ABB ACS880-01-246A-4 Variable Frequency Drive - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

ABB ACS880-01-246A-4 Variable Frequency Drive - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

elettrico/

ABB ACS880-01-246A-4 Variable Frequency Drive

The ACS880-01 series is ABB’s flagship wall-mounted industrial single-drive variable frequency drive. Equipped with self-developed DTC Direct Torque Control technology, it supports multiple motor types including asynchronous motors, permanent magnet synchronous motors and synchronous reluctance motors. Integrated with safety, communication and energy efficiency management functions, it serves as the standard drive solution for general industrial ...

  • Dettagli del prodotto

The ACS880-01 series is ABB’s flagship wall-mounted industrial single-drive variable frequency drive. Equipped with self-developed DTC Direct Torque Control technology, it supports multiple motor types including asynchronous motors, permanent magnet synchronous motors and synchronous reluctance motors. Integrated with safety, communication and energy efficiency management functions, it serves as the standard drive solution for general industrial and process industries.

  1. Breakdown of Model Code

`ACS880-01-246A-4`

  1. ACS880: All-compatible industrial single-drive VFD series with standard DTC Direct Torque Control, power coverage ranging from 0.55 kW a 3200 kW across the full lineup.
  2. -01: Wall-mounted single drive module design, available for direct wall mounting or cabinet installation with a compact single-drive form factor.
  3. 246UN: Rated continuous output current of the VFD, 246 UN, the core reference parameter for motor matching and overload protection.
  4. -4: Voltage class identifier, nominally designed for 480 V three-phase power grids, supporting wide input voltage from 380 V to 500 V for various power supply scenarios at home and overseas.
  5. Core Electrical Technical Specifications
  6. Power and Current Ratings
Elemento parametroValoreOsservazioni
Rated Power for Constant Torque (CT / Servizio pesante)132 kW (400 V grid) / 160 kW (480 V grid)For continuous heavy-duty loads such as conveyors and mixers
Rated Power for Variable Torque (VT / Light Duty)160 kW (400 V grid) / 200 kW (480 V grid)For square-torque loads such as fans and water pumps
Rated Continuous Output Current246 UNNominal value under 40 °C ambient temperature
Capacità di sovraccarico110% corrente nominale per 60 S / 150% corrente nominale per 10 SOne overload cycle lasts 5 minuti
Input Power Supply3-phase 380~500 V AC ±10%, 50/60 Hz ±5%Wide voltage design compatible with domestic and overseas power grids
Gamma di frequenze di uscita0 ~ 598 HzSupports high-speed special motor applications
Fundamental Power Factor0.98Low harmonic interference to the grid and low reactive power loss
Nominal Overall Efficiency≥98%Complies with high-efficiency drive standards to reduce operating energy consumption
  1. Controllare le prestazioni

Modalità di controllo: DTC Direct Torque Control, V/f Scalar Control, Controllo vettoriale senza sensori

Torque Step Response: <5 ms in open-loop mode with minor speed fluctuation under load disturbance

Speed Control Accuracy: ±10% rated slip (open-loop); ±0.01% rated speed (closed-loop)

Compatible Motor Types: Asynchronous Induction Motors, Permanent Magnet Synchronous Motors, Synchronous Reluctance Motors, High-Speed Motors

