Contattore CA CHINT NXC-65A - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

Contattore CA CHINT NXC-65A - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

contattore/

Contattore CA CHINT NXC-65A

  Model Segment Description NXC Product series code: Contattore CA serie CHINT KunLun, upgraded replacement for traditional CJX2 series 65 Corrente operativa nominale: 65UN (under AC-3, 400V) A Configuration code: Tipo standard (no suffix = standard; suffix /N = reversing type) Common Suffix Coil voltage code: 220V / 380V / 110V / 24V, per esempio. NXC-65 ...

  • Dettagli del prodotto

 

Segmento modelloDescrizione
NXCCodice serie prodotto: Contattore CA serie CHINT KunLun, upgraded replacement for traditional CJX2 series
65Corrente operativa nominale: 65UN (under AC-3, 400V)
UNConfiguration code: Tipo standard (no suffix = standard; suffix /N = reversing type)
Common SuffixCodice tensione bobina: 220V / 380V / 110V / 24V, per esempio. NXC-65 220V

Full Model Example:

NXC-65 220V 50Hz = CHINT KunLun 65A AC contactor, tensione bobina 220V, 50Hz, configurazione standard

Typical Order No.: 710010100000281 (NXC-65 220 V 50 Hz, 1NA+1NC)

  1. Main Technical Data
CategoriaSpecificheOsservazioni
Informazioni di base
Marca / SerieCHINT Electric / KunLun NXC SeriesStruttura compatta, direct replacement for CJX2-65
Tipo di prodotto3-phase AC ContactorFor frequent motor starting & remote circuit switching
Standard di conformitàGB/T 14048.1 / CEI 60947-1, GB/T 14048.4 / CEI 60947-4-1International certified, sicuro e affidabile
Dati elettrici
Corrente operativa nominale (Cioè)65UN (AC-3, 400V)Main contact rated current
Tensione operativa nominale (Ue)380V / 400V (50Hz)Standard industrial grid voltage
Tensione di isolamento nominale (Ui)690VMax withstand voltage of insulation system
Tensione nominale di resistenza all'impulso (Ump)8kVOvervoltage protection capability
Tensione della bobina di controlloOptional AC 24V / 36V / 110V / 220V / 380VSelected according to control system
Frequenza della bobina50 / 60HzCompatibilità con la rete globale
Frequenza operativa nominale1200 cycles/h (AC-3)High frequent operation capability
Capacità di interruzione10× rated currentShort-circuit withstand capability
Configurazione dei contatti
Contatti principali3NO (3-polo normalmente aperto)Standard for main power circuit
Contatti ausiliari1NO + 1NCExpandable on request
Auxiliary Contact Rating5UN / 220V eFor control signal circuits
Caratteristiche fisiche
Dimensioni (L×A×P)90mm × 150mm × 105mmCompatto, salvaspazio
Pesoca. 0.8kgLightweight for easy installation
MontaggioGuida DIN standard da 35 mm / montaggio a viteSnap-on design, fast assembly
Classe di protezioneIP20Suitable for cabinet installation
Temperatura operativa-30℃ ~ +60 ℃Wide temperature range for harsh environments
Temperatura di conservazione-25℃ ~ +40 ℃Suitable for transportation & warehouse storage
Electromagnetic Performance
Potenza della bobinaca. 180VA (pick-up) / 25VA (presa)Basso consumo energetico, energy-saving
Drop-out Voltage30% ~ 70% della tensione nominaleReliable disconnection
Electromagnetic SystemOptimized silicon steel lamination (32-piece core)Smooth closure, basso rumore & loss
Caratteristiche di sicurezza
CertificazioniCE, CCCDomestico & international compliance
Arc ExtinctionMulti-channel magnetic blow-out arc suppressionHigh breaking performance
Funzioni di protezioneSovracorrente, surriscaldamento, undervoltage protectionComprehensive equipment & circuit protection
  1. Accessory List
AccessorioModelloFunzionePosizione di montaggio
Auxiliary Contact BlockAX-3M/20 (2NO), AX-3M/02 (2NC), AX-3M/11 (1NA+1NC)Expand auxiliary contacts for complex logicTop front
Time Delay ModuleF5-08 (0.1~30s), F5-11 (0.1~180s)In ritardo / off-delay controlTop
Soppressore di sovratensioniSR2-220, SR2-380Suppress coil surge voltageBottom
Interblocco meccanicoNXC-ILPrevent phase short circuit for reversing contactor (NXC-65/N)Side
Mounting Rail35Guida DIN standard da mmInstallazione fissaInside control cabinet
Terminal Protection CoverStandard equippedAnti-touch protectionPrincipale & auxiliary terminals
Mounting ScrewsM4×12mmFissaggio a viteBase mounting holes
Operation ManualElettronico / hard copyInstallazione, commissioning & maintenance guide
Coil ConnectorOpzionaleFast coil wiring & sostituzioneCoil terminal side
  1. Cross-Brand Equivalent & Sostituzione
MarcaSerieModelloCorrente nominaleDifferenzeCompatibilità di sostituzione
CINTCJX2CJX2-651165UNOld generation; NXC is fully upgraded versionDirect full replacement (same mounting size)
SchneiderTeSys DLC1D65M7C65UNImport brand, costo più elevato, funzioni similiAlto (verify mounting & contatti ausiliari)
Siemens3RT3RT2026-1BB4065UNProgettazione modulare, hot-swap supportMedio (different dimension & cablaggio)
ABBDIAF65-30-1165UNWide-voltage coil, global applicationMedio (needs position adjustment)
MitsubishiS-NS-N6565UNCompact Japanese design, prezzo moderatoMedio (different terminal layout)
ChangshuCK3CK3-6565UNDomestic equivalent, same performanceAlto (fully compatible size & mounting)
  1. Funzioni principali & Applicazioni

