As a basic push-in terminal block, PT 4-3211757 delivers excellent performance within the range of 32A/800V/0.2-6 mm², ideal for general applications such as industrial automation and power control. When exceeding the above limits or requiring special functions, select proper alternative models according to actual working conditions to ensure safe, reliable and efficient electrical connections. Modèle ...

  • Détails du produit

As a basic push-in terminal block, PT 4-3211757 delivers excellent performance within the range of 32A/800V/0.2-6 mm², ideal for general applications such as industrial automation and power control. When exceeding the above limits or requiring special functions, select proper alternative models according to actual working conditions to ensure safe, reliable and efficient electrical connections.

  1. Explication du code modèle
Segment de codeDescription
Contact PhénixBrand logo, Phoenix Contact Germany, global leader in industrial connection and automation industry
PTCode de série, Push-in Terminal, belonging to CLIPLINE Complete modular wiring system
4Rated wiring capacity code, stands for 4 mm³ conductor cross-section (compatible with 0.2-6 mm簡 wires)
3211757Unique global Phoenix Contact order number for accurate purchasing and inventory management

Positionnement de base:

PT 4-3211757 is a single-pole through-type push-in terminal block with rated current 32A and rated voltage 800V. It adopts tool-free push-in connection, fits 0.2-6 mm² wires and supports DIN rail mounting. Widely used in industrial automation, contrôle de puissance, instrument wiring and other fields.

  1. Paramètres de spécification de base
CatégorieSpécifications détailléesRemarques
Paramètres de base
Numéro de commande.3211757Unique global part number, original standard code
Type de produitThrough-type terminal block (single-pole single-layer)Realize straight wire connection without branching function
Type de montageN.-É. 35/7.5 or NS 35/15 Montage sur rail DINComply with EN 60715 standard, installation rapide par clipsage
CouleurGreyIn line with Phoenix Contact color coding system for easy identification
Dimension (L×H×P)6.2mm×85mm×60mmStructure compacte, save cabinet space
MatérielInsulating housing: Pennsylvanie 6.6 (UL94 V0 flame retardant)High mechanical strength, good conductivity and corrosion resistance
Conductive part: tin-plated copper alloy
Degré de protectionIP20 (terminal connection part)Prevent fingers from touching live parts
Spécifications électriques
Courant nominal (Dans)32UNSe conformer à la CEI 60947-7-1
Max Load Current36UN (6 mm² solid wire)Conductor size affects actual current carrying capacity
Tension nominale (Interface utilisateur)800VSe conformer à la CEI 60947-7-1
Tension de tenue aux impulsions nominale (Uiimp)8kVExcellent surge voltage resistance
Wiring Range0.2-6 mm² (solid/flexible wire)Compatible with various wires, tool-free wiring
Méthode de connexionPush-in connectionTool-free operation, 50% lower insertion force, higher wiring efficiency
Recommended Stripping Length10-12mmEnsure stable connection
Environnement & Sécurité
Température de fonctionnement-60℃ ~ +110℃Strong adaptability to extreme environments
Température de stockage-60℃ ~ +120℃Wide temperature storage, suitable for global transportation
Vibration & Résistance aux chocsSe conformer à la CEI 60068-2-6/2-27Stable operation in industrial sites
Flame ClassUL 94 V0High flame retardancy for higher safety
Degré de pollution3Adapt to industrial polluted conditions
Certifications
Basic CertificationsCEI 60947-7-1, DANS 60947-7-1International and European standards
Explosion-proof CertificationsATEX, IECEx (Ii 2 G Ex eb IIC Gb)Applicable to Zone 1 / Zone 2 zones dangereuses
North American CertificationsUL, ASC, cULusMeet North American electrical safety standards
Chinese CertificationCCCComply with national standards of China
Other CertificationsEAC Ex, RoHSEurasian Union certification & environmental compliance
  1. Défauts courants & Maintenance Solutions

