ABB MS116-16 (3P) Interruttore automatico di protezione del motore

MS116: Compact manual motor starter (Interruttore automatico di protezione del motore, MMS) serie. Standard version is inherently 3-pole (3P); no 1P/2P variants available for this model. -16: Thermal trip adjustment range: 10~16 A Original part number: 1SAM250000R1011 Main Electrical Specifications Item Parameter Poles 3P (3-phase main circuit) Thermal trip setting range 10.0~16.0 A Instantaneous short-circuit trip current ...

  • Dettagli del prodotto

MS116: Compact manual motor starter (Interruttore automatico di protezione del motore, MMS) serie. Standard version is inherently 3-pole (3P); no 1P/2P variants available for this model.

-16: Thermal trip adjustment range: 10~16 A

Numero di parte originale: 1SAM250000R1011

  1. Main Electrical Specifications
ArticoloParametro
Poli3P (3-phase main circuit)
Thermal trip setting range10.0~16.0 A
Instantaneous short-circuit trip current IΔ80 UN (fixed electromagnetic trip)
Classe di viaggio10UN (for standard motor starting)
Rated applicable motor power (400V AC-3)Massimo. 7.5 kW
Tensione nominale di isolamento Ui690 V e
Tensione operativa nominale Ue690 V e / 440 A DC
400V service breaking capacity Ics16 IL
MontaggioMontaggio su guida DIN35
Larghezza45 mm (2.5 larghezza del modulo)
TerminaliMorsetti a vite, line-in top / load-out bottom L1/L2/L3 → T1/T2/T3
Integrated functionsProtezione da sovraccarico, protezione da cortocircuito, protezione contro la perdita di fase, funzione di isolamento, compensazione della temperatura, trip-free mechanism
  1. Descrizione della funzione
  2. Funzionamento con manopola rotante: 0 (SPENTO) — I (SU). Clear isolation position, can be used as an isolator.
  3. Protection principle

Sovraccarico: Bimetallic thermal trip

Cortocircuito: Instantaneous electromagnetic tripping

Perdita di fase: Tripping triggered by 3-phase unbalance

  1. Applicazioni tipiche: Standalone 3-phase asynchronous motor protection for fans, pompe, conveyors and packaging machinery.
  2. Accessori opzionali (common for MS116 series)

HKF1-11: Front-mounted auxiliary contact (1NA+1NC)

HKF1-02: Fault signal contact

Sganciatore di minima tensione, sganciatore, 3-phase busbar, lockable handle kit

  1. Linee guida per la selezione

✅ Select when motor rated current falls within 10~16A

⚠️ Optimally set operating current near the middle of adjustment range; avoid continuous operation at the lower limit of 10A

⚠️ For motors with frequent heavy-duty start-up, calculate starting current; upgrade to MS132 series if necessary

🔁 In-platform upgrade alternative: MS132-16 (maggiore potere di interruzione, expanded accessory compatibility); domestic alternatives: Schneider GV2ME16, CHINT NS2-25 (10~16A)

  1. Contrassegni dei terminali

Top terminals: 1L1, 3L2, 5L3 (Power supply incoming)

Bottom terminals: 2T1, 4T2, 6T3 (Motor load outgoing)

Typical Applications of ABB MS116-16 (3P, 10~16A)

Adjustable current range: 10~16A; suitable for 3-phase motors ≤7.5kW @400V. Combines overload, short-circuit and phase-loss protection in one unit, replacing separate circuit breaker + relè termico. Designed for direct-on-line (DOL) motor circuits.

  1. General Industrial Applications
  2. Tifosi (3~7.5kW)

Workshop exhaust fans, dust extraction fans, centrifugal fans, oven circulating fans, ventilatori delle torri di raffreddamento.

Operating feature: Light-load start, funzionamento stabile. Built-in phase-loss protection prevents motor burnout from single-phasing.

  1. Pompe (3~7.5kW)

Pompe di circolazione, pompe dell'acqua di raffreddamento, clean water pumps, small sewage pumps, chilled water circulation pumps for HVAC systems.

Nota: Submersible pumps require level control; confirm motor current is within 10~16A before selection.

  1. Attrezzature di trasporto

Light-duty belt conveyors, trasportatori a rulli, trasportatori a tapparelle, piccoli ascensori.

Suitable for light loads; NOT recommended for frequent forward/reverse impact loads. Upgrade to MS132 for heavy frequent start-stop duty.

  1. Drives for Packaging Machinery

Small carton sealers, conveyor drive motors, macchine avvolgitrici, small mixing motors.

