Schneider RXZE2M114M is a 14-pin mixed-type relay socket, specially designed for RXM2/RXM4 series miniature intermediate relays. It features 10A rated current, IP20 protection degree and wide operating temperature range, suitable for various industrial control applications. Its mixed terminal layout ensures flexible wiring, and dual mounting modes fit different control cabinet designs. Approved with CE, UL, ...

  • Détails du produit

Schneider RXZE2M114M is a 14-pin mixed-type relay socket, specially designed for RXM2/RXM4 series miniature intermediate relays. It features 10A rated current, IP20 protection degree and wide operating temperature range, suitable for various industrial control applications. Its mixed terminal layout ensures flexible wiring, and dual mounting modes fit different control cabinet designs. Approved with CE, UL, CSA et autres certifications internationales, it can be shipped as ordinary goods by air without special formalities.

  1. Définition du code modèle
Segment de codeSignificationDescription
RXZSérie de produitsZelio Relay series relay sockets
E2Code de série2nd-generation standard socket, compatible with 2-pole & 4-pole RXM relays
M.Terminal ArrangementMixed layout, coil and contact terminals arranged alternately
114Configuration des contacts14 épingles, fits relays with 4 change-over contacts (4CO/4PDT) ou 2 change-over contacts (2CO/2PDT)
M.Regional StandardCompliant with RIS standard; differs from RXZE2M114 (SCR standard) in partial certification details

Full Product Name: Schneider Harmony Zelio RXZE2M114M Mixed-type 14-pin Relay Socket, compatible with RXM2/RXM4 relays, screw terminal connection, Montage sur rail DIN

  1. Spécifications techniques de base
CatégorieCaractéristiquesRemarques
Paramètres de base
Type de produitMixed-type relay socketMixed layout of coil and contact terminals
Compatible RelaysRXM2 (2CO, 8-épingle), RXM4 (4CO, 14-épingle), REXL seriesCompatible with standard Schneider Zelio relays
Pin ShapeFlat typeEnsures stable plug-in connection
Type de câblageM3 screw terminalsTightening torque ≤1 N·m
Paramètres électriques
Tension de fonctionnement nominale (Ue)≤250V AC/DCApplicable to most industrial control circuits
Conventional Free-air Thermal Current (je)10UNContinuous rated working current
Dielectric Strength2500VConforme à la CEI 61984
Degré de protectionIP20Finger-proof and dust-proof
Paramètres mécaniques
Méthode de montage35mm standard DIN rail clip-on / panel screw mountingDual installation options
Largeur27mmTaille compacte, gain de place
Poids net0.056kilosConception légère
Fils applicablesFil solide: 0.5~2,5 mm² (AWG20~14)Covers various wiring requirements
Stranded wire with ferrule: 0.25~2,5 mm² (AWG22~14)
Twin solid wire: 0.5~1.5mm² (AWG20~16)
Twin stranded wire with ferrule: 0.25~1mm² (AWG22~17)
Paramètres environnementaux
Température de fonctionnement-40°C ~ +55°CWide temperature range for harsh industrial environments
Température de stockage-40°C ~ +85°CSuitable for transportation and storage
CertificationsCE, UL, ASC, Lloyd’sMeets major international safety standards
Ordering Info
Numéro de pièceRXZE2M114MUnique product model
Minimum Order Qty10 pcsStandard packing quantity
Modèle alternatifRXZE2M114 (SCR standard)Same function, different certification standards
  1. Défauts courants & Maintenance Solutions

3.1 Dépannage

Phénomène de défautCauses possiblesSolutions
Relay cannot be inserted/removed1. Deformed socket pins1. Straighten pins gently with tweezers
2. Oxidized/dirty relay pins2. Clean pins with anhydrous alcohol
3. Distorted socket caused by over-tight installation3. Adjust installation tightness and reinstall
Mauvais contact / signal interruption1. Loose wiring terminals1. Retighten terminals within 1 N*m torque
2. Oxidized/burned contacts2. Polish contacts gently with metallographic sandpaper
3. Deformed internal terminals3. Inspect and replace defective socket
Abnormal overheating1. Overload operation over 10A1. Replace higher-capacity socket or split load
2. Large contact resistance at terminals2. Re-crimp wires for better contact
3. Température ambiante trop élevée3. Improve ventilation and lower temperature
Reduced insulation performance1. Dust and oil accumulation1. Clean socket surface regularly
2. Insulation aging under long-term high temperature2. Replace aged sockets timely
3. Chemical corrosion3. Use anti-corrosion sockets or protective covers

