Interprétation du code modèle
| Segment de code | Description |
| EOCR | Series logo, motor protection relay series under Schneider (Former SAMWHA Korea) |
| SS | Basic series code, economical electronic overcurrent relay platform |
| D | Function upgrade code, Version à affichage numérique, different from LED indicator type of traditional SS series |
| 30 | Current specification code, rated protection current range: 3-30UN, built-in through-type CT for direct wiring |
| S | Control power supply code: universal wide voltage 24-240V AC/DC; Type W is dedicated for 380-440V AC |
Positionnement de base:
EOCRSSD-30S is a compact digital comprehensive motor protection relay, featuring three core protections: surcharge, phase loss and stall. It is applicable for motors with current 3-30A and compatible with 24-240V wide-voltage control power supply.
- Paramètres de spécification de base
| Catégorie | Spécifications détaillées | Remarques |
| Paramètres de base | ||
| Numéro de commande | EOCRSSD-30S (Schneider SKU: 0015874) | Standard universal model worldwide |
| Type de protection | Electronic overcurrent relay / Motor protector | Replace combination of traditional thermal relay and ammeter |
| Installation | 35mm Montage sur rail DIN / Panel mounting | Structure compacte, gain de place |
| Dimension (L×H×P) | 56mm×78mm×120mm | Fully compatible with installation size of EOCR-SS series |
| Température de fonctionnement | -20℃ ~ 60℃ | Adapt to temperature difference changes in industrial environment |
| Spécifications électriques | ||
| Current Protection Range | 3-30UN (direct wiring) | External CT is required for current over 60A |
| Control Power Supply | 24-240V CA/CC (50/60Hz) | Conception à large tension, fit for various control systems |
| Working Frequency | 50/60Hz | Universal power frequency for global use |
| Output Contacts | 1NON + 1NC passive contacts | 95-96 (Caroline du Nord), 97-98 (NON) |
| Capacité de contact | C.A. 250 V/5 A, DC 30V/5A | Meet demands of conventional control circuits |
| Fonctions de protection | ||
| Protection contre les surcharges | Réglable (0.1~100s), support I²t inverse time characteristic | Set via O-TIME parameter |
| Protection contre la perte de phase | Quick action within 4 secondes | Trigger when three-phase unbalance degree>20% |
| Stall Protection | Adjustable startup delay (D-TIME), minimum 0.2s quick tripping | Suitable for instantaneous protection during motor startup |
| Fonction d'affichage | 7-segment LED digital tube | Real-time display of operating current and fault code |
| Mode de réinitialisation | Réinitialisation manuelle (RESET button) / Electric reset | Easy recovery after troubleshooting |
| Précision & Fiabilité | ||
| Measuring Accuracy | ±1% | Higher than traditional thermal relay (±10%) |
| Temps de réponse | Min.. 0.2s (stall protection) | Effectively prevent motor damage |
| Fault Record | Check the latest 3 enregistrements de défauts | Convenient for quick fault location |
| Classe d'isolation | Classe II | High safety protection level |
- Défauts courants & Maintenance Solutions
3.1 Codes d'erreur & Dépannage
| Code d'erreur | Type de défaut | Causes possibles | Solutions |
| O-C | Overload Tripping | 1. Excessive motor load | 1. Check load and eliminate mechanical jamming |
| 2. Too small O-TIME setting | 2. Appropriately increase O-TIME value | ||
| 3. Abnormal power supply voltage | 3. Measure three-phase voltage to ensure balance | ||
| P-P | Phase Loss / Open Phase | 1. Broken or loose power wire | 1. Check circuit connection and fasten terminals |
| 2. Burned contactor contacts | 2. Replace faulty contactor contacts | ||
| 3. Motor winding failure | 3. Measure insulation resistance of motor winding | ||
| S-C | Stall / Blockage | 1. Instant stall during motor startup | 1. Inspect mechanical transmission system |
| 2. Too short D-TIME setting | 2. Appropriately extend D-TIME value | ||
| 3. Stuck mechanical load | 3. Remove load jamming failure | ||
| Aucun affichage | Panne de courant | 1. Control power disconnected | 1. Check power wiring |
| 2. Power voltage out of range | 2. Measure input voltage (24-240V) | ||
| 3. Blown internal fuse | 3. Replace internal fuse | ||
| Abnormal Display | Electromagnetic Interference | 1. Close to high-power inverter / electric welder | 1. Keep away from interference sources or add shielding measures |
| 2. Câblage lâche | 2. Inspect and fasten all wiring | ||
| 3. Firmware error | 3. Restore device to factory settings |
3.2 Daily Maintenance Schedule
| Cycle d'entretien | Maintenance Items | Points d'opération |
| Tous les jours | Inspection visuelle | Clean panel and heat dissipation holes, check normal LED display |
| Hebdomadaire | Inspection du câblage | Check loose terminals and oxidation phenomenon |
| Mensuel | Parameter Verification | Confirm O-TIME and D-TIME conform to motor rated values |
| Trimestriel | Test de fonctionnement | Simulate overload and phase loss faults to verify protection accuracy |
| Annuel | Comprehensive Inspection | Check aging of internal components, update firmware if necessary |
- Full EOCRSSD Series Model List
The EOCRSSD series has 3 basic models covering current range 0.5-60A to meet protection demands of motors with different power.
