3M 7622PST-G2 15kV 3-Core Cold Shrink Indoor Termination - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

3M 7622PST-G2 15kV 3-Core Cold Shrink Indoor Termination - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

NotiziaNotizie commerciali

3M 7622PST-G2 15kV 3-Core Cold Shrink Indoor Termination

3M 7622PST-G2 15kV 3-Core Cold Shrink Indoor Termination (Cable Terminal)

3M 7622PST-G2 15kV 3-Core Cold Shrink Indoor Termination (Cable Terminal)

  1. Model Segment Interpretation
SegmentoSensoOsservazioni
7622Codice serie prodotto3M QTIII 3rd generation cold shrink technology, 8.7/15kV 3-core indoor termination series
PSTStructural type codePre-expanded Silicone Termination, integrated stress control design
G2Specification adaptation codeSuitable for 3×70~3×120 mm² cable conductor, insulation outer diameter 16.0~28.0 mm
Implied ParameterVoltage level / Ambiente di installazione8.7/15kV (15kV system), indoor type (without rain shed), QTIII 3rd generation technology

 

  1. Parametri delle specifiche principali

Parametri Elettrici

ParametroValoreDescrizione
Tensione nominale8.7/15 kV (Massimo 20 kV)Suitable for medium voltage power system, conforme alla CEI 60502 standard
Maximum System Voltage17.5 kVMeets Class 1 termination requirements of IEEE 48-1990 standard
Applicable Cable TypeWire shield / Tape shield XLPE/EPR insulated power cableDedicated for polymer insulated cables; not applicable to oil-impregnated paper insulated cables
Insulation Outer Diameter Range16.0–28.0 mmTypical insulation outer diameter for 3×70 mm² cable (ca. 18–22 mm)
Power Frequency Withstand Voltage45 kV / 1 minFactory test standard to ensure insulation reliability
Partial Discharge≤5 pCQTIII 3rd generation technology, better performance than QTII series (≤10 pC)
Switch Impulse Withstand Voltage95 kVSatisfies system overvoltage protection requirements

Meccanico & Parametri Ambientali

ParametroValoreDescrizione
Materiale isolanteHigh dielectric constant creepage-resistant silicone rubberPermanent radial pressure, excellent weather resistance and aging resistance
Protezione dall'ingressoIP68Fully dustproof and waterproof, suitable for humid indoor environments
Temperatura operativa-40℃ ~ +90℃Ampio intervallo di temperature, adapts to extreme climatic conditions
Vita utile meccanica≥30 yearsMaintenance-free design with long service life
Metodo di installazioneCold shrink type (no heating tools required)Automatically shrinks by pulling out the support core rope for easy installation
Pesoca. 0.8 kg/setComplete with all components, convenient for on-site installation
ColoreNeroStandard industrial color, stain-resistant

Applicable Cable Parameters

ParametroGamma di applicazioneOsservazioni
Conductor Cross-section3×70–120 mm²Suitable for mainstream medium voltage distribution cable cross-sections
Materiale conduttoreRame / AlluminioCompatible with two mainstream conductor materials, no special model required
Insulation Thickness8–12 mmStandard insulation thickness for 15kV cables
Shield TypeBraided copper wire shield / Wrapped copper tape shieldCompatible with two common shielding structures
Overall Cable Outer Diameter35–50 mmTypical outer diameter range for 3-core cables
  1. Elenco degli accessori
Nome dell'accessorioQuantitàScopo
QTIII Cold Shrink Termination Body (with integrated stress control)3 pzProvide insulation and stress control, grease-free design
Cold Shrink Branch Seal Sleeve1 pcSeal cable branch to prevent moisture ingress
Constant Force Spring Grounding Device3 pzShield layer grounding connection, no welding or copper binding wire required
Copper Mesh Grounding Wire3 pzShield layer grounding connection to ensure reliable grounding
Phase Color Marker (Giallo/Verde/Rosso)3 insiemiPhase identification, compliant with power safety regulations
Cleaning Kit (CC-2)1 impostatoPre-clean cable surface to remove oil stains and impurities
Sealing Strip6 pzSeal termination top and cable branch to enhance waterproof performance
Installation Instruction Manual1 copyDetailed illustrated installation guidance
Support Core Rope Pulling Tool1 pcAssist steady rope pulling during installation to avoid termination distortion
  1. Concorrente & Confronto tra marchi
MarcaModelloDifferenza principaleScenario applicativo
Original 3M7622-S-4Outdoor type with rain shed, 15kV, 3×70–120 mm²Outdoor medium voltage distribution equipment connection
Original 3M5601PST-G-CNQTII 2nd generation, 15kV, 3×35–70 mm²Indoor power distribution, progetti a budget limitato
ABBCold Shrink Termination SeriesSimilar structure, slightly higher price, same applicable rangePower system supporting, brand preference
SchneiderCold Shrink Termination SeriesDifferent stress control design, slight difference in installation stepsIndustrial automation system supporting
Alternativa domesticaChangyuan CYLS-15/3.1Price about 1/2–2/3 of 3M, performance meets national standardsProgetti sensibili al budget, non-critical circuits
Alternativa domesticaWalen WRS-15/3.1Prestazioni ad alto costo, same applicable rangeGeneral distribution projects, bulk procurement
  1. Linee guida per la selezione & Soluzioni sostitutive

