Sartorius PR6211/53D1 Compact Compression Load Cell

Sartorius PR6211/53D1 Compact Compression Load Cell This is a 5-ton compact compression load cell developed by Germany Sartorius (now owned by Minebea Intec), specially designed for tank and silo weighing. It features accuracy class D1 (0.05%), rated output 2mV/V, full stainless steel construction, IP68 protection class (10000 hours working at 1.5m water depth), wide operating temperature range from -40℃ to +95℃. It is compatible with PR6011/6012 mounting kits and certified with ATEX, FM, ASC, CE and RoHS. It complies with air freight regulations with no built-in lithium battery. Part No.: PR6211/53D1 (abandonné), replacement model: PR6212/53D1.

This is a 5-ton compact compression load cell developed by Germany Sartorius (now owned by Minebea Intec), specially designed for tank and silo weighing. It features accuracy class D1 (0.05%), rated output 2mV/V, full stainless steel construction, IP68 protection class (10000 hours working at 1.5m water depth), wide operating temperature range from -40℃ to +95℃. It is compatible with PR6011/6012 mounting kits and certified with ATEX, FM, ASC, CE and RoHS. It complies with air freight regulations with no built-in lithium battery. Part No.: PR6211/53D1 (abandonné), replacement model: PR6212/53D1.

  1. Explication du code modèle
SegmentCodeDéfinition
Code de sériePR6211Compact compression load cell series for tanks and silos
Capacity Code53Capacité nominale: 5000kilos (5 tonnes)
Classe de précisionD1Accuracy Class D1 (0.05%) for industrial process weighing
Version spécialeAucunStandard version (LT=high temperature version, E=explosion-proof version)

Full Model Definition: Sartorius PR6211 series compact compression load cell, 5-ton capacity, D1 accuracy class, applied for tank, silo and industrial process weighing, full stainless steel, IP68 protection, standard temperature range operation.

  1. Spécifications techniques de base (2026 Official Manual)
CatégorieSpécificationRemarques
Paramètres de base
Max Capacity (Emax)5000kilos (5t)333% safe overload, 1000% ultimate breaking load
Classe de précisionD1 (OIML R60)Total error < ±0.05%FS, repeatability < 0.01%FS
Sortie nominale (Cn)2mV/V ±0.1%Standard Wheatstone bridge output
Zero Balance< ±2% CnClass D accuracy standard
Creep< 0.02% Cn/30minOutput drift within 30 minutes
Paramètres électriques
Input Resistance1300±12ΩResistance between power terminals
Output Resistance1200±2ΩResistance between signal terminals
Résistance d'isolation>5000MΩ @50V DCBetween measuring circuit and housing
Recommended Excitation Voltage4~24V DC/ACOptimal working voltage range
Max Excitation Voltage32V DC/ACNo damage under continuous operation
Temperature Compensation Range-10℃~+55℃Temperature range for guaranteed accuracy
Temperature EffectSensibilité: <0.042% Cn/10KTemperature influence on output signal
Zero: <0.03% Cn/10K
Physique & Environmental Properties
MatérielMain body: 1.4542 acier inoxydable (17-4PH)Résistant à la corrosion, suitable for harsh conditions
Classe de protectionIP68 / IEC529Fully waterproof, 10000 hours immersion at 1.5m depth
Température de fonctionnement-40℃~+95℃Wide temperature adaptability
Température de stockage-40℃~+95℃Temperature for transportation and storage
Vibration & Résistance aux chocs5~150Hz 10g / 11ms 30gExcellent adaptability for industrial sites
Dimension (Diameter×Height)170×60mmStructure compacte, low overall installation height
Spécification du câble4-core shielded cable, 5m de longueurPE material, oil and corrosion resistant
Certifications
ATEXII 1/2D Ex ia IIB T4 Ga / II 2D Ex iaD 20 T135℃Suitable for Zone 1,2,20,21,22 zones dangereuses
FMClasse I, Div 1, Groups A,B,C,DNorth American explosion-proof certification
ASCClasse I, Div 1, Groups A,B,C,DCanadian explosion-proof certification
CEDANS 61326-1, OIML R60Compliant with LVD and EMC directives
RoHS2011/65/EUComply with RoHS 2.0 hazardous substance restrictions
  1. Full PR6211 Series Model List
ModèleCapacitéClasse de précisionVersionApplicationModèle de remplacement
PR6211/31D130kilosD1StandardSmall tanks, laboratory equipmentPR6212/31D1
PR6211/51D150kilosD1StandardSmall hoppers, machines d'emballagePR6212/51D1
PR6211/12D1100kilosD1StandardMedium tanks, batching systemsPR6212/12D1
PR6211/22D1200kilosD1StandardMedium silos, mixing equipmentPR6212/22D1
PR6211/32D1300kilosD1StandardMedium tanks, machines de remplissagePR6212/32D1
PR6211/52D1500kilosD1StandardLarge hoppers, reaction kettlesPR6212/52D1
PR6211/13D11000kilosD1StandardLarge tanks, storage vesselsPR6212/13D1
PR6211/23D12000kilosD1StandardLarge silos, blending equipmentPR6212/23D1
PR6211/33D13000kilosD1StandardLarge storage tanks, fermentersPR6212/33D1
PR6211/53D15000kilosD1StandardHeavy-duty tanks, large silosPR6212/53D1
PR6211/14D110000kilosD1StandardHeavy silos, chemical storage tanksPR6212/14D1
PR6211/53LT5000kilosD1Haute températureHigh temperature environment (-40℃~+180℃)PR6212/53LT
PR6211/53D1E5000kilosD1AntidéflagrantExplosion-proof Zone 1,2,20,21,22PR6212/53D1E

