Schneider EOCRSSD-30S Digital Motor Protector

Model Code Interpretation Code Segment Description EOCR Series logo, motor protection relay series under Schneider (Former SAMWHA Korea) SS Basic series code, economical electronic overcurrent relay platform D Function upgrade code, Version à affichage numérique, different from LED indicator type of traditional SS series 30 Current specification code, rated protection current range: 3-30UN, built-in through-type CT for ...

  • Détails du produit

Interprétation du code modèle

Segment de codeDescription
EOCRSeries logo, motor protection relay series under Schneider (Former SAMWHA Korea)
SSBasic series code, economical electronic overcurrent relay platform
DFunction upgrade code, Version à affichage numérique, different from LED indicator type of traditional SS series
30Current specification code, rated protection current range: 3-30UN, built-in through-type CT for direct wiring
SControl power supply code: universal wide voltage 24-240V AC/DC; Type W is dedicated for 380-440V AC

Positionnement de base:

EOCRSSD-30S is a compact digital comprehensive motor protection relay, featuring three core protections: surcharge, phase loss and stall. It is applicable for motors with current 3-30A and compatible with 24-240V wide-voltage control power supply.

  1. Paramètres de spécification de base
CatégorieSpécifications détailléesRemarques
Paramètres de base
Numéro de commandeEOCRSSD-30S (Schneider SKU: 0015874)Standard universal model worldwide
Type de protectionElectronic overcurrent relay / Motor protectorReplace combination of traditional thermal relay and ammeter
Installation35mm Montage sur rail DIN / Panel mountingStructure compacte, gain de place
Dimension (L×H×P)56mm×78mm×120mmFully compatible with installation size of EOCR-SS series
Température de fonctionnement-20℃ ~ 60℃Adapt to temperature difference changes in industrial environment
Spécifications électriques
Current Protection Range3-30UN (direct wiring)External CT is required for current over 60A
Control Power Supply24-240V CA/CC (50/60Hz)Conception à large tension, fit for various control systems
Working Frequency50/60HzUniversal power frequency for global use
Output Contacts1NON + 1NC passive contacts95-96 (Caroline du Nord), 97-98 (NON)
Capacité de contactC.A. 250 V/5 A, DC 30V/5AMeet demands of conventional control circuits
Fonctions de protection
Protection contre les surchargesRéglable (0.1~100s), support I²t inverse time characteristicSet via O-TIME parameter
Protection contre la perte de phaseQuick action within 4 secondesTrigger when three-phase unbalance degree>20%
Stall ProtectionAdjustable startup delay (D-TIME), minimum 0.2s quick trippingSuitable for instantaneous protection during motor startup
Fonction d'affichage7-segment LED digital tubeReal-time display of operating current and fault code
Mode de réinitialisationRéinitialisation manuelle (RESET button) / Electric resetEasy recovery after troubleshooting
Précision & Fiabilité
Measuring Accuracy±1%Higher than traditional thermal relay (±10%)
Temps de réponseMin.. 0.2s (stall protection)Effectively prevent motor damage
Fault RecordCheck the latest 3 enregistrements de défautsConvenient for quick fault location
Classe d'isolationClasse IIHigh safety protection level
  1. Défauts courants & Maintenance Solutions

3.1 Codes d'erreur & Dépannage

Code d'erreurType de défautCauses possiblesSolutions
O-COverload Tripping1. Excessive motor load1. Check load and eliminate mechanical jamming
2. Too small O-TIME setting2. Appropriately increase O-TIME value
3. Abnormal power supply voltage3. Measure three-phase voltage to ensure balance
P-PPhase Loss / Open Phase1. Broken or loose power wire1. Check circuit connection and fasten terminals
2. Burned contactor contacts2. Replace faulty contactor contacts
3. Motor winding failure3. Measure insulation resistance of motor winding
S-CStall / Blockage1. Instant stall during motor startup1. Inspect mechanical transmission system
2. Too short D-TIME setting2. Appropriately extend D-TIME value
3. Stuck mechanical load3. Remove load jamming failure
Aucun affichagePanne de courant1. Control power disconnected1. Check power wiring
2. Power voltage out of range2. Measure input voltage (24-240V)
3. Blown internal fuse3. Replace internal fuse
Abnormal DisplayElectromagnetic Interference1. Close to high-power inverter / electric welder1. Keep away from interference sources or add shielding measures
2. Câblage lâche2. Inspect and fasten all wiring
3. Firmware error3. Restore device to factory settings

3.2 Daily Maintenance Schedule

Cycle d'entretienMaintenance ItemsPoints d'opération
Tous les joursInspection visuelleClean panel and heat dissipation holes, check normal LED display
HebdomadaireInspection du câblageCheck loose terminals and oxidation phenomenon
MensuelParameter VerificationConfirm O-TIME and D-TIME conform to motor rated values
TrimestrielTest de fonctionnementSimulate overload and phase loss faults to verify protection accuracy
AnnuelComprehensive InspectionCheck aging of internal components, update firmware if necessary
  1. Full EOCRSSD Series Model List

The EOCRSSD series has 3 basic models covering current range 0.5-60A to meet protection demands of motors with different power.