| Modèle | Current Protection Range | Control Power Supply | Principales caractéristiques | Puissance moteur applicable (380V) |
| EOCRSSD-05S | 0.5-6UN | 24-240V CA/CC | Special for low current, direct wiring | 0.18-3kW |
| EOCRSSD-30S | 3-30UN | 24-240V CA/CC | General medium current type, direct wiring | 1.5-15kW |
| EOCRSSD-60S | 5-60UN | 24-240V CA/CC | General high current type, direct wiring (External CT required above 60A) | 3-30kW |
Note: The whole series supports overload, phase loss and stall protection; independent adjustable startup delay (D-Time) and overload action time (O-Time); LED digital display for operating current and fault causes.
- Cross-brand Product Comparison
| Comparison Items | Schneider EOCRSSD-30S | Siemens 3RB2026-1KB0 | ABB CM-MSS.61S | Omron K8DS-PH1 |
| Plage actuelle | 3-30UN | 2.5-32UN | 0.1-40UN | 3-30UN |
| Control Power Supply | 24-240V CA/CC | 24-240V CA/CC | 24-240V CA/CC | 24-240V CA/CC |
| Fonctions de protection | Surcharge, Phase Loss, Stall | Surcharge, Phase Loss, Stall | Surcharge, Phase Loss, Stall, Phase Unbalance | Surcharge, Phase Loss, Stall |
| Mode d'affichage | 7-segment LED digital tube | LED indicator light | Digital display | LED indicator light |
| Output Contacts | 1NON+1NC | 1NON+1NC | 1NON+1NC | 1NON+1NC |
| Accuracy Grade | ±1% | ±2% | ±1% | ±2% |
| Taille d'installation | 56×78×120mm | 55×78×118mm | 56×78×120mm | 55×78×118mm |
| Gamme de prix | Moyen (À propos 370 RMB) | Haut (À propos 500 RMB) | Haut (À propos 480 RMB) | Moyen (À propos 350 RMB) |
| Avantages principaux | Intuitive digital display, fault record, 1:1 replacement for SS series | Brand premium, excellent system integration | Phase unbalance protection, haute précision | Rentable, fast response speed |
- Conformité des expéditions aériennes & Certification Information
6.1 Air Shipment Compliance Judgment
Product Category: Electrical and electronic equipment (No built-in lithium battery / super capacitor)
UN Number: Non requis (Marchandises non dangereuses)
Shipping Restrictions: No special restrictions, deliver as general cargo
Packaging Requirement: Adopt anti-static packaging to avoid static damage to internal components during transportation
6.2 Certification Information
| Certification Type | Certification Standard | Portée applicable | Key Requirements |
| Certification CE | DANS 60947-4-1 (Sécurité électrique) | EU Market | Comply with Low Voltage Directive (LVD) and EMC Directive |
| DANS 61000-6-2 (EMC Immunity) | |||
| Certification UL | UL 508 (Industrial Control Equipment) | North America Market | Meet North American electrical safety standards |
| CSA Certification | CSA C22.2 No.14 (Control Equipment) | Canada Market | Conform to Canadian safety standards |
| IEC Certification | CEI 60947-4-1 | Global Market | Comply with standards of International Electrotechnical Commission |
Note: CE marks and certification numbers are marked on product body and outer package. Technical documents shall include test reports, risk assessment reports and Declaration of Conformity (DoC), which shall be kept for at least 10 années.
