Codice d'ordinazione: 3AUA0000058188
Stato del ciclo di vita: Obsoleto (Classic Maintenance Phase). Spare parts available, long lead-time for new stock; upgrade to ACS380 series is recommended.
- Type Code Decoding
ACS355-03E-07A3-4
| Campo | Descrizione |
| ACS355 | ABB Machinery Guidare Serie |
| 3 | Three‑phase AC power supply input |
| E | Built‑in 50Hz EMC RFI filter |
| 07A3 | Continuous rated output current 7.3 UN |
| 4 | Classe di tensione: 380‑480 VAC three‑phase |
- Nucleo elettrico & Specifiche meccaniche
| Articolo | Parametro |
| Typical motor power rating | 3.0 kW (400 V three‑phase) |
| Rated output current I₂N | 7.3 UN |
| Input power supply | Three‑phase 380‑480 V ±10%, 48‑63 Hz |
| Protezione dall'ingresso | IP20 (cabinet‑mount installation) |
| Dimensioni del telaio | R1 |
| Frequenza di uscita | 0‑600 Hz, vector / Controllo V/F |
| Capacità di sovraccarico | 150% I₂N for 1 min per every 10 min; 180% I₂N peak for 2 s at start‑up |
| Frequenza di commutazione | 4 kHz (predefinito); adjustable from 4 kHz to 16 kHz |
| Built‑in functions | STO Safe Torque‑Off, integrated brake chopper, 8‑step sequence programming, FlashDrop fast parameter download |
| Dimensioni complessive (L×A×P) | 70 mm × 239 mm ×161 mm |
| Peso netto | 1.8 kg |
| Standard delivery scope | Control panel NOT included; panel must be ordered separately |
- Hardware Interface & Native I/O
- Ingressi digitali: 6 DI; Uscita digitale: 1 FARE; Uscita relè:1 Relè
- Ingressi analogici:2 AI; Uscita analogica:1 AL
- Native RS-485 (ModBus RTU); supports plug-in fieldbus option modules
- Dual-channel hardware STO safety terminals (compliant with machinery safety standards)
- Power terminals: L1/L2/L3 power input; U/V/W motor output; BR+ BR-brake resistor terminals; PE protective earth
⚠️ Brake resistor NOT supplied as standard; brake resistor is an external optional accessory.
- Lista imballaggio
✅ Items included in standard package:
- 1 × ACS355-03E-07A3-4 main unit
- I/O control terminal blocks, power terminals, mounting screw kit
- Paper-format installation manual & quick-start guide
- Paper mounting cutout template
❌ NOT included in standard delivery; deve essere ordinato separatamente:
Pannelli di controllo: ACS-CP-A (Advanced panel J400), ACS-CP-C (Basic panel J404)
Fieldbus modules: FPBA-01 (Profibus-DP), FENA-01 (Ethernet/IP / PROFINET), FMBA-01 (ModBus RTU), ecc.
I/O expansion module MREL-01; encoder interface module MTAC-01
External brake resistor, panel extension cable, FlashDrop tool
- Sostituzione compatibile & Soluzioni di aggiornamento
Original model is obsolete; two selection scenarios below:
Opzione 1: Upgrade to ABB ACS380-04-09A5-4 (3 kW,9.5 UN)
Vantaggi: New-generation machinery drive, funzioni migliorate, hardware STO supported, parameter migration tool available
⚠️ Notice: Terminal layout and cabinet mounting cutouts are NOT fully compatible. Cabinet modification is required. I/O definitions differ. Direct plug-and-play replacement is impossible. Rewiring, parameter conversion and commissioning are mandatory.
Opzione 2: Spare-part stock of original ACS355-03E-07A3-4
Vantaggi: Montaggio identico, cablaggio e parametri; direct drop-in replacement
Svantaggi: Limited stock, high unit price, long lead-time; classified as obsolete legacy spare-part stock.
- Scenari applicativi tipici
OEM machinery supporting: trasportatori, macchine per l'imballaggio, attrezzature tessili, woodworking machines, food-beverage processing equipment, small-size pumps & tifosi, simple lifting mechanisms and general-purpose variable-speed applications.
- Note sulla selezione & Application Boundary Conditions
- Temperatura ambiente: Full-rating operation from 0 °C to +40 °C; derating required above 40 °C. Condensation, corrosive gas and heavy dust are prohibited. IP20 rating permits cabinet-only installation; direct field exposure is forbidden.
- This unit is factory-fitted with EMC filter. If input line reactor is added, ensure proper filter earthing.
- For heavy-duty cycles with frequent shock loading, select according to actual motor operating current instead of nominal power rating. If actual motor current exceeds 7.3 A, select the next higher drive frame size.
- Brake chopper is built-in; brake resistor must be externally fitted. Select brake resistor strictly per manual specifications. Never short-circuit BR terminals.
- For valid STO safety function in production operation, both STO channels shall be wired; single-channel short-circuit is prohibited.
- Important Maintenance Guidelines
Service life of R1-frame cooling fan: ca. 3 years; fan replacement is recommended upon expiry.
Retorque power terminals every 6 years.
Annual functional verification test for STO safety function is recommended.
Application Fields of ABB ACS355-03E-07A3-4 (3 kW) Frequenza Convertitore
This is a compact OEM-oriented vector drive with IP20 cabinet-mount rating. It comes with built-in STO Safe Torque-Off, integrated EMC filter and built-in brake chopper. It targets general-purpose variable-speed control for small-to-medium-power stand-alone OEM machinery, and is not intended for heavy-duty continuous high-power drive cycles.
- Confezione & Material-Handling Industry
Trasportatori a nastro, trasportatori a rulli, chain conveyors, attrezzature per lo smistamento
Wrapping machines, sigillanti di casse, macchine reggiatrici, auxiliary palletizing mechanisms
Caratteristiche: Frequent start-stop cycles, smooth speed regulation; STO safety function supports machine safety protection.
- Macchine per la lavorazione del legno
Wood cutting machines, levigatrici, multi-axis milling machines, saws
Material feed mechanisms for wood processing
Punti di forza: 0-600 Hz high-frequency output for high-speed spindles; on-board 8-step sequence programming reduces external PLC hardware requirement.
- Macchinari tessili
Small-scale spinning & weaving auxiliary feeders, macchine avvolgitrici, sizing-machine auxiliary drives
Requisiti: Stable low-speed torque, tension-control capability; suitable for light-to-medium-duty winding tasks.
- Cibo & Beverage Processing Equipment
Small mixing-tank drives, conveyor chains, filling-lines, etichettatrici, macchine selezionatrici
Nota: The drive must be installed inside electrical cabinets. Direct exposure to wash-down / humid environments is not allowed; proper cabinet environmental protection is required.
- Pompe & Tifosi (HVAC & Trattamento delle acque)
Process circulation pumps, water-supply pumps, small centrifugal fans, ventilatori di scarico
Osservazione: Pumps and fans belong to quadratic-torque loads. This drive is applicable; Tuttavia, dedicated fan-pump drives are preferred for large-capacity energy-saving projects.
- Plastica & Rubber Machinery Auxiliary Equipment
Feeder units, nastri trasportatori, small extruder auxiliaries, take-up & pay-off mechanisms
⚠️ NOT recommended for main injection-molding pump drives: Severe shock-loading exceeds the drive’s overload margin.
- Movimentazione dei materiali & Light Lifting Equipment
Light-duty elevators, auxiliary travelling mechanisms for small hoists, small lifting platforms
❗Critical boundary condition: For lifting applications, external brake resistor must be fitted and brake chopper enabled. Operation without brake resistor for lowering loads is strictly forbidden.
- General-Purpose Machine-Tools & Small Processing Equipment
Small grinders, feed drives, small spindle drives.
❌ Non-applicable Conditions (Insidie della selezione)
- Outdoor direct installation (IP20; cabinet-mount only).
- Direct exposure to corrosive atmosphere, heavy conductive dust, condensation or moisture.
- Heavy-shock high-duty-cycle main drives (per esempio. main injection-molding pumps, large winches).
- Field wall-mount installation requiring IP54 / IP65 high-protection rating.
Unit Application Matching Key Points
ACS355-03E-07A3-4 (3 kW /7.3 A) is intended for continuous rated load ≤3 kW motors. 150% overload for 1 min is specified for standard OEM machinery. For applications with frequent shock overload, select one power frame higher.
Full Detailed Parameters of ABB ACS355-03E-07A3-4
Codice d'ordinazione: 3AUA0000058188; Frame size R1; Obsoleto, spare-part maintenance supply only.
- Type-code Explanation
| Segmento di codice | Senso |
| ACS355 | ABB OEM Machinery Drive Series |
| 3 | Three‑phase AC power input |
| E | Built‑in C3‑class EMC RFI filter |
| 07A3 | Continuous output rated current 7.3 A |
| 4 | Valutazione della tensione: 380‑480 V three‑phase |
- Main Electrical Ratings
| Articolo | Valore |
| Typical asynchronous motor power | 3.0 kW @400 V three‑phase |
| Rated output current I₂N | 7.3 UN |
| Tensione in ingresso | Three‑phase 380‑480 VAC ±10% |
| Input frequency | 48‑63 Hz |
| Tensione di uscita | 0 ~ supply voltage (three‑phase) |
| Output frequency range | 0‑600 Hz (controllo vettoriale sensorless) |
| Capacità di sovraccarico | 150% I₂N for 1 min per every 10 min; 180% I₂N peak for 2 s on start‑up |
| Frequenza di commutazione | Default 4 kHz; optional 4/8/12/16 kHz; derating required at high switching frequencies |
| Modalità di controllo | V/F scalare, vettore senza sensori; supports asynchronous & permanent‑magnet motors |
| Built‑in brake chopper ✅ | Standard; brake resistor is external |
| STO Safe Torque‑Off ✅ | Dual‑channel hardware; SIL3 / PL e (ISO 13849‑1) certificato |
| Drive efficiency | Approx.97% under rated load |
| DC bus voltage | 540 Vdc ±15% |
- I/O Terminal Specifications
Native I/O fitted; no mandatory expansion card required. Control panel is optional, not factory-supplied.