III. Mechanical and Hardware Specifications

ArticoloValore del parametro
Dimensioni del telaioR8
Standard Protection ClassIP20 (standard for cabinet installation)
Optional Protection ClassesIP21 (with cable entry box), IP55 (standalone cabinet type)
Dimensioni complessive (IP21 with Cable Entry Box)H 963 mm × W 681 mm × D 386 mm
Peso netto58.6 kg (IP21 version)
Metodo di raffreddamentoForced air cooling with intelligent temperature-controlled variable-speed fan for low-noise operation
Operating Ambient Temperature-10 °C~ +50 °C; declassamento richiesto sopra 50 °C, maximum withstand temperature +60 °C
Maximum Installation Altitude≤4000 m; 1% declassamento corrente per 100 m sopra 1000 M
Metodo di installazioneVertical wall mounting, side-by-side installation without gaps allowed
  1. Standard Built-in Functions
  2. Funzioni di sicurezza: Standard STO Safe Torque Off function with SIL 3 / PL e safety level, no additional safety relays required.
  3. Hardware Integration: Built-in Class C3 EMC filter, DC reactor and braking chopper, greatly reducing procurement and wiring work for peripheral accessories.
  4. Magazzinaggio & Messa in servizio: Removable STC storage unit for one-click migration of parameters and programs; standard multi-language assistant control panel with Chinese language support.
  5. Basic I/O Interfaces: 6 Ingressi digitali (DI), 3 Uscite digitali (FARE), 2 Ingressi analogici (AI), 2 Analog Outputs (AL), reserved expansion interface for encoders.
  6. Capacità di comunicazione: Built-in Modbus RTU protocol and embedded web server, supporting remote monitoring and parameter configuration over local area networks.
  7. Energy Efficiency Management: Built-in energy optimizer and energy consumption statistics, supporting sleep/wake-up and automatic energy-saving operation modes.
  8. Comprehensive Protection Mechanisms: Complete protection against overcurrent, sovratensione, sottotensione, sovraccarico, surriscaldamento, guasto a terra, cortocircuito, perdita di fase del motore, ecc.
  9. Comparison of Adjacent Models with the Same Voltage Class (-4 Serie)
Modello completoCorrente di uscita nominaleCT Rated Power (480 V)VT Rated Power (480 V)Dimensioni del telaio
ACS880-01-206A-4206 UN110 kW132 kWR7
ACS880-01-246A-4246 UN132 kW160 kWR8
ACS880-01-293A-4293 UN160 kW200 kWR8
  1. Core Selection Differences Between Suffix -3 E -4

Voltage suffixes must be distinguished carefully for domestic project selection to avoid mismatching motors and power grids:

Elemento di confrontoACS880-01-246A-3ACS880-01-246A-4
Intervallo di tensione in ingresso380~415 V AC380~500 V AC
Nominal Applicable GridStandard domestic 380 V industrial power gridOverseas 480 V power grids, foreign-owned production lines
Rated Voltage of Applicable MotorsStandard 380 V domestic motors400/460/480 V imported / export-oriented motors
CT Power at 400 V132 kW132 kW
Full-Load Operation at 480 VNot supported for long-term full-load runningSupports full-load operation of 160 kW-class motors
Scenari applicativi tipiciDomestic general industry, ingegneria comunale, metallurgia, trattamento dell'acquaSupporting export complete equipment, overseas engineering projects, ship supporting systems

> Suggerimento per la selezione: Prioritize models with suffix -3 for standard domestic 380 V grids; suffisso -4 is mandatory for export equipment and 480 V power supply scenarios.

VII. Scenari applicativi tipici

General Machinery: Trasportatori a nastro, screw feeders, miscelatori, frantoi, overhead travelling cranes

Fluid Equipment: Centrifugal fans, axial fans, centrifugal water pumps, pompe per vuoto, screw compressors

Industria di processo: Chemical reaction kettles, metallurgical roller tables, i miei montacarichi, municipal water treatment, food packaging lines

Scenari speciali: Export complete sets of equipment, production line renovation for overseas factories, mine and ship projects with 480 V power supply

VIII. Common Fault Troubleshooting Matrix

Codice erroreFenomeno di guastoCausa ultimaStep-by-Step Solutions
F0001Output Overcurrent TripShort circuit of motor/cable, cambiamento improvviso del carico, excessively short acceleration time, mismatched motor parameters1. Disconnect power and test insulation resistance of motor and power cables; 2. Extend acceleration time parameter; 3. Verifica gruppo 99 motor rated parameters
F0002DC Bus OvervoltageExcessively high grid voltage, excessively short deceleration time, disconnected or over-resistive braking resistor1. Measure three-phase input voltage; 2. Estendere il tempo di decelerazione; 3. Controllare il cablaggio, resistance and power matching of braking resistor
F0011Motor Overload Warning / ViaggioStuck mechanical load, perdita di fase del motore, low overload protection setting1. Rotate motor shaft manually to check mechanical jamming; 2. Verify balanced three-phase motor current; 3. Check overload protection threshold parameters
F0021DC Bus UndervoltagePerdita di fase in ingresso, blown fuse, loose input terminals, excessively low grid voltage1. Inspect three-phase input voltage and phase sequence; 2. Replace blown input fuses; 3. Tighten main circuit wiring terminals
F0030Heatsink OvertemperatureExceeded ambient temperature, blocked cooling air duct, faulty cooling fan1. Clean dust on VFD air intake and cooling fins; 2. Check fan operating status; 3. Lower ambient temperature or run with derated capacity
  1. Ordering and Accessories Description

The order number of the base unit shall comply with results from ABB official selection tools; suffix coding rules for all series accessories are universal.