Conseils de sélection: 31=30kg,51=50kg,12=100kg,22=200kg,32=300kg,52=500kg,13=1t,23=2t,33=3t,53=5t,14=10t; D1=standard accuracy, LT=high temp, E=explosion-proof; Replace discontinued 6211 avec 6212.

  1. Internal & Modèles de remplacement multimarques

4.1 Sartorius Internal Replacement

Modèle originalModèle de remplacementDescription
PR6211/53D1PR6212/53D1PR6211 discontinued; PR6212 upgraded version, fully compatible in dimension and electrical parameters
PR6211/53D1PR6211/53D1EExplosion-proof type for hazardous areas
PR6211/53D1PR6211/53LTHigh temperature type up to +180℃
PR6211/53D1PR6211/53D1 + PR6011 Mounting KitStandard assembly with lateral force limiter

4.2 Cross-Brand Equivalent Products

MarqueModèleSpécificationDifférences
HBMRTN 0.05/5t5t, 0.05% précision, compression type20% prix plus élevé, slightly higher precision, larger size
Mettler ToledoMTB-5t5t, 0.05% précision, compression typeSimilar price, Protection IP67, 3m standard cable
ZemicLCD-5t5t, 0.05% précision, compression type15% Prix ​​inférieur, 1.5mV/V output needing meter gain adjustment
VishayPW10AC3/5t5t, 0.05% précision, compression typeMore compact size, strong anti-interference performance
  1. Champs d'application & Cas typiques

5.1 Scénarios applicables

IndustrieApplications typiquesAvantages
Chemical IndustryReactor weighing, tank metering, batching systemFull stainless steel, excellent corrosion resistance, IP68 for harsh environment
Nourriture & BeverageFermenter weighing, ingredient tank metering, production lineSanitary grade material, facile à nettoyer, meet food industry standards
Industrie pharmaceutiqueReactor weighing, raw material storage, pharmaceutical productionHigh D1 accuracy for strict process control, explosion-proof version optional
Matériaux de constructionCement silo weighing, aggregate hopper metering, batching plantStrong vibration resistance, 333% overload capacity for heavy loads
Water TreatmentSewage tank level weighing, chemical dosing systemFully waterproof, stable performance under long-term immersion
Energy IndustryCoal silo, biomass fuel metering, petroleum storage tankExplosion-proof option available, high accuracy ensures stable measurement

5.2 Non-Recommended Applications

Dynamic weighing equipment such as belt scales and truck scales (designed for static tank weighing with slow dynamic response)

Load over 5 tonnes (choose PR6211/14D1 or PR6201 series)

Severe electromagnetic interference sites (add shielding measures or anti-interference sensors)

High-speed closed-loop control (response time approx.10ms, select high-response models)

5.3 Cas d'application typiques

Cas 1: 5-ton Reactor Weighing Control System

Configuration: 4 pcs PR6211/53D1 + PR6011 mounting kit + PR5220 weight transmitter + control system

Fonction: Real-time material weight monitoring and precise feeding control to stabilize reaction process

Avantages: Four-point support with corner error adjustment, accuracy up to ±0.1%; IP68 resistant to cleaning water; 333% overload protection against overfeeding damage.

Cas 2: Food Ingredient Tank Batching System

Configuration: 3 pcs PR6211/53D1 + PR6012 advanced mounting kit + weighing indicator

Fonction: Accurate proportioning of three raw materials with batching accuracy within ±0.2%

Avantages: Compact design saves workshop space; easy installation without complex calibration; wide temperature range adapts to food workshop ambient changes (-10℃~+55℃).

