Code de commande: IIT205 (IIB3014BBPKG/V4A/US-104)
Hygienic M30 flush-mount inductive sensor, specially designed for food, beverage and pharmaceutical applications with cleaning cycles
✅ Spécifications clés
Données électriques
Tension d'alimentation: 10…30 V DC
Sortir: PNP normally open (NON), 3-fil
Rated sensing distance Sn: 14 mm, flush mountable
Effective sensing range: 0~11.34 mm; tolerance ±10%
Fréquence de commutation: 100 Hz
Continuous output current: 100 mA
Voltage drop: ≤2,5 V
Courant à vide: 10 mA@24VDC
Protection: protection contre l'inversion de polarité, pulsed short-circuit protection, protection contre les surcharges
Hystérèse: 1~20% Sr; switching point shift: -10~+10% Sr
Metal Reduction Factors (Important)
Acier=1; Acier inoxydable=0,7; Brass=0.5; Aluminium=0.4; Copper=0.3
Mécanique & Données environnementales
Logement: M30×1.5, overall length L=50 mm
Montage: Flush mount
Classe de protection: IP68 / IP69K (high-pressure washdown capable)
Température ambiante: 0 … +100 ℃
Poids: 103.9 g
Matériau du boîtier: V4A stainless steel, gold-plated contacts, resistant to repeated exposure to cleaning agents
Indicateur: Multi-directional yellow LED for switching status
Certifications: CE, cULus, CAE, suitable for food industry
📌 Model Code Explanation
IIT205 = IIB3014BBPKG/V4A/US-104
II: Inductive sensor
B: Cylindrical threaded housing
30: M30 thread
14: Rated sensing distance 14 mm
B: Flush mount
B: PNP normally open
PKG: Connecteur M12 à 4 broches
V4A: Boîtier en acier inoxydable
US-104: Hygienic high-temperature version
🛠️ Application Fields
Machines alimentaires, lignes de remplissage, équipement pharmaceutique, washdown stations, metal target detection under frequent CIP/SIP high-pressure cleaning and high-humidity high-temperature conditions; suitable for level detection, metal workpiece presence check and cylinder position feedback.
⚠️ Sélection & Directives d'installation
- Montage encastré: The sensor face can be recessed into metal brackets; the surrounding metal of the mounting surface will not reduce the sensing distance.
- Boîtier en acier inoxydable + Indice IP69K, resistant to alkaline cleaners and hot high-pressure washdown; NOT suitable for long-term immersion in concentrated strong acids.
- Reduction factor <1 for non-ferrous metals; sensing distance is significantly reduced for aluminium/copper targets, allow sufficient margin during selection.
- Switching frequency only 100 Hz, not applicable for high-speed counting.
- M12 4-pin male plug wiring: Brun(+24V), Bleu(0V), Noir(Sortie de signal PNP), Blanc (unused).
🧩 Replacement References
Même série: IIT202 (8 mm distance de détection, M30 hygienic type)
Alternatives nationales: M30 flush stainless steel PNP NO inductive proximity sensor; verify 14 mm sensing distance and 0~100 ℃ temperature range.
📋 Troubleshooting Checklist
- Aucun signal: Check if 24V power is supplied to brown and blue wires. Reverse polarity will not damage the sensor but causes no operation.
- No output when target approaches: Check target material (distance reduction for Al/Cu); verify flush fit with mounting metal.
- Faux déclenchement: Metal debris on sensing face; poor shield grounding of cable.
- Intermittent failure after hot washdown: Inspect plug sealing and ensure connector watertightness.
IFM IIT205 (IIB3014BBPKG/V4A/US-104) Cas de candidature
> Critères de sélection de base: Hygienic M30 flush, IP68/IP69K, 316L(V4A) acier inoxydable, 0~100 ℃, compatible with CIP/SIP high-pressure cleaning, PNP NON, 14 mm flush sensing distance; 100 Hz switching frequency, for static/low-speed position detection only, not for high-speed counting.
Cas 1: Beverage Filling Line – Spool Position Feedback for Filling Valves (Beer / Mineral Water / Dairy)
État de fonctionnement: Filling valves undergo CIP hot water + alkaline detergent high-pressure spray, wide temperature cycling from 0~95 ℃, humid mist environment.
