Siemens SITOP PSU8200 6EP1336-3BA10 Switch-Mode Power Supply

Numéro de commande: 6EP1336-3BA10 Full Designation: SITOP PSU8200 /1ACDC /24VDC /20A DIN-rail Industrial Switch-Mode Power Supply Output: 24 VDC 20 A, 480 W; Supports parallel operation for power expansion and redundant operation Core Electrical Specifications Input (Unique AC/DC dual-input for this model) AC rated: 120-230 ACC, operating range 85-275 VAC, 50-60 Hz DC rated: 110-220 V DC, operating range 88-350 VDC Input current: 2.5 A @230 VAC; 4.6 UN ...

  • Détails du produit

Numéro de commande: 6EP1336-3BA10

Désignation complète: SITOP PSU8200 /1ACDC /24VDC /20A DIN-rail Industrial Switch-Mode Power Supply

Sortir: 24 VDC 20 A, 480 W; Supports parallel operation for power expansion and redundant operation

  1. Spécifications électriques de base

Saisir (Unique AC/DC dual-input for this model)

AC rated: 120-230 ACC, operating range 85-275 VAC, 50-60 Hz

DC rated: 110-220 V DC, operating range 88-350 VDC

Courant d'entrée: 2.5 A @230 VAC; 4.6 A @120 VAC

Hold-up time: ≥20 ms at rated load

⚠️ Power derating is required when input voltage<100 V

Sortir

Nominal: 24 VCC / 20 UN

Plage réglable: 24.0-28.8 VCC (potentiometer on front panel for long-cable voltage drop compensation)

Power-Boost function: Up to 3× nominal current (60 UN) for inrush loads such as motor and relay startup; selectable constant-current mode or latching shutdown upon short-circuit

Galvanically isolated output; protection against short-circuit, surcharge, overvoltage and overtemperature; auto-recovery after over-temperature shutdown

Efficacité: environ. 93%-94%

Signal Terminals

  1. 24V-OK relay contact (13-14): Potential-free dry contact, closed when power supply operates normally, for PLC status diagnosis
  2. Remote on/off (15-16): Potential-free contact for external remote activation / deactivation of 24 V output
  3. Mécanique & Données environnementales

Montage: Snap-on to standard DIN-rail, boîtier métallique, fan-less natural convection cooling

Dimensions: W90 mm × H125 mm × D125 mm

Poids: environ. 1.2 kilos

Classe de protection: IP20 (for cabinet-mount use only)

Température de fonctionnement: -25℃ ~ + 70 ℃; derating above 60℃; maximum. 75 % load at 70 ℃

Heat dissipation clearance: ≥50 mm clearance top & bas; units may be mounted tightly side-by-side

Certifications: CE, UL/cUL, CCC, GL marine approval, RoHS

III. Model Evolution & Options de remplacement

  1. Direct predecessor replacement: 6EP1336-3BA00 (abandonné)

6EP1336-3BA10 is hardware-revamped version, pin-to-pin, dimension-to-dimension, function-compatible drop-in replacement, with higher efficiency and improved low-input-voltage performance.

  1. New-project new-generation SITOP PSU6200 series: 6EP3336-8SB00-0AY0

Note: 6EP3336-8SB00-0AY0 supports AC-input only, no DC-input capability. Not hardware-compatible; terminal assignments differ, pay attention during selection.

  1. Compatible Extension Modules (PSU8200 Modular System)

Directly compatible with SITOP modular add-ons without extra adapters:

Buffer module: 6EP1961-3BA21; DC-UPS uninterruptible module

Redundancy module: 6EP1961-3BA00; for dual-power redundant supply

Selectivity module: 6EP1961-3BA31, multi-channel 24 V branch current-limiting protection; short-circuit on one branch will not collapse the whole 24 V busbar

  1. Scénarios d'application typiques

Armoires de contrôle PLC, robotique, machines-outils, port & marine equipment, process automation. Ideal for systems requiring AC/DC dual-input (par exemple. backup DC supply), charges d'appel élevées, power-status feedback and remote on/off control.

  1. Directives de câblage
  2. Bornes d'entrée: L1, N(L2), PE; supports single-phase AC, two-phase tap from three-phase mains, or DC input
  3. Sortir: Dual sets of screw terminals for +24V and 0V. Parallel both sets when output current>15 A for current sharing and thermal prevention
  4. Signal terminals: 13-14 retour d'état; 15-16 remote on/off; both are potential-free contacts, do not connect high-voltage circuits
  5. Factory default output voltage is 24 V. Fine-tune to 26-28 V for long-cable drop compensation; do not exceed withstand voltage of downstream equipment.