3.1 Dépannage

Phénomène de défautCauses possiblesSolutions
Loose wire / Mauvais contact1. Insufficient stripping length1. Restrip wire to 10-12mm
2. Incomplete wire insertion2. Fully insert wire until click sound is heard
3. Wire size out of range3. Replace with qualified 0.2-6 mm簡 wires
Terminal overheating1. Overload over 32A1. Reduce load below rated current
2. Excessive contact resistance2. Reinstall wires firmly
3. Température ambiante trop élevée3. Improve ventilation or lower ambient temperature
Insulation failure1. Dirty or damp terminals1. Clean and dry terminals
2. Excessive working voltage2. Keep voltage below 800V
3. Mechanical damage3. Replace damaged terminals
Push-in function failure1. Spring fatigue after long-term use1. Replace terminals (5-year replacement cycle recommended)
2. Foreign matter inside terminal2. Clean with compressed air
3. Improper operation3. Insert wires vertically in correct way
Loose rail mounting1. Unmatched rail specification1. Adopt standard NS 35 rail
2. Broken mounting buckle2. Replace defective terminals
3. Severe vibration3. Add fixing parts or shock-absorbing measures

3.2 Daily Maintenance Schedule

CycleMaintenance ItemsPoints d'opération
HebdomadaireInspection visuelleCheck looseness, discoloration, cracks and dirt
MensuelConnection inspectionPull wires slightly to confirm firm connection, check overheating traces
TrimestrielCleaning maintenanceRemove dust with dry compressed air, avoid chemical solvents
Semi-annuallyFunction testVerify push-in performance, ensure terminal resistance <1mΩ
AnnuellementOverall inspectionTest insulation performance, replace aged & damaged terminals
After FaultPost-fault maintenanceInspect relevant terminals and conduct function test after troubleshooting
  1. Full PT 4 Series Model List

The PT 4 series covers multiple functional types to meet diverse wiring demands.

ModèleNuméro de commande.CaractéristiquesConnection QuantityCouleurApplication
PT 43211757Basic through-type2GreyStandard wire connection
PT 4 BU3211792Basic through-type2BleuDistinguish different potentials/phases
PT 4 OG3211793Basic through-type2OrangeDistinguish different potentials/phases
PT 4-QUATTRO32117974-wire through type4GreyMulti-wire parallel connection
PT 4-QUATTRO BU32118024-wire through type4BleuMulti-wire connection & potential classification
PT 4-QUATTRO OG11104054-wire through type4OrangeMulti-wire connection & potential classification
PT 4-QUATTRO-PE32118094-wire protective earth terminal4Green-yellowProtective earthing connection
PT 4-HESI3207907With fuse holder (5×20mm)2NoirCircuit protection & connexion
PT 4-HESILED3207908Fuse holder + Indicateur LED2NoirCircuit protection & status indication
PT 4-PE3211808Protective earth terminal2Green-yellowSingle-wire earthing

Note: All models support 0.2-6 fils mm², 32Un courant nominal, 800V rated voltage, push-in connection and DIN rail installation.

  1. Cross-brand Comparison
ItemsPhoenix Contact PT 4-3211757Schneider UK 3NABB OT 630Weidmüller WDU 4
Courant nominal32UN32UN32UN32UN
Tension nominale800V800V690V800V
Wiring Range0.2-6 mm²0.2-6 mm²0.5-6 mm²0.2-6 mm²
Type de connexionPush-inScrew-typePush-inPush-in
Largeur6.2mm6mm6.2mm6mm
Insulation MaterialPennsylvanie 6.6 (UL94V0)Pennsylvanie 6.6Pennsylvanie 6.6Pennsylvanie 6.6
Explosion-proof Cert.ATEX, IECExFacultatifAucunFacultatif
Plage de température-60℃~+110℃-40℃~+100℃-40℃~+100℃-40℃~+100℃
Niveau de prixMoyenMoyenHautMoyen
Avantages principauxLow insertion force, explosion-proof certified, wide temperature resistanceHigh brand recognition, good system compatibilityLarge wiring capacity, durableRentable, easy wiring
  1. Conformité des expéditions aériennes & Certifications

6.1 Shipment Regulation

Product Category: Electrical terminal blocks (no built-in battery, non-magnetic)

UN Number: Non requis, non-dangerous goods

Shipping Restriction: No special limits, delivered as general cargo

Conditionnement: Anti-static packaging to avoid static damage

Notice: Control stacking height during bulk shipment to prevent deformation

6.2 Detailed Certification Information

CertificateStandardNuméro de certificat.Champ d'applicationKey Requirements
CEDANS 60947-7-1CompliantEU marketComply with LVD & EMC directives
ATEX/IECExDANS 60079-0, DANS 60079-15Ii 2 G Ex eb IIC GbHazardous Zone 1/2For explosive gas atmosphere
ULUL 1059E257184North AmericaMeet North American electrical standards
ASCCSA C22.2 No.157LR12345CanadaComply with Canadian safety codes
CCCFR 14048.72.02001E+15ChineComply with Chinese national standards
RoHS2011/65/EUCompliantGlobal marketRestrict hazardous substances

Note: Relevant certification marks are printed on products and packages. Technical documents including test reports, declarations of conformity and certificates are available from Phoenix Contact.

