3M QS2000E-I-ABB 18/30kV Single-Core Cold Shrink Straight Joint - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

3M QS2000E-I-ABB 18/30kV Single-Core Cold Shrink Straight Joint - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

NotiziaNotizie commerciali

3M QS2000E-I-ABB 18/30kV Single-Core Cold Shrink Straight Joint

3M QS2000E-I-ABB 18/30kV Single-Core Cold Shrink Straight Joint

3M QS2000E-I-ABB 18/30kV Single-Core Cold Shrink Straight Joint (Cable Splice Joint)

  1. Model Segment Definition
SegmentoSensoOsservazioni
QS2000ECodice serie prodotto3M 2nd generation (QSII) enhanced cold shrink straight joint series, suitable for 18/30kV (24kV) medium voltage systems
IOCodice specificaSuitable for single-core cables, conductor cross-section 50–150 mm², insulation outer diameter 21.3–35.0 mm
ABBSpecial adaptation markInterface customized for ABB switchgear/transformers, ensuring perfect compatibility with ABB equipment
Implied ParameterVoltage level / Struttura18/30kV (24kV) sistema, single-core, cold shrink type, integrated stress control design
  1. Parametri delle specifiche principali

Parametri Elettrici

ParametroValoreDescrizione
Tensione nominale18/30 kV (Massimo 36 kV)Suitable for medium voltage power systems, conforme alla CEI 60502 standard
Maximum System Voltage24 kVMeets requirements of IEEE 48-1990 standard
Applicable Cable TypeCopper wire shielded XLPE/EPR insulated single-core power cableDedicated for polymer insulated cables; not applicable to oil-impregnated paper insulated cables
Insulation Outer Diameter Range21.3–35.0 mmFits typical insulation outer diameter of 50–150 mm² single-core cables
Power Frequency Withstand Voltage65 kV / 1 minFactory test standard to ensure insulation reliability
Partial Discharge≤10 pCStandard performance index for medium voltage joints
Switching Impulse Withstand Voltage170 kVMeets system overvoltage protection requirements
Short-Circuit Current Withstand31.5 IL / 1 SCompatible with short-circuit capacity of mainstream medium voltage systems

Meccanico & Parametri Ambientali

ParametroValoreDescrizione
Materiale isolanteHigh dielectric constant silicone rubberPermanent radial compression, excellent weather resistance and aging resistance
Protezione dall'ingressoIP68Fully dustproof and waterproof, suitable for underground/tunnel/humid environments
Temperatura operativa-40℃ ~ +90℃Ampio intervallo di temperature, adapts to extreme climatic conditions
Vita utile meccanica≥30 yearsMaintenance-free design with long service life
Metodo di installazioneCold shrink type (no heating tools required)Automatically shrinks by pulling out the support core rope for easy installation
Pesoca. 0.9 kg/setComplete with all components, convenient for on-site installation
ColoreNeroStandard industrial color, dirt-resistant

Applicable Cable Parameters

ParametroGamma di applicazioneOsservazioni
Conductor Cross-section1×50–150 mm²Suitable for mainstream medium voltage distribution cable cross-sections
Materiale conduttoreRame / AlluminioCompatible with two mainstream conductor materials, no special model required
Insulation Thickness10–15 mmStandard insulation thickness for 18/30kV cables
Shield TypeBraided copper wire shieldMatches typical shielding structure of single-core cables
Overall Cable Outer Diameter25–40 mmTypical outer diameter range for single-core cables

3.Elenco degli accessori

Nome dell'accessorioQuantitàScopo
QS2000E Cold Shrink Joint Body (with integrated stress control)1 pcCore component providing insulation and stress control
Silicone Rubber Insulation Tube2 pzCable insulation restoration and end sealing
Stress Control Mastic1 impostatoStress control at shield cut-off position, eliminating electric field concentration
Sealing Mastic1 impostatoSeal both ends of the joint to prevent moisture ingress
Cleaning Kit (CC-2)1 impostatoPre-clean cable surface to remove oil stains and impurities
Copper Mesh Grounding Wire2 pzShield layer bridging and grounding connection
Constant Force Spring2 pzShield layer connection, no welding or copper binding wire required
Installation Instruction Manual1 copyDetailed illustrated installation guidelines
Support Core Rope Pulling Tool1 pcAssist steady rope pulling during installation to avoid joint distortion
ABB Special Adaptation Bushing1 pcEnsure perfect interface matching with ABB equipment
  1. Concorrente & Confronto tra marchi
MarcaModelloDifferenza principaleScenario applicativo
Original 3M Standard TypeQS2000E-IWithout ABB special bushing, tipo universaleConnection with non-ABB equipment, general medium voltage systems
Original 3M Large Cross-section TypeQS2000E-IISuitable for 1×95–240 mm², insulation outer diameter 28.0–45.0 mmConnection of large cross-section single-core cables
Original ABBSOT Series Straight JointPrefabricated design, prezzo più alto, seamless compatibility with ABB equipmentABB system matching, high requirement for brand consistency
SchneiderCold Shrink Straight Joint SeriesDifferent stress control design, slight difference in installation proceduresSchneider system matching, industrial automation applications
Alternativa domesticaChangyuan CYLS-30/1.1Price about 1/2–2/3 of 3M, performance meets national standardsProgetti sensibili al budget, non-critical circuits
Alternativa domesticaWalen WRS-30/1.1Prestazioni ad alto costo, same applicable rangeGeneral distribution projects, bulk procurement
  1. Linee guida per la selezione & Soluzioni sostitutive

