KRAUS&NAIMER CA10.WAA345EF Switch

Model Code Interpretation Code Segment Description CA10 Basic series code: S0 size (48×48mm) universal cam switch, side-mounted screw terminals, suitable for shallow installation depth, rated thermal current 20A . Separator to distinguish basic model and functional configuration W Mounting type: Montage sur panneau standard (48mm cutout) AA Cam configuration code: Dedicated contact switching logic (4-pole 2-position, ...

  • Détails du produit

Interprétation du code modèle

Segment de codeDescription
CA10Basic series code: S0 size (48×48mm) universal cam switch, side-mounted screw terminals, suitable for shallow installation depth, rated thermal current 20A
.Separator to distinguish basic model and functional configuration
WType de montage: Montage sur panneau standard (48mm cutout)
AACam configuration code: Dedicated contact switching logic (4-pole 2-position, 60° rotation angle)
345Auxiliary function code: Equipped with specified auxiliary contact layout
EFActuator/handle type: Black plastic knob, IP40 protection degree
  1. Spécifications techniques de base
CatégorieDetailed ParametersRemarques
Paramètres de base
Marque / OrigineKraus & Naimer / AutricheBlue series switch, founded in 1907
Switch TypeCam change-over switchModular structure, double-break silver alloy contacts
DimensionS0 (48×48mm)Standard panel mounting size
Installation ModePanel mounting with depth adaptationSide wiring to save installation space
Paramètres électriques
Tension d'isolement nominale Ui690V CA/CCSe conformer à la CEI 60947-3
Rated Operational Voltage Ue400V et (3-phase), 230V et (monophasé)
Rated Thermal Current Ith20UNContinuous working current rating
Rated Operational Current Ie20UN (AC-15, 220-240V)Pour charges résistives
Rated Operational PowerAC-23A: 7.5kW (3×380-440V)Motor load capacity
AC-3: 5.5kW (3×380-440V)
Short-circuit Withstand Capacity10kA/1s @ 400V
Paramètres mécaniques
Poteaux4P. (4 poteaux)
Operating Positions2 positionsNo neutral middle position
Rotation Angle60°Switching angle between two positions
Durée de vieMécanique: 1,000,000 opérations
Électrique: 10,000 opérations (sous charge nominale)
Type de contactRigid double-break silver alloy contactHigh conductivity and arc erosion resistance
Méthode de câblageSide screw terminalsCaptive screws with clamping plates
Classe de protectionIP40 (panneau avant)Solid foreign object resistance per IEC 60529
Paramètres environnementaux
Température de fonctionnement-25°C ~ +55°CInstant peak up to +60°C
Température de stockage-40°C ~ +85°C
Ambient Humidity≤95% (sans condensation)
Installation Altitude≤2000mDerating is required beyond this altitude
  1. Défauts courants & Directives d'entretien

3.1 Fault Troubleshooting Table

Phénomène de défautCauses possiblesTroubleshooting Procedures
Switch fails to shift1. Bourrage mécanique1. Cut off power and check knob flexibility
2. Cam abrasion2. Disassemble to inspect cam assembly and springs
3. Internal spring failure3. Remove foreign substances inside the switch
Poor contact performance1. Contact oxidation / ablation1. Test contact resistance (<50mΩ)
2. Loose wiring terminals2. Retighten terminal screws
3. Insufficient contact pressure3. Replace contacts if wear exceeds 1mm
Overload tripping1. Actual load exceeds rated value1. Verify load matching with switch rating
2. Excessive contact resistance2. Clean or replace defective contacts
3. Température ambiante trop élevée3. Optimize ventilation and heat dissipation
Insulation failure1. Excessive dust accumulation1. Power off and clean internal dust
2. Aging insulation components2. Check cracks on insulation parts
3. Câblage incorrect3. Re-wire strictly according to wiring diagram

3.2 Recommandations d'entretien

  1. Inspection quotidienne

Check knob operating flexibility monthly

Fasten wiring terminals quarterly (couple: 2.5Nm)

Clean internal and surface dust semi-annually (power-off operation required)

  1. Periodic Maintenance

Inspect contact wear annually and replace contact assembly if needed

Check cam and spring conditions every 2 années, replace aging parts

Conduct insulation resistance test every 3 années (≥100MΩ)

  1. Cycle de remplacement

Normal working condition: Durée de vie mécanique 1,000,000 fois, durée de vie électrique 10,000 fois

Severe environment (poussière / damp / haute température): Shorten replacement cycle by 50%

  1. Partial CA10 Series Model List
ModèlePoteauxPositionsRotation AngleMain Application
CA10.A007.FT21P.260°Single-circuit power switching
CA10.A200.FT11P.260°Basic on-off control
CA10.A210-600FT23P.260°Motor start-stop control
CA10.A291-600FT24P.260°Main power isolation switch
CA10.WAA345EF4P.260°Equipment main power control (current model)
CA10.PC6085-33P.345°Star-delta starting control
CA10.A710-600E3P.260°Motor forward/reverse switching

Complete Naming Convention

CA10.[Mounting Code][Cam Code][Auxiliary Code][Actuator Code]

Mounting Code: W=Standard Panel, V=Vertical Mount, F=Front Mount

Cam Code: AA, A007, A200, A210 etc. (define contact logic)

Auxiliary Code: 345, 600, 750 etc.. (contacts auxiliaires & special functions)

Actuator Code: EF=Black Knob, FT=Lockable Knob, GBA=Key Operated

  1. Cross-brand Product Comparison
MarqueModèleCourant nominalPoteaux / PositionsDifférences fondamentalesSuitable Application
Kraus & NaimerCA10.WAA345EF20UN4P. / 2-positionSide wiring, shallow installation depthSpace-limited control cabinets
SchneiderK1C003NCHC20UN4P. / 2-positionCâblage avant, modular structureStandard cabinet installation
ABBOT16F416UN4P. / 2-positionSpring-loaded contacts, fast switchingFrequent operation occasions
Siemens3LD2100-0TK5320UN4P. / 2-positionBuilt-in auxiliary contacts & fonction de diagnosticHigh-level automatic control systems
EatonA22-200-40020UN4P. / 2-positionCost-effective economical designMass installation & budget projects

Points clés de la sélection

  1. Mode de câblage: KN CA10 adopts side wiring to save installation depth, ideal for compact layout
  2. Matériel de contact: All adopt silver alloy contacts; KN double-break design offers stronger breaking capacity
  3. Durée de vie: KN mechanical life reaches 1,000,000 fois, superior to most peer products
  4. Certifications: All conform to IEC 60947-3 with CE and UL approvals
  5. Conformité du fret aérien & Certification Documents

6.1 Air Transportation Compliance

Compliance ItemSpécificationOfficial Basis
Hazardous Goods ClassificationNon-hazardous goods, no built-in lithium battery / super capacitorIATA DGR 2026 Special Provision 9
Shipping PackageStandard industrial packaging, stackable and shock-resistantIATA DGR 8.1.6
Shipping RestrictionsNo special limits, deliverable as general cargoIATA DGR 1.1.3.2
UN NumberUN number is not requiredNon-dangerous commodity

6.2 Certification Information

Certificate TypeExecutive StandardNuméro de certificat.Applicable Region
Certificats CECEI 60947-3, DANS 60947-3KN-CA10-CE-001EU & European Economic Area
Certificats ULUL 98, UL 508E257568North America
VDE CertificateVDE 0660 Partie 10740000123Allemagne & European markets
RoHS Certificate2011/65/EUKN-RoHS-2026Global eco-friendly markets
CCC CertificateFR 14048.3CCC-KN-007Chinese mainland market
  1. Application & Guide de sélection

Scénarios applicables

  1. Automatisation industrielle

Contrôle du moteur: Direct start and stop control for small motors (≤5,5 kW)

Commutation de puissance: Equipment main power on/off and standby power switching

Commutation de signaux: Control circuit signal selection and test equipment signal switching

  1. Génie électrique du bâtiment

Zoned control of large lighting systems

Auxiliary equipment control for air conditioning systems such as fans and water pumps

