Modulo terminale di uscita Beckhoff ES2008 - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

Modulo terminale di uscita Beckhoff ES2008 - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

elettrico/

Modulo terminale di uscita Beckhoff ES2008

ES2008: EtherCAT 8-channel digital output terminal module, 24 VCC / 0.5 Uno per canale, version with pluggable split wiring base. Its electrical performance is identical to EL2008 of beckhoff, differing only in wiring structure. Differences Between ES / LUI / ED Versions Model Wiring Type Application Scenarios EL2008 Integrated screw terminals, non-pluggable Standard fixed control ...

  • Dettagli del prodotto

ES2008: EtherCAT 8-channel digital output terminal module, 24 VCC / 0.5 Uno per canale, version with pluggable split wiring base. Its electrical performance is identical to EL2008 of beckhoff, differing only in wiring structure.

Differences Between ES / LUI / ED Versions

ModelloTipo di cablaggioScenari applicativi
EL2008Integrated screw terminals, non-pluggableStandard fixed control cabinets with infrequent IO replacement
ES2008Split pluggable wiring baseFast module replacement for equipment after-sales service; no cable re-crimping required
ED2008Integrated spring push-in terminalsCablaggio veloce, tool-free connection
  1. Core Electrical Specifications
  2. Channel Specifications

Output channels: 8-channel single-ended NPN digital outputs

Tensione nominale: 24 VCC (allowable fluctuation range: -15% ~ +20%)

Maximum current per channel: 0.5 UN, equipped with short-circuit protection and reverse polarity protection

Maximum total carrying capacity of power contacts: 10 UN

Permitted loads: Carichi resistivi, inductive solenoid valve loads, indicator light loads

Breaking energy: < 150 mJ per channel (compatible with small solenoid valves)

  1. Tempistica & Isolamento

Turn-on time Ton ≈ 60 μs, Turn-off time Toff ≈ 300 μs

Electrical isolation between E-bus and field loads: 500 VCA

Process image occupation: 8 output bits

  1. Consumo energetico

E-bus supply consumption: Tipico 90 mA

Field supply: 15 mA quiescent current + load current of each channel

  1. Meccanico & Specifiche ambientali

Dimensioni: 12 mm (W) × 100 mm (H) × 68 mm (D)

Peso: ca. 55 G

Montaggio: Standard 35 Guida DIN da mm

Classe di protezione: IP20 (cabinet installation only)

Temperatura operativa: -25 ℃ ~ +60 ℃ (horizontal mounting); massimo. +45 ℃ for vertical mounting

Temperatura di conservazione: -40 ℃ ~ +85 ℃

Umidità: 95% RH, senza condensa

Certificazioni: CE, UKCA, cULus, EAC

Vibrazione / Resistenza agli urti: Conforme alla norma EN 60068-2-6 / IN 60068-2-27

  1. Unique Advantages of ES2008 Pluggable Structure
  2. The wiring base remains permanently on the cable side inside the control cabinet; the module body can be plugged and replaced separately.
  3. No terminal cable disassembly required for equipment fault maintenance, greatly reducing downtime.
  4. The base supports standard wire gauges: 0.08~2.5 mm² solid / stranded wires; 0.14~1.5 mm² for wires with cable lugs.
  5. Standard wire stripping length: 8~10 mm, screw-tightened terminals.
  6. Wiring Definition (Fully Compatible with EL2008)

Common power terminals: 24V+, 0V (unified power supply on module side)

Channel outputs: Ch1~Ch8 (Uscita NPN, uscite 0 V when switched on)

Independent status LED for each channel; green light = output activated

  1. Scenari applicativi tipici
  2. Control of machine tool solenoid valves and cylinder directional valves
  3. Assembly line indicator lights and alarm buzzers
  4. Drive of small relay coils
  5. Output for conveying and material stop cylinders on packaging equipment
  6. Production lines requiring frequent on-site IO module replacement (ES version is preferred)
  7. Sostituzione & Descrizione della compatibilità
  8. Direct interchangeable: ES2008 ↔ EL2008 (fully compatible in programming and EtherCAT configuration, only base structure differs)
  9. High-density alternative: EL4008 (16 FARE, saves DIN rail space)
  10. High-current alternative: EL2024 (4 FARE, 2 A per channel for large solenoid valve driving)
  11. Diagnostic-equipped version: EL2014 (4 FARE, with short-circuit channel fault diagnosis)
  12. Riepilogo della selezione