Mounting Instructions for Siemens 6EP1336-3BA10 (PSU8200-20A)

  1. Type de montage

Montage standard: EN 60715 compliant DIN-rail (TS35-7.5 / TS35-15, 35 mm rail) snap-in installation

Built-in spring clip on rear side, tool-free mounting. Release lever at bottom; push lever down to remove unit from rail.

❌ Wall-mounting by direct screw fastening is NOT supported. DIN-rail mounting only.

Indice de protection IP20, pour installation en armoire intérieure uniquement; not for outdoor bare-field deployment.

  1. Orientation de montage (Mandatory for thermal performance & durée de vie)

Fan-less natural convection; orientation cannot be arbitrarily changed

  1. Standard position: montage vertical, terminals facing down (saisir & output terminals at bottom of unit), unit upright. This is the only official position for continuous full-load operation.
  2. ❌ Prohibited: horizontal side-mount, upside-down (terminals up), tilted mounting. Non-standard orientations degrade cooling and require heavy load derating; not recommended for field deployment.
  3. Thermal Clearance Requirements (Critique)
DirectionRequired ClearanceRemarques
Haut≥50 mmAllow upward hot‑air flow; cable trunking shall not occupy this space
Bas≥50 mmCool‑air intake; trunking shall not block bottom area
Gauche / Droite0 mmMultiple units can be fitted tightly adjacent, no side‑to‑side gap required

Do not mount heat-generating components directly above the power supply. Derate load when cabinet ambient>60 ℃.

  1. Montage & Removal Procedure
  2. Hook upper latch of rear spring clip onto DIN-rail.
  3. Press lower section toward rail until an audible “click” confirms clip engagement.
  4. Shake gently to verify firm seating against vibration loosening.
  5. Suppression: Push down the black release lever at bottom, swing lower part outward, lift unit off rail.

For high-vibration environments: Fit DIN-rail end stops to prevent sliding displacement.

  1. Câblage des bornes & Torque Values

Perform wiring with power disconnected.

Input L/N/PE: 0.2-4 mm² conductors, tightening torque 0.5-0.6 N·m

Output +24V /0V: Dual terminal pairs; parallel both pairs for currents>15 A for heat mitigation

Signal terminals 13-14 (OK feedback), 15-16 (Remote on/off): 0.14-1.5 mm² fine wires, torque 0.5-0.6 N·m

  1. Mounting for Parallel / Redundancy Modules

This power supply can be installed side-by-side tightly on DIN-rail with compatible SITOP extension modules (redondance, buffer, selectivity modules). No side-to-side thermal gap needed between power supply and add-on modules.

  1. Mounting Prohibitions
  2. Do not install unit inside enclosed bottom trunking in cabinet; blocked top/bottom clearance leads to over-temperature shutdown.
  3. Forbid upside-down or horizontal installation.
  4. Do not place heat-intensive devices directly above the unit.
  5. Indoor cabinet-use only; avoid open-air and high-humidity unprotected environments.

6EP1336-3BA10 (PSU8200-20A) Parallèle / Redundancy Guidelines + Liste de contrôle de dépannage

  1. Parallel Operation for Power Expansion (No Fault Isolation)

Max.. 5 identical units in parallel for automatic current sharing. Dip-switch A must be set ON to activate parallel characteristic curve.

  1. Hardware prerequisites: Identical order number 6EP1336-3BA10; keep hardware revisions consistent if possible.
  2. Exigences de câblage

Connect +24 V and 0 V of each unit to common output busbar. Positive cables shall have identical length and cross-section to equalize impedance for proper current sharing.

All 0 V negative terminals must be commonly grounded; floating ground is not permitted.

Common input circuit-breaker recommended for synchronized start-stop.

No-load output voltage difference between individual units ≤50 mV (factory default meets requirement; recalibrate if potentiometers have been adjusted).

  1. Dip-switch settings

A-ON: Parallel mode (for power expansion)

A-OFF: Single-unit mode (défaut d'usine; do NOT leave OFF for parallel operation)

  1. Limitation: Direct parallel for power expansion cannot isolate faults. Short-circuit on one output will pull down the whole 24 V busbar. Not for fault-tolerant redundancy.
  2. 1+1 Redundant Supply (Fault-isolated, Recommended Engineering Solution)

Two PSU8200-20A units plus Redundancy Module 6EP1961-3BA00 (PSE202U) for decoupling isolation. If one power supply fails, the second takes over the load seamlessly without 24 V bus interruption.

  1. DIN-rail layout: Two power supplies + redundancy module mounted tightly adjacent; terminals all face down; no side-to-side clearance required.
  2. Points clés du câblage
  3. Feed two power supplies from independent input circuits for maximum redundancy reliability.
  4. Connect 24 V+ output of each power supply to the two input channels of the redundancy module.
  5. Reliably bond 0 V terminals of both power supplies and redundancy module for equipotential connection; this step is mandatory.
  6. Route redundancy-module output to field 24 V load busbar.
  7. The redundancy module provides fault relay contacts, connect to PLC digital input for redundancy-fault alarm.
  8. Dip-switch setting: For redundant configuration, set dip-switch A of power supplies to OFF (single-unit mode). Do NOT activate parallel mode.

⚠️ Never implement redundancy by direct parallel without redundancy module. Internal short-circuit of one unit will crash the whole 24 V system.

III. LED Indicator Reference Table

État du voyantSignificationAction
Vert fixe alluméUnit healthy, output>20 VFonctionnement normal
Yellow steady ONSurcharge / constant‑current limit active, Power‑Boost triggeredVérifier le courant de charge; locate partial short‑circuit; réduire la charge
Red steady ONLatching shutdown (court-circuit / surtension / surchauffe)Power‑off for ≥60 seconds, or de‑assert Remote 15‑16 for ≥5 s for reset; eliminate short‑circuit / over‑heat root cause
All LEDs OFFNo input supply; internal fuse blownVerify AC/DC input voltage and PE grounding

Dip-switch B: Short-circuit response selection

B-OFF (défaut d'usine): Constant-current mode, 23 A short-circuit limiting; auto-recovery after fault clears; yellow LED lit

B-ON: Latching shutdown mode; output cuts off upon short-circuit; red LED lit; power-cycle reset required

  1. Liste de contrôle de dépannage
  2. No LED indication after power-on, zero output
  3. Measure input L-N voltage: AC 85-275 VAC / DC 88-350 VDC; confirm PE protective earth connection.
  4. Check screw terminal torque for loose contacts; verify upstream circuit-breaker status.
  5. If input voltage is normal but no LED lights: Internal input fuse failure; panne matérielle, replace power supply.
  6. Yellow LED steady ON, output drops to 18-20 V
  7. Load current exceeds 20 A → constant-current limiting mode; measure actual total load current.
  8. Partial short-circuit or cable insulation damage on output side. Disconnect all loads; check if voltage recovers to 24 V under no-load condition.
  9. Excessive voltage drop caused by long-distance thin-gauge cables; use larger-size output conductors or slightly raise output voltage via potentiometer for compensation.
  10. Red-LED latching shutdown on power-on, pas de sortie
  11. Output-side short-circuit. Test with all loads disconnected; normal no-load behavior indicates external load short-circuit.
  12. Excessive cabinet ambient temperature, insufficient top/bottom ventilation clearance triggering over-temp protection; confirm ≥50 mm top & bottom clearance.
  13. Output overvoltage: Ensure potentiometer is not accidentally adjusted above 28.8 V; confirm downstream-device voltage withstand rating.
  14. Reset procedure: Power-off ≥60 s then re-energize; or open Remote 15-16 for ≥5 s then close again.
  15. Abnormal 24V-OK (13-14) relay contact behavior

Terminaux 13-14 are potential-free dry contacts, closed only when output>20 V. Évaluation des contacts: DC30 V, maximum. 0.1 UN. For PLC digital-input signal only; do NOT drive contactor coils or high-power loads.

  1. Poor current-sharing in parallel; one unit runs excessively hot
  2. Dip-switch A not set to ON.
  3. Large discrepancy in length / cross-section of positive output cables.
  4. No-load output voltage difference>50 mV between units; fine-tune potentiometers for matching.
  5. Loose 0 V wiring leading to equipotential mismatch.
  6. Remote terminals 15-16 fail on / off control

15-16 are potential-free contacts: Short-circuit = output enable; open-circuit = output disable. No external supply required.

If remote function is unused: Keep 15-16 short-circuited with factory jumper; do not remove jumper.

  1. Recommandations de mise en service
  2. New cabinet commissioning: Power-on without load first; confirm 24 V output and steady green OK LED; connect loads incrementally.
  3. Redundancy-system commissioning: Disconnect one input source at a time; verify seamless switch-over with zero load dropout.
  4. High-temperature cabinet applications: Apply load derating above 60 ℃ ambient; avoid continuous full-20-A operation.