| Tipo di segnale | Quantità & Specifica |
| Ingresso digitale DI | 6 canali; PNP/NPN compatible; 12‑24 VDC; impedance 2.4 kΩ; pulse‑input capable:0‑16 kHz |
| Uscita digitale DO | 1 channel transistor output; max 30 VDC,100 mA, short‑circuit protected; max pulse‑output frequency 16 kHz |
| Relay Output REL | 1 canale; contact rating max 250 VAC 5 A;30 VDC 0.5 A; AC/DC compatible relay contact |
| Ingresso analogico AI | 2 canali; configurable ‑10~+10 V voltage /‑20~20 mA current; AI1 impedance >312 kΩ (modalità di tensione),100 Ω (modalità corrente) |
| Uscita analogica AO | 1 canale;0‑20 mA, max driving load 500 Ω |
| Auxiliary 24 V output | 24 VDC ±10%, max 200 mA; for DI & external sensor power supply |
| On‑board communication | Embedded EFB Modbus‑RTU (RS485); compatible with FPBA‑01, FENA‑01 and other fieldbus option modules |
| Safety terminals | X1C dual‑channel STO hardware safety terminals |
- Meccanico & Outline Data
| Articolo | R1 Frame ACS355‑03E‑07A3‑4 |
| Protezione dall'ingresso | IP20 (cabinet‑internal installation); NEMA Open |
| Montaggio | Montaggio su guida DIN / screw‑fixed panel mounting |
| Overall W×H×D | 70 mm ×239 mm ×161 mm (including mounting clips) |
| Peso netto | 1.8 kg |
| Package dimensions | 220 mm ×130 mm ×350 mm; single‑unit carton |
| Raffreddamento | Integrated axial cooling fan; typical fan service life ~3 years |
- Condizioni ambientali
| Articolo | Specifica |
| Temperatura ambiente operativa | 0 … +40 °C full rating; derating above 40 °C; maximum permissible 50 °C (derated); icing and condensation prohibited |
| Temperatura di conservazione | ‑40 … +70 °C |
| Altitudine | Full rating up to 1000 m above sea level; derate 1 % per additional 100 m above 1000 m; maximum operating altitude 2000 m |
| Grado di inquinamento | Operation class 2C2; direct exposure to conductive dust or corrosive gas is forbidden |
| Vibrazione | IEC 60068‑2‑6: 10‑57 Hz amplitude 0.25 mm; 57‑150 Hz 2 g |
| Shock | Trasporto:15 g 11 ms; operativo:2 g |
- Certificazioni & Conformità
CE, UL/cUL, RCM(C-Tick), EAC(GOST-R), RoHS; compliant with Low-Voltage, EMC and Machinery Directives
STO safety function: SIL3 IEC 61508, PL e ISO 13849-1
Built-in E-filter meets C3 industrial-grade EMC requirements
- Built-in Function List
- 8-step on-board sequence programming for reduced external PLC hardware
- FlashDrop fast parameter copy tool support
- Motor thermal-protection, sovracorrente, sovratensione, sottotensione, earth-fault and output-short-circuit protection
- Protezione dallo stallo, mechanical-brake control, Regolatore PID
- Speed-compensated stop, DC-braking, flux-braking
- Multiple parameter-set switching
- Complete fault-history logging, maintenance counters (fan runtime, power-on hours)
- Power Terminal Definition
| terminale | Funzione |
| L1 L2 L3 | Three‑phase AC power input |
| U V W | Three‑phase motor output |
| BR+ BR‑ | Brake‑resistor connection (chopper built‑in; resistor external) |
| PE | Protective earth terminal |
⚠️ Do NOT short-circuit BR+ and BRterminals. Brake resistor must be selected strictly according to manual specifications.
- Option List (Not factory-supplied; order separately)
- Pannelli di controllo: ACS-CP-A advanced panel, ACS-CP-C basic panel
- Fieldbus modules: FPBA-01 Profibus-DP; FENA-01 PROFINET/EtherNet-IP; FMBA-01 Modbus-RTU
- I/O expansion MREL-01; encoder interface MTAC-01
- External brake resistor, panel extension cable, FlashDrop tool
- Application Boundary Notes
- IP20 rating permits cabinet-mount installation only; not suitable for wash-down or humid field environments.
- Lifting-load applications require external brake resistor and activation of built-in brake chopper.
- Current derating is mandatory for ambient temperature 40 °C and altitude 1000 m.
- Legacy obsolete model; spare-part stock availability is limited. Upgrade to ACS380-04-09A5-4 requires cabinet modification and full rewiring.
Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari



















NH42-63-318x560.png)