Funzioni principali

  1. High-efficiency Electromagnetic System: Optimized core structure for stable closure, low noise and low energy consumption.
  2. Highly Reliable Arc Suppression: Magnetic blow-out technology with 10× rated breaking capacity for higher safety.
  3. Espansione flessibile: Supports auxiliary contacts, timer modules and surge suppressors for customized control.
  4. Installazione semplice: Snap-on DIN rail mounting for fast assembly and maintenance.
  5. Wide Temperature Adaptation: Stable operation from -30℃ to +60℃ for various industrial environments.

Applicazioni tipiche

  1. Controllo motorio: Frequent start/stop/reverse of 3-phase asynchronous motors (ca. 30kW@400V).
  2. Automazione industriale: Production lines, trasportatori, tifosi, water pumps and general machinery.
  3. Building Electrical: Sistemi HVAC, fire water pumps, elevator auxiliary circuits.
  4. Macchine utensili: Spindle control for milling machines, drilling machines and small machining centers.
  5. Distribuzione dell'energia: Combinato con relè termici (Serie NR2) for complete motor protection starters.
  6. Note supplementari
  7. Product Upgrade: The NXC KunLun series fully replaces the traditional CJX2 series with improved mechanical structure, electromagnetic performance and expandability.
  8. Linee guida per la selezione:

Select current rating according to motor power (65A matches approx. 30kW motor).

Confirm coil voltage (220V / 380V most common).

Expand auxiliary contacts via AX series modules if signal points are insufficient.

  1. Suggerimenti per la manutenzione:

Regularly check contact wear; replace contacts when excessive contact resistance occurs.

Keep the contactor clean from dust and moisture.

Apply periodic energization (1–2 times monthly) for long-term idle equipment to prevent coil dampness.

CHINT Contactor Full Series List

  1. Product Series Overview
SeriePosizionamentoIntervallo correnteCaratteristicheReplacement Relation
NXCKunLun Main Series6A ~ 630ACompatto, modular, high cost-performanceFull replacement for CJX2
NC5High-performance Intelligent Series9A ~ 630ASmart control, energy-saving, high stabilityHigh-end alternative to NXC
CJX2Classic Traditional Series9A ~ 95AMature model, convenienteGradually phased out by NXC
NXCFSlim Compact Series9A ~ 32AUltra-thin, salvaspazioSmall cabinet & compact installation
NC8Heavy-duty Industrial Series9A ~ 500AHigh mechanical life, strong arc resistanceFrequent start-stop working conditions
NXCCCapacitor Switching Contactor16A ~ 100AInrush current suppression, reactive power compensation dedicatedCapacitor bank control
NCH8Household & Building Series16A ~ 63AMiniature size, building automationIlluminazione, HVAC & residential control
CJ40 / CJ20High-power Heavy Series100A ~ 630AHeavy-load design for large motorsHeavy industrial equipment
  1. NXC KunLun Series Main Model List (AC-3 400V)
Corrente nominaleModello standardReversing ModelStandard Aux. ContattoMatched Motor PowerOrdine n.
6UNNXC-06M1NA+1NC0.75kW710010100000276
9UNNXC-09NXC-09/N1NA+1NC1.5kW710010100000277
12UNNXC-12NXC-12/N1NA+1NC2.2kW710010100000278
18UNNXC-18NXC-18/N1NA+1NC3kW710010100000279
25UNNXC-25NXC-25/N1NA+1NC5.5kW710010100000280
32UNNXC-32NXC-32/N1NA+1NC7.5kW710010100000281
40UNNXC-40NXC-40/N1NA+1NC11kW710010100000282
50UNNXC-50NXC-50/N1NA+1NC15kW710010100000283
65UNNXC-65NXC-65/N1NA+1NC30kW710010100000284
80UNNXC-80NXC-80/N1NA+1NC37kW710010100000285
95UNNXC-95NXC-95/N1NA+1NC45kW710010100000286
100UNNXC-100NXC-100/N2NO+2NC55kW710010100000287
120UNNXC-120NXC-120/N2NO+2NC75kW710010100000288
160UNNXC-160NXC-160/N2NO+2NC90kW710010100000289
200UNNXC-200NXC-200/N2NO+2NC110kW710010100000290
250UNNXC-250NXC-250/N2NO+2NC132kW710010100000291
315UNNXC-315NXC-315/N2NO+2NC160kW710010100000292
400UNNXC-400NXC-400/N2NO+2NC200kW710010100000293
500UNNXC-500NXC-500/N2NO+2NC250kW710010100000294
630UNNXC-630ANXC-630A/N2NO+2NC315kW710010100000295
  1. NC5 High-performance Series