ModèleCurrent Protection RangeControl Power SupplyPrincipales caractéristiquesPuissance moteur applicable (380V)
EOCRSSD-05S0.5-6UN24-240V CA/CCSpecial for low current, direct wiring0.18-3kW
EOCRSSD-30S3-30UN24-240V CA/CCGeneral medium current type, direct wiring1.5-15kW
EOCRSSD-60S5-60UN24-240V CA/CCGeneral high current type, direct wiring (External CT required above 60A)3-30kW

Note: The whole series supports overload, phase loss and stall protection; independent adjustable startup delay (D-Time) and overload action time (O-Time); LED digital display for operating current and fault causes.

  1. Cross-brand Product Comparison
Comparison ItemsSchneider EOCRSSD-30SSiemens 3RB2026-1KB0ABB CM-MSS.61SOmron K8DS-PH1
Plage actuelle3-30UN2.5-32UN0.1-40UN3-30UN
Control Power Supply24-240V CA/CC24-240V CA/CC24-240V CA/CC24-240V CA/CC
Fonctions de protectionSurcharge, Phase Loss, StallSurcharge, Phase Loss, StallSurcharge, Phase Loss, Stall, Phase UnbalanceSurcharge, Phase Loss, Stall
Mode d'affichage7-segment LED digital tubeLED indicator lightDigital displayLED indicator light
Output Contacts1NON+1NC1NON+1NC1NON+1NC1NON+1NC
Accuracy Grade±1%±2%±1%±2%
Taille d'installation56×78×120mm55×78×118mm56×78×120mm55×78×118mm
Gamme de prixMoyen (À propos 370 RMB)Haut (À propos 500 RMB)Haut (À propos 480 RMB)Moyen (À propos 350 RMB)
Avantages principauxIntuitive digital display, fault record, 1:1 replacement for SS seriesBrand premium, excellent system integrationPhase unbalance protection, haute précisionRentable, fast response speed
  1. Conformité des expéditions aériennes & Certification Information

6.1 Air Shipment Compliance Judgment

Product Category: Electrical and electronic equipment (No built-in lithium battery / super capacitor)

UN Number: Non requis (Marchandises non dangereuses)

Shipping Restrictions: No special restrictions, deliver as general cargo

Packaging Requirement: Adopt anti-static packaging to avoid static damage to internal components during transportation

6.2 Certification Information

Certification TypeCertification StandardPortée applicableKey Requirements
Certification CEDANS 60947-4-1 (Sécurité électrique)EU MarketComply with Low Voltage Directive (LVD) and EMC Directive
DANS 61000-6-2 (EMC Immunity)
Certification ULUL 508 (Industrial Control Equipment)North America MarketMeet North American electrical safety standards
CSA CertificationCSA C22.2 No.14 (Control Equipment)Canada MarketConform to Canadian safety standards
IEC CertificationCEI 60947-4-1Global MarketComply with standards of International Electrotechnical Commission

Note: CE marks and certification numbers are marked on product body and outer package. Technical documents shall include test reports, risk assessment reports and Declaration of Conformity (DoC), which shall be kept for at least 10 années.

  1. Selection Formula & Quick Memorization Rules

7.1 Selection Formula

Calculate motor current first, match EOCRSSD properly;

05 stands for 0.5-6A, 30 covers 3-30A;

60 reaches 60A, match external CT for higher current;

Select S/W according to control power, S means 24-240 tension large;

Three core protections: surcharge, phase loss and stall;

Easy fault checking via digital display, convenient DIN rail installation.

