Schneider P127BA0V6D3FE0 Protection Relay

Schneider MiCOM P127BA0V6D3FE0 Overcurrent and Earth Fault Protection Relay Schneider MiCOM Px20 series 3-phase and earth fault comprehensive protection relay, Type B earth current input (1Une note), V6 voltage module (57-130V), D3 communication module (dual-port), FE0 output configuration (8 relais programmables). It supports 24-250V DC / 48-240V AC power supply with IP50 ingress protection. Applied ...

  • Détails du produit

Schneider MiCOM P127BA0V6D3FE0 Overcurrent and Earth Fault Protection Relay

Schneider MiCOM Px20 series 3-phase and earth fault comprehensive protection relay, Type B earth current input (1Une note), V6 voltage module (57-130V), D3 communication module (dual-port), FE0 output configuration (8 relais programmables). It supports 24-250V DC / 48-240V AC power supply with IP50 ingress protection. Applied for the protection of feeders, transformateurs, motors and other equipment in medium and low-voltage power systems. Part number: P127BA0V6D3FE0.

  1. Définition du segment du modèle
Segment de modèleDescription
P127Série de produits: MiCOM Px20 series, full 3-phase and earth fault protection relay
BEarth current input type: Tapez B, rated current Ion=1A, measuring range 0.01–8 Ion
A0Auxiliary function code: Configuration standard, no special extended functions
V6Voltage module type: V6, input range 57-130V, compatible with PT secondary voltage
D3Communication module type: D3 dual communication ports (front RS232 / rear RS485); supports Modbus / IEC60870-5-103 / DNP3.0
FE0Output configuration: FE0 type, 8 programmable relay outputs (y compris 1 master trip output RL1)
P127BA0V6D3FE0Schneider official part number, globally unique identifier
  1. Full Version Technical Specification
Catégorie de paramètreCaractéristiquesRemarques
Basic Info3-phase & earth fault protection relay, ANSI 50/51/50G/51G protection functionsFor medium/low voltage feeder protection
Part NumberP127BA0V6D3FE0Order strictly by this code
DimensionsW144mm × H144mm × D190mmFlush mount, fits standard 19-inch cabinet
Alimentation24-250À DC / 48-240V etWide voltage input for various power systems
Current InputPhase current: 5UN (standard) / 1UN (facultatif); Earth current: 1UN (Tapez B)Accuracy class 0.2; measuring range 0.01–8× rated value
Voltage Input57-130V (V6 module)Matches PT secondary; phase/line voltage selectable
Fonctions de protectionPhase Overcurrent Stage I/II/III, Earth Overcurrent Stage I/II, Directional Protection, Auto-reclosing, Cold Load Pickup8 setting groups for flexible configuration
Output Configuration8 programmable relay outputs (RL1-RL8), RL1 as master trip outputÉvaluation des contacts: 5A @ 250V AC / 30À DC
Interface de communicationFront port: RS232 (local commissioning); Rear port: RS485 (system communication)Prend en charge Modbus RTU, IEC60870-5-103, DNP3.0
Measurement FunctionsActuel, tension, pouvoir, fréquence, énergie; dynamic average/peak value recording250 event records, 25 enregistrements de défauts (1600Hz sampling)
Conditions ambiantesFonctionnement: -25°C ~ +70°C; Stockage: -40°C ~ +85°C; Humidity ≤95% (sans condensation)Industrial grade for harsh environments
CertificationsCE, UL, ASC, CEI 60255Complies with global power equipment safety standards
Durée de vieRelay mechanical life: 10⁵ operationsDurée de vie électrique: 10⁴ cycles at rated load
PoidsEnviron. 3.5kilosLightweight for easy installation
  1. MiCOM P127 Full Model List
Part NumberModèleEarth Current InputVoltage ModuleModule de communicationOutput ConfigurationFonctionnalités spéciales
P127BA0V6D3FE0P127Tapez B (1UN)V6 (57-130V)D3 (Dual-port)FE0 (8 relais)Standard feeder protection
P127AA0V6D3FE0P127Type A (5UN)V6 (57-130V)D3 (Dual-port)FE0 (8 relais)5A phase current for standard CT
P127BA0Z1D3FE0P127Tapez B (1UN)Z1 (24-60V)D3 (Dual-port)FE0 (8 relais)Low voltage module for special power supply
P127BA0V6D1FE0P127Tapez B (1UN)V6 (57-130V)D1 (Single-port)FE0 (8 relais)Single communication port, rentable
P127BA0V6D3GE0P127Tapez B (1UN)V6 (57-130V)D3 (Dual-port)GE0 (12 relais)Extended outputs for complex logic
P127BA1V6D3FE0P127Tapez B (1UN)V6 (57-130V)D3 (Dual-port)FE0 (8 relais)With IRIG-B synchronization for precision time control
P127CA0V6D3FE0P127Tapez C (0.1UN)V6 (57-130V)D3 (Dual-port)FE0 (8 relais)High-sensitivity earth input for low-current earthing systems
  1. Remplacement & Comparaison entre marques