Model Rule

NC5-[Attuale][Tipo][Tensione della bobina]

– Tipo: Standard / E=Economy / NE=Intelligent / F=Reversing

Intervallo correnteStandardIntelligenteReversingAux. ContattoTensione di isolamento
9A~38ANC5-09~38NC5NE-09~38NC5F-09~381NA+1NC690V
40A~100ANC5-40~100NC5NE-40~100NC5F-40~1001NA+1NC690V
115A~250ANC5-115~250NC5NE-115~250NC5F-115~2502NO+2NC1000V
315A~630ANC5-315~630NC5NE-315~630NC5F-315~6302NO+2NC1000V
  1. Classic CJX2 Series
AttualeModelloAux. ContattoMatched Motor
9UNCJX2-0910 / 0901 / 09111NO / 1NC / 1NA+1NC1.5kW
12UNCJX2-1210 / 1201 / 12111NO / 1NC / 1NA+1NC2.2kW
18UNCJX2-1810 / 1801 / 18111NO / 1NC / 1NA+1NC3kW
25UNCJX2-2510 / 2501 / 25111NO / 1NC / 1NA+1NC5.5kW
32UNCJX2-3210 / 3201 / 32111NO / 1NC / 1NA+1NC7.5kW
40UNCJX2-4010 / 4001 / 40111NO / 1NC / 1NA+1NC11kW
50UNCJX2-5010 / 5001 / 50111NO / 1NC / 1NA+1NC15kW
65UNCJX2-6510 / 6501 / 65111NO / 1NC / 1NA+1NC30kW
80UNCJX2-8010 / 8001 / 80111NO / 1NC / 1NA+1NC37kW
95UNCJX2-9510 / 9501 / 95111NO / 1NC / 1NA+1NC45kW
  1. Other Special Series

NXCF Slim Series

AttualeModelloLarghezzaAux. Contatto
9UNNXCF-0922.5mm1NA+1NC
12UNNXCF-1222.5mm1NA+1NC
16UNNXCF-1622.5mm1NA+1NC
25UNNXCF-2536mm1NA+1NC
32UNNXCF-3236mm1NA+1NC

NC8 Heavy-duty Series

AttualeModelloPoliVita meccanica
9A~38ANC8-09~383P10 milioni di cicli
40A~100ANC8-40~1003P10 milioni di cicli
115A~500ANC8-115~5003P/4P8 milioni di cicli

NXCC Capacitor Contactor

AttualeModelloSuppression TypeCapacitor Rating
16UNNXCC-16Series resistor10kvar
25UNNXCC-25Series resistor15kvar
32UNNXCC-32Series resistor20kvar
40UNNXCC-40Series resistor25kvar
50UNNXCC-50Series resistor30kvar
63UNNXCC-63Series resistor40kvar
80UNNXCC-80Series resistor50kvar
100UNNXCC-100Series resistor60kvar

NCH8 Building / Contattore domestico

ModelloPoliAttualeApplicazione
NCH8-16M2P16UNSmart home control
NCH8-25M2P25UNAir conditioning control
NCH8-32M2P32UNSmall water pump
NCH8-40M2P40UNFloor heating system
NCH8-63M2P63UNBuilding lighting
  1. Universal Accessories
AccessorioModelloSerie applicabile
Auxiliary Contact BlockAX-3M SeriesNXC / NC5 / CJX2
Time Delay ModuleF5 SeriesFull series
Coil Surge SuppressorSR2 SeriesFull series
Interblocco meccanicoNXC-IL / NC5-ILReversing contactor
Relè di sovraccarico termicoNR2 / NR5 SeriesMotor protection combination
35Guida DIN da mmTipo standardFull cabinet-mounted contactors
  1. Selezione & Guida alla sostituzione
  2. Series Selection

New project: Adopt NXC KunLun series as priority.

Intelligent control: Choose NC5NE intelligent contactor.

Compact cabinet: Use ultra-thin NXCF.

Compensazione della potenza reattiva: Special NXCC capacitor contactor.

  1. Current Selection

Rated current ≥ motor rated current × 1.1 (normal duty).

Frequent operation ≥ motor current × 1.25.

  1. Tensione della bobina

Match control circuit voltage: AC220V / AC380V most common; safety low-voltage 24V/36V optional.

  1. Contatti ausiliari

Expandable via external auxiliary blocks when signal points are insufficient.

Reversing circuit must adopt mechanical interlock type.