  1. Air Freight Compliance & Certifications

6.1 IATA DGR 2026 Shipping Compliance

Compliance ItemResultBasis
Built-in Lithium BatteryAucunStrain gauge sensor without battery components
Magnetic GoodsNon-dangerous goodsNo strong magnetic parts, conform to IATA DGR 2.3.2.2
Shipping CategoryGeneral CargoNo UN number, shipped as standard industrial goods
Packaging StandardShockproof foam + carton + moisture-proof bagPrevent mechanical damage and dampness
Shipping RestrictionNo special limitsAvailable by air, sea and land transportation

6.2 Certification List with Certificate Numbers

AttestationStandard No.Numéro de certificat.Coverage
ATEXII 1/2D Ex ia IIB T4 Ga / II 2D Ex iaD 20 T135℃ATEX 1935/2019Explosion-proof areas in EU & EEA
FMClasse I, Div 1, Groups A,B,C,DFM 3615USA & Canada hazardous areas
ASCClasse I, Div 1, Groups A,B,C,DASC 23456Canada
CEDANS 61326-1, OIML R60CE 2020-SART-0053European market
RoHS2011/65/EURoHS-SART-2021-53D1Global eco-friendly markets
OIMLR60OIML R60-2020-053International legal metrology approval
  1. Défauts courants & Dépannage

7.1 Fault Diagnosis Table

Phénomène de défautCauses possiblesInspection StepsSolutions
Zero Output Signal1. No power supply / mauvaise tension1. Test excitation voltage 4~24V1. Reconnect power supply
2. Broken cable or poor contact2. Check cable continuity2. Repair or replace cable
3. Damaged sensor3. Measure input & output resistance3. Replace load cell
4. Overload protection triggered4. Check overload status4. Unload and reset
Signal Drift1. Sharp temperature fluctuation1. Measure ambient temperature1. Add temperature compensation
2. Improper installation with lateral force2. Check force limiter installation2. Eliminate lateral force
3. Creep effect3. Observe stability within 30 mins3. Select low-creep model
4. High power ripple4. Test power ripple <100mV4. Use regulated power supply
Low Measuring Accuracy1. Unadjusted corner error1. Perform corner balance adjustment1. Use matched load cells
2. Mismatched sensors2. Verify output consistency2. Replace same-batch sensors
3. Expired calibration3. Recalibrate whole system3. Annual regular calibration
4. Electromagnetic interference4. Check shield grounding4. Single-point shield grounding
Unstable Output Signal1. Excessive field vibration1. Isolate vibration sources1. Install shock absorption parts
2. Loose wiring terminals2. Fasten all terminals2. Rewire and fasten tightly
3. Internal dampness3. Inspect sealing performance3. Replace sealing parts or sensor
4. Faulty weighing instrument4. Test with spare indicator4. Repair or replace instrument

7.2 Daily Maintenance Suggestions

  1. Perform system calibration once a year to guarantee measuring accuracy
  2. Clean sensor surface every 3 months to remove dust and corrosive deposits
  3. Inspect cables especially connectors every 6 months to avoid disconnection
  4. Regularly monitor ambient temperature and humidity within -40℃~+95℃
  5. Never exceed 333% rated load to avoid permanent sensor damage
  6. Prepare spare sensors for key production equipment to shorten downtime
  7. Order Information & Sélection d'accessoires

8.1 Part Numbers (2026 Official Price List)

Nom du produitNuméro de pièce.Remarques
PR6211/53D1 Load CellPR6211/53D1Standard 5t D1 version, abandonné
PR6212/53D1 Replacement Load CellPR6212/53D1Upgraded fully compatible model
PR6011 Mounting KitPR6011/000Standard assembly with lateral force limiter
PR6012 Advanced Mounting KitPR6012/000With horizontal adjustment function
PR5220 Weight TransmitterPR5220/000Convert mV signal to 4-20mA / Modbus signal
Extension CablePR6211-CAB-1010m extension cable for load cell

8.2 Liste des accessoires

AccessoireModèleFonctionApplication
Standard Mounting KitPR6011/000Prevent lateral force, ensure stable accuracyGeneral tank weighing
Advanced Mounting KitPR6012/000Easy leveling and field calibrationHigh-precision weighing occasions
Weight TransmitterPR5220/000Signal conversion for automatic control systemIndustrial automation projects
Extension CablePR6211-CAB-5/10/15Extend wiring distanceLong-distance sensor installation
Shielded ConnectorPR6211-CONNProtect cable joints against moistureDe plein air & humid environments
Calibration WeightPR-CAL-5tOn-site system calibrationEntretien régulier & accuracy verification
  1. Lignes directrices de sélection & Avoidable Mistakes
  2. Capacity Selection: Keep actual working load between 30%~70% of full scale, avoid overload and light-load errors
  3. Accuracy Matching: Choose D1 for industrial process control, C3 for legal trade weighing
  4. Adaptation environnementale: Select LT version for high temperature, E version for explosion hazardous areas
  5. Mounting Requirement: Must adopt dedicated PR6011/PR6012 kits to eliminate side force interference
  6. Remplacement du modèle: Use PR6212 series directly for new projects due to PR6211 discontinuation
  7. Calibration Cycle: Annual calibration for general industry, semi-annual calibration for high-precision applications

Sartorius PR6211/53D1 is a mature and reliable compact compression load cell widely used for 5-ton level tank and silo weighing. Focus on capacity, classe de précision, working environment and matching mounting kits during selection. Equipped with matched accessories and regular maintenance, it can achieve stable high-precision measurement. Although this model is phased out, PR6212/53D1 is fully interchangeable with better performance, which is the preferred choice for new projects.

Précédent: