Siemens 3VA9267-0HA20 Molded Case Circuit Breaker

Model Code Interpretation Segment 3VA 9 267 -0HA 20 Meaning Product series: SENTRON 3VA molded case circuit breaker system Accessory category: 3VA9 series accessories Accessory type: MO320 Front-mounted Motor Operator Control voltage code: 110-230V et / 110-250V DC Applicable breaker rating: 3VA2 100/160/250A Description Flagship low-voltage power distribution series of Siemens, covering MCCBs from 16A ...

  • Détails du produit

Interprétation du code modèle

Segment3Virginie9267-0HA20
SignificationSérie de produits: SENTRON 3VA molded case circuit breaker systemAccessory category: 3VA9 series accessoriesAccessory type: MO320 Front-mounted Motor OperatorControl voltage code: 110-230V et / 110-250À DCApplicable breaker rating: 3VA2 100/160/250A
DescriptionFlagship low-voltage power distribution series of Siemens, covering MCCBs from 16A to 1600AAccessory system specially designed for 3VA series circuit breakersMO320 motor operator, supporting remote closing and trippingConception à large tension, compatible with various power supply systemsSuitable for 3VA2 circuit breakers rated at 100A, 160A and 250A
  1. Principales spécifications techniques
Catégorie de paramètreDonnées techniquesRemarques
General Information
Nom du produitMO320 Front-mounted Motor OperatorFor 3VA2 series molded case circuit breakers
Numéro de commande.3VA9267-0HA20Standard commercial model
Statut du produitActive (PM300)Defined by Siemens Product Lifecycle Management System
Paramètres électriques
Tension de contrôle110-230V et (50/60Hz) / 110-250À DCLarge compatibilité de tension
Rated Apparent Power250VirginiePower consumption of the operator
Operating Time (Clôture & Tripping)Typical 1 deuxièmeMechanical response time
Paramètres mécaniques
Dimensions (L×H×P)105mm×75mm×132mmCompact design to save cabinet space
PoidsEnviron. 846gEasy for installation and maintenance
Terminal CapacityFor 1.5-2.5mm² conductorsSolide, stranded and fine-stranded conductors applicable
Wire Stripping Length7mmConforme aux normes CEI
Couple de serrage0.36-0.44N·mEnsure reliable connection
Paramètres environnementaux
Température de fonctionnement-25°C à +70°CSuitable for industrial environments
Température de stockage-40°C à +80°CWide temperature range for storage
Protection contre la pénétrationIP30Conforme à la CEI 60529
  1. Full Range of MO320 Motor Operators
ModèleTension de contrôleApplicable Breaker SeriesRemarques
3VA9267-0HA1024-60À DC3VA2 100/160/250Low voltage DC type
3VA9267-0HA20110-230V et / 110-250À DC3VA2 100/160/250Universal wide voltage type (Current Model)
3VA9157-0HA1024-60À DC3VA1 100/160For 3VA1 series
3VA9157-0HA20110-230V et / 110-250À DC3VA1 100/160For 3VA1 series
3VA9467-0HA1024-60À DC3VA2 400/630For high-current 3VA2 breakers
3VA9467-0HA20110-230V et / 110-250À DC3VA2 400/630For high-current 3VA2 breakers
3VA9257-0HA1024-60À DC3VA2 100/160Side-mounted type
3VA9257-0HA20110-230V et / 110-250À DC3VA2 100/160Side-mounted type
  1. Concurrent & Equivalent Model List
MarqueModèleApplicable BreakerTension de contrôleDescription du remplacement
Siemens3VA9267-0HA103VA2 100/160/25024-60À DCLow-voltage alternative within the same series
Schneider ÉlectriqueLV432642NSX 400-630380-415V etFunctional cross-brand replacement
ABBCD2-400T1-T6 Series220V CA/CCFunctional cross-brand replacement
ABBOTM-D250Tmax Series24-250V CA/CCFunctional cross-brand replacement
EatonNZM-E200NZM Series24-230V CA/CCFunctional cross-brand replacement
  1. Application Environments & Cas industriels

5.1 Scénarios d'application recommandés

Systèmes d'automatisation industrielle: Remote closing and tripping of motor circuits for production line automatic control

Centres de données: Remote operation of breakers for UPS systems to improve power supply reliability

Bâtiments commerciaux: Remote control of breakers for emergency lighting and fire protection systems, complying with safety regulations

Infrastructures énergétiques: Remote monitoring of breakers for photovoltaic inverters and energy storage systems to boost operation efficiency

Water Treatment Facilities: Automatic switching of pump circuits to realize unattended operation

5.2 Scénarios non recommandés

Explosive Hazardous Areas: Additional explosion-proof certification is required; not suitable for direct use in IIC explosive zones

High Electromagnetic Interference Environments: Extra electromagnetic shielding is needed; not recommended near unshielded high-frequency equipment

Severe Vibration Environments: Not applicable where vibration acceleration exceeds 5g, which may impair mechanical reliability

5.3 Cas d'application typiques

Cas 1: Automobile Manufacturing Plant

Application: Remote control of power circuits for welding robots

Configuration: 3VA2 250A MCCB + 3VA9267-0HA20 Motor Operator + PLC Control System

Avantages: Realize automatic power-off protection for production lines, reduce manual operation and increase productivity by 15%

Cas 2: Large-scale Data Center

Application: Remote management of Power Distribution Units (PDU) in server cabinets

Configuration: 3VA2 160A MCCB + 3VA9267-0HA20 + Building Management System (BMS)

Avantages: Remote monitoring and circuit switching, quick fault isolation; Mean Time To Repair (MTTR) reduced to less than 5 minutes

Cas 3: Hospital Operating Room

Application: Emergency control of dedicated power circuits for medical equipment

Configuration: 3VA2 100A MCCB + 3VA9267-0HA20 + Emergency Control System

Avantages: Fast power switching for operating rooms, ensure safe operation of medical devices; conforme à la CEI 60601 medical standards

  1. Conseils de sélection & Quick Reference Rules

Selection Rhythm (For Reference)

Model 3VA9267-0HA20,

Couvertures 110 to 230V AC/DC,

Matches 3VA2 100/160/250A breakers,

Front-mounted MO320 design,

One second for remote switch action,

Rated power at 250VA,

Dimension 105×75×132mm,

Ideal for industrial and building applications.

Quick Reference Rules

  1. Correspondance de tension: HA20 = Wide voltage (110-230V et / 110-250À DC); HA10 = Low voltage (24-60À DC)
  2. Série applicable: 9267 = 3VA2 100/160/250A; 9157 = 3VA1 100/160A; 9467 = 3VA2 400/630A
  3. Type de montage: 9267 = Front-mounted; 9257 = Side-mounted
  4. Paramètres de base: 1-second operating time, 250VA power rating, compatible with 1.5-2.5mm² conductors
  5. Dépannage & Solutions
Phénomène de défautCauses possiblesSolutions
Failure to close or tripTension de commande anormaleVerify the voltage is within 110-230V AC / 110-250À DC
Loose wiring terminalsRetighten terminals with torque of 0.36-0.44N·m
Bourrage mécaniqueCheck connection between operator and breaker, remove foreign objects
Slow closing/trippingInsufficient power supply capacityEnsure control circuit power ≥ 250VA
Excessively low ambient temperatureApply heating measures when temperature is below -25°C
Excessive operating noiseMechanical wearInspect transmission parts and replace grease if necessary
Unstable installationRe-fix the operator and ensure flat mounting surface
  1. Key Features Summary
  2. Large compatibilité de tension: 110-230V et / 110-250À DC, reducing spare parts stock and procurement costs
  3. Réponse rapide: Typical 1-second operating time, meeting emergency control requirements
  4. Structure compacte: Dimension 105×75×132mm, saving space inside switchgear cabinets
  5. Haute fiabilité: Operating temperature range from -25°C to +70°C, adaptable to harsh industrial conditions
  6. Installation facile & Entretien: Standard interface for perfect matching with 3VA2 series breakers

Typical Application Cases of Siemens 3VA9267-0HA20 (MO320 Motor Operator)

This accessory is designed for 3VA2 100/160/250A molded case circuit breakers to realize remote motorized closing and tripping. With control voltage of 110–230V AC / 110–250 V CC, it is widely applied in industrial, centre de données, building and energy sectors.

  1. Automobile Welding Workshop (Automatisation industrielle)

Configuration: 3VA2 250A + 3VA9267-0HA20 + API / Fieldbus System

Application: Remote switching and automatic fault isolation for power circuits of welding robots and welders

Avantages: Minimize manual work, improve workshop safety; cut downtime via remote power-off during faults

  1. Large-scale Data Center (Infrastructure)

Configuration: 3VA2 160A + 3VA9267-0HA20 + BMS / EMS

Application: Centralized remote control for cabinet PDUs, UPS outputs and precision air conditioners

Avantages: Remote inspection and circuit operation, rapid fault location and isolation; wide voltage design compatible with global mains power

  1. Commercial Complex & Immeubles de grande hauteur (Smart Power Distribution)

Configuration: 3VA2 100–250A + 3VA9267-0HA20 + Fire Alarm / BAS System

Application: Interlocked control for emergency lighting, fire pumps and exhaust fans; remote power cut for energy saving during off-hours

Avantages: Comply with mandatory fire power cut regulations; lower operation costs and improve energy efficiency

  1. Photovoltaic & Energy Storage Power Stations (Nouvelle énergie)

Configuration: 3VA2 250A + 3VA9267-0HA20 + Power Station Monitoring System

Application: Remote grid connection/disconnection and fault protection for AC sides of inverters and energy storage cabinets

Avantages: Adapt to wide outdoor temperature (-25°C à +70°C); realize remote operation and reduce on-site inspection work

  1. Hospital Operating Room & USI (Medical Power Supply)

Configuration: 3VA2 100A + 3VA9267-0HA20 + Medical Isolated Power System

Application: Emergency switching and protection for surgical equipment and life support systems

Avantages: Fast switching (environ. 1 deuxième), high operational reliability and compliance with medical power supply standards

  1. Traitement de l'eau & Pumping Stations (Municipal Engineering)

Configuration: 3VA2 160–250A + 3VA9267-0HA20 + Pump Station PLC

Application: Remote start/stop and overload protection for submersible pumps, blowers and chemical dosing equipment

Avantages: Suitable for humid and dusty environments; unattended remote control to reduce operation costs

Points de correspondance de base

Applicable Breakers: 3VA2 100/160/250A (3-pôle / 4-pôle)

Tension de contrôle: 110–230V AC / 110–250 V CC (Universal wide voltage)

Type de montage: Front-mounted (MO320), Dimension: 105×75×132mm

Fonctions clés: Remote closing & tripping, fault isolation; suitable for industrial, building and new energy applications