B&R X20DO9322 Digital Output Module

Model Code Breakdown Field Description X20 B&R X20 distributed I/O system series DO Digital Output 9322 Channel specification code: 12-canale, 24 VCC, Source output, 1-wire wiring Derivative Model X20cDO9322 Conformal coated version, suitable for environments with condensation and corrosive gases Core Electrical Parameters Number of Channels: 12 digital transistor outputs Output Type: Source output (PNP, positive ...

  • Dettagli del prodotto

Scomposizione del codice modello

CampoDescrizione
X20B&R X20 distributed I/O system serie
FAREUscita digitale
9322Channel specification code: 12-canale, 24 VCC, Source output, 1-cablaggio a filo
Derivative Model X20cDO9322Conformal coated version, suitable for environments with condensation and corrosive gases
  1. Parametri elettrici principali

Numero di canali: 12 digital transistor outputs

Tipo di uscita: Source output (PNP, positive switching), 1-cablaggio a filo

Tensione nominale: 24 VCC (raggio d'azione: 20.4 ~ 28.8 VCC)

Corrente nominale per canale: 0.5 UN

Maximum Total Module Current: 6 UN (upper limit for sum of all channels)

Switching Element: Forward-mode FET with integrated freewheeling diode (compatible with inductive loads such as solenoid valves)

Cortocircuito / Protezione da sovraccarico: Independent hardware current limiting and thermal shutdown per channel; software channel fault diagnosis supported

Consumo energetico: 0.26 W (bus side); 1.15 W (internal I/O circuit)

B&R Hardware ID Code: 0x1B9A

  1. Mandatory Matching Accessories (Ordered Separately, Not Included with Module)
  2. Bus Base Unit (Choose One)

X20BM11: Standard bus module, no node address DIP switch

X20BM15: Bus module with node address DIP switch

  1. Morsettiera: X20TB12 (12-pin pluggable terminal)
  2. Ambientale & Specifiche meccaniche

Classe di protezione: IP20 (solo per montaggio in armadio)

Temperatura operativa: -25 ℃ ~ +60 ℃

Temperatura di conservazione: -40 ℃ ~ +85 ℃

Larghezza del modulo: 12.5 mm

Certificazioni: CE, cULus, ATEX Zone2 / Class1 Div.2

  1. Confronto chiave: X20DO9322 VS X20DO9321 (Frequently Confused Models)
ModelloTipo di uscitaMetodo di cablaggio
X20DO9322Fonte (PNP)1-filo
X20DO9321Lavello (NPN)1-filo

⚠️ Not directly interchangeable: Reverse wiring polarity may lead to load malfunction or component burnout!

  1. Istruzioni di cablaggio (1-Wire Source Type)

Module output terminal → Positive terminal of load

Negative terminal of load → External 24 VCC 0 V

No common negative wiring back to the module (characteristic of 1-wire design)

Suitable loads: Indicator lamps, piccolo 24 Elettrovalvole VDC, intermediate relay coils

  1. Scenari applicativi tipici

Macchine per l'imballaggio, plastic injection & extrusion machinery, material handling conveyor lines, macchine tessili, auxiliary switching outputs for machine tools; ideal for centralized control of large quantities of 24 VDC solenoid valves and signal lamps.

  1. Note sulla selezione & Common Pitfalls
  2. If Sink (NPN) output is required → Select X20DO9321 instead of X20DO9322
  3. For humid, oily or condensation-prone environments → Order X20cDO9322 (conformal coated version)
  4. If channel current exceeds 0.5 A → Upgrade to X20DO8332 (8-canale, 2 Uno per canale)
  5. Do not drive high-power contactors directly; install intermediate relays as adapters
  6. Fault Diagnosis Guidelines

Channel LED off: No output command / module power loss

Channel LED on but load inactive: Missing external 24 VDC supply or open circuit

Recurring channel fault alarms: Load short-circuit, or missing freewheeling diode for inductive loads

Applicable Industries & Operating Conditions of B&R X20DO9322 (12-canale 24 VDC PNP Source 1-Wire Digital Output Module)

Posizionamento centrale: Mainstream I/O Module for OEM Machinery. Designed to drive a wide range of small 24 VDC loads (pneumatic solenoid valves, spie luminose, intermediate relays). The 1-wire architecture reduces cabling costs. Independent per-channel short-circuit protection makes it well suited for machinery automation, B&R’s core market segment.