Common accessory suffixes:

+D150: Upgrade to ACS-AP-W Bluetooth assistant control panel for wireless commissioning via mobile phones/tablets

+B056: Standard factory-matched braking resistor

+E202: Upgrade to Class C2 EMC filter for harsh electromagnetic environments

+K475: PCB conformal coated board for humid, dusty and corrosive harsh environments

+N5050: Built-in Profinet industrial Ethernet communication module

+L502: Incremental encoder interface module for high-precision closed-loop speed control

Full Packing List of Standard Factory Package for ABB ACS880-01-246A-4 (R8 Frame, IP21 Standard Unit)

  1. Core Main Unit (Fully Pre-Integrated from Factory)
  2. ACS880-01-246A-4 Wall-Mounted VFD Main Unit (R8 Frame, IP21)

Factory pre-installed standard internal hardware:

ZCU-12 Main Control Unit (equipped with standard I/O terminals, STO Safe Torque Off circuit, RS485 Modbus and USB commissioning port)

Built-in DC Choke (DCL, standard for R5~R9 frames to suppress harmonics)

Built-in braking chopper (standard for R8 frame, only external braking resistor required)

Conformal coated control board (all standard deliveries come with coated boards)

Complete main power circuit, cooling fans and power terminal copper busbars

Integrated dedicated IP21 cable entry box with separate compartments for main circuit and control cables

  1. ACS-AP-W Bluetooth Assistant Chinese Control Panel (Standard, Detachable)

Supports Bluetooth connection with Drive Composer commissioning software, Chinese/English language switching, parameter setting and fault log viewing.

  1. Matching Installation Hardware Kit (Separate Small Packaging Bag)
  2. Wall-mount fixing bolts and expansion screws for wall installation
  3. Sealing cover for cable entry box, dustproof buckles, rubber cable sealing gaskets
  4. Insulated protective cover for main power terminals and protective cover for control terminals
  5. Lifting eye bolts (special for heavy-duty R6/R7/R8 frames for transportation and hoisting)
  6. Extension mounting buckles for control panel (for external panel mounting on cabinet doors if needed)

III. Paper Documentation Package (Multi-Language Including Chinese)

  1. ACS880-01 Quick Installation and Startup Guide (Chinese Version)
  2. Multi-language safety warning manual (sicurezza elettrica, capacitor discharge, hoisting warnings)
  3. Overall dimension drawings and terminal wiring schematic diagrams
  4. Factory inspection certificate and product nameplate parameter sheet
  5. Brief instructions for optional expansion modules (fieldbus cards, encoder cards, Schede di espansione I/O)
  6. Electronic Documentation CD

Full files contained in the CD:

  1. Complete ACS880-01 hardware manual and firmware parameter manual (cinese & English PDF)
  2. Drive Composer PC commissioning software installation package
  3. Supporting manuals and wiring drawings for all optional modules
  4. Fault code lookup document and motor parameter identification guide
  5. Protective Packaging Auxiliary Materials
  6. Reinforced factory hard carton, load-bearing wooden pallet at bottom (standard wooden pallet for heavy-duty R8 frames for forklift handling)
  7. Shockproof foam corner protectors and bottom buffer foam for the main unit
  8. Plastic moisture-proof dust wrapping film and binding straps

Important Note: Optional Accessories Not Included in Standard Package (Separate Order Required)

