| Segmento modello | Descrizione |
| NXC | Codice serie prodotto: Contattore CA serie CHINT KunLun, upgraded replacement for traditional CJX2 series |
| 65 | Corrente operativa nominale: 65UN (under AC-3, 400V) |
| UN | Configuration code: Tipo standard (no suffix = standard; suffix /N = reversing type) |
| Common Suffix | Codice tensione bobina: 220V / 380V / 110V / 24V, per esempio. NXC-65 220V |
Full Model Example:
NXC-65 220V 50Hz = CHINT KunLun 65A AC contactor, tensione bobina 220V, 50Hz, configurazione standard
Typical Order No.: 710010100000281 (NXC-65 220 V 50 Hz, 1NA+1NC)
- Main Technical Data
| Categoria | Specifiche | Osservazioni |
| Informazioni di base | ||
| Marca / Serie | CHINT Electric / KunLun NXC Series | Struttura compatta, direct replacement for CJX2-65 |
| Tipo di prodotto | 3-phase AC Contactor | For frequent motor starting & remote circuit switching |
| Standard di conformità | GB/T 14048.1 / CEI 60947-1, GB/T 14048.4 / CEI 60947-4-1 | International certified, sicuro e affidabile |
| Dati elettrici | ||
| Corrente operativa nominale (Cioè) | 65UN (AC-3, 400V) | Main contact rated current |
| Tensione operativa nominale (Ue) | 380V / 400V (50Hz) | Standard industrial grid voltage |
| Tensione di isolamento nominale (Ui) | 690V | Max withstand voltage of insulation system |
| Tensione nominale di resistenza all'impulso (Ump) | 8kV | Overvoltage protection capability |
| Tensione della bobina di controllo | Optional AC 24V / 36V / 110V / 220V / 380V | Selected according to control system |
| Frequenza della bobina | 50 / 60Hz | Compatibilità con la rete globale |
| Frequenza operativa nominale | 1200 cycles/h (AC-3) | High frequent operation capability |
| Capacità di interruzione | 10× rated current | Short-circuit withstand capability |
| Configurazione dei contatti | ||
| Contatti principali | 3NO (3-polo normalmente aperto) | Standard for main power circuit |
| Contatti ausiliari | 1NO + 1NC | Expandable on request |
| Auxiliary Contact Rating | 5UN / 220V e | For control signal circuits |
| Caratteristiche fisiche | ||
| Dimensioni (L×A×P) | 90mm × 150mm × 105mm | Compatto, salvaspazio |
| Peso | ca. 0.8kg | Lightweight for easy installation |
| Montaggio | Guida DIN standard da 35 mm / montaggio a vite | Snap-on design, fast assembly |
| Classe di protezione | IP20 | Suitable for cabinet installation |
| Temperatura operativa | -30℃ ~ +60 ℃ | Wide temperature range for harsh environments |
| Temperatura di conservazione | -25℃ ~ +40 ℃ | Suitable for transportation & warehouse storage |
| Electromagnetic Performance | ||
| Potenza della bobina | ca. 180VA (pick-up) / 25VA (presa) | Basso consumo energetico, energy-saving |
| Drop-out Voltage | 30% ~ 70% della tensione nominale | Reliable disconnection |
| Electromagnetic System | Optimized silicon steel lamination (32-piece core) | Smooth closure, basso rumore & loss |
| Caratteristiche di sicurezza | ||
| Certificazioni | CE, CCC | Domestico & international compliance |
| Arc Extinction | Multi-channel magnetic blow-out arc suppression | High breaking performance |
| Funzioni di protezione | Sovracorrente, surriscaldamento, undervoltage protection | Comprehensive equipment & circuit protection |
- Accessory List
| Accessorio | Modello | Funzione | Posizione di montaggio |
| Auxiliary Contact Block | AX-3M/20 (2NO), AX-3M/02 (2NC), AX-3M/11 (1NA+1NC) | Expand auxiliary contacts for complex logic | Top front |
| Time Delay Module | F5-08 (0.1~30s), F5-11 (0.1~180s) | In ritardo / off-delay control | Top |
| Soppressore di sovratensioni | SR2-220, SR2-380 | Suppress coil surge voltage | Bottom |
| Interblocco meccanico | NXC-IL | Prevent phase short circuit for reversing contactor (NXC-65/N) | Side |
| Mounting Rail | 35Guida DIN standard da mm | Installazione fissa | Inside control cabinet |
| Terminal Protection Cover | Standard equipped | Anti-touch protection | Principale & auxiliary terminals |
| Mounting Screws | M4×12mm | Fissaggio a vite | Base mounting holes |
| Operation Manual | Elettronico / hard copy | Installazione, commissioning & maintenance guide | — |
| Coil Connector | Opzionale | Fast coil wiring & sostituzione | Coil terminal side |
- Cross-Brand Equivalent & Sostituzione
| Marca | Serie | Modello | Corrente nominale | Differenze | Compatibilità di sostituzione |
| CINT | CJX2 | CJX2-6511 | 65UN | Old generation; NXC is fully upgraded version | Direct full replacement (same mounting size) |
| Schneider | TeSys D | LC1D65M7C | 65UN | Import brand, costo più elevato, funzioni simili | Alto (verify mounting & contatti ausiliari) |
| Siemens | 3RT | 3RT2026-1BB40 | 65UN | Progettazione modulare, hot-swap support | Medio (different dimension & cablaggio) |
| ABB | DI | AF65-30-11 | 65UN | Wide-voltage coil, global application | Medio (needs position adjustment) |
| Mitsubishi | S-N | S-N65 | 65UN | Compact Japanese design, prezzo moderato | Medio (different terminal layout) |
| Changshu | CK3 | CK3-65 | 65UN | Domestic equivalent, same performance | Alto (fully compatible size & mounting) |
- Funzioni principali & Applicazioni
Funzioni principali
- High-efficiency Electromagnetic System: Optimized core structure for stable closure, low noise and low energy consumption.