7.2 Quick Memorization Rules

Correspondance actuelle: Rated motor current shall be within 30%-80% of protector range, avoid boundary value affecting accuracy

Voltage Selection: Prioritize Type S (24-240V CA/CC) control power for stronger compatibility

Paramétrage:

O-TIME: Ensemble 10-20 seconds when current is 1.2 times motor rated current

D-TIME: Set as motor startup time plus 2 secondes

Replacement Rule: Realize 1:1 direct replacement for traditional EOCR-SS series and thermal relays without changing installation size and wiring

  1. En vigueur & Inapplicable Scenarios

Scénarios applicables

  1. General Industrial Motors: Protection for water pumps, les fans, compressors and other common equipment
  2. Small Production Lines: Single motor control loop requiring visualized fault display
  3. Renovation Projects: Replace traditional thermal relays to improve protection precision and convenience
  4. Harsh Working Environment: Temperature range -20℃~60℃, suitable for most industrial sites
  5. Multi-voltage System: 24-240V wide voltage adaptation, fit for transnational equipment and complex power supply environment

Inapplicable Scenarios

  1. High-precision Control: Intelligent control system needing 4-20mA analog output or communication function (Recommend EOCR-E series)
  2. Extra-high Current Motor: Current over 60A without space for external CT installation (Recommend EOCR-3DM2 series)
  3. Special Protection Demand: Occasions requiring earth protection, leakage protection or phase sequence protection (Recommend EOCR-DS1 series)
  4. Explosion-proof Environment: Hazardous areas needing explosion-proof certification (Choose dedicated explosion-proof protectors)

Full Series Model List of Schneider EOCR Digital Motor Protectors

  1. Series Classification Overview

Schneider EOCR digital motor protectors are divided into three categories by function positioning: Type économique, Multifunctional Digital Type and Intelligent Type, covering current range 0.5-800A to meet various industrial demands.

  1. Economical Digital Protectors (EOCR-SS/SSD Series)

2.1 EOCR-SS Series (Indications LED)

ModèlePlage actuellePuissance de contrôleNuméro de commande.Fonctionnalités principalesApplicable Power (380V)
EOCR-SS05S0.5-6UN24-240V CA/CC15872Overload/Phase Loss/Stall protection, Indications LED0.18-3kW
EOCR-SS30S3-30UN24-240V CA/CC15873Same protection functions1.5-15kW
EOCR-SS60S5-60UN24-240V CA/CC15874Same protection functions3-30kW
EOCR-SS05W0.5-6UN380-440V et15875Dedicated 380V control power0.18-3kW
EOCR-SS30W3-30UN380-440V et15876Dedicated 380V control power1.5-15kW
EOCR-SS60W5-60UN380-440V et15877Dedicated 380V control power3-30kW

2.2 EOCR-SSD Series (Digital Display Upgraded Version)

ModèlePlage actuellePuissance de contrôleNuméro de commande.Fonctionnalités principalesApplicable Power (380V)
EOCRSSD-05S0.5-6UN24-240V CA/CC15878Dual digital & LED display, fault record, inverter optimized0.18-3kW
EOCRSSD-30S3-30UN24-240V CA/CC15879Same functions1.5-15kW
EOCRSSD-60S5-60UN24-240V CA/CC15880Same functions3-30kW
EOCRSSD-05W0.5-6UN380-440V et15881380V dedicated, dual display0.18-3kW
EOCRSSD-30W3-30UN380-440V et15882380V dedicated, dual display1.5-15kW
EOCRSSD-60W5-60UN380-440V et15883380V dedicated, dual display3-30kW
  1. Multifunctional Digital Protectors (EOCR-E Series)

3.1 EOCR-3DE/FDE Series (Basic Digital Type)

ModèlePlage actuellePuissance de contrôleType de câblageFonctionnalités principalesScénarios applicables
EOCR-3DE-050.5-6UN24-240V CA/CCWindow typeOverload/Phase Loss/Stall/Reverse Phase/Unbalance protection, pre-alarmGeneral industrial motors
EOCR-3DE-303-30UN24-240V CA/CCWindow typeSame functionsGeneral industrial motors
EOCR-3DE-605-60UN24-240V CA/CCWindow typeSame functionsGeneral industrial motors
EOCR-FDE-050.5-6UN24-240V CA/CCFeed-through typeSame as 3DE series with different wiringSpace-limited installation
EOCR-FDE-303-30UN24-240V CA/CCFeed-through typeSame as 3DE series with different wiringSpace-limited installation
EOCR-FDE-605-60UN24-240V CA/CCFeed-through typeSame as 3DE series with different wiringSpace-limited installation