- Selection Formula & Quick Memorization Rules
7.1 Selection Formula
Calculate motor current first, match EOCRSSD properly;
05 stands for 0.5-6A, 30 covers 3-30A;
60 reaches 60A, match external CT for higher current;
Select S/W according to control power, S means 24-240 tension large;
Three core protections: surcharge, phase loss and stall;
Easy fault checking via digital display, convenient DIN rail installation.
7.2 Quick Memorization Rules
Correspondance actuelle: Rated motor current shall be within 30%-80% of protector range, avoid boundary value affecting accuracy
Voltage Selection: Prioritize Type S (24-240V CA/CC) control power for stronger compatibility
Paramétrage:
O-TIME: Ensemble 10-20 seconds when current is 1.2 times motor rated current
D-TIME: Set as motor startup time plus 2 secondes
Replacement Rule: Realize 1:1 direct replacement for traditional EOCR-SS series and thermal relays without changing installation size and wiring
- En vigueur & Inapplicable Scenarios
Scénarios applicables
- General Industrial Motors: Protection for water pumps, les fans, compressors and other common equipment
- Small Production Lines: Single motor control loop requiring visualized fault display
- Renovation Projects: Replace traditional thermal relays to improve protection precision and convenience
- Harsh Working Environment: Temperature range -20℃~60℃, suitable for most industrial sites
- Multi-voltage System: 24-240V wide voltage adaptation, fit for transnational equipment and complex power supply environment
Inapplicable Scenarios
- High-precision Control: Intelligent control system needing 4-20mA analog output or communication function (Recommend EOCR-E series)
- Extra-high Current Motor: Current over 60A without space for external CT installation (Recommend EOCR-3DM2 series)
- Special Protection Demand: Occasions requiring earth protection, leakage protection or phase sequence protection (Recommend EOCR-DS1 series)
- Explosion-proof Environment: Hazardous areas needing explosion-proof certification (Choose dedicated explosion-proof protectors)
Full Series Model List of Schneider EOCR Digital Motor Protectors
- Series Classification Overview
Schneider EOCR digital motor protectors are divided into three categories by function positioning: Type économique, Multifunctional Digital Type and Intelligent Type, covering current range 0.5-800A to meet various industrial demands.
- Economical Digital Protectors (EOCR-SS/SSD Series)
2.1 EOCR-SS Series (Indications LED)
| Modèle | Plage actuelle | Puissance de contrôle | Numéro de commande. | Fonctionnalités principales | Applicable Power (380V) |
| EOCR-SS05S | 0.5-6UN | 24-240V CA/CC | 15872 | Overload/Phase Loss/Stall protection, Indications LED | 0.18-3kW |
| EOCR-SS30S | 3-30UN | 24-240V CA/CC | 15873 | Same protection functions | 1.5-15kW |
| EOCR-SS60S | 5-60UN | 24-240V CA/CC | 15874 | Same protection functions | 3-30kW |
| EOCR-SS05W | 0.5-6UN | 380-440V et | 15875 | Dedicated 380V control power | 0.18-3kW |
| EOCR-SS30W | 3-30UN | 380-440V et | 15876 | Dedicated 380V control power | 1.5-15kW |
| EOCR-SS60W | 5-60UN | 380-440V et | 15877 | Dedicated 380V control power | 3-30kW |
2.2 EOCR-SSD Series (Digital Display Upgraded Version)
| Modèle | Plage actuelle | Puissance de contrôle | Numéro de commande. | Fonctionnalités principales | Applicable Power (380V) |