Fonction: Mounted on hygienic pneumatic valve bodies to detect metal spool rod position. PLC confirms valve fully open / fully closed to prevent empty filling or overflow.
Why IIT205
- IP69K withstands 80~100 bar high-pressure spray and Ecolab food-grade cleaners; 316L stainless steel housing without hygienic dead zones, flush installation prevents product residue buildup.
- 0~100 ℃ withstands thermal shock; no signal drift during CIP hot cleaning.
- 14 mm sensing distance accommodates spool stroke tolerance; flush mounting ensures valve body metal does not reduce detection range.
Remarques: For stainless steel spools, reduction factor =0.7, reserve sufficient effective sensing distance; only for position confirmation, not high-speed pulse counting.
Cas 2: Metal Baffle / Metal Float Level Detection on Aseptic Tanks for Dairy Products
État de fonctionnement: Aseptic tanks for fresh milk/yogurt, periodic SIP steam sterilization, humid brackets on tank exterior, acid/alkaline cleaning cycles.
Fonction: Detect metal float to trigger high/low level alarms, start/stop feeding to prevent overflow or dry-run of tank.
Points clés: Sensor flush-recessed into stainless steel bracket, no hygienic dead corners; PEEK sensing face resistant to hot steam; M12 plug for quick disassembly during equipment cleaning.
Cas 3: Metal Tray Presence Detection for Food Packaging Machines (Meat / Ready Meal Packaging Lines)
État de fonctionnement: Conveying stainless steel trays continuously; hot water washdown between stations, high humidity and splashing food debris.
Fonction: Verify stainless steel tray arrival; trigger sealing/vacuum forming upon detection; lock mold closing if no tray present to protect tooling.
Selection Benefits: Flush installation prevents damage from tray scraping; stainless steel housing resists food cleaning fluid corrosion; multi-directional yellow LED for status inspection after washdown.
Cas 4: Hygienic Cylinder End-position Detection for Pharmaceutical Equipment (Tablet / Powder Production Lines)
État de fonctionnement: GMP cleanroom, actuators require periodic high-temperature disinfection and detergent rinsing; no grooves allowed to trap contaminants in clean areas.
Fonction: Installed at the end of hygienic cylinders to detect metal stop block on piston, feedback extend/retract end-position signal for interlocking of subsequent processes.
Points clés: Gold-plated contacts for stable operation in humid clean environments; nourriture & pharmaceutical hygienic compliance; M12 4-pin plug for fast spare part replacement.
Cas 5: Metal Workpiece / Fixture Presence Confirmation for Meat Processing Cutting Lines
État de fonctionnement: Humidité élevée, heavy foam and alkaline degreaser high-pressure washdown, wide ambient temperature fluctuation.
Fonction: Detect presence of stainless steel work fixture; lock cutting blade if fixture not in position to avoid collision and implement safety interlock.
Limites: For aluminium fixtures, sensing distance reduced to 0.4 fois; sufficient margin must be reserved during selection; not suitable for high-speed reciprocating motion.
Cas 6: Metal Baking Tray Detection at Bakery Line Discharge
État de fonctionnement: Oven outlet, high ambient temperature up to nearly 100 ℃, oil-contaminated trays, high-pressure hot water cleaning per shift.
Fonction: Detect stainless steel baking trays arriving at unloading station to start/stop conveyor belt.
Avantages: Wide temperature range 0~100 ℃, oven residual heat will not damage sensor; IP69K allows direct washdown of grease; stainless steel housing resistant to oil corrosion.
❌ Non-suitable Applications (Pitfall Reminder)
- Comptage à grande vitesse, high-speed dynamic metal target detection: seulement 100 Hz switching frequency, pulse loss occurs at high speed.
- Long-term immersion in concentrated strong acids: only resistant to weak acid/alkaline rinsing, not continuous concentrated acid soaking.
- Thin copper foil or thin aluminium sheet: heavy reduction of sensing distance, prone to misjudgement.
- Installed near high-power inverters with strong magnetic/electromagnetic interference; shielded grounding required separately.