4.1 Same Brand Direct Replacement

Modèle originalModèle de remplacementDescriptionApplication
P127BA0V6D3FE0P127BA0V6D3GE0Upgraded to 12 relay outputs with expanded control capacityComplex protection logic requiring more control outputs
P127BA0V6D3FE0P127BA1V6D3FE0Added IRIG-B time synchronization for higher timestamp accuracyPower system fault analysis requiring precise time stamping
P127BA0V6D3FE0P127CA0V6D3FE0Upgraded to Type C high-sensitivity 0.1A earth inputLow-current earthing systems such as petrochemical and metallurgy
P127BA0V6D3FE0P127BA0Z1D3FE0Replaced with Z1 24-60V low voltage moduleDC systems or special low-voltage power supply environments

4.2 Cross-Brand Equivalent Models

SchneiderABBSiemensGEPrincipales différences
P127BA0V6D3FE0REF6157SJ60Multilin 369Schneider cost-performance & configuration flexible
ABB higher integration; Siemens richer protocol support
Schneider 8 setting groups for multiple protection schemes
GE larger event record capacity (500 enregistrements)
  1. Environnement d'application & Cas industriels

Applications recommandées

Système d'alimentation: Substation & distribution feeder protection up to 35kV

Automatisation industrielle: Moteur, transformer and busbar protection in petrochemical, métallurgie, coal industries

Railway: Surintensité & earth fault protection for traction power supply and station distribution

Nouvelle énergie: Combiner box and inverter protection for PV and wind farms

Bâtiments commerciaux: Standby power system protection for shopping complexes and data centers

Public Utilities: Power protection for pumping stations and water treatment projects

Cas d'application typiques

  1. Substation Feeder Protection in Chemical Park

Objective: Protect 10kV feeders against equipment damage and power outage caused by overcurrent & earth faults

Avantages: Large adaptabilité de tension; 8 programmable outputs for complex trip logic; dual-port communication for remote monitoring

System Configuration: P127BA0V6D3FE0 + 10kV Vacuum Circuit Breaker + SCADA System

Effect: Fault response <30MS; power outage duration reduced by 40%; power supply reliability improved

  1. Motor Protection Scheme for Automotive Factory

Objective: Protect large stamping line motors against overload and earth faults

Avantages: Directional protection for fault location discrimination; auto-reclosing reduces transient fault impact; event recording facilitates fault analysis

System Configuration: P127BA0V6D3FE0 + Centre multicompte + Industrial Ethernet

Effect: Motor failure rate reduced by 25%; production line efficiency increased by 18%

Not Recommended Scenarios

High voltage system (>35kV): Use MiCOM P40 or higher series

UHVDC system: Sans objet; dedicated DC protection relay required

Strong electromagnetic interference environment: Additional electromagnetic shielding required to avoid measurement deviation