| EOCRSSD-05S | 0.5-6UN | 24-240V CA/CC | 15878 | Dual digital & LED display, fault record, inverter optimized | 0.18-3kW |
| EOCRSSD-30S | 3-30UN | 24-240V CA/CC | 15879 | Same functions | 1.5-15kW |
| EOCRSSD-60S | 5-60UN | 24-240V CA/CC | 15880 | Same functions | 3-30kW |
| EOCRSSD-05W | 0.5-6UN | 380-440V et | 15881 | 380V dedicated, dual display | 0.18-3kW |
| EOCRSSD-30W | 3-30UN | 380-440V et | 15882 | 380V dedicated, dual display | 1.5-15kW |
| EOCRSSD-60W | 5-60UN | 380-440V et | 15883 | 380V dedicated, dual display | 3-30kW |
- Multifunctional Digital Protectors (EOCR-E Series)
3.1 EOCR-3DE/FDE Series (Basic Digital Type)
| Modèle | Plage actuelle | Puissance de contrôle | Type de câblage | Fonctionnalités principales | Scénarios applicables |
| EOCR-3DE-05 | 0.5-6UN | 24-240V CA/CC | Window type | Overload/Phase Loss/Stall/Reverse Phase/Unbalance protection, pre-alarm | General industrial motors |
| EOCR-3DE-30 | 3-30UN | 24-240V CA/CC | Window type | Same functions | General industrial motors |
| EOCR-3DE-60 | 5-60UN | 24-240V CA/CC | Window type | Same functions | General industrial motors |
| EOCR-FDE-05 | 0.5-6UN | 24-240V CA/CC | Feed-through type | Same as 3DE series with different wiring | Space-limited installation |
| EOCR-FDE-30 | 3-30UN | 24-240V CA/CC | Feed-through type | Same as 3DE series with different wiring | Space-limited installation |
| EOCR-FDE-60 | 5-60UN | 24-240V CA/CC | Feed-through type | Same as 3DE series with different wiring | Space-limited installation |
3.2 EOCR-3EZ/FEZ Series (With Earth Fault Protection)
| Modèle | Plage actuelle | Puissance de contrôle | Type de câblage | Fonctionnalités principales | Scénarios applicables |
| EOCR-3EZ-05 | 0.5-6UN | 24-240V CA/CC | Window type | 3DE full functions + adjustable earth fault protection (30mA-1A) | Equipment requiring earth protection |
| EOCR-3EZ-30 | 3-30UN | 24-240V CA/CC | Window type | Same functions | Equipment requiring earth protection |
| EOCR-3EZ-80 | 5-80UN | 24-240V CA/CC | Window type | Same functions | Equipment requiring earth protection |
| EOCR-FEZ-05 | 0.5-6UN | 24-240V CA/CC | Feed-through type | Same as 3EZ series | Space-limited installation + earth protection |
| EOCR-FEZ-30 | 3-30UN | 24-240V CA/CC | Feed-through type | Same as 3EZ series | Space-limited installation + earth protection |
| EOCR-FEZ-80 | 5-80UN | 24-240V CA/CC | Feed-through type | Same as 3EZ series | Space-limited installation + earth protection |
3.3 EOCR-3E420/FE420 Series (With 4-20mA Output)
| Modèle | Plage actuelle | Puissance de contrôle | Type de câblage | Fonctionnalités principales | Scénarios applicables |
| EOCR-3E420-05 | 0.5-6UN | 24-240V CA/CC | Window type | 3DE functions + 4-20mA analog output | Remote monitoring system |
| EOCR-3E420-30 | 3-30UN | 24-240V CA/CC | Window type | Same functions | Remote monitoring system |
| EOCR-3E420-60 | 5-60UN | 24-240V CA/CC | Window type | Same functions | Remote monitoring system |
| EOCR-FE420-05 | 0.5-6UN | 24-240V CA/CC | Feed-through type | Same as 3E420 series | Space-limited + surveillance à distance |
| EOCR-FE420-30 | 3-30UN | 24-240V CA/CC | Feed-through type | Same as 3E420 series | Space-limited + surveillance à distance |
| EOCR-FE420-60 | 5-60UN | 24-240V CA/CC | Feed-through type | Same as 3E420 series | Space-limited + surveillance à distance |
- Intelligent Protectors (EOCR-3DM2/FDM2/3MZ2 Series)
4.1 EOCR-3DM2 Series (Window Type)
