Model Code Explanation GV2-P22 GV2: Série, motor-protection circuit-breaker (manual motor starter) P.: Thermal-magnetic protection type, rotary-knob current adjustment 22: Current setting range 20-25A Core Parameters Setting current: 20~25A Tripping characteristic: Thermal-overload trip + instantaneous magnetic short-circuit trip Main circuit: 3-pole Applicable motor: AC-3, moteur triphasé, maximum. approx.11kW (380V) Auxiliary functions: Compatible with add-on blocks GV2-AE, ...

  • Détails du produit

Explication du code modèle

GV2-P22

GV2: Série, motor-protection circuit-breaker (manual motor starter)

P.: Thermal-magnetic protection type, rotary-knob current adjustment

22: Current setting range 20-25A

Paramètres de base

  1. Courant de réglage: 20~25A
  2. Caractéristique de déclenchement: Thermal-overload trip + instantaneous magnetic short-circuit trip
  3. Circuit principal: 3-pôle
  4. Applicable motor: AC-3, moteur triphasé, maximum. approx.11kW (380V)
  5. Auxiliary functions: Compatible with add-on blocks GV2-AE, GV2-AN
  6. Montage: 35 mm DIN-rail mounting; assembled with contactor for direct-on-line starting unit

Common Replacements

Schneider in-series alternative: GV2-ME22 (lever-handle version, same 20-25 A range)

Alternatives nationales: Chint NS2-25 (20-25UN), Delixi CDV2s-25 (20-25UN)

Second-hand Inspection Checklist (for used-market purchase)

  1. Vérifiez le boîtier pour des fissures, burn marks or burnt terminal lugs
  2. Rotary knob should turn smoothly without jamming
  3. Verify normal closing and opening operations
  4. Cross-check nameplate: GV2-P22, 20-25 UN; do not confuse with GV2-P21 (17-23 UN)
  5. Distinguish models: GV2-P uses rotary knob; GV2-ME uses lever handle. Different housings, pas directement interchangeable.

Schneider GV2-P22 Motor Circuit-Breaker Full Specification Sheet

>Série: TeSys Deca GV2-P (imported rotary-knob manual motor starter)

  1. Informations de base sur le modèle
ArticleSpécification
ModèleGV2‑P22
Type de produitManual motor‑protection circuit‑breaker (Manual Motor Starter)
OpérationRotary‑knob operation (vs lever‑handle GV2‑ME)
Poteaux3P. (3-pôle)
Type de protectionThermique-magnétique: thermal‑overload protection + instantaneous magnetic short‑circuit protection
Thermal trip setting range20‑25 A
Magnetic trip current13×In ≈327 A (instant short‑circuit tripping)
Protection contre les manques de phaseSoutenu
Disconnect functionMain‑circuit isolation capability
  1. Paramètres électriques
ArticleSpécification
Tension assignée d'emploi UeAC 690 V, 50/60 Hz
Tension assignée d'isolement Ui690 ACC
Tension assignée de tenue aux chocs Uimp6 kV
Courant thermique conventionnel Ith25 UN
Catégorie d'utilisationAC‑3, AC‑3E (charge du moteur), Category‑A circuit‑breaker
Applicable 3‑phase motor power11 kW@400‑415 V; 15 kW@500 V
Power dissipation per pole2.5 W

Rated Ultimate Short-circuit Breaking Capacity Icu

TensionIcu Breaking Capacity
230‑240 V100 kA
400‑415 V50 kA
440 V20 kA
500 V10 kA
690 V4 kA
  1. Durée de vie mécanique & Câblage
ArticleSpécification
Endurance mécanique100 000 operating cycles
Electrical endurance AC‑3@415 V100 000 cycles
Fréquence de fonctionnement maximale25 opérations par heure
Type de borneBornes à vis-étrier
Couple de serrage1.7 N·m
Compatible conductorsSolid wire 1‑6 mm²; flexible wire with ferrule 1‑4 mm²; un‑ferruled flexible wire 1.5‑6 mm²
Méthode de montage35 mm standard DIN‑rail clip‑on mounting; or panel mounting with M4 screws
Orientation de montageHorizontal or vertical installation, no orientation restriction
Dimensions hors toutW 45 mm × H 89 mm × D 97 mm
Poids unitaireEnviron. 339 g
  1. Environnement & Protection
ArticleSpécification
Enclosure protection ratingIP20 (terminal side)
Impact resistance IK‑ratingIK04
Température ambiante de fonctionnement‑20 ℃ ~ +60 ℃
Température de stockage‑40 ℃ ~ +80 ℃
Résistance aux vibrations5 Gn, 5‑150 Hz; shock resistance 30 Gn/11 ms
Glow‑wire resistance960 ℃ glow‑wire test
  1. Certifications & Accessoires
  2. Certifications: CCC, UL, ASC, CAE, DNV-GL, B.V., RINA, LROS marine classification, ATEX, UKCA, RoHS / ATTEINDRE
  3. Livraison standard: Unit only, no built-in auxiliary contacts; must order separately

Auxiliary contact blocks: GV2-AN (1NON+1NC), GV2-AE (fault-signal contact)

Déclenchement de dérivation, déclenchement par sous-tension, door-interlock mechanism and others are optional accessories