X20cDO9322 (coated variant) for humid, oily and mildly corrosive environments.

  1. Priority Target Industries (Proven Mass Deployment for B&R Projects)
  2. Macchine per l'imballaggio (Highest-volume Application)

Attrezzatura: Verticale / horizontal packaging machines, flow wrappers, case packers, palletizers, case sealers, macchine per soffiaggio, heat shrink equipment

Module Functions: Control solenoid valve banks for cylinders, conveyor start/stop, alarm lamps, reject mechanisms, gripper actuation

Vantaggio della selezione: Equipment often requires multiple valve outputs; high channel density (12 canali). PNP output matches mainstream European & American pneumatic components.

  1. Iniezione di plastica & Extrusion Machinery

Attrezzatura: Macchine per stampaggio ad iniezione, macchine per soffiaggio, extrusion lines, pelletizing equipment, mold auxiliary mechanisms

Funzioni: Solenoid valves for mold core pulling/ejection, cooling valves, hopper gates, pompe di lubrificazione, fault indicator lamps

  1. Stampa, Carta, Nonwoven & Macchinari tessili

Stampa: Offset printers, flexographic printers, die-cutters; Tessile: Macchine per maglieria in ordito, circular knitting machines, textile finishing equipment

Funzioni: Cylinders for tension control, cutting solenoid valves, fabric guiding mechanisms, pneumatic directional valve banks

  1. Movimentazione dei materiali & Sorting Automation

Attrezzatura: Linee di smistamento, roller conveyor systems, auxiliary warehouse equipment, transfer machines, cross-belt sorters

Funzioni: Solenoid valves for sorting diverters, switch rails, photoelectric warning lamps, stopper cylinder control

  1. Cibo & Bevanda / Attrezzature farmaceutiche

Attrezzatura: Linee di riempimento, capping machines, sistemi di pulizia, pharmaceutical filling machines, blister packaging equipment

Nota: Standard model only for dry electrical cabinets. X20cDO9322 conformal coated variant is mandatory if workshop contains water mist or cleaning spray.

Carichi: Filling valves, clamping cylinders, conveyor control, status indicator lamps

  1. Macchine utensili & Metalworking Equipment

Attrezzatura: Custom CNC machines, automated fixtures, smerigliatrici, stamping automation loading/unloading systems

Funzioni: Clamping cylinders, coolant valves, lubrication systems, machine warning lamps, auxiliary safety interlock outputs

  1. New Energy Lithium-ion Battery Front-end Equipment

Attrezzatura: Electrode slitting machines, calendering equipment, cell assembly tooling, vacuum packaging machines

Nota: Use coated variant for environments exposed to electrolyte mild corrosion

Applicazione: Pneumatic actuators for tooling fixtures

  1. Secondary Applicable Industries (Common Projects, Non-primary Application)
  2. Automotive Component Automation

Tooling fixtures, banchi prova, auxiliary welding mechanisms; drive pneumatic clamping valves and signal lamps.

  1. Trattamento delle acque & Municipal Environmental Equipment

Control of small valves, intermediate relays for pumps, local audible & visual alarm outputs (cabinet-mounted installation).

  1. Marino & Shipboard Automation

DNV marine certification available; suitable for control cabinets inside vessel compartments for auxiliary machinery signal outputs.

  1. Small-scale Renewable Energy Control (Wind Turbine Auxiliary Cabinets, PV Monitoring Cabinets)

Alarm signals and small actuator switching control.

