Wieland SNA-4053-K-A Relais de sécurité

SNA: Safety switch monitoring series (for monitoring emergency stop, safety gates, safety light curtains) 4053: Specification code K: Pluggable screw terminals A: Supply voltage AC/DC 24 V Suffix differentiation for the series: A = AC/DC 24 V; C = Push-in spring terminals; KM = Automatic reset; KE = Special version Core Specifications & Safety Ratings ...

  • Détails du produit

SNA: Safety switch monitoring series (for monitoring emergency stop, safety gates, safety light curtains)

4053: Code de spécification

K: Pluggable screw terminals

UN: Supply voltage AC/DC 24 V

Suffix differentiation for the series:

A = AC/DC 24 V; C = Push-in spring terminals; KM = Automatic reset; KE = Special version

  1. Spécifications de base & Safety Ratings
  2. Certifications de sécurité

PL e / Catégorie 4 (EN ISO 13849-1)

SIL CL3 (DANS 62061)

  1. Configuration des contacts

3 safety normally open contacts (13-14 / 23-24 / 33-34)

1 normally closed signal contact (41-42)

  1. Données électriques

Fournir: 24 V CA/CC

Continuous rated current Ith: 8 UN

AC-15: 230 V / 5 UN; DC-13: 24 V / 5 UN

Montage: DEPUIS 35 rail mm; Largeur 22.5 mm

  1. Input Functions

Dual-channel safety circuit (S11/S12, S21/S22)

Supports cross-channel short-circuit monitoring

Réinitialisation manuelle (with reset monitoring)

Convient pour: Emergency stop buttons, safety gate switches, magnetic safety switches, safety light curtains

  1. Typical Wiring Logic
  2. A1(+), A2(-): 24 Alimentation V
  3. S11-S12, S21-S22: Dual-channel safety devices (normally closed signal)
  4. S33-S34: Reset terminals (connect external normally open reset button; shorted = automatic reset)
  5. 13-14 / 23-24 / 33-34: Safety outputs (for controlling main contactors)
  6. 41-42: Normally closed fault feedback signal
  7. Model Correction & Référence alternative

⚠️ The most frequently confused model on the market: SNA4043K-A (4043, easily mistaken for 4053)

⚠️ Important Verification Conclusion

SNA4053K-A is NOT an official standard model in Wieland catalogues, it is highly likely a transcription error:

  1. Most common miswriting: SNA4043K-A (Numéro de pièce. R1.188.1810.0)

Réinitialisation automatique, no reset monitoring; dual-channel with short-circuit monitoring

  1. Alternative similar model: SNA4063K-A

Réinitialisation manuelle (with reset monitoring) — this is the core difference from SNA4043

Model rules:

SNA4043K-A: Réinitialisation automatique

SNA4063K-A: Réinitialisation manuelle (reset button monitoring)

Both models share identical contact configuration, safety rating and dimensions; only reset logic differs.

Quick Selection Comparison Table

ModèleNuméro de pièce du fabricant.Tension d'alimentationMode de réinitialisationType de borne
SNA4043K‑AR1.188.1810.0CA/CC 24 VRéinitialisation automatiquePluggable screw K
SNA4063K‑AR1.188.1870.0CA/CC 24 VRéinitialisation manuelle (with reset monitoring)Pluggable screw K

Recommended Actions

  1. Verify the printed model on the physical nameplate of the unit;
  2. Confirm site requirements: Reset monitoring required or not

Emergency stop circuits generally require manual reset (SNA4063K-A)

Safety light curtain applications may adopt automatic reset (SNA4043K-A)

Application Scenarios of Wieland SNA Series Relais de sécurité (SNA4043 / SNA4063)

This series achieves PL e / Cat.4 / SIL3 with dual-channel monitoring, primarily deployed for safety circuits on machine tools and automated production lines. Content is divided into supported safety signal types, industry applications, and key selection differentiation.

  1. Supported Safety Input Signals (Hardware Utilization)
  2. Emergency stop buttons (dual normally closed contacts)

Most common application: Machine main emergency stop and zone emergency stop circuits.

Standard requirement: Emergency stop circuits prefer SNA4063K-A (manual reset with monitoring).

  1. Safety gate switches / Magnetic safety sensors

Interlock for protective doors, maintenance doors and perimeter fencing; power circuit cutout upon door opening.

  1. Safety light curtains

Hazard zone intrusion protection for presses, conveyor lines and robot stations.

Light curtain solutions commonly use SNA4043K-A (réinitialisation automatique).

  1. Two-hand control devices

For stamping and riveting equipment, preventing single-hand access to hazardous zones.

