Schneider iC65N 2P 32A Miniature Circuit Breaker - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

 Schneider iC65N 2P 32A Miniature Circuit Breaker - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

disjoncteur/

Schneider iC65N 2P 32A Miniature Circuit Breaker

Désignation standard: iC65N 2P C32A (commonly abbreviated as IC65N-2P32A in the market; C-curve by default) Material codes: A9F18232 (Courbe C); A9F17232 (Courbe B); A9F19232 (Courbe D) ✅ Model Definition iC65: Acti9 series miniature circuit breaker N: Breaking capacity class 6kA (iC65H=10kA, iC65L=15kA) 2P.: 2-pôle, simultaneous disconnection of phase and neutral for protection 32A: Rated current In=32A C-curve (most ...

  • Détails du produit

Désignation standard: iC65N 2P C32A (commonly abbreviated as IC65N-2P32A in the market; C-curve by default)

Material codes: A9F18232 (Courbe C); A9F17232 (Courbe B); A9F19232 (Courbe D)

✅ Model Definition

iC65: Série Acti9 disjoncteur miniature

N: Breaking capacity class 6kA (iC65H=10kA, iC65L=15kA)

2P.: 2-pôle, simultaneous disconnection of phase and neutral for protection

32UN: Rated current In=32A

Courbe C (le plus courant): Magnetic trip 5~10In, adapté à l'éclairage, socket outlets and general power loads; B-curve 3~5In (low-voltage circuits); D-curve 10~20In (moteurs, transformers with inrush current)

📋 Core Electrical Specifications

Rated voltage Ue: AC 230/400V, 50/60Hz

Rated short-circuit breaking capacity Icn: 6kA @400V AC (GB10963.1 / IEC60898-1)

Protection: Déclenchement thermomagnétique (surcharge + short-circuit dual protection), disconnector function

Montage: DIN35mm rail, width 36mm (2 modules)

Insulation voltage Ui: 500V; Tension de tenue aux chocs Uimp: 6kV

Current limiting class: Classe 3

Terminal protection IP20, IP40 when installed inside enclosure; CCC, Certification CE

Câblage: De haut en bas / bottom-in top-out both acceptable

📌 Applications typiques

Main incoming breaker for residential buildings, single-phase distribution circuits in shops

Éclairage, circuits de prise, ordinary fans and water pumps (Courbe C)

Can be assembled with Vigi iC65 residual current add-on block to form RCBO

🔄 Replacement Information

Modèle prédécesseur: C65N 2P32A (abandonné)

Schneider equivalent upgrade: iC60N 2P C32A (A9F74232)

Equivalent national: Chint NXB-63 2P C32A, Delixi DZ47s 2P C32A

⚙️ Optional Accessories (compatible within series)

Vigi iC65 RCD add-on block (30mA Type A)

iMX shunt trip release, iMN undervoltage release, iOF auxiliary contact, iSD fault alarm contact

Differences between iC65N series and iC60N series

iC65N: China domestic version (CCC); iC60N: International general version (CE/IEC). Same outline, module width and basic tripping characteristic; 6kA breaking capacity per IEC60898. Directly interchangeable on DIN rail. But they differ in certification, applicable standards, contact status indication, available trip curves, accessory system and material codes.

  1. Positionnement sur le marché & Attestation

iC65N: Model dedicated for Chinese market, Certifié CCC, standard GB10963.1 (identical to IEC60898-1). No separate CE for overseas acceptance, not recognized for export projects.

Material prefix: A9F18xxxx (Courbe C). Exemple: 2P C32A = A9F18232

iC60N: Global Acti9 international version, CE+IEC certified, compliant with IEC60898-1 (household distribution) + CEI60947-2 (industrial disconnector). Preferred for export panels, overseas complete sets and foreign-invested projects.

Material prefix: A9F74xxxx (Courbe C). Exemple: 2P C32A = A9F74232

  1. Capacité de coupure (Différence clé)

iC65N N grade: 6kA @400V (IEC60898 only)

iC60N N grade: 6le (IEC60898) / 10le (IEC60947 industrial condition), higher breaking capacity under industrial standard

  1. Available Trip Curves

iC65N: B / C / D

iC60N: B / C / D / K / Z / MA (K for transformers, Z for electronic circuits, MA fixed magnetic trip for motors; wider selection for industrial control)

  1. Front Panel Indication (VisiSafe / VisiTrip)

iC65N: Simplified China version. Green handle = open position; red marker for fault trip

iC60N: Full VisiSafe (visible true contact separation) + VisiTrip (independent red window for fault trip). Widely required by overseas safety specifications and site verification

  1. Compatibilité des accessoires

Accessories look identical but have separate material code ranges. Strongly recommended to match accessories within the same series

iC65: iOF / iSD / iMX / iMN, Vigi iC65 RCD add-ons (China A9 domestic accessories)

iC60: Vigi iC60, overseas auxiliary / voyage de dérivation; compatible with PowerTag smart energy monitoring modules (iC65 generally not fitted with overseas smart modules)

  1. Dimension & Interchangeabilité

✅ Same module size: 1P=18mm, 2P=36mm, direct DIN35 rail swap, wiring from top or bottom allowed

⚠️ Important risk note: iC65N preferred for domestic cabinets in China; for export, foreign-owned projects or CE certificate requirement, select iC60N. iC65N cannot be substituted, overseas inspectors do not accept iC65N certificates.

