Anderson-Negele FMQ050SDMXX Electromagnetic Flow Meter - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

 Anderson-Negele FMQ050SDMXX Electromagnetic Flow Meter - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

NotiziaNotizie commerciali

Anderson-Negele FMQ050SDMXX Electromagnetic Flow Meter

 Anderson-Negele FMQ050SDMXX Electromagnetic Flow Meter

  1. Definizione del codice modello
Segmento di codiceDescrizione
FMQBasic series code: Sanitary electromagnetic flow meter, applicable to food, pharmaceutical and biotechnology industries
50Pipe size: DN50 (2 pollice), inner diameter of measuring tube 50mm
STipo di sensore: Standard sensor with PFA liner for general sanitary applications
DDisplay option: Backlit graphic display with touch button operation, no need to open the housing
MInterfaccia di comunicazione: Standard IO-Link communication, supports simultaneous digital and analog output
XXProcess connection: Customizable connection types (clamp, filo, flangia, ecc.)
  1. Specifiche tecniche principali
CategoriaSpecifiche dettagliateOsservazioni
Parametri di base
Marca / OrigineAnderson-Negele / GermaniaSpecialized in sanitary process instruments, founded in 1947
Tipo di prodottoElectromagnetic inductive flow meterNo moving parts, low-maintenance design
Principio di misurazioneFaraday’s law of electromagnetic inductionInduced electromotive force generated by conductive fluid cutting magnetic field lines
Nominal DiameterDN50 (2 pollice)Corresponding model: FMQ050
Measuring Performance
Campo di misuraFlow velocity: 0.1~10 m/sSuitable for various flow working conditions
Flow rate: 30~280,000 L/h (DN50)
Measuring Accuracy±0.5% of reading ±2 mm/sMaintains high accuracy at low flow velocity
Ripetibilità±0.15% of readingIdeal for filling and batching processes
Fluid Conductivity≥5 μS/cmCompatible with most liquids, pastes and creams
Solid Content≤5% solid particlesAble to measure media containing a small amount of solid particles
Fluid Compatibility
Wetted Materials1.4404 (316l) / 1.4435 acciaio inossidabile, Ra≤0.4 μm (electropolished)Compliant with 3-A sanitary standard, excellent corrosion resistance
Measuring tube liner: PFA
Fluid Temperature-10°C ~ +130°CResists CIP/SIP cleaning at 130°C for 30 minuti
Pressione di esercizioSubject to process connections and seals
Standard clamp connection: 16 sbarra (232 psi)
Parametri Elettrici
Alimentazione elettrica24V DC ±10%, Massimo. 4WLow power consumption design
Output Signals4~20 mA (Load ≤500 Ω), pulse output (Massimo. 1kHz)Dual analog and digital outputs operate simultaneously
IO-Link V1.1 communication
Switch Input1 channel for flow/volume counter reset (opzionale)Improve process control flexibility
Meccanico & Ambientale
Classe di protezioneTransmitter: IP67Resists high-pressure washing and harsh industrial environments
Sensore: IP69K
Materiale dell'alloggiamento316L stainless steelResistente alla corrosione, suitable for sanitary areas
Installation ModeOmni-directional installation, full-pipe operation recommendedBuilt-in empty pipe detection to avoid false readings
Temperatura ambiente-20°C~+60°CWide temperature range for extreme working environments
  1. Difetti comuni & Maintenance Solutions

