Straight 4m cable: YF8U14-040VA3XLEAX Straight 5m cable: YF8U14-050VA3XLEAX Connector base: STE-0804-G (terminal block for control cabinet wiring) Installation complète & Commissioning Manual for SICK WTB8-P2231 Photoelectric Sensor (Order No.6033209) Basic Model Information Complete Model No.: WTB8-P2231 Official Order No.: 6033209 Série: W8 Ultra-compact Diffuse Photoelectric Sensor with Background Suppression Origin: China Standard Accessories: Acier inoxydable ...

  • Détails du produit

Straight 4m cable: YF8U14-040VA3XLEAX

Straight 5m cable: YF8U14-050VA3XLEAX

Connector base: STE-0804-G (terminal block for control cabinet wiring)

Installation complète & Commissioning Manual for SICK WTB8-P2231 Photoelectric Sensor (Order No.6033209)

  1. Informations de base sur le modèle

Complete Model No.: WTB8-P2231

Numéro d'ordre officiel: 6033209

Série: W8 Ultra-compact Diffuse Capteur photoélectrique with Background Suppression

Origine: Chine

Accessoires standards: Stainless Steel Mounting Bracket BEF-W100-A

Répartition du code modèle

  1. WT: Diffuse reflective photoelectric sensor
  2. B: Equipped with background suppression function
  3. 8: W8 miniature housing (11×31×20mm)
  4. P.: Sortie PNP
  5. 22: M8 straight 4-pin connector, red LED light source
  6. 31: 4-turn potentiometer adjustment, Light-on / Dark-on switchable
  7. Core Optical Specifications
Élément de paramètreSpécification
Principe de détectionDiffuse reflection + suppression de l'arrière-plan
Source de lumièreVisible red LED, 650nm
Standard Sensing Range40~300mm (90% high-reflective white paper)
Minimum Suppression Distance30mm (Filters background at close range)
Spot Size at 300mmΦ20mm
Méthode d'ajustement4-turn precision potentiomsicketer
Mode de fonctionnementSwitchable Light-on / Dark-on

III. Spécifications électriques

  1. Alimentation: C.C 10 ~ 30 V, ripple ±10%
  2. Sortir: PNP open collector, maximum. load 100mA
  3. Courant de repos: ≤30mA
  4. Temps de réponse: ≤0,5 ms
  5. Fréquence de commutation: 1000Hz (for high-speed object detection)
  6. Protection: Reverse polarity, surintensité & triple protection contre les courts-circuits
  7. Durée de vie: 100,000 hours for LED light source (25℃)
  8. M8 4-Pin Wiring Definition (Straight Connector)

Pin color & fonction (industry standard 4-core cable):

  1. BN Brown: DC24V+ (L+)
  2. WH White: Unused pin (no connection)
  3. BU Blue: 0V Negative (M/GND)
  4. BK Black: PNP signal output Q
  5. Mécanique & Spécifications environnementales

Dimensions: W11mm × H31mm × D20mm

Poids: Only 10g

Matériau du boîtier: ABS plastic; optical window: PMMA

Classe de protection: IP67 (dustproof, temporary water immersion resistant)

Température de fonctionnement: -25℃ ~ +55℃

Température de stockage: -40℃ ~ +70℃

Montage: Fixed via symmetric M3 threaded holes on both sides

  1. LED Indicator Description
  2. LED verte: Steady on = Normal power supply; Flashing = Unstable detection
  3. Orange LED: Illuminated = Sensor output activated (object detected)

VII. Avantages principaux

  1. Powerful Background Suppression: Eliminates interference from metal frames, bandes transporteuses, walls and other backgrounds, ensures stable detection for black & white workpieces
  2. Ultra-compact Size: Easy installation in narrow equipment, pipeline modules and robot grippers
  3. Réponse à grande vitesse: Ideal for packaging, sorting and small parts counting
  4. IP67 dust & résistance à l'eau, stable operation in oily & humid workshop conditions
  5. 4-turn potentiometer enables high-precision fine-tuning for minor distance adjustments

VIII. Scénarios d'application typiques

Presence detection of materials on packaging production lines

Compte & position confirmation of small hardware/plastic components

Leakage prevention detection of products on conveyor belts

Workpiece positioning inside electronic equipment

Sorting small items in logistics systems

  1. Alternative / Distinct Models in the Same Series
  2. WTB8L-P2231: Laser version with identical housing, smaller light spot for high-precision long-distance detection
  3. WTB8-N2231: NPN output variant (for PLC negative common input)
  4. WTB8-P1301: M8 elbow cable outlet, for space-limited installation
  5. WTB8-P2231V: Sanitary stainless steel housing (for humid food processing environments)
  6. Recommended Matching Cables