  1. External braking resistors and braking units
  2. External EMC input/output filters
  3. Fieldbus adapters (FENA-01 Profinet, FPBA-01 Profibus, ecc.)
  4. FEN-xx encoder interface modules, I/O expansion modules
  5. IP55 protection enclosure kit (order code +B056)
  6. Extension cables for cabinet door-mounted control panels
  7. Input/output AC line reactors
  8. Special customized kits for marine certification, explosion-proof and low-temperature applications

Supplementary Remarks

  1. This list applies to base units with standard IP21 wall-mounted design without additional +Bxx/Cxx special options; if +Bxx/Cxx special options are added during ordering, corresponding accessory assemblies will be included in the package.
  2. R8 frame (including 246A-4) features a heavy main unit with a standard wooden pallet in factory packaging; small frames R1-R5 are supplied without wooden pallets.
  3. ACS-AP-W control panel is a mandatory factory standard accessory and will not be shipped separately. If the economical basic ACS-AP-S panel is required as replacement, specify it during ordering.

Official Overload Capacity Parameters of ACS880-01-246A-4 (Standard Operating Conditions: 40 °C Ambient Temperature, Altitude ≤1000 m)

The overload capacity of this model is divided into two operation modes based on load characteristics: Light Overload (Variable Torque VT) and Heavy Overload (Constant Torque CT). All overload cycles last 5 minuti, with a hardware-limited instantaneous maximum current ceiling. The marking `246A` represents the VFD’s rated output current; voltage suffixes such as -3/-4 do not alter overload current parameters, only the matching motor power.

Modalità operativaBaseline Continuous CurrentOverload MultiplierTypical Matching Motor Power at 480 VTypical Load Scenarios
Rated Non-Overload246 UNN / A160 kWGeneral loads with stable long-term operation
Light Overload (VT Mode)234 UN110%160 kWSquare-torque loads such as fans, centrifugal pumps and screw compressors with minor short-term overload
Heavy Overload (CT Mode)206 UN150%132 kWImpact constant-torque loads such as belt conveyors, miscelatori, crushers and hoisting mechanisms
Instant Startup PeakN / AN / AN / AMotor locked rotor during startup, short-term extreme impact conditions

Key Supplementary Explanations

  1. Hardware Current Limit Constraint: The peak output current of all operating scenarios is capped by IGBT hardware at maximum 350 UN; IL 150% overload current of 309 A under heavy-duty mode is below this ceiling and fully deliverable.
  2. Derating Rules:

If ambient temperature exceeds 40 °C, the rated output current is derated by 1% per 1 °C rise (max withstand temperature 60 °C), with synchronous reduction of overload capacity.

If installation altitude exceeds 1000 M, the rated output current is derated by 1% per 100 m elevation gain.

  1. Meccanismo di protezione: When overload duration or current exceeds specifications, the VFD will trigger an overload warning first; sustained violation will lead to `F0011` motor overload trip, combined with heatsink overtemperature protection for dual safety coverage.
  2. Cambio di modalità: The two overload modes can be switched via parameter `22.02`. The selected mode must match actual load characteristics; prolonged operation beyond rated overload specifications accelerates aging of power components.

Full Cross-Brand Comparison Table for ABB ACS880-01-246A-4 (132 kW per impieghi gravosi / 246 ATTO)

Reference Unit: ACS880-01-246A-4

Core Reference Specifications: 380~500 V wide voltage, 132 kW CT heavy duty, heavy-duty rated current 206 UN, 150% sovraccarico per 60 S; 160 kW VT light duty, light-duty current 234 UN, 110% sovraccarico per 60 S; built-in DC reactor + Filtro EMC + chopper di frenatura + STO safety function.