3.1 Fault Diagnosis Table

Fenomeno di guastoPossibili causePassaggi per la risoluzione dei problemi
No flow display / nessuna uscita1. Insufficient fluid conductivity1. Confirm fluid conductivity ≥5 μS/cm
2. Sensor not fully filled with liquid2. Ensure full pipe flow and eliminate air bubbles
3. Guasto all'alimentazione3. Verify input voltage 24V DC±10%
4. Cablaggio errato4. Check wiring diagram and correct wiring errors
Unstable measured values1. Excessive air bubbles in fluid1. Optimize pipeline venting to remove bubbles
2. Flow velocity below 0.1 m/s2. Keep flow velocity within measuring range
3. Electrode contamination3. Clean electrode surface after power cut-off
4. Poor grounding4. Control grounding resistance ≤10 Ω
Large measuring error1. Incorrect sensor calibration1. Re-calibrate the sensor
2. Electrode scaling2. Chemically clean electrodes following CIP/SIP procedures
3. Massive air bubbles inside fluid3. Optimize pipeline layout to reduce bubbles
4. Improper installation position4. Install sensor on straight pipe section (10D upstream, 5D downstream)
Errore di comunicazione1. Damaged IO-Link cable1. Inspect cable connection and integrity
2. Parametri di comunicazione non corrispondenti2. Confirm IO-Link baud rate and address
3. Internal module failure3. Replace communication module or contact supplier for repair

3.2 Raccomandazioni per la manutenzione

  1. Ispezione giornaliera

Check display status and reading stability weekly

Inspect terminal tightness and cable integrity monthly

Verify sensor installation tightness and pipeline sealing quarterly

  1. Periodic Maintenance

Perform CIP/SIP cleaning at 130°C for 30 minutes every 6 months to keep sensor clean

Inspect electrode condition annually; clean or replace electrodes if necessary

Complete sensor calibration every 2 years to guarantee measuring accuracy

Check liner integrity every 3 years to prevent liquid leakage

  1. Service Life Replacement Cycle

Normal working condition: PFA liner service life 5-8 anni, electrode service life 3-5 anni

Severe working condition (corrosive fluid / frequent CIP cleaning): shorten service life by 30%

  1. Elenco completo dei modelli della serie

Basic FMQ Series Models (By Nominal Diameter)

ModelloDN SizeIntervallo di flusso (L/h)Caratteristiche principaliApplicazione tipica
FMQ010DN10 (1/2″)30~16,000Mini size, alta precisioneMicro-flow batching, laboratory use
FMQ015DN15 (3/4″)30~36,000Struttura compattaSmall-batch food & beverage production
FMQ025DN25 (1″)30~100,000Standard universal typePharmaceutical batching system
FMQ040DN40 (1.5″)30~200,000High flow rate, alta precisioneDairy production line
FMQ050DN50 (2″)30~280,000Mainstream size, standard IO-LinkBrewery industry, beverage filling
FMQ065DN65 (2.5″)30~450,000Large flow rate, elevata stabilitàJuice production line
FMQ080DN80 (3″)30~580,000Extra large flow rate, pressure-resistantEdible oil production
FMQ100DN100 (4″)30~640,000Max pipe size, grado industrialeBulk liquid transportation

Complete Naming Rule

FMQ[Misurare][Sensor Type][Tipo di visualizzazione][Comunicazione][Process Connection]

Misurare: 010~100 corresponding to DN10~DN100

Sensor Type: S=Standard, H=High Temperature, E=Explosion-proof

Tipo di visualizzazione: D=With display, N=No display

Comunicazione: M=IO-Link, A=Analog output, P=Pulse output

Tipo di connessione: T=Clamp, R=Thread, F=Flange

  1. Cross-brand Product Comparison
MarcaModelloDN SizeMeasuring AccuracyDifferenze fondamentaliScenari applicativi
Anderson-NegeleFMQ050SDMXXDN50±0.5% ±2 mm/sStandard IO-Link, PFA liner, IP69K protectionSanitary food & pharmaceutical industry with frequent CIP cleaning
Endress+HauserPromag 50PDN50±0.3% ±1 mm/sHigher precision, molteplici protocolli di comunicazioneHigh-precision pharmaceutical and biotechnology industry
KROHNEOPTIFLUX 1050DN50±0.5% ±2 mm/sConveniente, progettazione modulareMass production of food and beverage
ABBAquaMaster 3DN50±0.5% ±2 mm/sSelf-cleaning electrode, suitable for particle-containing mediaWastewater treatment, papermaking industry
E+HProline Promag HDN50±0.5% ±2 mm/sAlta temperatura & pressure resistance up to 180°CHigh-temperature disinfection process, chemical industry