Underwater / Humid outdoor environment: IP50 only suitable for indoor dry locations; outdoor installation requires protective enclosure

  1. Installation & Wiring Guidelines

Exigences d'installation

  1. Type de montage: Montage encastré; panel cutout 138×138mm, front panel 144×144mm
  2. Position d'installation: Install inside control cabinet, avoid direct sunlight and high heat source; reserve ≥50mm clearance for heat dissipation
  3. Wiring Standard: Current loop ≥2.5mm² copper cable; voltage loop ≥1.5mm² copper cable; separate routing ≥100mm between current and voltage wires
  4. Mise à la terre: Device earth terminal must be reliably connected; earth resistance ≤1Ω linked to station earthing grid
  5. Communication Wiring: RS485 uses shielded twisted pair; single-end shielding grounding; max communication distance 1200m

Core Terminal Definition

Numéro de borne.FonctionTaperRemarques
L1/L2/L3Phase Current Input5A/1AConnect CT secondary, pay attention to polarity
INEarth Current Input1UN (Tapez B)Connect residual CT secondary
UA/UB/UC/UNVoltage Input57-130VConnect PT secondary; phase/line voltage optional
DC+/DC-Alimentation24-250À DC / 48-240V etWide voltage with reverse polarity protection
RL1-RL8Sortie relaisNO/NC en optionRL1 master trip linked with trip indicator
COM1/COM2Communication PortRS232/RS485COM1 front port; COM2 rear port

Points clés de la mise en service

  1. Parameter Configuration: Use MiCOM S1 Studio via RS232 to set CT/PT ratio, protection settings and communication parameters
  2. Setting Group Selection: 8 setting groups switchable for different operation modes; Groupe 1 par défaut
  3. Protection Function Test: Simulate phase overcurrent & earth overcurrent to verify action accuracy and response time
  4. Communication Test: Verify Modbus / IEC60870-5-103 / DNP3.0 data transmission
  5. Event Record Check: Confirm complete event & fault waveform records after fault triggering
  6. Règles de sélection & Quick Reference

Selection Mnemonic

Schneider P127 relay, full 3-phase earth protection,

Type B 1A earth input, V6 voltage 57-130V option,

D3 dual-port communication, FE0 with 8 relay operation,

24-250V wide power range, IP50 high protection graduation,

Order by P127BA0V6D3FE0, ideal for feeder station application.

Quick Selection Rules

  1. Current Input: A=5A standard CT; B=1A high precision; C=0.1A high-sensitivity earthing
  2. Voltage Module: V6=57-130V for PT secondary; Z1=24-60V for low voltage supply
  3. Communication: D3=dual-port local+remote; D1=single-port cost saving
  4. Sortir: FE0=8 relays standard; GE0=12 relays extended control
  5. Special Function: Suffixe “1” supports IRIG-B time synchronization
  6. Application: Feeder=standard; Motor=with directional; Transformer=with cold load pickup
  7. Air Freight Compliance & Certifications

Air Freight Compliance: No lithium battery / supercapacitor. Built-in electromagnetic components, compliant with IATA DGR Class 9 non-restricted goods, shippable as general cargo.

Certifications:

CE: CEI 60255, DANS 61010

UL: UL 1053 Power Protection Standard

ASC: Canadian electrical safety approval

CEI 60255 Functional Safety certified by TÜV Rheinland

RoHS: EU RoHS compliant, free of hazardous heavy metals

Environmental Compliance: REACH regulation compliant

  1. Achat & Logistics Info
ArticleDétails
MOQ1 unité
Lead TimeStandard 8-10 semaines; Express 3-5 semaines
ConditionnementIndividual carton with manual, software CD and communication cable
Garantie12 months after commissioning acceptance
Recommended SparesSame model relay, relay output module, module de communication
Accessoires assortisMiCOM S1 Studio, CT/PT, disjoncteur, communication switch

Schneider MiCOM Protection Relay Full Series List (Structured Version)

Schneider MiCOM protection relays consist of 8 platform series: Px10 / Px20 / Px30 / Px40 / Px60 / Px70 / Px80 / Px90. Covers feeder / moteur / transformateur / générateur / jeu de barres / line distance / differential protection. Supports Modbus / IEC60870-5-103 / DNP3.0. Applicable from medium-low voltage up to EHV power systems. Part number rule: PXXX[Code de fonction][Module Code].