| Modèle | Plage actuelle | Puissance de contrôle | Fonctionnalités principales | Fonction de communication | Scénarios applicables |
| EOCR-3DM2-WRDB | 0.5-80UN | 24À DC | Protection complète + affichage numérique + fault record + load selection | RS-485 Modbus | DC control system |
| EOCR-3DM2-WRDU | 0.5-80UN | 100-240V CA/CC | Protection complète + affichage numérique + fault record + load selection | RS-485 Modbus | CA & DC universal system |
| EOCR-3DM2-WRDBHZ | 0.5-80UN | 24À DC | With harmonic suppression function | RS-485 Modbus | Frequency conversion drive system |
| EOCR-3DM2-WRDUHZ | 0.5-80UN | 100-240V CA/CC | With harmonic suppression function | RS-485 Modbus | Frequency conversion drive system |
4.2 EOCR-FDM2 Series (Feed-through Type)
| Modèle | Plage actuelle | Puissance de contrôle | Fonctionnalités principales | Fonction de communication | Scénarios applicables |
| EOCR-FDM2-FRDB | 0.5-80UN | 24À DC | Protection complète + affichage numérique + fault record + load selection | RS-485 Modbus | DC control system |
| EOCR-FDM2-FRDU | 0.5-80UN | 100-240V CA/CC | Protection complète + affichage numérique + fault record + load selection | RS-485 Modbus | CA & DC universal system |
| EOCR-FDM2-FRDBHZ | 0.5-80UN | 24À DC | With harmonic suppression function | RS-485 Modbus | Frequency conversion drive system |
| EOCR-FDM2-FRDUHZ | 0.5-80UN | 100-240V CA/CC | With harmonic suppression function | RS-485 Modbus | Frequency conversion drive system |
4.3 EOCR-3MZ2 Series (Type de borne, External CT Required)
| Modèle | Plage actuelle | Puissance de contrôle | Fonctionnalités principales | Fonction de communication | Scénarios applicables |
| EOCR-3MZ2-TRDB | 0.5-800UN (External CT) | 24À DC | Protection complète + affichage numérique + fault record + load selection | RS-485 Modbus | High current motor |
| EOCR-3MZ2-TRDU | 0.5-800UN (External CT) | 100-240V CA/CC | Protection complète + affichage numérique + fault record + load selection | RS-485 Modbus | High current motor |
| EOCR-3MZ2-TRDBHZ | 0.5-800UN (External CT) | 24À DC | With harmonic suppression function | RS-485 Modbus | High current frequency conversion motor |
| EOCR-3MZ2-TRDUHZ | 0.5-800UN (External CT) | 100-240V CA/CC | With harmonic suppression function | RS-485 Modbus | High current frequency conversion motor |
- Special Function Protectors
5.1 EOCR-DS/DS3 Series (Economical Digital Display Type)
| Modèle | Plage actuelle | Puissance de contrôle | Fonctionnalités principales | Scénarios applicables |
| EOCRDS-05S | 0.5-6UN | 24-240V CA/CC | Overload/Phase Loss/Stall protection, affichage numérique | Basic digital display demand |
| EOCRDS-30S | 3-30UN | 24-240V CA/CC | Overload/Phase Loss/Stall protection, affichage numérique | Basic digital display demand |
| EOCRDS-60S | 5-60UN | 24-240V CA/CC | Overload/Phase Loss/Stall protection, affichage numérique | Basic digital display demand |
| EOCRDS3-05S | 0.5-6UN | 24-240V CA/CC | Upgraded version with additional phase unbalance protection | Basic display + unbalance protection |
| EOCRDS3-30S | 3-30UN | 24-240V CA/CC | Upgraded version with additional phase unbalance protection | Basic display + unbalance protection |
| EOCRDS3-60S | 5-60UN | 24-240V CA/CC | Upgraded version with additional phase unbalance protection | Basic display + unbalance protection |
5.2 EOCR-PMZ/PFZ Series (Power Monitoring Type)