Punti chiave della selezione

  1. Sanitary Grade: Anderson-Negele FMQ complies with 3-A standard with Ra≤0.4 μm electropolished surface
  2. Communication Performance: Built-in IO-Link facilitates Industry 4.0 system integration
  3. Maintenance Cost: No moving parts plus empty pipe detection reduce maintenance workload
  4. Cleaning Compatibility: Stable performance under 130°C CIP/SIP sanitary cleaning
  5. Cost Performance: Moderate price and stable performance for mid-to-high end applications
  6. Conformità del trasporto aereo & Informazioni sulla certificazione

6.1 Conformità del trasporto aereo

Compliance ItemDescrizione dettagliataOfficial Basis
Hazardous Goods ClassificationNon-hazardous goods, no built-in lithium battery or super capacitorIATA DGR 2026 Special Provision 9
Shipping PackageStandard industrial shockproof and moisture-proof packageIATA DGR 8.1.6
Shipping RestrictionsNo special restrictions, deliverable as general cargoIATA DGR 1.1.3.2
Numero ONUUN number is not requiredNot classified as dangerous goods

6.2 Certificazioni

Tipo di certificatoExecutive StandardApplicable Scope
3-A Certificate3-A Sanitary Standard 74-05Cibo, beverage and pharmaceutical industry
CE CertificateIN 61326-1, IN 61010-1EU and European Economic Area
Certificato ATEXII 3G Ex nA IIC T4 Gc (Opzionale)Explosion hazardous area application
FDA Certificate21 CFR Part 177Food contact material safety certification
EHEDG CertificateEHEDG Type EL Class ISanitary equipment design standard
IO-Link CertificateIO-Link V1.1Industrial fieldbus communication protocol
  1. Scenari applicativi & Guida alla selezione

Scenari applicabili

  1. Cibo & Industria delle bevande

Dairy industry: Flow measurement and batching control for milk, yogurt, cream

Brewery industry: Precise metering for wort, beer and cleaning solution

Juice industry: Concentration juice and syrup conveying & proportion control

  1. Farmaceutico & Biotechnology Industry

Injection production: Accurate filling and conveying of medical liquid

Fermentation process: Flow control of culture medium and additives

Aseptic production: GMP-compliant sanitary flow measurement

  1. Chimico & Cosmetic Industry

Cosmetic production: Process control for emulsion, cream and paste products

Fine chemical industry: Precise metering of high-purity chemicals

Coating industry: Ratio control of pigment and resin

Non-recommended Scenarios

  1. Measuring non-conductive fluid (conductivity<5 μS/cm), ultrasonic flow meter is recommended
  2. Measuring fluid with solid particle content over 5%, Coriolis mass flow meter is recommended
  3. Working pressure over 40 sbarra, special high-pressure flow meter is required
  4. Working temperature below -10°C or above 130°C, customized model is required
  5. Informazioni sull'ordinazione

Modello del prodotto: FMQ050SDMXX (XX stands for process connection type)

Minimum Order Quantity: 1 unità

Tempi di consegna: 10-15 working days for standard models; 20-25 working days for customized models

Specifica di imballaggio: Industrial anti-static package equipped with installation manual and calibration certificate

Periodo di garanzia: 2 years under normal operating conditions

Full Introduction of Domestic Replacement Models for Anderson-Negele FMQ050SDMXX

  1. Recommended Core Replacement Models (Sorted by Matching Degree)

All below models meet core requirements: DN50 sanitary type, PFA liner, backlit display, IO-Link communication (customizable), cibo & pharmaceutical grade certification, compatible with CIP/SIP process, available for direct replacement.