  1. Naming Rule Definition
SegmentSignificationExemple
P.Protection Relay identifierP.
XXXCode de série:P127 (Feeder), P241 (Moteur)
P1xx: Feeder Protection
P2xx: Moteur & Rotating Machine
P3xx: Generator
P4xx: Line Distance
P6xx: Différentiel (Transformer/Motor/Busbar)
P7xx: Busbar Protection
P8xx: Circuit Breaker Failure
P9xx: Voltage/Frequency Control
Code de fonctionSpecial function:B=1A Earth; A1=IRIG-B
A/B/C: Earth current 5A/1A/0.1A
A0/A1: Standard / with IRIG-B
Module CodeFunctional module:V6, D3, FE0
V6/Z1: 57-130V / 24-60V
D1/D3/D5: Single/Dual-port/Ethernet
FE0/GE0/HE0: 8/12/16 relais
Full Part No.Global unique codeP127BA0V6D3FE0
  1. Series Classification by Application

2.1 Feeder Protection (P1xx)

SérieModèleFonction principaleCurrent InputVoltage ModuleComm.SortirTypical Part No.
Px10 BasicP111/P115/P116Surintensité + Earth Fault, Self-powered5A/1ANone/OptionalNone/D14-6R.P111A00V0D0FE0
Px20 StandardP121/P122/P1273-stage O/C + 2-stage Earth + Direction + Auto-reclose5A/1A/0.1AV6/Z1D1/D3FE0/GE0P127BA0V6D3FE0
Px30 AdvancedP132/P139/P138Feeder Management + ATS + Remote I/O5A/1AV6/Z1D3/D5GE0/HE0P132AA0V6D5GE0
Px40 High-EndP141/P142/P143Full feeder protection + Comptage d'énergie + Fault Recorder5A/1AV6/Z1D3/D5HE0P141CA0V6D5HE0

2.2 Moteur & Rotating Machine (P2xx)

SérieModèleFonction principaleType de moteurSpecial FunctionNuméro de pièce. Exemple
Px20P211Motor Monitoring + Surcharge + Locked Rotor + Phase LossLV MotorTemperature MonitoringP211A00V0D0FE0
Px40P241/P242/P243Integrated Motor Protection + Start Control + Diagnostic des pannesMV/HV MotorPositive/Negative Sequence + Thermal ModelP242AA0V6D3GE0
SpécialP244Synchronous Motor Protection + Excitation ControlMoteur synchroneOut-of-step + Excitation MonitoringP244BA0V6D3GE0

2.3 Protection du transformateur (P6xx)

SérieModèleFonction principaleTransformer TypeDifferential TypeNuméro de pièce. Exemple
Px30P631/P632/P633Transformer Differential + O/C + Earth + Température2-winding / 3-windingRatio DifferentialP632AA0V6D3GE0
Px40P635/P636/P637Advanced Transformer Protection + Winding Temp + BuchholzPower TransformerHarmonic Restraint Ratio DifferentialP635BA0V6D5HE0
RailwayP638Railway OHL Differential ProtectionTraction TransformerFast Differential + DirectionnelP638CA0V6D3GE0

2.4 Generator Protection (P3xx)

2.5 Line Distance Protection (P4xx)

2.6 Busbar Protection (P7xx)

2.7 Special Function Series

Précédent:

Laisser une réponse

Laisser un message