacts | Widely used for European and American projects |
| Weidmüller | SAFE-SR2 | 24V CA/CC | 2 NON | Cost-effective option for domestic control cabinets |
Important Reminder: Always verify wiring diagrams and safety circuit logic when replacing safety components. Do not replace merely based on appearance to avoid safety hazards.
4.3 Alternatives nationales
Modèles recommandés: IDEC HR1S, Tianyi safety relays
Scénarios applicables: Non-high-risk equipment and ordinary domestic automated production lines
Restrictions: Not recommended for high-end export equipment, robotic systems, presses and stamping machines.
- Environnements d'applications & Cas industriels
5.1 Principaux scénarios d'application
This universal safety relay is used for industrial equipment requiring safe power circuit cut-off. Typical monitored components:
- Emergency stop circuit (full equipment emergency shutdown)
- Mechanical safety gates and guard switches (power cut-off once gates are opened)
- Safety light curtains and area scanners (shutdown protection when personnel enter hazardous areas)
- Two-hand control buttons (prevent misoperation on pressing and riveting machines)
- Safety limit switches and travel safety contacts
5.2 Applicable Industries
Machine Tool Processing: Tours, fraiseuses, centres d'usinage, broyeurs
Conditionnement & Logistique: Machines d'emballage, palletizers, convoyeurs, matériel de tri
Fabrication automobile: Soudage, assembly and coating production lines
Caoutchouc & Plastic Injection: Presses à injecter, extrudeuses, die-cutting equipment
Automatisation générale: Robotic workstations, custom automated machinery
Machines pour l'industrie légère: Impression, textile and food processing equipment
5.3 Suitable Operating Conditions
Standard indoor control cabinets, normal temperature, dust-free or slightly dusty environments
Conventional power frequency systems (24V/110V/230V power supply)
Circuits with frequent start-stop and demand for rapid safety cut-off
5.4 Scénarios non recommandés (Précautions)
- Explosion-proof Areas: Pas de certification antidéflagrante. Use dedicated PILZ explosion-proof safety relays for explosive workshops.
- Outdoor Exposure / High Humidity & Condensation: IP40 protection is insufficient; an additional protective enclosure is required.
- Severe Electromagnetic Interference: (Near high-frequency welders or large inverters) Shielding measures and independent earthing are necessary.
- Overload Operation: Contact current must not exceed 6A. Add intermediate contactors for high-power loads.
- Ambient Temperature above 55℃: Will shorten service life of safety contacts and cause false tripping.
5.5 Cas d'application typiques
Cas 1: Safety Protection for Vertical Machining Center
Configuration: 772140 (24V CA/CC) + Safety gate switch + Emergency stop button
Fonction: Opening the equipment guard gate → Safety relay actuates → Cuts off power to spindle and feed motors; Automatic reset and restart after gate closure.
Avantages: Complies with machine safety standards and prevents personnel from entering mechanical hazardous zones.
Cas 2: Food Flow Wrapper
Configuration: 772143 (230V et) + Safety light curtain
Fonction: If operators accidentally reach into the operating area → Light curtain triggers → Relay cuts off main drive power.
Avantages: IP40 rating adapts to slight water vapor in workshops; automatic reset ensures continuous production.
- Guide de sélection des modèles
Règles de référence rapide
- The three part numbers differ only in coil voltage, with identical appearance, contacts and functions:
772140 = 24V AC/DC (Universel, first choice)
772142 = 110V AC (For Japanese-style and overseas equipment)
772143 = 230V AC (For domestic 220V mains power)
- PNOZ X2 = 2 safety NO contacts + Réinitialisation automatique
- Selection Priority: Confirm control cabinet supply voltage first, then verify reset mode (automatique / manuel).
- Dépannage
| Phénomène de défaut | Probable Cause | Solution |
| Indicateur d'alimentation éteint, no response | Broken coil wiring, loose terminals, power failure | Mesurer la tension d'entrée, tighten screws, check upstream circuit breakers and fuses |
| Faux déclenchements fréquents | Loose wiring in safety circuit, electromagnetic interference, poor contact of gate switches | Re-crimp terminals, route cables away from power lines, replace worn safety switches |
| Safety circuit normal but relay fails to energize | Aged internal contacts, damaged coil, end of service life | Replace with an identical safety relay (Safety components are not repairable) |
| Output contacts cannot open (welded) | Surcharge à long terme, court-circuit de charge, frequent high-current surges | Remplacer le relais; add intermediate contactors for current division; never exceed 6A rated current |
| Abnormal reset, failed automatic restart | Incomplete closure of safety circuit, line short to ground | Check continuity of the entire safety circuit and eliminate short circuits |
Safety Regulation: Faulty safety relays are prohibited from disassembly and repair. The complete unit must be replaced.
- Commande, Conditionnement & Conformité
8.1 Ordering Details
| Factory Part No. | Modèle complet | Tension d'alimentation | Standard Packaging |
| 772140 | PNOZ X2 24V AC/DC | 24V CA/CC | 1 unité par boîte |
| 772142 | PNOZ X2 110V AC | 110V et | 1 unité par boîte |
| 772143 | PNOZ X2 230V AC | 230V et | 1 unité par boîte |
8.2 Commercial & Storage Information
Quantité minimum de commande: 1 morceau
Origine: Allemagne (Original PILZ product)
Spare Parts Suggestion: Prepare 1 unit of corresponding voltage model for every 10 sets of similar equipment
Statut du produit: Mass production, long-term stable supply
8.3 Logistics Compliance
No lithium batteries, supercapacitors or hazardous materials inside. Classified as general low-voltage electrical component.
No special restrictions for air, transport maritime et terrestre; no additional dangerous goods declaration required.
8.4 Normes & Approvals
Normes applicables: EN ISO 13849-1, CEI 61508, DANS 60947-5-1
Certifications: CE, TUV, UL. Approved for use in EU, North America and most regions worldwide.
- Supplémentaire: Basic Wiring Instructions
- Coil Power Supply: Apply corresponding rated voltage to coil terminals (A1/A2).
- Safety Input Circuit: Wire emergency stop buttons and safety gates in series to dual-channel inputs.
- Safety Output Circuit: Connect 2 sets of NO safety contacts in series to the control circuit of main contactors.
- Principe de câblage: Adopt series connection for safety circuits. The relay will immediately cut off outputs once any safety component opens.
Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

















NH42-63-318x560.png)