  1. Safety mats, safety bumpers

Perimeter intrusion detection around robot cells, automatic doors and lifting platforms.

  1. Major Industry & Equipment Applications

(1) Industrie des machines-outils

Tours CNC, machining centres, broyeurs, poinçonneuses, machines à cintrer

Application: Protective door interlock, circuits d'arrêt d'urgence, safety light curtain protection

(2) Automated Production & Packaging Equipment

Machines d'emballage, palletizers, conveyor lines, matériel de tri, labellers

Robot workstations, gantry robot safety fence interlock

(3) Caoutchouc & Industrie du plastique

Injection moulding machines, extrudeuses, blow moulding equipment: Safety gates, arrêt d'urgence, safety light curtains

(4) Logistique & Warehousing Equipment

Automated warehouses, lifts, shuttles, lignes de tri

Lifting platforms, dock leveller safety interlocks

(5) Nouvelle énergie & Lithium Battery Equipment

Cell assembly machines, electrolyte filling machines, sealing equipment, test tooling

Wieland products are widely adopted on export machinery to meet EU CE Machinery Directive requirements

(6) Travail du bois & Machines d'impression

Panel saws, machines à découper, presses à imprimer, die-cutting machine safety protection

(7) General Custom Automation

Custom test fixtures and assembly machines; deployed as core safety logic unit to cut off main contactors and servo power circuits.

  1. Critical Application Selection Comparison
ModèleMode de réinitialisationApplication typique
SNA4043K‑ARéinitialisation automatiqueSafety light curtains, safety bumpers; system enables restart automatically after obstacle removal
SNA4063K‑ARéinitialisation manuelle (with reset monitoring)Emergency stop buttons, safety gate switches. Manual reset operation is mandatory before machine restart (required by machinery safety standards)

⚠️ SNA-4053-K-A is not an official Wieland standard model. It is almost certainly a nameplate transcription error; physical unit will be one of the two above variants.

  1. Limites & Applications inappropriées
  2. Cannot directly drive high-power loads; safety contacts are intended to control contactor coils, not motors directly
  3. Not suitable for solenoid valves or high-frequency switching loads
  4. Cannot satisfy safety requirements higher than PL e / Cat.4 (this series already reaches Cat.4 maximum rating)

Selection Guidelines for Wieland SNA / SNO Safety Relays

Based on the SNA4043 / SNA4063 platform covered above; structured criteria ready for engineering proposals and procurement checks.

Étape 1: Confirm Required Safety Rating (Mandatory Priority)

Compliant with ISO 13849-1 / DANS 62061

  1. PL & Catégorie

PL e / Cat.4: Highest rating. For high-risk stations including robots, stamping, injection moulding, machine tools and lithium battery equipment (supported by all mainstream SNA variants)

PLd / Cat.3: Low-risk general automation and conveyor lines

  1. Niveau SIL

SIL 3 corresponds to PL e; preferred for machinery exported to EU

✅ Selection Rule: Do NOT downgrade safety rating for high-risk equipment.

Étape 2: Determine Safety Input Channel Configuration (Dual Channel Is Standard)

Channel Modes

Dual-channel monitoring with cross short-circuit detection: Industry standard, fitted across all SNA variants. Compatible with dual normally closed safety devices (Arrêt d'urgence, safety gates, light curtains)

Single channel: Only permitted for low-risk scenarios; available on selected SNO variants. NOT allowed for high-risk machinery.

Compatible Sensor Types

Emergency stop switches, mechanical safety gates: Dual normally closed (Caroline du Nord)

Magnetic safety switches, safety light curtains: Double NC / OSSD signals

⚠️ Two types of safety light curtains:

① OSSD solid-state output → Requires relay model supporting OSSD input

② Light curtain with relay converted contact output → Compatible with standard SNA4043 / SNA4063

Étape 3: Mode de réinitialisation (Most Common Source of Wrong Selection!)

Reset TypeExemple de modèleApplicationCompliance Note
Réinitialisation automatiqueSNA4043K‑ASafety light curtains, safety bumpers, safety mats; system ready after obstacle clearedFORBIDDEN for emergency stop and safety gate circuits
Réinitialisation manuelle (with reset line monitoring)SNA4063K‑AEmergency stop buttons, machine protective safety gates; manual reset push required before restartMandatory recommendation per machinery safety standards; preferred for most complete machinery

Distinction clé:

Monitored reset detects open or short circuits on reset wiring and triggers safety lockout for superior safety. Simple unmonitored manual reset should be avoided on new projects.