1.1 Hangzhou Meiyi LDG-SUP-050SDM (Prima scelta)

ArticoloSpecifiche dettagliateMatching Explanation
Model Code RuleLDG-SUP-050SDMHighly consistent naming rules and functional modules with original model
LDG=Electromagnetic flow meter series
SUP=Sanitary series
050=DN50
S=Standard PFA liner sensor
D=Backlit graphic display
M=IO-Link communication module
Parametri fondamentaliPrecisione: ±0.5% of reading ±2mm/sFully consistent performance parameters and sanitary standards
Flow velocity range: 0.1~10m/s
Fluid conductivity ≥5μS/cm
Wetted part: 316L electropolished stainless steel + PFA liner
Working temperature: -10°C~+130°C (30min CIP/SIP)
Classe di protezione: Sensor IP69K, Transmitter IP67
Funzione di comunicazioneStandard IO-Link V1.1, 4~20mA analog output, 1kHz pulse output, dual signal simultaneous output100% compatible with original IO-Link functions
Qualifications & Certificazioni3-UN, NSF/ANSI 61, FDA 21 CFR Part 177, EHEDG Type EL Class IMeet strict sanitary requirements of food and pharmaceutical industry
Vantaggio di costo40%~50% price of imported original productsGreatly reduce procurement cost

1.2 Chongqing Chuanyi MFS-050SDM (Leading Domestic Replacement)

ArticoloSpecifiche dettagliateMatching Explanation
ModelloMFS-050SDMFlagship sanitary model for high-end replacement
MFS=Sanitary electromagnetic flow meter series
Parametri fondamentaliPrecisione: ±0.5% of reading ±2mm/sEquivalent performance with reliable state-owned enterprise quality
Ripetibilità: ±0.15% of reading
Working pressure: 16sbarra (clamp connection)
Optional electrode: 316l / Titanium / Hastelloy
Omni-directional installation & automatic empty pipe detection
Featured FunctionsMulti-frequency excitation technology with strong anti-interference abilityMore extended functions than original model
Intelligent self-diagnosis for electrode contamination
Optional PROFIBUS / Comunicazione Modbus
Certificazioni3-UN, CE, Optional ATEX, EHEDGMeet mainstream international sanitary standards
Service Advantage24-hour nationwide after-sales support with sufficient spare partsBetter local service than imported brands

1.3 Liance Instrument LDGW-SIN-050SDM (Cost-effective Replacement)

ArticoloSpecifiche dettagliateMatching Explanation
ModelloLDGW-SIN-050SDMSpecialized in food and pharmaceutical industry with high cost performance
LDGW=Sanitary electromagnetic flow meter
SIN=Liance brand mark
Parametri fondamentaliPrecisione: ±0.5% of readingBasic parameters fully consistent with FMQ050
Flow velocity range: 0.1~10m/s
Fluid temperature: -10°C~+130°C
Classe di protezione: Sensor IP69K, Transmitter IP67
Comunicazione & ProduzioneIO-Link V1.1, 4~20mA, pulse outputIdentical functional configuration with FMQ050SDM
Support flow/volume counter reset switch input
Certificazioni3-UN, FDA, CE, RoHSComply with international food contact safety standards
Livello dei prezzi35%~45% of imported original priceOptimal choice for budget-limited projects
  1. Detailed Technical Parameter Comparison Table
Categoria dei parametriAnderson-Negele FMQ050SDMXXHangzhou Meiyi LDG-SUP-050SDMChongqing Chuanyi MFS-050SDMLiance LDGW-SIN-050SDM
Measuring Performance
Precisione±0.5% of reading ±2mm/s±0.5% of reading ±2mm/s±0.5% of reading ±2mm/s±0.5% of reading
Ripetibilità±0.15% of reading±0.15% of reading±0.15% of reading±0.15% of reading
Flow Velocity Range0.1~10m/s0.1~10m/s0.1~10m/s0.1~10m/s
DN50 Flow Range30~280,000L/h30~280,000L/h30~280,000L/h30~280,000L/h
Fluid Compatibility
Wetted Material316l(Ra≤0.4μm)+PFA linerStessoStessoStesso
Fluid Temperature-10°C~+130°CStessoStessoStesso
Pressione di esercizio16sbarra (clamp)StessoStessoStesso
Fluid Conductivity≥5μS/cmStessoStessoStesso
Elettrico & Comunicazione
Alimentazione elettrica24VDC±10%, 4WStessoStessoStesso
Output Signals4~20mA / Impulso / IO-LinkStessoStessoStesso
Classe di protezioneSensor IP69K, Transmitter IP67StessoStessoStesso
Principali certificazioni3-A/FDA/EHEDG/IO-Link3-A/NSF/FDA/EHEDG/IO-Link3-A/FDA/EHEDG/CE3-A/FDA/CE/RoHS
Price Ratio100%40%~50%45%~55%35%~45%
  1. Key Points for Replacement Selection