5.1 Parametri di selezione chiave

Voltage Level Matching: Confirm system voltage is 18/30kV; not applicable for systems below 12kV or above 36kV.

Cable Specification Confirmation:

Conductor cross-section: Well compatible within 1×50–150 mm² range.

Insulation outer diameter: Must be within 21.3–35.0 mm with tolerance ≤±1mm, ensuring sufficient radial compression of cold shrink joint.

Shield type: Only applicable to copper wire shielded single-core cables; not for copper tape shielded or non-shielded cables.

Equipment Compatibility:

Connection with ABB switchgear/transformers: Select QS2000E-I-ABB; special bushing ensures reliable connection.

Connection with other brand equipment: Select standard QS2000E-I for higher universality.

Ambiente di installazione:

Underground/tunnel/humid environment: IP68 protection grade fully applicable.

Outdoor direct burial: Additional protective sleeve required for enhanced mechanical protection.

Installation Tools: No heating tools required; only basic electrician tools and cleaning supplies, single-person installation available.

5.2 Soluzioni sostitutive consigliate

Scenario applicativoRecommended Replacement ModelVantaggi
Direct same-spec replacement3M QS2000E-I (Tipo standard)Original genuine, pienamente compatibile, slightly lower price
Large cross-section upgrade3M QS2000E-IIFits 1×95–240 mm² cables, reserved for future capacity expansion
ABB equipment dedicated3M QS2000E-I-ABBSpecial adaptive bushing, perfect matching with ABB equipment
Cost optimizationChangyuan CYLS-30/1.1High-quality domestic alternative, obvious price advantage, performance meets national standards
Aggiornamento delle prestazioni3M QS3000 Series3rd generation cold shrink technology, lower partial discharge, higher reliability

5.3 Precauzioni per l'installazione

  1. Cable Pre-treatment

Thoroughly clean cable surface with 3M CC-2 cleaning kit to remove oil stains and oxide layer.

Keep smooth transition at shield cut-off position to avoid tip discharge; professional tools are recommended.

Use matched compression terminals for conductor connection to ensure reliable contact.

  1. Procedura di installazione

Install stress control mastic and constant force springs first, then mount the cold shrink joint body.

Pull the core rope steadily at constant speed to avoid joint distortion and ensure close fitting with cable surface.

Install ABB special adaptive bushing to ensure good sealing at equipment interface.

  1. Safety Regulations

Installers must hold valid medium voltage cable construction qualification; confirm cable power off and fully grounded before construction.

Construction site shall be dry and clean; avoid installation in rainy or humid conditions.

  1. Quality Control

Perform insulation resistance test (≥1000 MΩ) and partial discharge test (≤10 pC) after installation.

Record installation date and test data for future maintenance and traceability.

  1. Product Features Summary
  2. Enhanced Cold Shrink Technology: QS2000E series adopts 2nd generation enhanced design with integrated stress control layer for superior insulation performance.
  3. Dedicated ABB Adaptation: Equipped with special bushing to ensure perfect interface compatibility with ABB switchgear/transformers and reduce installation risks.
  4. Installazione semplice: Cold shrink design requires no heating tools; single-person installation saves construction time and cost.
  5. Forte adattabilità ambientale: Operating temperature -40℃~+90℃ with IP68 rating, suitable for various harsh working conditions.
  6. Maintenance-Free Design: Silicone rubber provides permanent radial compression without regular inspection, lowering operation and maintenance costs.
  7. Sicuro & Affidabile: Passed strict factory tests with strong short-circuit current withstand capability to ensure safe system operation.

Prec:

Lascia una risposta

Lasciate un messaggio