5.1 Parametri di selezione chiave

Voltage Level Matching: Confirm system voltage is 8.7/15kV; not applicable for systems below 10kV or above 20kV.

Cable Specification Confirmation:

Conductor cross-section: Well compatible within 3×70–120 mm² range.

Insulation outer diameter: Must be within 16.0–28.0 mm with tolerance ≤±1mm, ensuring sufficient radial compression of cold shrink termination.

Shield type: Only applicable to wire/tape shielded cables; not for non-shielded or aluminum sheathed cables.

Ambiente di installazione:

Indoor application: Select 7622PST-G2 (indoor type), compact structure without rain shed.

Outdoor application: Choose outdoor type 7622-S-4 with UV resistance and weatherability.

Installation Tools: No heating tools required; only basic electrician tools and cleaning supplies, single-person installation available.

5.2 Soluzioni sostitutive consigliate

Scenario applicativoRecommended Replacement ModelVantaggi
Direct replacement with same specification3M 7622PST-G2 (3×70–120 mm² applicable)Original genuine product, pienamente compatibile, QTIII 3rd generation technology
Small cross-section adaptation3M 7620PST-G1 (3×35–70 mm² applicable)Fits smaller cross-section cables with lower cost
Large cross-section upgrade3M 7624PST-G1 (3×150–240 mm² applicable)Compatible with larger cross-section cables, reserved for future capacity expansion
Outdoor installation3M 7622-S-4Dedicated outdoor type with rain shed, excellent UV resistance
Cost optimizationChangyuan CYLS-15/3.1High-quality domestic alternative, obvious price advantage, performance meets national standards

5.3 Precauzioni per l'installazione

  1. Cable Pre-treatment

Thoroughly clean cable surface with 3M CC-2 cleaning kit to remove oil stains and oxide layer.

Keep smooth transition at shield cut-off position to avoid tip discharge; professional tools are recommended.

  1. Procedura di installazione

QTIII series: Integrated design without additional stress control mastic required; install branch seal sleeve first, then cold shrink termination body.

Pull the core rope steadily at constant speed to avoid termination distortion and ensure close fitting with cable surface.

  1. Safety Regulations

Installers must hold valid medium voltage cable construction qualification; confirm cable power off and grounding before construction.

Construction site shall be dry and clean; avoid installation in rainy or humid conditions.

  1. Quality Control

Perform insulation resistance test (≥1000 MΩ) and partial discharge test (≤5 pC) after installation.

Record installation date and test data for future maintenance and traceability.

  1. Product Features Summary
  2. QTIII 3rd Generation Technology: Grease-free application, lower partial discharge (≤5 pC), easier installation and higher reliability.
  3. Integrated Design: Built-in stress control unit effectively reduces partial discharge risk and improves insulation reliability.
  4. Installazione semplice: Cold shrink technology requires no heating tools; single-person installation saves construction time and cost.
  5. Forte adattabilità ambientale: Operating temperature -40℃~+90℃, IP68 protection grade, suitable for various harsh indoor environments.
  6. Wide Compatibility: Compatible with multiple specifications of XLPE/EPR insulated cables with high versatility, reducing inventory pressure.
  7. Maintenance-free Design: Silicone rubber provides permanent radial pressure without regular inspection, lowering operation and maintenance costs.