General Installation & Directives de mise en service (Applicable à tous les cas)
- Flush-recess into metal bracket, sensor head flush with metal surface.
- Preferred target material: acier au carbone, followed by 304/316 acier inoxydable; calculate effective sensing distance in advance for aluminium/copper targets.
- Use matching hygienic watertight M12 connectors; connector area is the highest failure point during washdown.
- Perform CIP cleaning test after installation, check LED status to confirm no intermittent false triggering.
IFM IIT Series (M30 Hygienic Inductive Proximity Sensors) Liste des modèles
> Series common features: M30×1.5 thread, V4A/316L stainless steel housing, IP68/IP69K, CIP/SIP washdown resistant, 0~100 ℃, M12 4-pin plug, nourriture & pharmaceutical hygienic grade; IIT205 is the flagship model of this series
| Code de commande | Numéro de pièce complet | Distance de détection | Montage | Sortir | Longueur | Principales fonctionnalités |
| IIT202 | IIB3008BBPKG/V4A/US-104 | 8 mm | Flush | PNP NON | 50 mm | Short body, 8 plage mm, basic hygienic model |
| IIT205 | IIB3014BBPKG/V4A/US-104 | 14 mm | Flush | PNP NON | 50 mm | Your target model, most widely used for filling valve position feedback |
| IIT206 | IIB3014BBPKG/V4A/US-105 | 14 mm | Flush | PNP NON | 50 mm | Same as IIT205, firmware revision difference, specified in certain projects |
| IIT212 | IIB3015BBPKG/V4A/US-104 | 15 mm | Flush | PNP NON | 70 mm | Extended housing, 15 mm flush sensing distance |
| IIT228 | IIK3010BBPKG/AM/US-104 | 10 mm | Flush | PNP NON | 65 mm | Full metal sensing face, improved chemical resistance, extended body |
| IIT244 | IIK3012BFRKG/AM/IO/US-104 | 12 mm | Flush | PNP/NPN commutable, NO/NC configurable, IO-Link | 65 mm | IO-Link enabled, programmable parameters, transmits distance value |
| IIT245 | IIK3018BBPKG/AM/US-104 | 18 mm | Flush | PNP NON | 50 mm | Short body, 18 mm flush, long sensing distance |
| IIT246 | IIK3025BBPKG/AM/P/US-104 | 25 mm | Non affleurant | PNP NON | 65 mm | Extra long 25 plage mm, cannot be embedded into metal |
Related IT Family (M8/M12/M18 hygienic sensors, same technology platform for reference selection)
IET Series: M8 hygienic (IET201)
IFT Series: M12 hygienic (IFT201, IFT259, IFT260)
IGT Series: M18 hygienic (IGT201, IGT204, IGT261, IGT262)
Series Selection Differentiation
- IIT202 / IIT205 / IIT206: IIB prefix, PEEK sensing face, PEEK front face, rentable, highest volume in food industry; switching frequency 100Hz, only for static/low-speed position feedback, pas de IO-Link.
- IIT228 / IIT244 / IIT245 / IIT246: IIK prefix, solid 316L metal sensing face, no PEEK plastic, superior chemical cleaning resistance; IIT244 supports IO-Link communication, real-time distance reading and remote NO/NC switching via PLC.
- Flush mount: Sensor head can be recessed in metal bracket, surrounding metal will not reduce sensing distance. Non-flush mount: Keep clearance, cannot be embedded in metal.
Guide de sélection rapide
Standard M30 hygienic position detection, 14 mm requirement: IIT205
Short range 8 mm: IIT202
IO-Link communication and remote parameter setting required: IIT244
Longer flush sensing distance 18 mm: IIT245
25 mm long range, non-flush installation acceptable: IIT246
Notes complémentaires
Tous les modèles: 10~30VDC supply; M12 4-pin male plug; gold-plated contacts for high stability in humid washdown environments
Metal reduction factors: Acier=1, 316 stainless steel=0.7, Aluminium=0.4, Copper=0.3; calculate reduced range for Al/Cu targets during selection
Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur





















NH42-63-318x560.png)