3.2 EOCR-3EZ/FEZ Series (With Earth Fault Protection)

ModèlePlage actuellePuissance de contrôleType de câblageFonctionnalités principalesScénarios applicables
EOCR-3EZ-050.5-6UN24-240V CA/CCWindow type3DE full functions + adjustable earth fault protection (30mA-1A)Equipment requiring earth protection
EOCR-3EZ-303-30UN24-240V CA/CCWindow typeSame functionsEquipment requiring earth protection
EOCR-3EZ-805-80UN24-240V CA/CCWindow typeSame functionsEquipment requiring earth protection
EOCR-FEZ-050.5-6UN24-240V CA/CCFeed-through typeSame as 3EZ seriesSpace-limited installation + earth protection
EOCR-FEZ-303-30UN24-240V CA/CCFeed-through typeSame as 3EZ seriesSpace-limited installation + earth protection
EOCR-FEZ-805-80UN24-240V CA/CCFeed-through typeSame as 3EZ seriesSpace-limited installation + earth protection

3.3 EOCR-3E420/FE420 Series (With 4-20mA Output)

ModèlePlage actuellePuissance de contrôleType de câblageFonctionnalités principalesScénarios applicables
EOCR-3E420-050.5-6UN24-240V CA/CCWindow type3DE functions + 4-20mA analog outputRemote monitoring system
EOCR-3E420-303-30UN24-240V CA/CCWindow typeSame functionsRemote monitoring system
EOCR-3E420-605-60UN24-240V CA/CCWindow typeSame functionsRemote monitoring system
EOCR-FE420-050.5-6UN24-240V CA/CCFeed-through typeSame as 3E420 seriesSpace-limited + surveillance à distance
EOCR-FE420-303-30UN24-240V CA/CCFeed-through typeSame as 3E420 seriesSpace-limited + surveillance à distance
EOCR-FE420-605-60UN24-240V CA/CCFeed-through typeSame as 3E420 seriesSpace-limited + surveillance à distance
  1. Intelligent Protectors (EOCR-3DM2/FDM2/3MZ2 Series)

4.1 EOCR-3DM2 Series (Window Type)

ModèlePlage actuellePuissance de contrôleFonctionnalités principalesFonction de communicationScénarios applicables
EOCR-3DM2-WRDB0.5-80UN24À DCProtection complète + affichage numérique + fault record + load selectionRS-485 ModbusDC control system
EOCR-3DM2-WRDU0.5-80UN100-240V CA/CCProtection complète + affichage numérique + fault record + load selectionRS-485 ModbusCA & DC universal system
EOCR-3DM2-WRDBHZ0.5-80UN24À DCWith harmonic suppression functionRS-485 ModbusFrequency conversion drive system
EOCR-3DM2-WRDUHZ0.5-80UN100-240V CA/CCWith harmonic suppression functionRS-485 ModbusFrequency conversion drive system

4.2 EOCR-FDM2 Series (Feed-through Type)

ModèlePlage actuellePuissance de contrôleFonctionnalités principalesFonction de communicationScénarios applicables
EOCR-FDM2-FRDB0.5-80UN24À DCProtection complète + affichage numérique + fault record + load selectionRS-485 ModbusDC control system
EOCR-FDM2-FRDU0.5-80UN100-240V CA/CCProtection complète + affichage numérique + fault record + load selectionRS-485 ModbusCA & DC universal system
EOCR-FDM2-FRDBHZ0.5-80UN24À DCWith harmonic suppression functionRS-485 ModbusFrequency conversion drive system
EOCR-FDM2-FRDUHZ0.5-80UN100-240V CA/CCWith harmonic suppression functionRS-485 ModbusFrequency conversion drive system

4.3 EOCR-3MZ2 Series (Type de borne, External CT Required)

ModèlePlage actuellePuissance de contrôleFonctionnalités principalesFonction de communicationScénarios applicables
EOCR-3MZ2-TRDB0.5-800UN (External CT)24À DCProtection complète + affichage numérique + fault record + load selectionRS-485 ModbusHigh current motor
EOCR-3MZ2-TRDU0.5-800UN (External CT)100-240V CA/CCProtection complète + affichage numérique + fault record + load selectionRS-485 ModbusHigh current motor
EOCR-3MZ2-TRDBHZ0.5-800UN (External CT)24À DCWith harmonic suppression functionRS-485 ModbusHigh current frequency conversion motor
EOCR-3MZ2-TRDUHZ0.5-800UN (External CT)100-240V CA/CCWith harmonic suppression functionRS-485 ModbusHigh current frequency conversion motor
  1. Special Function Protectors