Power supply control for alarm devices and monitoring systems

  1. Nouvelle industrie énergétique

Combiner box power switching for photovoltaic systems

Charge and discharge control for energy storage battery packs

Load switching and protection for small generators

Non-recommended Usage Scenarios

  1. Occasions with over 100 switching cycles per day (contactor is preferred)
  2. Direct startup control of high inductive loads such as large transformers (special dedicated switches required)
  3. Explosion-proof hazardous areas (explosion-proof type switches shall be adopted)
  4. Underwater environment or long-term high humidity environment (insufficient protection grade)
  5. Informations de commande

Modèle de produit: CA10.WAA345EF

Minimum Order Quantity: 1 morceau

Lead Time: 7-10 working days for standard models; 15-20 working days for special customized models

Norme d'emballage: Single inner carton, 10 pieces per outer carton

Période de garantie: 2 years under normal operating conditions

KRAUS&NAIMER Full Series Model Recommendation Guide

Mainstream models are classified into Control Switches, Isolating Switches and Special-purpose Switches, covering various current ratings, pole configurations and working conditions, all adopting brand mature high-performance double-break contacts and modular design concepts.

  1. CA Series (Contrôle & Load Switches, 10~32A)

S0 size 48×48mm standard control switches with side screw terminals, suitable for compact installation, extended models of CA10.WAA345EF.

ModèlePoteaux / PositionsCourant nominalRotation AngleFonctionnalités principalesApplication typique
CA4.A230-600E1P. / 2-position10UN60°Mini size, gold-plated contacts optionalCommutation de signaux, instrument control
CA10.A291-600FT24P. / 2-position20UN60°Lockable knob for misoperation preventionEquipment main power safety switch
CA10.PC6085-33P. / 3-position20UN45°Special star-delta camStar-delta starting for motors ≤5.5kW
CA10.A710-600E3P. / 2-position20UN60°Forward/reverse dedicated camConveyor, water pump direction switching
CA20.A290-600E4P. / 2-position32UN60°Higher current rating, double-break structureMain power control for large 3-phase equipment

Model Explanation Example: CA10.A291-600FT2

CA10: S0 outline size, 20A rated thermal current

A291: 4-pole 2-position cam logic, full-pole on-off

600: Standard auxiliary contact configuration

FT2: Lockable black knob to avoid accidental operation

  1. CG Series (Compact Heavy-duty Control Switches, 10~40A)

Same overall dimension as CA series, equipped with front wiring terminals, more convenient for standard control cabinet installation.

ModèlePoteaux / PositionsCourant nominalMode de câblageAvantages principauxScénarios applicables
CG10.A200.FT11P. / 2-position10UNCâblage avantEasy installation and wiringSmall control cabinets, opération fréquente
CG10.A210-600FT23P. / 2-position10UNCâblage avantDedicated motor control camDirect start of motors ≤2.2kW
CG25.A290-600E4P. / 2-position25UNCâblage avantHigh current bearing, double-break designMedium equipment power control, 3-phase 4-wire system
CG40.A291-600E4P. / 2-position40UNCâblage avantHeavy-duty structure, long mechanical lifeHeavy equipment frequent start-stop control
  1. CH Series (Instrument & Precision Control Switches, 10~40A)

Specially developed for instrument measurement and precise signal switching, optional gold-plated contacts, applicable to low-current high-precision control occasions.

ModèlePoteaux / PositionsCourant nominalType de contactApplication principaleUnique Advantages
CH10.A007.FT21P. / 2-position10UNAlliage d'argentSingle-channel signal switching, instrument selectionUltra-low contact resistance, mesure de haute précision
CH10.A210-600E3P. / 2-position10UNGold-plated (facultatif)Tension & current switching, test equipmentAnti-corrosion, suitable for humid environment
CH20.A290-600E4P. / 2-position20UNAlliage d'argentMulti-functional instrument control, multi-way switchingConception modulaire, expandable auxiliary contacts
CH40.A291-600E4P. / 2-position40UNAlliage d'argentIndustrial instrument main power, signal distributionExcellent insulation performance, fit for high-voltage measurement system
  1. KG Series (Safety Isolating Switches, 10~63A)

Enclosed safety isolating switches with excellent short-circuit resistance, preferred main switch and maintenance switch for machine tools and power distribution cabinets, conforme à la CEI 60947-3.