  1. Non-recommended / Restricted Application Scenarios (Selection Red Lines)
  2. Continuous channel load current >0.5 A → Replace with X20DO8332 (8-canale, 2 A/channel)
  3. Lavello (NPN) output required → Select X20DO9321; cannot directly substitute X20DO9322
  4. Direct drive of high-power contactors: FORBIDDEN; intermediate relay transition required
  5. Outdoor installation without enclosure: IP20 rating prohibits exposed outdoor mounting
  6. Severe chemical corrosion and high salt spray with no sealed cabinet: Use with caution; evaluate alternative series or enhanced enclosure protection
  7. Adatto & Unsuitable Load Summary

✅ Recommended Loads

24 VDC pneumatic solenoid valves, signal indicator lamps, small intermediate relays, solid-state relays (RSS)

❌ Not Suitable Loads

Motori CC, high-power heating elements, high-current contactors

Additional Practical Design Recommendations

Machinery exported to Europe & America: Most pneumatic equipment adopts PNP positive switching circuit. X20DO9322 is the preferred option.

Many domestic system integrators use NPN control circuits. Verify electrical drawing polarity before purchasing to avoid ordering X20DO9321/X20DO9322 incorrectly.

Systems with large numbers of inductive solenoid valves: Fit freewheeling diodes across valve coils to minimize channel fault alarms.

Complete Official Technical Specifications – B&R X20DO9322

Model Reminder: X20DO9322 (Letter O, not digit 0; X20D09322 is a typo)

Derivative Variant: X20cDO9322 (Conformal Coated)

  1. Informazioni di base
ArticoloSpecifica
ModelloX20DO9322; Conformal coated: X20cDO9322
Tipo di moduloX20 distributed digital output module (FARE)
B&R Hardware ID CodeX20DO9322: 0x1B9A; X20cDO9322: 0xD578
Configurazione del canale12-channel digital transistor output
Tipo di uscitaFonte / PNP positive switching (forward-mode FET)
Wiring Format1-Wire topology (module only provides positive control wire; load negative connected to external 0 V)
Compatible Base UnitsX20BM11 (No DIP switch) / X20BM15 (With node address DIP switch)
Matching Terminal BlockX20TB12 (12-pin pluggable terminal, ordinato separatamente)
  1. Specifiche elettriche principali
ParametroValoreOsservazioni
Nominal Supply Voltage24 VCCPermissible range: 20.4 ~ 28.8 VCC (-15% ~ +20%)
Continuous rated current per channel0.5 UNDo not exceed continuously
Maximum total output current of module6 UNSum limit for all 12 canali
FET On-resistance Rds(SU)210 mΩConduction power loss
Off-state leakage current≤5 µAMinor residual current when output disabled
Peak short-circuit current<12 UNHardware current limiting
Cortocircuito / Protezione da sovraccaricoIndependent thermal shutdown per channelAuto-retry approx. 10 ms after fault removal
Circuitry for inductive loadsIntegrated freewheeling diodeTypical clamping voltage: 50 VCC
Isolamento elettricoChannel ↔ X20 bus: 500 VAC isolationCommon-ground multi-channel system
No isolation between individual channels
Maximum Switching Frequency100 HzNot designed for high-speed pulse outputs
  1. Power Consumption Data
  2. X20 communication bus power draw: 0.26 W
  3. Static internal I/O circuit power consumption: 1.15 W
  4. Additional loss for resistive loads: +0.63 W
  5. Diagnostica & Indicatori LED

Module run / fault LED; Independent status LED for each channel

Software diagnostic support: Channel short-circuit and overload fault reporting

Fault detection delay: 10 SM

Fault status readable via Automation Studio

  1. Ambientale & Dati meccanici
ArticoloSpecifica
Classe di protezioneIP20 (cabinet installation only)
Temperatura ambiente operativa-25 ℃ ~ +60 ℃
Magazzinaggio / Temperatura di trasporto-40 ℃ ~ +85 ℃
Mounting StandardDA 35 mm rail vertical mounting (standard X20 layout)
Larghezza del modulo12.5 mm
Pesoca. 35 G (excluding base unit and terminals)
Relative Humidity Range5%~95 %, senza condensa
⚠️ X20cDO9322 mandatory for condensation-prone environments
  1. Certification List