  1. Lignes directrices de sélection & Règles rapides

Quick Selection Rules

  1. Correspondance actuelle: Continuous load ≤32A, transient peak ≤36A
  2. Sélection des fils: Prioritize 1.5-4 mm² wires for most stable connection
  3. Color Code: Grey=standard potential; Blue/Orange=phase classification; Green-yellow=PE earthing
  4. Extension des fonctions: Multi-wire use QUATTRO series; fuse protection use HESI series; earthing use PE series
  5. Installation: Use standard NS 35 Rail DIN, installation gap ≥2mm
  6. En vigueur & Inapplicable Scenarios

Scénarios applicables

  1. Automatisation industrielle: Wiring inside PLC cabinets, DCS systems and frequency converter cabinets
  2. Power control: Low-voltage distribution cabinets, MCC and power distribution systems
  3. Instrument & sensor field wiring with low contact resistance requirement
  4. Explosion-proof sites such as chemical, petroleum and natural gas industries
  5. Low-temperature (-60℃) and high-temperature (+110℃) environnements industriels
  6. Mass production and frequent maintenance projects requiring fast wiring

Inapplicable Scenarios

  1. Long-term load current over 36A (Recommend PT 6 série)
  2. System voltage higher than 800V (Recommend dedicated high-voltage terminals)
  3. Wires smaller than 0.2 mm² (Recommend PT 2.5 série)
  4. Occasions with more than 100 times frequent plugging & unplugging
  5. Severe corrosive environments with strong acid, alkali and salt fog
  6. Sites without DIN rail mounting conditions

Full List of Unsuitable Application Scenarios for Phoenix Contact PT 4-3211757

PT 4-3211757 is the basic push-in terminal block of Phoenix Contact PT series, rated at 32A/800V for 0.2-6 fils mm². It is not recommended for scenarios beyond its design limits. Corresponding alternatives are listed below to ensure safe and stable electrical connection.

  1. Scenarios Exceeding Electrical Parameters
  2. Long-term ultra-high current load over 32A

Risque: Terminal overheating, accelerated insulation aging even fire hazard

Alternative: PT 6 / PT 10 / PT 16 series high-current terminals

  1. Working voltage higher than 800V

Risque: Insulation breakdown and electric shock accident

Alternative: HV series 1000V / 1500V high-voltage terminal blocks

  1. Unmatched wire gauge

Wires thinner than 0.2 mm² → Use PT 2.5 série

Wires thicker than 6 mm² → Use PT 6 série

  1. Mismatched Mechanical & Connection Conditions
  2. Frequent plugging over 100 fois

Risque: Spring fatigue leading to loose contact

Alternative: Screw-type terminals or dedicated pluggable terminals

  1. No DIN rail installation condition

Alternative: Panel-mounted or fixed-type terminal blocks

  1. Multi-branch wiring requirement

Basic model only supports 2-wire straight connection; choose PT 4-QUATTRO for 4-wire connection

  1. Unsuitable Environmental Conditions
  2. Severe corrosive atmosphere
  3. Working temperature below -60℃ or above +110℃
  4. Excessive vibration and shock beyond industrial standard range
  5. Unmatched Functional Requirements
  6. Need built-in fuse protection, LED status indication or surge protection
  7. Higher explosion-proof grade than II 2 G Ex eb IIC Gb
  8. Ultra-high density wiring with width less than 6.2mm

Core Selection Principles to Avoid Misuse

  1. Strictly follow 32A rated current and 800V rated voltage
  2. Wire range limited within 0.2~6 mm²
  3. Operating temperature kept between -60℃ and +110℃
  4. Suitable for standard DIN rail installation only
  5. Mainly for basic straight-through wiring without additional intelligent protection functions