Table of Contents

  1. Consignes de sécurité
  2. Unboxing Standard Parts List
  3. Mechanical Installation Specifications (Bracket, Couple, Dimensions, Exigences d'autorisation)
  4. M8 4-Pin Electrical Wiring Definition & Wiring Procedures
  5. On-site Optical Alignment & Distance Adjustment Operations
  6. Light-on / Dark-on Mode Switching
  7. LED Indicator Status Explanation
  8. Environmental Installation Prohibitions & Exigences de protection
  9. Entretien courant & Cleaning Standards
  10. Matrice de dépannage
  11. Selection of Matching Cables & Des pièces de rechange
  12. Mandatory Safety Instructions
  13. Cut off DC24V power supply before wiring. Hot plug/unplug of M8 connector is forbidden to avoid breakdown of output chip.
  14. Rated power supply range is limited to DC 10~30V; AC220V or AC110V input is strictly prohibited, which will burn the sensor instantly.
  15. Max.. output load is 100mA. Direct driving of solenoid valves or contactors is forbidden; add relay isolation if high-power loads need to be driven.
  16. Drilling, grinding or disassembling the sensor housing is prohibited. Damaged IP67 seal will result in loss of dustproof and waterproof performance.
  17. Prevent strong light from directly irradiating the optical window (sunlight, welding arc, high-power spotlights), which causes false triggering and detection failure.
  18. Avoid heavy impact or dropping; offset internal optical path will permanently degrade detection stability.
  19. Unboxing Standard Parts List

Sensor Main Unit: WTB8-P2231 ×1

Standard Mounting Accessory: BEF-W100-A stainless steel bracket ×1

M3 mounting screws, flat washers & spring washers (supplied with bracket)

No factory-supplied cable; M8 4-pin straight cable shall be purchased separately

  1. Mechanical Installation Specifications

3.1 Dimensions hors tout

W11mm × H31mm × Depth 20mm; symmetric M3 internal threaded mounting holes on both sides.

3.2 Bracket Mounting Steps

  1. Secure BEF-W100-A bracket to equipment sheet metal or aluminum extrusion and pre-tighten screws.
  2. Clip the sensor into the bracket slot, align bilateral M3 holes, and pass through M3 bolt, flat washer and spring washer.
  3. Standard Tightening Torque: 1.8 Nm

Insufficient torque: Vibration causes sensor offset and light spot drift;

Excessive torque: Thread stripping, housing deformation and optical path misalignment.

  1. Fine-tune vertical & horizontal angles of the sensor to fully cover target surface with red light spot, then lock all bolts.

3.3 Installation Clearance Requirements (Critical for Background Suppression)

  1. Reserve a minimum clearance of 30mm between sensor optical window and fixed rear background; otherwise background interference leads to permanent false ON signal.
  2. Standard detection range: 40~300mm (90% high-reflective white object); 30~40mm is critical range susceptible to material interference.
  3. Do not place metal, mirror or high-reflective panels closely behind the sensor; intense diffuse reflection will disable background suppression.
  4. Pipeline installation: Align light spot to workpiece center, avoid conveyor joints, rollers and metal supports.
  5. Multiple sensors mounted side-by-side: Adjacent sensor spacing ≥50mm to prevent mutual red light crosstalk interference.

3.4 Permitted / Prohibited Installation Environments

✅ Permitted: Dry workshop, light dust, intermittent water spray (IP67 temporary water resistance), environment of -25℃~+55℃

❌ Prohibited: Continuous immersion, strong corrosive acid/alkali liquid, long-term cutting oil splash, temperature above +55℃ or below -25℃, areas beside heavy electromagnetic cabinets (onduleurs, high-power motors)

  1. Spécifications du câblage électrique

4.1 M8 4-Pin Straight Connector Fixed Pin Definition

Numéro de broche.Couleur du filFonctionInstructions de câblage
1BN BrownDC24V Positive L+Output terminal of switching power supply
2WH WhiteUnused PinLeave floating, do not connect to power or ground
3BU Blue0V Negative GNDPuissance négative & PLC common terminal
4BK BlackPNP Output QPLC digital input terminal (PNP high-level active)

4.2 Wiring Operation Steps

  1. Confirm power supply cut off, insert M8 connector straight into the slot at sensor tail, tighten thread clockwise without brute force.
  2. Route cables away from power cables and inverter output lines with separation ≥10cm to avoid electromagnetic interference.
  3. Cable bending radius ≥5× cable outer diameter; hard folding or long-term extrusion of cable root is forbidden.
  4. Fit a 4A slow-blow fuse in power circuit to protect sensor against short-circuit damage.

4.3 PNP Output Matching Instruction

Connect PLC input common terminal to 24V negative; connect black signal wire of sensor directly to PLC input point. No external pull-up resistor required.

  1. Optical Alignment & Distance Adjustment (4-turn Precision Potentiometer)

5.1 Alignment Operation

  1. Après la mise sous tension, green power LED stays steady; observe red light spot at front end.
  2. Adjust sensor angle to fully cover target workpiece without partial spot falling on background bracket.