CE, UKCA, cULus, cCSAus

ATEX II 3G Ex nA nC IIA T5 Gc (Zona 2)

HazLoc: Class I Div.2 A,B,C,D T5

DNV Marine Type Approval (for cabinet installation on vessels)

  1. 1-Wire Source Wiring Principle
  2. Module terminal → Load positive terminal (+24 V control)
  3. Load negative terminal → External DC power supply 0 V

The module has no dedicated common 0 V terminal; different from 3-wire modules.

  1. Confronto dei modelli: X20DO9322 VS X20DO9321
    ModelloTipo di uscitaSelection Guidance
    X20DO9322PNP SourcePreferred for European & American equipment, compatible with mainstream Festo / SMC solenoid valves
    X20DO9321NPN SinkFor control circuits using negative switching, common in domestic OEMs

    Load Operating Limits

✅ Recommended Loads

24 VDC pneumatic solenoid valves, signal lamps, small intermediate relays, solid-state relays (RSS)

❌ Direct Drive Prohibited

High-power contactors, Motori CC, heating loads; loads exceeding 0.5 Uno per canale

  1. Regole di selezione critica
  2. Umido, oleoso, condensation-prone environments → X20cDO9322 conformal coated version required
  3. Higher channel current demand → X20DO8332 (8 canali, 2 Uno per canale)
  4. Not suitable for high-speed pulse outputs (massimo. switching frequency limited to 100 Hz)
  5. Interchangeable Alternative X20 DO Module Comparison Table for X20DO9322

Applicazione: Sostituzione pezzo di ricambio, hardware revision, cost optimization and operating condition upgrade reference

⚠️ Important Reminder: Direct hardware interchange is impossible if output polarity (PNP/NPN), wiring topology or single-channel current rating differ. Wiring and program modifications will be required.

ModelloCanaliKey CharacteristicsDirect Swap for X20DO9322Typical Retrofit Scenario
X20DO932212Standard model for solenoid valve controlReference baselineStandard original design
X20cDO932212Conformal coated✅ Fully electrically compatible; base and terminals interchangeableCabinet with condensation, oil mist or mild corrosive gas
X20DO932112Opposite polarity❌ Cannot swap directly; load wiring reversal neededSystem specification requires NPN circuit
X20cDO932112NPN + conformal coating❌ Polarity mismatchHumid environment with NPN circuit requirement
X20DO63228Fewer channels⚠️ Electrical characteristics match; insufficient channel count prevents direct useEquipment retrofit with reduced output points
X20DO83328High-current output❌ Different wiring topology (non-1-wire)Load current >0.5 UN, drive large relays / valvole
X20DO43224Low-channel expansion❌ Different wiring topologyLocalized small-scale I/O expansion
X20DO933212With dedicated common 0 V terminal❌ Different wiring & pinoutControl systems requiring centralized 0 V connection on module side

Core Replacement Guidelines

  1. Zero-modification direct swap: X20cDO9322 ↔ X20DO9322

X20BM11/BM15 base units, X20TB12 terminals and Automation Studio hardware configuration are fully compatible; no drawing or wiring changes required.

  1. Replacing X20DO9322 with X20DO9321

Hardware: Reverse all load positive/negative wiring

Software: Change module model in Automation Studio hardware configuration; control logic remains unchanged

  1. 3-wire DO modules (DO9332 / DO8332 etc.) must NOT directly replace 1-wire X20DO9322

Different terminal assignment and power circuit architecture. Powering up mismatched hardware may cause load failure or component damage.

Supplementary Selection Advice

For new projects with large quantities of solenoid valves: Prioritize X20DO9322; 1-wire topology reduces cabling.

Frequent short-circuit faults or high individual valve current: Upgrade directly to X20DO8332.

Equipment for export to Europe & America: PNP series preferred. Confirm control circuit polarity before ordering for domestic non-standard machinery.