5.1 EOCR-DS/DS3 Series (Economical Digital Display Type)

ModèlePlage actuellePuissance de contrôleFonctionnalités principalesScénarios applicables
EOCRDS-05S0.5-6UN24-240V CA/CCOverload/Phase Loss/Stall protection, affichage numériqueBasic digital display demand
EOCRDS-30S3-30UN24-240V CA/CCOverload/Phase Loss/Stall protection, affichage numériqueBasic digital display demand
EOCRDS-60S5-60UN24-240V CA/CCOverload/Phase Loss/Stall protection, affichage numériqueBasic digital display demand
EOCRDS3-05S0.5-6UN24-240V CA/CCUpgraded version with additional phase unbalance protectionBasic display + unbalance protection
EOCRDS3-30S3-30UN24-240V CA/CCUpgraded version with additional phase unbalance protectionBasic display + unbalance protection
EOCRDS3-60S5-60UN24-240V CA/CCUpgraded version with additional phase unbalance protectionBasic display + unbalance protection

5.2 EOCR-PMZ/PFZ Series (Power Monitoring Type)

ModèlePlage actuellePuissance de contrôleFonctionnalités principalesFonction de communicationScénarios applicables
EOCR-PMZ-050.5-6UN24-240V CA/CCProtection complète + power monitoring + energy meteringRS-485 ModbusEnergy consumption monitoring system
EOCR-PMZ-303-30UN24-240V CA/CCProtection complète + power monitoring + energy meteringRS-485 ModbusEnergy consumption monitoring system
EOCR-PMZ-805-80UN24-240V CA/CCProtection complète + power monitoring + energy meteringRS-485 ModbusEnergy consumption monitoring system
EOCR-PFZ-050.5-6UN24-240V CA/CCFeed-through type, same functions as PMZ seriesRS-485 ModbusEnergy monitoring + espace limité
EOCR-PFZ-303-30UN24-240V CA/CCFeed-through type, same functions as PMZ seriesRS-485 ModbusEnergy monitoring + espace limité
EOCR-PFZ-805-80UN24-240V CA/CCFeed-through type, same functions as PMZ seriesRS-485 ModbusEnergy monitoring + espace limité

5.3 EOCR-DGT Series (Type de protection contre les fuites)

ModèlePlage actuellePlage de protection contre les fuitesPuissance de contrôleFonctionnalités principalesScénarios applicables
EOCR-DGT-050.5-6UN30mA-1A24-240V CA/CCFuite + Surcharge + Phase Loss + Reverse Phase + Unbalance protectionEquipment in humid environment
EOCR-DGT-303-30UN30mA-1A24-240V CA/CCFull combined protectionEquipment in humid environment
EOCR-DGT-605-60UN30mA-1A24-240V CA/CCFull combined protectionEquipment in humid environment
EOCR-DGT-805-80UN30mA-1A24-240V CA/CCFull combined protectionEquipment in humid environment
  1. Quick Memorization of Model Naming Rules
  2. Préfixe: EOCR= Schneider motor protection relay series mark
  3. Code de série:

SS/SSD: Economical type (SSD with digital display)

3DE/FDE/3EZ/FEZ/3E420/FE420: Multifunctional digital type

3DM2/FDM2/3MZ2: Intelligent type (3MZ2 needs external CT)

DS/DS3: Simple digital display type

PMZ/PFZ: Power monitoring type

DGT: Leakage protection type

  1. Code actuel: 05(0.5-6UN), 30(3-30UN), 60(5-60UN), 80(5-80UN)
  2. Power Supply Code: S(24-240V CA/CC), W(380V et), B(24VCC), U(100-240V CA/CC)
  3. Mode de câblage: W(Window), F(Feed-through), T(Type de borne)
  4. Special Function: HZ(Harmonic suppression), 420(4-20mA output)
  5. Quick Selection Table by Functional Demand
Functional DemandSérie recommandéeAvantages principauxMax Current
Protection de base & faible coûtEOCR-SS/SSDRentable, installation facile60UN
Protection de base + affichage numériqueEOCRSSD/DSVisualized fault checking60UN
Protection complète + earth fault protectionEOCR-3EZ/FEZAnti-leakage, high safety level80UN
Surveillance à distance + analog signalEOCR-3E420/FE4204-20mA signal output, easy system integration60UN
Intelligent control + communicationEOCR-3DM2/FDM2Modbus remote control80UN
High current motor protectionEOCR-3MZ2Match external CT, cover 0.5-800A800UN
Energy consumption monitoring + protectionEOCR-PMZ/PFZPower statistics and energy-saving analysis80UN
Leakage protection + full combined protectionEOCR-DGTProtection intégrée contre les fuites80UN