  1. Selection Comparison Table
ArticleiC65NiC60N
Sales TerritoryMainland China onlyMondial
Main CertificationCCCCE, CEI
Norme applicableGB10963.1IEC60898-1 + CEI60947-2
Capacité de coupure (N)6le6le (distribution) /10le (industriel)
Trip CurvesB/C/DB/C/D/K/Z/MA
Indication d'étatBasic open indicationVisiSafe+VisiTrip dual indication
Application typiqueRésidentiel, domestic construction, local panel buildExporter, foreign-owned factory, projet à l'étranger, industrial distribution
  1. Reference for your model 2P32A

iC65N 2P C32A: A9F18232 (regular stock for China domestic)

iC60N 2P C32A: A9F74232 (for export / foreign invested projects)

  1. Prefix Coding Rule

1) iC65N (China CCC version)

Courbe B: A9F17xxxx

Courbe C: A9F18xxxx (grand public)

Courbe D: A9F19xxxx

5th digit = pole count: 1=1P; 2=2P; 3=3P; 4=4P

Last two digits = rated current: 01=1A, 02=2A…32=32A, 63=63A

2) iC60N (International CE version)

Courbe B: A9F73xxxx

Courbe C: A9F74xxxx (mainstream for export)

Courbe D: A9F75xxxx

Pôle & current coding rule identical to iC65N, one-to-one mechanical interchange

  1. iC65N Full Model & Material Code List (B/C/D, 1P/2P/3P/4P, 1~63A)

(1) 1P Single Pole

ActuelCourbe B(A9F171xx)Courbe C(A9F181xx)Courbe D(A9F191xx)
1UNA9F17101A9F18101A9F19101
2UNA9F17102A9F18102A9F19102
4UNA9F17104A9F18104A9F19104
6UNA9F17106A9F18106A9F19106
10UNA9F17110A9F18110A9F19110
16UNA9F17116A9F18116A9F19116
20UNA9F17120A9F18120A9F19120
25UNA9F17125A9F18125A9F19125
32UNA9F17132A9F18132A9F19132
40UNA9F17140A9F18140A9F19140
50UNA9F17150A9F18150A9F19150
63UNA9F17163A9F18163A9F19163

(2) 2P Two Pole (your 2P32A here)

ActuelCourbe B(A9F172xx)Courbe C(A9F182xx)Courbe D(A9F192xx)
1UNA9F17201A9F18201A9F19201
2UNA9F17202A9F18202A9F19202
4UNA9F17204A9F18204A9F19204
6UNA9F17206A9F18206A9F19206
10UNA9F17210A9F18210A9F19210
16UNA9F17216A9F18216A9F19216
20UNA9F17220A9F18220A9F19220
25UNA9F17225A9F18225A9F19225
32UNA9F17232A9F18232A9F19232
40UNA9F17240A9F18240A9F19240
50UNA9F17250A9F18250A9F19250
63UNA9F17263A9F18263A9F19263

(3) 3P Three Pole

ActuelCourbe B(A9F173xx)Courbe C(A9F183xx)Courbe D(A9F193xx)
6A~63AA9F173xxA9F183xxA9F193xx
32UNA9F17332A9F18332A9F19332
63UNA9F17363A9F18363A9F19363

(4) 4P Four Pole

ActuelCourbe B(A9F174xx)Courbe C(A9F184xx)Courbe D(A9F194xx)
32UNA9F17432A9F18432A9F19432
63UNA9F17463A9F18463A9F19463

III. iC60N Full Model & Material Code List (B/C/D,1P/2P/3P/4P,1~63A)

Coding Reference

Courbe B: A9F73xxx

Courbe C: A9F74xxx (mainstream for export)

Courbe D: A9F75xxx

(1) 1P.

ActuelB(A9F731xx)C(A9F741xx)D(A9F751xx)
32UNA9F73132A9F74132A9F75132
63UNA9F73163A9F74163A9F75163

(2) 2P. (match your 2P32A)

ActuelB(A9F732xx)C(A9F742xx)D(A9F752xx)
32UNA9F73232A9F74232A9F75232
63UNA9F73263A9F74263A9F75263

(3) 3P.

ActuelB(A9F733xx)C(A9F743xx)D(A9F753xx)
32UNA9F73332A9F74332A9F75332
63UNA9F73363A9F74363A9F75363

(4) 4P.

ActuelB(A9F734xx)C(A9F744xx)D(A9F754xx)
32UNA9F73432A9F74432A9F75432
63UNA9F73463A9F74463A9F75463
  1. Direct Replacement for your 2P32A
  2. Domestic China project requiring CCC: iC65N 2P C32A → A9F18232
  3. Exporter / foreign-invested project requiring CE: iC60N 2P C32A → A9F74232
  4. Matching RCD Add-on Blocks (DO NOT cross-series mix)

For iC65N: Vigi iC65 residual current add-on (A9V52xxx)

For iC60N: Vigi iC60 residual current add-on (A9V53xxx)

Précédent:

Laisser une réponse

Laisser un message