  1. Origin note: GV2-P22 is imported version. Domestic rotary-knob variant GV2PM22 shares same current range but differs in breaking-capacity and depth dimension; cannot be treated as full equivalent replacement.
  2. In-series Comparison & Sélection de remplacement
  3. Schneider lever-handle equivalent: GV2-ME22 (20-25 UN, lever-handle type, different housing outline, accessories are interchangeable)
  4. Domestic alternative references:

Chint NS2-25 20-25A

Delixi CDV2s-25 20-25A

  1. Second-hand Inspection Checklist (Used-market)
  2. Nameplate verification: Model GV2-P22, 20-25 UN. Do not confuse with GV2-P21 (17-23 UN).
  3. Rotary knob turns smoothly, ON/OFF positions clear, no sticking.
  4. Housing free of cracks; terminal lugs without burning or erosion.
  5. Perform manual close-open test. If possible, verify thermal-trip and magnetic-trip functions.
  6. Distinguish GV2-P (imported, depth 97 mm) vs GV2PM (domestique, depth 91 mm). Housings are not directly interchangeable.

Application Scenarios for Schneider GV2-P22 Motor Circuit-Breaker

GV2-P22 (adjustable 20-25 A, max 11 kW three-phase motor @400 V) belongs to TeSys GV2-P rotary-knob thermal-magnetic manual motor starter. It integrates short-circuit protection, motor overload protection, phase-failure protection and main-circuit isolation. It performs local motor on-off control and is frequently paired with contactors and overload relays for motor starting circuits. Widely deployed for small-to-medium three-phase motors in industrial machinery, lignes de convoyeurs, CVC, light lifting and pump systems.

✅ Typical Load Matching (400 V three-phase reference)

Matched motor rating: 7.5 kW ~11 kW three-phase asynchronous motor

Note: Only select this model when the motor full-load current falls within the 20-25 A window. Do not over-size the setting for smaller motors, otherwise overload protection will be lost.

  1. Industrial Equipment Applications
  2. Machine-tool equipment

Drilling machines, small milling machines, broyeurs, light cutting equipment; machine-tool cooling pumps, hydraulic-station oil-pump motors.

Fonction: Instant tripping for motor stall, overload and winding short-circuit. Rotary knob provides local manual switching plus isolation for maintenance.

  1. Convoyeur & material-handling lines

Convoyeurs à bande, convoyeurs à rouleaux, petits ascenseurs, sorting-equipment drive motors.

Avantage: Compact DIN-rail installation for dense cabinet layout. GV2-AE fault-alarm block can be added to send fault signals to PLC.

  1. Ventilateur & Systèmes CVC

Industrial centrifugal fans, cabinet fans, workshop exhaust fans, air-handling-unit fan motors.

Suited for fan-type high-inrush-current loads; thermal-magnetic characteristic tolerates starting surge while protecting against sustained overload.

  1. Pump applications

Pompes de circulation, pompes à eaux usées, pompes de surpression, small hydraulic oil pumps.

Sewage pumps are prone to rotor stalling; built-in phase-failure protection prevents motor burnout from single-phasing. Rotary knob provides local switching and maintenance isolation inside control cabinets.

  1. Control-cabinet Integration
  2. Direct-on-line motor starter circuits (le plus courant)

Scheme 1: Stand-alone GV2-P22 for local manual protection & switching for small motors without remote control.

Scheme 2: GV2-P22 + LC1D contactor forming a complete DOL starter: circuit-breaker provides short-circuit & protection contre les surcharges; contactor executes PLC-based remote start-stop.

Classic configuration widely used inside PLC cabinets and MCC motor-control boxes.

  1. Local field control boxes

Compact on-machine local control enclosures. Rotary knob switches motor and provides electrical isolation in OFF position, removing need for separate disconnector.

  1. Other Industry Uses
  2. Logistique & light lifting equipment

Petits treuils, auxiliary lifting motors (not for primary hoist safety circuits).

  1. Plastics-processing machinery

Auxiliary small extruder drives, hopper feeding motors, mixer motors.

  1. Marin / offshore auxiliary equipment

GV2-P series carries full marine classification-society approvals for on-board auxiliary pumps and ventilation fans inside engine compartments. ⚠️ Domestic GV2PM lacks full marine certifications; imported GV2-P must be specified for marine projects.

❌ Not-Recommended Applications

  1. Not intended for single-phase loads or lighting circuits: Optimized specifically for motor protection logic, not general-purpose distribution.
  2. Puissance du moteur >11 kW @400 V: Exceeds setting-current range; upgrade to GV3-series.
  3. Downstream of VFD output terminals: Cannot connect to inverter output side. Only install on VFD input supply side for upstream protection.
  4. Frequent forward-reverse jog-cycle operation: Add contactor for repeated switching; avoid frequent manipulation of the GV2-P rotary knob to preserve mechanical service-life.

💡 Selection & Conseils d'utilisation

  1. Adjust rotary setting dial strictly according to motor nameplate full-load current. Do not simply turn to maximum 25 A; set to 21 A for a motor rated 21 A.
  2. Remote fault-signal output requires add-on GV2-AE fault-contact block; no alarm output built-into unit.
  3. GV2-P22 is imported rotary-knob variant. While protection parameters match lever-handle GV2-ME22, physical depth differs; check cabinet depth for retrofit replacement.
  4. For used-unit deployment: Prioritize functional trip-test rather than cosmetic inspection only.