3.2 Daily Maintenance Recommendations

  1. Inspection régulière: Check terminal tightness every 3 mois
  2. Nettoyage: Remove dust with compressed air every 6 mois, wipe surface with anhydrous alcohol if needed
  3. Preventive Replacement: Replace sockets every 2-3 years in high-temperature, high-humidity or corrosive environments
  4. Règles d'installation: Avoid mechanical shock and vibration; ensure full fitting between socket and relay; keep ≥5mm gap between adjacent sockets for heat dissipation
  5. Conseil de sélection: Réserve 20% current margin according to resistive/inductive loads to avoid overload
  6. Full RXZE2 Series Model List
ModèleDisposition des bornesPin CountCompatible RelayCaractéristiquesApplication
RXZE2M114MMixte14RXM2(2CO), RXM4(4CO)RIS standard, bornes à visContrôle industriel général, flexible wiring
RXZE2M114Mixte14RXM2(2CO), RXM4(4CO)SCR standard, bornes à visSame function, different certifications
RXZE2S114MSeparated14RXM4(4CO)Separated coil & contact terminalsLogic control circuit, anti-interférence
RXZE2S111MSeparated11RXM3(3CO)For 3-pole relaysSpecial control such as star-delta starting
RXZE2S108MSeparated8RXM2(2CO)For 2-pole relaysCompact control circuits
RXZE2M108MMixte8RXM2(2CO)Mixed 8-pin designCompact control boxes
  1. Cross-brand Comparison
MarqueModèleMontagePrix(USD)Compatibilité
SchneiderRXZE2M114MDIN Rail/Panel6.23RXM2/RXM4 series
OmronPYFZ-014Rail DIN5.8Partial fit for RXM, fits MY4
Siemens3RH2911-1FA22Rail DIN7.5Limited compatibility with 3RT series
ABBCR-M14SRail DIN6.9Partial fit for CR-M series
IDECSH4B-05BRail DIN6.1Good mechanical compatibility with RH4B
PhoenixPLC-RSC-24DC/21-21Rail DIN8.2Low cross-brand compatibility

Replacement Suggestion

  1. Compatibilité totale: Adopt original Schneider RXZE2M114 / RXZE2M114M
  2. Cost-effective alternative: Omron PYFZ-014, IDEC SH4B-05B
  3. Note: Verify terminal wiring diagrams before replacement to avoid wiring errors
  4. Conformité des expéditions aériennes & Certifications

6.1 Shipment Regulation

Conclusion: Pure electromechanical component, no built-in lithium battery or super capacitor, non-dangerous goods

Classe d'expédition: Ordinary cargo, no UN38.3 test or dangerous goods packaging required

Packaging Advice: Pack individually with anti-static bag; use hard carton for anti-deformation; separate bulk goods with partition boards

6.2 Main Certifications

CertificateStandardStatutZone Applicable
CEEN/IEC 61984CompliantEU & EEA
ULUL 508CompliantNorth America
ASCCSA C22.2 No.14CompliantCanada
Lloyd’sMarine StandardCompliantMarin & offshore engineering
RoHS2011/65/EUCompliantGlobal environmental compliance

6.3 Certification Inquiry Way

  1. Search RXZE2M114M on official Schneider website
  2. Check certification marks on product labels and packages
  3. Obtain full certification documents via Schneider technical support
  4. Application & Guide de sélection

7.1 Scénarios applicables

Automatisation industrielle: Extension de sortie API, électrovanne & contactor control

Contrôle du moteur: Star-delta starting, forward/reverse rotation, protection contre les surcharges

Électricité du bâtiment: Éclairage, air conditioning and fire linkage control

Marine engineering: Marine electrical control with Lloyd’s approval

Process control: Sensor signal amplification, actuator drive control

7.2 Unrecommended Scenarios

Severe high-vibration working conditions without shockproof measures

Strong corrosive environment such as chemical plants and salt fog areas

Working current exceeding 10A rated value

High-frequency switching over 10 times per second

7.3 Étapes de sélection

  1. Confirm relay model: RXM2 (2CO 8-pin) / RXM4 (4CO 14-pin)
  2. Choose socket type: Mixte (M.) / Separated (S)
  3. Confirm pin quantity: 8-pin /14-pin
  4. Select standard: RIS (M suffix) / SCR standard
  5. Confirm mounting method: DIN rail or panel mounting