Étape 4: Tension d'alimentation

Main Wieland options:

Suffix A = AC/DC 24 V (Automation standard, selected in 90% of projects)

Less common: 110 ACC, 230 VAC — only for legacy retrofits

Exemple: SNA4063K-A → A = AC/DC 24 V alimentation

Étape 5: Type de borne (Identified by Suffix K / C)

K = Pluggable screw terminals

Avantages: Vibration resistant, ideal for permanent cabinet installation and on-site maintenance (the unit in your photo uses K terminals)

C = Push-in spring terminals

Avantages: Fast wiring without screwdrivers; use cautiously under heavy vibration

Exemple: SNA4063K-A

Étape 6: Output Contact Configuration

Main Safety Outputs (For Power Circuit Cutoff)

SNA4043 / SNA4063: 3 normally open safety contacts

But: Wired in series with main contactor coils for redundant shutdown

Auxiliary Signal Contacts (PLC Feedback)

1 built-in normally closed fault contact

Opens upon safety activation or relay fault; used for alarm indicators and PLC signalling

Remarque sur la sélection: If multiple feedback signals are required, add auxiliary relays. Safety contacts should not be expanded externally.

Contact Load Ratings

AC-15: 230 V / 5 UN

DC-13: 24 V / 5 UN

👉 Never drive motors directly; only control contactor coils!

Étape 7: Montage & Spécifications physiques

  1. Montage: Standard DIN 35 rail mm
  2. Largeur: SNA40xx series 22.5 mm, compact design saving cabinet space
  3. Évaluation environnementale: IP20 (pour installation en armoire uniquement; not for outdoor direct deployment)

Étape 8: Differentiate SNA vs SNO Series (Frequent Confusion)

SNA Series: Dual-channel safety monitoring, up to PL e Cat.4; for emergency stop, safety gates, light curtains (your target series)

SNO Series: Predominantly single channel, lower safety rating generally PL d and below; low-cost basic solutions

Common Selection Pitfalls Checklist

  1. ❌ Misapplication: Using automatic reset SNA4043 for emergency stop circuits — violates machinery safety standards, fails third-party audit & Certification CE
  2. ❌ Transcription error SNA-4053-K-A: No official model; physical unit is either SNA4043 or SNA4063
  3. ❌ Direct drive of solenoid valves or high-power loads with safety contacts → contact burnout and loss of safety function
  4. ❌ Mixing K screw terminals and C spring terminals, leading to mismatch on delivery
  5. ❌ Ignoring reset monitoring requirements → machine fails acceptance testing

Rapid Selection Workflow (For Field Engineers)

  1. Identify safety device: Emergency stop / safety gate → select SNA4063xx-A (monitored manual reset); Light curtain / safety bumper → SNA4043xx-A (réinitialisation automatique)
  2. Confirm supply voltage: Default AC/DC24V suffix A
  3. Select terminal type: Permanent cabinet installation → K screw terminal; high volume assembly for fast wiring → C spring terminal
  4. Verify safety rating: High-risk equipment requires PL e / Cat.4 / SIL3
  5. Confirm number of safety contacts sufficient for contactor control

Complete Official Model List of Wieland SNA40xx Safety Relays

Series Profile: safeRELAY SNA40xx dual-channel safety monitoring, PL e / Cat.4 / SIL3, Montage sur rail DIN;

⚠️ Important Notice: SNA-4053-K-A is NOT an official Wieland model, it is a transcription error. Official core variants are limited to 4043 / 4044 / 4063 / 4064;

Industry standard: Suffix A = AC/DC24 V (automation default). Specify A suffix for new orders.

  1. Règles de dénomination des modèles

`SNA 40XX [Terminal][Réinitialiser]-[Voltage Suffix]`

  1. SNA: Dual-channel safety monitoring base unit
  2. 40XX:

4043: 3 safety NO contacts, réinitialisation automatique (no reset monitoring)

4044: 4 safety NO contacts, réinitialisation automatique (no reset monitoring)

4063: 3 safety NO contacts, manual reset (with reset circuit monitoring)

4064: 4 safety NO contacts, manual reset (with reset circuit monitoring)

Last digit 3 = 3 safety NO contacts; Last digit 4 = 4 safety NO contacts

  1. Terminal Code

K: Pluggable screw terminals (most widely used in projects)

C: Pluggable Push-in spring terminals

  1. Extended Reset Suffix (KM/KE)

KM: Simple manual reset without monitoring; rarely specified for new projects

  1. Voltage Suffix

UN: CA/CC 24 V (automation standard)