Choose ES2008: Frequent equipment after-sales maintenance and fast IO module replacement needed

Choose EL2008: Fixed control cabinets with rare cable disassembly, costo inferiore

Choose ED2008: Fast on-site wiring without screwdrivers

Protection Class of Beckhoff ES2008

IP20 (Standard parameter from Beckhoff official manual)

Supplementary Explanation

  1. EL2008, ED2008 and ES2008 in the same series feature identical housing protection structure, all rated IP20.
  2. Definition of IP20 rating:

First digit 2: Prevents ingress of solid foreign objects ≥12.5 mm such as fingers

Second digit 0: No water or dust protection; must not be directly exposed to mist, dust or liquid

  1. Application requirement: Must be installed inside a sealed electrical control cabinet, not for bare installation outdoors, in humid or dusty environments.
  2. If high-protection field IO is required, select EP series EtherCAT junction boxes (IP65 / IP67).

Full List of Beckhoff ES2xxx Digital Output Modules with Pluggable Base (Matching EL2xxx specifications; ES = split pluggable wiring base)

  1. Standard 0.5 A NPN Output (General Solenoid / Indicatore luminoso, IP20)
ES ModelCorresponding EL ModelCanaliSpecification Description
ES2004EL20044 FARE24 VCC, 0.5 Uno per canale, no per-channel diagnosis
ES2008EL20088 FARE24 VCC, 0.5 Uno per canale, general-purpose standard model (the model you enquired about)
ES2014EL20144 FARE24 VCC / 0.5 UN, per-channel short-circuit / overcurrent diagnosis
ES2024EL20244 FARE24 VCC, corrente elevata 2 A per channel for large solenoid valve driving
ES2032EL20322 FARE24 VCC / 2 A with channel diagnosis
ES2034EL20344 FARE24 VCC / 2 A with channel diagnosis
ES2084EL20844 FAREHigh-density 16 larghezza mm, 8-channel capacity condensed into 4 terminali
ES2088EL20888 FAREUltra-slim 16 mm housing, saves DIN rail space
ES2807EL280716 FAREHigh-density 16-channel 0.5 A outputs
ES2809EL280932 FAREHigh-density 32-channel 0.5 A outputs
  1. ES Series with Special Voltage Outputs
ES ModelCorresponding EL ModelCanaliSpecification Description
ES2124EL21244 FARE5 VDC CMOS level output, matching industrial control board signals
  1. Naming Rule Distinction for ES Series (3 wiring versions with identical electrical parameters)
  2. ELxxxx: Integrated screw terminals, non-pluggable, standard low-cost version
  3. ESxxxx: Split pluggable screw base (series that ES2008 belongs to), no cable disassembly during maintenance
  4. EDxxxx: Integrated spring push-in terminals, cablaggio rapido senza attrezzi
  5. EFxxxx: Split pluggable spring push-in base
  6. General Common Parameters of ES2xxx Series
  7. Classe di protezione: All rated IP20, cabinet-use only
  8. Bus isolation: 500 VAC isolation between E-bus and field loads
  9. Alimentazione elettrica: 24 VDC field power, NPN low-side output (uscite 0 V when activated)
  10. Funzioni di protezione: Protezione da cortocircuito, protezione da inversione di polarità, with channel status LEDs
  11. Mechanical width: Standard 24 mm; ultra-slim 16 mm for ES2084 / ES2088
  12. Special DO Modules Without ES Versions in the Same Series (No Split Base Variants, LUI / ED Only)

EL2042: Uscita relè (no ES version available)

EL2062: 230 VAC triac output (no ES version available)

ELX2008: Explosion-proof intrinsically safe output (no ES version available)

TwinSAFE safety outputs EL29xx: No split-base ES variants available

Note di traduzione

  1. Industry standard terms unified:

DO = Digital Output, Guida DIN, NPN low-side output, protezione da cortocircuito, intrinsecamente sicuro, triac, quiescent current

  1. Beckhoff official terminology retained: E-bus, EtherCAT, TwinSAFE
  2. Unit symbols follow international industrial standards (VCC, UN, μs, mJ, mm, ℃, mm²)
  3. Tables maintain original structure for engineering document direct use

Prec:

Prossimo:

Lascia una risposta

Lasciate un messaggio