  1. High-End Foreign Brand Counterparts (Original Imported / Top European & American Brands, Direct Replacement for Heavy-Duty Applications)
MarcaModello completoHeavy-Duty CT Rated CurrentHeavy-Duty PowerLight-Duty VT PowerCore Comparison Description
ABBACS880-01-246A-4206 UN132 kW160 kWReference unit with DTC direct drive, standard STO, built-in reactor, filter and braking unit
SiemensSINAMICS G120C 6SL3210-1KE32-4UB1205 UN132 kW160 kWIntegrated compact unit with built-in STO, suitable for production lines/fans/pumps; cabinet-mounted G130 model 6SL3310-1GE32-6AA3 shares identical specifications
Schneider ElectricATV630D132N4202 UN132 kW160 kWHigh-performance process drive with built-in DC reactor and EMC filter, standard STO, ideal for water treatment and heavy industry
YaskawaGA800 CIPR-GA80B0260ABBA208 UN132 kW160 kWHigh-torque vector control with excellent permanent magnet motor compatibility, dedicated for hoisting and roller table applications
Mitsubishi ElectricFR-A840-03250-2-60234 UN132 kW160 kWA800 high-performance vector drive with built-in filter and multi-protocol communication, for compressors and mixing equipment
Rockwell AutomazionePowerFlex755 20G4ADN260AA0NNNNN260 UN132 kW160 kWMatched for automated production lines with native EtherNet/IP support, for heavy-duty impact loads
  1. Domestic High-End Industrial Counterparts (Domestic Replacement with Equivalent Performance & Lower Cost)
MarcaModello completoHeavy-Duty CT Rated CurrentHeavy-Duty PowerLight-Duty VT PowerCore Comparison Description
InnovazioneMD880-132-4206 UN132 kW160 kWHigh-end domestic industrial drive benchmarked against ACS880, DTC-like torque control, unità di frenatura incorporata, optional STO
InvtCHV200-132-4205 UN132 kW160 kWHeavy-duty vector drive for mining, mixing and conveying equipment
Delta ElectronicsCH2000 132043A204 UN132 kW160 kWUniversal for permanent magnet and asynchronous motors, wide 380~480 V voltage range, filtro EMC integrato
HervitV6-H-4T132G208 UN132 kW160 kWSpecial heavy-duty model for hoisting, wire drawing and mixing applications
  1. Key Replacement Selection Differences & Risk Warnings
  2. Critical Voltage Matching Notes

Reference ACS880-01-246A-4: 380~500 V wide voltage, dedicated for export and overseas 480 V equipment;

The equivalent current model for standard domestic 380 V applications is ACS880-01-246A-3 (380~415 V).

For replacement selection, all matching models must carry suffix 4 (400 V wide voltage); narrow-range 380 V models are forbidden.

  1. Built-in Hardware Differences (Key Points for Retrofit Replacement)
  2. Standard built-in configuration of ABB ACS880: DC reactor + Class C3 EMC filter + chopper di frenatura + STO
  3. Siemens G120C and Schneider ATV630 come with standard STO, but DC reactors are mostly optional and must be purchased separately for replacement to avoid excessive harmonic distortion.
  4. Domestic MD880/CH2000 series feature built-in braking units, while DC reactors are optional for partial specifications.
  5. Core Overload Capacity Comparison (Mandatory for Heavy-Duty Applications)

ABB Reference: CT heavy-duty baseline current 206 UN, 150% sovraccarico (309 UN) sustainable for 60 S

All high-end counterpart models (G120C / ATV630 / GA800 / MD880) deliver equivalent overload performance with heavy-duty current ranging from 202 A a 208 UN

Economical ATV340 / G120XA lack the 150% heavy-duty profile and only support 110% light overload, leading to frequent tripping under impact loads.

  1. Riferimento alle dimensioni di installazione

ACS880-01-246A-4 is R8 frame (963 × 681 × 386 mm, 58.6 kg).

Siemens G120C and Schneider ATV630 models of identical power have smaller footprints with no cabinet expansion required for retrofits; domestic MD880 dimensions are close to ABB, allowing shared mounting cutouts.

  1. Quick Selection Conclusion
  2. Industria pesante / Mixing / Trasmettere / Sollevamento (Constant Torque Heavy Duty): Prioritize Siemens G120C, Schneider ATV630 and Inovance MD880 for fully equivalent replacement in current rating, overload capacity and functions.
  3. Export Equipment / Overseas 480 V Power Supply: Must select wide-voltage models with suffix -4; narrow-range 380 V units are prohibited.
  4. Tifosi & Pompe (Light Duty Without Impact): Economical ATV340 and G120XA are available at lower cost.
  5. Demand for Original Same Platform, DTC Control and Factory Integrated Solution: Directly adopt the same series ACS880-01-246A-4.

Prec:

Lascia una risposta

Lasciate un messaggio