5.2 Potentiometer Adjustment Flow (Background Suppression Calibration)

  1. Place target workpiece at maximum sensing distance (300mm), slowly turn potentiometer clockwise until orange output LED just lights up.
  2. Remove workpiece, orange LED must turn off; if it remains on, background interference exists — increase distance between sensor and background or fine-tune potentiometer counterclockwise.
  3. Repeat placing & removing workpiece for verification: LED lights when workpiece is present, extinguishes when absent, no frequent flashing means calibration completed.
  4. The potentiometer supports 4-turn adjustment with high fine-tuning precision; avoid excessive rotation each time.
  5. Light-on / Dark-on Mode Switching

Small toggle switch on sensor side:

L (Light-on): Output ON when light spot is blocked by object (orange LED illuminated), default mode for pipeline workpiece presence detection.

D (Dark-on): Output ON when no object exists; signal cut off when workpiece arrives, suitable for empty position & missing material alarm.

  1. Dual-Color LED Indicator Status Table
LED verte (Pouvoir)Orange LED (Sortir)Equipment StatusHandling Method
Steady ONDÉSACTIVÉNormal power, no object detectedNormal standby
Steady ONSteady ONObject detected, output activatedNormal detection
Steady ONFast flashingUnstable detection (background interference, over-range distance, spot offset)Recalibrate potentiometer & adjust mounting distance
DÉSACTIVÉAny StatusPas de puissance, broken wire or power failureInspect brown/blue wires, 24V power supply and fuse
FlashingAny StatusSous-tension / excessive power rippleReplace regulated DC24V power supply, reduce cable voltage drop
  1. Environmental Installation Protection Details
  2. Poussiéreux & oily workshops: Wipe optical window regularly to prevent oil & carbon deposit blocking optical path; spraying paint on sensor housing is prohibited.
  3. Humid/mist environments: Apply a thin layer of waterproof silicone grease on M8 connector thread to prevent moisture penetration into connector interior.
  4. Temperature Limits:

Plage de fonctionnement: -25℃ ~ +55℃

Stockage & Transportation Range: -40℃ ~ +70℃

Install simple baffles in high-temperature areas to block hot exhaust air from equipment.

  1. EMI Suppression: Use PVC shielded cable for sensor wiring, ground shield at single end; keep cables away from servo motors, contactors and inverters.
  2. Entretien courant & Nettoyage
  3. Cleaning Tools: Dust-free cloth, isopropyl alcohol (éthanol anhydre); steel wool, sandpaper, acetone and strong corrosive detergents are strictly forbidden.
  4. Wiping Sequence: Blow off dust first, gently wipe optical window with alcohol, power on after complete air-drying.
  5. Inspection Cycle:

Clean packaging line: Une fois par mois

Metal processing / heavy dust production line: Once per week

  1. Quarterly Inspection Items: Bracket screw torque, cable root cracking, loose connector and potentiometer offset.
  2. Matrice de dépannage
Phénomène de défautCause premièreStep-by-step Solutions
Green LED does not light up after power-on1. Reversed brown/blue wires; 2. No 24V power supply; 3. Connecteur desserré; 4. Internal short-circuit burnout1. Vérifier le câblage; 2. Test power with multimeter; 3. Retighten M8 connector; 4. Remplacer le capteur
Orange LED stays ON without any object1. Background clearance less than 30mm; 2. Over-adjusted potentiometer; 3. High-reflective metal at rear; 4. Switch set to D Dark-on mode1. Move sensor backward to reserve clearance; 2. Turn potentiometer counterclockwise; 3. Add black light-absorbing baffle; 4. Toggle switch to L Light-on
Orange LED does not light up with object present1. Sensing distance over 300mm; 2. Ultra-low reflectivity workpiece (solid black rubber); 3. Misaligned light spot; 4. Shorted output load1. Shorten mounting distance; 2. Turn potentiometer to maximum; 3. Realign light spot; 4. Disconnect load and test sensor independently
Orange LED flashes frequently & signal jitters1. Loose bracket due to equipment vibration; 2. Dust/oil covering optical window; 3. Light crosstalk between multiple sensors; 4. Forte fluctuation de la tension d’alimentation1. Retighten M3 bolts to 1.8Nm; 2. Clean optical window; 3. Widen spacing between sensors; 4. Replace regulated DC power supply
Signal de sortie intermittentBroken wire at bent root of M8 cable, oxidized connector due to water ingressReplace brand-new M8 connecting cable
  1. Recommended Matching Installation Cables (M8 4-Pin Straight)
  2. YF8U14-020VA3XLEAX 2m straight cable
  3. YF8U14-050VA3XLEAX 5m straight cable
  4. STE-0804-G M8 4-pin terminal base (for internal transition in control cabinet)