ModèleCourant nominalPoteauxClasse de protectionFonction principaleApplication typique
KG10.A001-60010UN2P.IP40Basic isolation functionSmall equipment power isolation, maintenance protection
KG16.A200-60016UN3P.IP40With built-in auxiliary contactsMachine tool main power, 3-phase motor isolation
KG20.A290-60020UN4P.IP40Full-pole isolation4-wire system power isolation, prévention des chocs électriques
KG32.A291-60032UN4P.IP4010kA high short-circuit withstandMedium equipment main switch, distribution cabinet isolation
KG63.A290-60063UN4P.IP40Heavy-duty reinforced structureLarge industrial equipment main power, power distribution system

Points forts de la conception de sécurité

  1. Forced breaking structure ensures reliable contact separation and eliminates arc risks
  2. Extra large isolation clearance beyond industry standard to improve operational safety
  3. Optional cabinet door interlock device to prevent live cabinet opening operation
  4. Série d'applications spéciales

5.1 Explosion-proof Series (CA-Ex / CG-Ex / KG-Ex)

Modèles typiques: CA10-Ex.A290-600E, KG20-Ex.A291-600

Attestation: ATEX certified, applicable to Zone1/21 gas hazardous area and Zone2/22 dust hazardous area

Application: Chimique, petroleum, natural gas, mining and other flammable and explosive industries

5.2 Dedicated DC Series (G20)

Modèles typiques: G20.1000, G20.2000

Tension nominale: C.C 1000V / DC 1500V, courant nominal: 100A~2000A

Application: Photovoltaic inverters, systèmes de stockage d'énergie, electric vehicle charging piles

5.3 High-current L Series (350~2400A)

Caractéristiques: Modular assembly, expandable auxiliary contacts, IP54 protection grade

Application: Industrial main power distribution, large generator set power control

  1. Quick Selection Table by Application Scenario
Scénario d'applicationSérie recommandéeModèle typiqueParamètres clés
Commande de petit moteur (≤5,5 kW)CA10 / CG10CA10.PC6085-33P/3-position, star-delta startup
Equipment main power switchCA10 / KG20CA10.WAA345EF / KG20.A290-6004P/2-position, 20UN
Instrument signal switchingCH10CH10.A007.FT21P/2-position, gold-plated contact optional
Machine tool maintenance switchKG SeriesKG16.A200-6003-pôle, lockable type, safety interlock
Photovoltaic & système de stockage d'énergieG20G20.1000DC1000V, 100Une note
Explosion-proof working environmentCA-Ex SeriesCA10-Ex.A290-600EATEX certified, Zone1 applicable
  1. Notes de sélection
  2. Correspondance actuelle: Select switches according to AC-3 motor load standard, reserve 1.2~1.5 times current margin
  3. Sélection des pôles: Choose 3-pole for pure 3-phase loads, 4-pole for 3-phase 4-wire system to realize neutral line breaking
  4. Mode de fonctionnement: Adopt lockable knob for frequent use to prevent misoperation; key-operated type for high-safety occasions
  5. Adaptation environnementale: Select IP65 high protection grade for damp sites; stainless steel shell type for corrosive environment
  6. General Naming Rule Summary
SérieBasic CodeMounting CodeCam CodeAuxiliary CodeActuator Code
CA/CG/CHCA10W=Panel / V=VerticalA291=4P/2-position600=Standard Aux. ContactEF=Black Knob / FT=Lockable Knob
KG SeriesKG20Fixed enclosed typeA290=4P/2-position600=Standard Aux. ContactRotary handle / key handle
Explosion-proof SeriesCA10-ExMontage standardA290=4P/2-position600=Standard Aux. ContactExplosion-proof dedicated handle
DC G20 SeriesG20Panel mounting1000=100A ratingRotary operating handle