3.1 Core Matching Requirements

Consistent Sanitary Standard: Must adopt products certified by 3-A and EHEDG, ensure Ra≤0.4 μm electropolished surface and dead-space-free design

Compatibilità del protocollo di comunicazione: Confirm IO-Link V1.1 version to realize seamless system connection

Equivalent Measuring Performance: Reach standard accuracy, repeatability and low flow measuring capability

Cleaning Resistance: Stable operation under 130°C/30min CIP/SIP cleaning without liner aging

3.2 Differentiated Advantage Comparison

MarcaVantaggi fondamentaliScenari applicabili
Hangzhou MeiyiModerate price, complete IO-Link functions, full certificationsMid-to-high end food & beverage production line, full function compatibility required
Chongqing ChuanyiReliable quality, strong anti-interference, intelligent diagnosis functionGMP pharmaceutical workshop, high stability and long service life required
Liance InstrumentLowest price, prestazione ad alto costo, fast after-sales responseSmall and medium-sized food enterprises with limited budget

3.3 Replacement Implementation Notes

  1. Compatibilità di installazione: All three replacement models adopt standard clamp connection with identical installation dimensions for direct replacement
  2. Corrispondenza del cablaggio: Consistent IO-Link pin definition, no need to modify control cabinet wiring
  3. Parameter Migration: Directly import original range, unit and alarm parameters for quick commissioning
  4. Calibration Verification: On-site calibration is recommended after replacement to meet process precision requirements
  5. Full Series Domestic Replacement Model List

Hangzhou Meiyi LDG-SUP Sanitary Series

ModelloDN SizeConfigurazione principaleApplicazione
LDG-SUP-010SDMDN10Standard, PFA liner, display, IO-LinkMicro-flow batching, laboratory
LDG-SUP-025SDMDN25Standard, PFA liner, display, IO-LinkPharmaceutical batching system
LDG-SUP-050SDMDN50Standard, PFA liner, display, IO-LinkBrewery & beverage filling (replace FMQ050)
LDG-SUP-080SDMDN80Standard, PFA liner, display, IO-LinkEdible oil production
LDG-SUP-100SDMDN100Standard, PFA liner, display, IO-LinkBulk liquid delivery

Chongqing Chuanyi MFS Sanitary Series

ModelloDN SizeConfigurazione principaleApplicazione
MFS-015SDMDN15Standard, PFA liner, display, IO-LinkSmall-batch food production
MFS-040SDMDN40Standard, PFA liner, display, IO-LinkDairy production line
MFS-050SDMDN50Standard, PFA liner, display, IO-LinkJuice production line (replace FMQ050)
MFS-065SDMDN65Standard, PFA liner, display, IO-LinkLarge-flow food production

Liance LDGW-SIN Sanitary Series

ModelloDN SizeConfigurazione principaleApplicazione
LDGW-SIN-025SDMDN25Standard, PFA liner, display, IO-LinkCosmetic production
LDGW-SIN-050SDMDN50Standard, PFA liner, display, IO-LinkFine chemical & pharmaceutical industry
LDGW-SIN-080SDMDN80Standard, PFA liner, display, IO-LinkCoating industry
  1. Quick Selection Reference Table
Demand OrientationModello consigliatoMotivo della selezione
Full function 100% matchingLDG-SUP-050SDMBest IO-Link compatibility and identical model definition
Highest operational reliabilityMFS-050SDMForte anti-interferenza, suitable for core pharmaceutical processes
Strict budget controlLDGW-SIN-050SDMCosto più basso, ideal for batch replacement
Pharmaceutical GMP workshopMFS-050SDMComplete sanitary certifications and intelligent diagnosis
Cibo & beverage production lineLDG-SUP-050SDMBalanced cost performance and efficient after-sales service

Prec:

Lascia una risposta

Lasciate un messaggio