| Modèle | Plage actuelle | Puissance de contrôle | Fonctionnalités principales | Fonction de communication | Scénarios applicables |
| EOCR-PMZ-05 | 0.5-6UN | 24-240V CA/CC | Protection complète + power monitoring + energy metering | RS-485 Modbus | Energy consumption monitoring system |
| EOCR-PMZ-30 | 3-30UN | 24-240V CA/CC | Protection complète + power monitoring + energy metering | RS-485 Modbus | Energy consumption monitoring system |
| EOCR-PMZ-80 | 5-80UN | 24-240V CA/CC | Protection complète + power monitoring + energy metering | RS-485 Modbus | Energy consumption monitoring system |
| EOCR-PFZ-05 | 0.5-6UN | 24-240V CA/CC | Feed-through type, same functions as PMZ series | RS-485 Modbus | Energy monitoring + espace limité |
| EOCR-PFZ-30 | 3-30UN | 24-240V CA/CC | Feed-through type, same functions as PMZ series | RS-485 Modbus | Energy monitoring + espace limité |
| EOCR-PFZ-80 | 5-80UN | 24-240V CA/CC | Feed-through type, same functions as PMZ series | RS-485 Modbus | Energy monitoring + espace limité |
5.3 EOCR-DGT Series (Type de protection contre les fuites)
| Modèle | Plage actuelle | Plage de protection contre les fuites | Puissance de contrôle | Fonctionnalités principales | Scénarios applicables |
| EOCR-DGT-05 | 0.5-6UN | 30mA-1A | 24-240V CA/CC | Fuite + Surcharge + Phase Loss + Reverse Phase + Unbalance protection | Equipment in humid environment |
| EOCR-DGT-30 | 3-30UN | 30mA-1A | 24-240V CA/CC | Full combined protection | Equipment in humid environment |
| EOCR-DGT-60 | 5-60UN | 30mA-1A | 24-240V CA/CC | Full combined protection | Equipment in humid environment |
| EOCR-DGT-80 | 5-80UN | 30mA-1A | 24-240V CA/CC | Full combined protection | Equipment in humid environment |
- Quick Memorization of Model Naming Rules
- Préfixe: EOCR= Schneider motor protection relay series mark
- Code de série:
SS/SSD: Economical type (SSD with digital display)
3DE/FDE/3EZ/FEZ/3E420/FE420: Multifunctional digital type
3DM2/FDM2/3MZ2: Intelligent type (3MZ2 needs external CT)
DS/DS3: Simple digital display type
PMZ/PFZ: Power monitoring type
DGT: Leakage protection type
- Code actuel: 05(0.5-6UN), 30(3-30UN), 60(5-60UN), 80(5-80UN)
- Power Supply Code: S(24-240V CA/CC), W(380V et), B(24VCC), U(100-240V CA/CC)
- Mode de câblage: W(Window), F(Feed-through), T(Type de borne)
- Special Function: HZ(Harmonic suppression), 420(4-20mA output)
- Quick Selection Table by Functional Demand
| Functional Demand | Série recommandée | Avantages principaux | Max Current |
| Protection de base & faible coût | EOCR-SS/SSD | Rentable, installation facile | 60UN |
| Protection de base + affichage numérique | EOCRSSD/DS | Visualized fault checking | 60UN |
| Protection complète + earth fault protection | EOCR-3EZ/FEZ | Anti-leakage, high safety level | 80UN |
| Surveillance à distance + analog signal | EOCR-3E420/FE420 | 4-20mA signal output, easy system integration | 60UN |
| Intelligent control + communication | EOCR-3DM2/FDM2 | Modbus remote control | 80UN |
| High current motor protection | EOCR-3MZ2 | Match external CT, cover 0.5-800A | 800UN |
| Energy consumption monitoring + protection | EOCR-PMZ/PFZ | Power statistics and energy-saving analysis | 80UN |
| Leakage protection + full combined protection | EOCR-DGT | Protection intégrée contre les fuites | 80UN |
Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires



















NH42-63-318x560.png)