Pas de suffixe: Fixed screw terminals (legacy models, progressivement éliminé)

  1. Mainstream Models for Domestic Projects (24 V CA/CC)

SNA4043 Series | Réinitialisation automatique, 3 Safety NO Contacts

Modèle completWieland Part No.Type de borneConfiguration des contactsMode de réinitialisationApplication typique
SNA4043K‑AR1.188.1810.0Pluggable screw K3 Safety NO + 1 NC Fault ContactRéinitialisation automatique (no reset monitoring)Safety light curtains, safety bumpers, safety mats
SNA4043C‑AR1.188.1940.0Push‑in spring C3 Safety NO + 1 NC Fault ContactRéinitialisation automatique (no reset monitoring)High volume cabinet fast wiring

SNA4044 Series | Réinitialisation automatique, 4 Safety NO Contacts

Modèle completWieland Part No.Type de borneConfiguration des contactsMode de réinitialisationApplication typique
SNA4044K‑AR1.188.1860.0Pluggable screw K4 Safety NO + 1 NC Fault ContactRéinitialisation automatique (no reset monitoring)Applications requiring multiple safety cutout circuits, light curtain systems
SNA4044C‑AR1.188.1960.0Push‑in spring C4 Safety NO + 1 NC Fault ContactRéinitialisation automatique (no reset monitoring)Synchronous cutout of multiple contactors

SNA4063 Series | Réinitialisation manuelle (Monitored), 3 Safety NO Contacts【Preferred for Complete Machinery】

Modèle completWieland Part No.Type de borneConfiguration des contactsMode de réinitialisationApplication typique
SNA4063K‑AR1.188.1440.0Pluggable screw K3 Safety NO + 1 NC Fault ContactManual reset ✅ with reset monitoringEmergency stop buttons, machine safety gates, CE certified machinery (Les plus populaires)
SNA4063C‑AR1.188.1950.0Push‑in spring C3 Safety NO + 1 NC Fault ContactManual reset ✅ with reset monitoringExport custom automation, fast cabinet wiring

SNA4064 Series | Réinitialisation manuelle (Monitored), 4 Safety NO Contacts

Modèle completWieland Part No.Type de borneConfiguration des contactsMode de réinitialisationApplication typique
SNA4064K‑AR1.188.1880.0Pluggable screw K4 Safety NO + 1 NC Fault ContactManual reset ✅ with reset monitoringMulti‑group power circuit cutout, large machine tools
SNA4064C‑AR1.188.1970.0Push‑in spring C4 Safety NO + 1 NC Fault ContactManual reset ✅ with reset monitoringSystems requiring synchronous shutdown of multiple contactors
  1. Legacy Non-Standard Voltage Models (Only For Equipment Replacement, Not Recommended For New Projects)

Fixed non-pluggable screw terminals (no suffix A)

SNA4043K: AC42~48 V / AC115 V / AC230 V

SNA4063K: AC230 V

Note: All new domestic machinery shall adopt AC/DC24 V models with suffix -A

  1. General Specifications Applicable to All Variants
  2. Cote de sécurité: PL e / Cat.4, SIL 3 (EN ISO13849-1, EN62061)
  3. Contacter les évaluations: AC-15 230 V/5 A; DC-13 24 V/5 A
  4. Montage: DEPUIS 35 rail mm; Largeur 22.5 mm; IP20 (Cabinet installation only)
  5. Caractéristiques: Dual-channel cross short-circuit monitoring, EDM external device monitoring support, 3 status LED indicators
  6. Câblage: Supports single-channel / dual-channel connection modes
  7. Quick Selection Summary Table
Model GroupMode de réinitialisationCompatible Safety DevicesCompliance Restriction
SNA4043 / SNA4044Réinitialisation automatiqueSafety light curtains, safety bumpers❌ NOT permitted for emergency stop and machine safety gate circuits
SNA4063 / SNA4064Réinitialisation manuelle (Monitored)Emergency stop switches, safety gate switches✅ Compliant with EN60204 machinery safety standards, accepted for CE audits
  1. Procurement Reminders
  2. If customer submits model `SNA-4053-K-A` → Confirm transcription error immediately. Check physical nameplate; the actual unit is almost certainly SNA4063K-A.
  3. Always include complete model + manufacturer part number in BOM to avoid delivery mismatch between K screw terminals and C spring terminals.
  4. Do not interchange automatic reset SNA4043 and monitored manual reset SNA4063; incorrect selection will lead to failed safety acceptance.
  5. Contact count selection: 3 contactors or less → SNA4063; ≥4 contactors requiring synchronous shutdown → select SNA4064.