  1. HVAC & Building Services
  2. Condenser fans of central air conditioning units, AHU supply/return fans
  3. Underground car park ventilation fans, auxiliary smoke exhaust fans (excluding primary fire smoke exhaust fans; fire circuits require components complying with local fire codes)
  4. Small circulation pumps for heat exchange stations
  5. Plastica, Lavorazione del legno & Food Light Industry
  6. Feeder motors & stirring motors for small extruders
  7. Spindle motors for wood sanders and small cutting machines
  8. Agitator pumps and conveyor motors for food production lines (ambiente secco)
  9. Trattamento delle acque & Protezione ambientale
  10. Small chemical dosing agitator motors
  11. Small aeration pumps, sludge screw conveyor motors
  12. Drive motors for small filtration equipment

⚠️ Not Recommended Application Scenarios (Insidie ​​della selezione)

  1. Motor rated current <10A or >16A (outside adjustment range)
  2. Heavy-duty high-inrush equipment (air compressor main motors, large crushers) with extreme starting current
  3. Motor circuits requiring star-delta starting or soft starters (MS116 only applies to direct-on-line starting)
  4. High-impact loads and frequent stall conditions
  5. Explosion hazardous areas (explosion-proof enclosure assembly required; unit itself has no Ex certification)
  6. Projects where specifications mandate separate circuit breaker + relè termico (integrated MMS cannot be adopted)

✅ Standard Control Configuration

MS116-16 + ABB Contactor → Direct-On-Line motor starter circuit

Accessori opzionali:

HKF1-11 Auxiliary contact (running status feedback)

HKF1-02 Fault signalling contact (transmit overload/short-circuit trip signal to PLC)

Cross-Brand Equivalent Model List

ABB MS116-16 (3P|10~16A, rotary knob type Motor Protection Circuit Breaker)

Baseline specifications:

Adjustable current 10~16A|3P|Class 10A thermal-magnetic trip|built-in phase-loss protection|DIN rail mount|integrated MPCB/MMS

⚠️ Important note: MS116 adopts rotary knob operation. Schneider GV2ME, Delixi CDP6 base versions use push-button operation. Mounting dimensions are compatible and electrical functions are equivalent, but operating style differs. Confirm operation type according to project requirements.

  1. Imported Brand Direct Equivalents
ProduttoreModelloAdjustment RangeTipo di operazioneKey Remarks
ABB (In-range Upgrade)MS132-1610~16AManopola rotanteUpgraded version of MS116, higher short-circuit breaking capacity, fully interchangeable accessories; preferred OEM replacement
Schneider ElectricGV3P1610~16AManopola rotanteIdentical operation style, direct counterpart; TeSys GV3 series
Schneider ElectricGV2ME20C13~18APulsantePartial overlapping range; not recommended if 10A lower limit is required. GV2ME16C covers only 9~14A (mismatched range, cannot be used as direct replacement)
Siemens3RV2021-4AA1010~16AManopola rotante3RV2021 series, widely used imported alternative for industrial projects
EATONPKZM0-1610~16AManopola rotanteMoeller technology platform, common replacement for overseas machinery
Shihlin ElectricMR-32-1610~16AManopola rotanteTaiwanese brand, popular for localisation of imported equipment
  1. Alternative domestiche (Cost-Effective Solutions)
ProduttoreModelloAdjustment RangeTipo di operazioneApplicazione
CINTNS2-25X 1610~16AManopola rotanteStandard NS2-25 = push-button; suffix X = rotary version, matches MS operation style
Delixi ElettricoCDV2s-32/1610~16AManopola rotanteNew CDV2s rotary series; legacy CDP6-32 mainly push-button
Persone elettricheRMM1S-32/3P 1610~16AManopola rotanteGeneral domestic motor protection circuit breaker
NaderNDM2-32M/3P1610~16AManopola rotanteHigh-end domestic option for control cabinets
  1. Critical Risks for Cross-Brand Replacement
  2. Current Range Hard Limit

MS116-16 = 10~16A

❌ Forbidden substitutions: GV2ME16C (9~14A), 3RV2021-1AA10 (6~10A). Mismatched upper/lower limits lead to ineffective motor protection.

  1. Operating Mechanism Difference

Manopola rotante: MS116, GV3P, 3RV2021, PKZM0

Pulsante: GV2ME, base CDP6, base NS2-25

Standardised cabinet projects & export machinery often require consistent operation form.

  1. Instantaneous Short-Circuit Trip Threshold

ABB MS116 fixed instantaneous trip at 80A. Instantaneous thresholds vary between brands. Verify motor starting current for heavy-start loads to avoid nuisance tripping.

  1. Accessory Incompatibility

Auxiliary contacts and fault signalling contacts from different brands cannot be interchanged. When retrofitting equipment, PLC feedback circuits need matching new accessories.

  1. Shortlist for Direct Procurement

✅ Perfect imported rotary-knob equivalents: Siemens 3RV2021-4AA10 / EATON PKZM0-16 / Schneider GV3P16

✅ ABB factory upgrade option: MS132-16

✅ Cost-effective domestic rotary-knob models: CHINT NS2-25X-16 / Delixi CDV2s-32 (10~16A)