- Highly Reliable Arc Suppression: Magnetic blow-out technology with 10× rated breaking capacity for higher safety.
- Espansione flessibile: Supports auxiliary contacts, timer modules and surge suppressors for customized control.
- Installazione semplice: Snap-on DIN rail mounting for fast assembly and maintenance.
- Wide Temperature Adaptation: Stable operation from -30℃ to +60℃ for various industrial environments.
Applicazioni tipiche
- Controllo motorio: Frequent start/stop/reverse of 3-phase asynchronous motors (ca. 30kW@400V).
- Automazione industriale: Production lines, trasportatori, tifosi, water pumps and general machinery.
- Building Electrical: Sistemi HVAC, fire water pumps, elevator auxiliary circuits.
- Macchine utensili: Spindle control for milling machines, drilling machines and small machining centers.
- Distribuzione dell'energia: Combinato con relè termici (Serie NR2) for complete motor protection starters.
- Note supplementari
- Product Upgrade: The NXC KunLun series fully replaces the traditional CJX2 series with improved mechanical structure, electromagnetic performance and expandability.
- Linee guida per la selezione:
Select current rating according to motor power (65A matches approx. 30kW motor).
Confirm coil voltage (220V / 380V most common).
Expand auxiliary contacts via AX series modules if signal points are insufficient.
- Suggerimenti per la manutenzione:
Regularly check contact wear; replace contacts when excessive contact resistance occurs.
Keep the contactor clean from dust and moisture.
Apply periodic energization (1–2 times monthly) for long-term idle equipment to prevent coil dampness.
CHINT Contactor Full Series List
- Product Series Overview
| Serie | Posizionamento | Intervallo corrente | Caratteristiche | Replacement Relation |
| NXC | KunLun Main Series | 6A ~ 630A | Compatto, modular, high cost-performance | Full replacement for CJX2 |
| NC5 | High-performance Intelligent Series | 9A ~ 630A | Smart control, energy-saving, high stability | High-end alternative to NXC |
| CJX2 | Classic Traditional Series | 9A ~ 95A | Mature model, conveniente | Gradually phased out by NXC |
| NXCF | Slim Compact Series | 9A ~ 32A | Ultra-thin, salvaspazio | Small cabinet & compact installation |
| NC8 | Heavy-duty Industrial Series | 9A ~ 500A | High mechanical life, strong arc resistance | Frequent start-stop working conditions |
| NXCC | Capacitor Switching Contactor | 16A ~ 100A | Inrush current suppression, reactive power compensation dedicated | Capacitor bank control |
| NCH8 | Household & Building Series | 16A ~ 63A | Miniature size, building automation | Illuminazione, HVAC & residential control |
| CJ40 / CJ20 | High-power Heavy Series | 100A ~ 630A | Heavy-load design for large motors | Heavy industrial equipment |
- NXC KunLun Series Main Model List (AC-3 400V)
| Corrente nominale | Modello standard | Reversing Model | Standard Aux. Contatto | Matched Motor Power | Ordine n. |
| 6UN | NXC-06M | — | 1NA+1NC | 0.75kW | 710010100000276 |
| 9UN | NXC-09 | NXC-09/N | 1NA+1NC | 1.5kW | 710010100000277 |
| 12UN | NXC-12 | NXC-12/N | 1NA+1NC | 2.2kW | 710010100000278 |
| 18UN | NXC-18 | NXC-18/N | 1NA+1NC | 3kW | 710010100000279 |
| 25UN | NXC-25 | NXC-25/N | 1NA+1NC | 5.5kW | 710010100000280 |
| 32UN | NXC-32 | NXC-32/N | 1NA+1NC | 7.5kW | 710010100000281 |
| 40UN | NXC-40 | NXC-40/N | 1NA+1NC | 11kW | 710010100000282 |
| 50UN | NXC-50 | NXC-50/N | 1NA+1NC | 15kW | 710010100000283 |
| 65UN | NXC-65 | NXC-65/N | 1NA+1NC | 30kW | 710010100000284 |
| 80UN | NXC-80 | NXC-80/N | 1NA+1NC | 37kW | 710010100000285 |
| 95UN | NXC-95 | NXC-95/N | 1NA+1NC | 45kW | 710010100000286 |
| 100UN | NXC-100 | NXC-100/N | 2NO+2NC | 55kW | 710010100000287 |
| 120UN | NXC-120 | NXC-120/N | 2NO+2NC | 75kW | 710010100000288 |
| 160UN | NXC-160 | NXC-160/N | 2NO+2NC | 90kW | 710010100000289 |
| 200UN | NXC-200 | NXC-200/N | 2NO+2NC | 110kW | 710010100000290 |
| 250UN | NXC-250 | NXC-250/N | 2NO+2NC | 132kW | 710010100000291 |
| 315UN | NXC-315 | NXC-315/N | 2NO+2NC | 160kW | 710010100000292 |
| 400UN | NXC-400 | NXC-400/N | 2NO+2NC | 200kW | 710010100000293 |
| 500UN | NXC-500 | NXC-500/N | 2NO+2NC | 250kW | 710010100000294 |
| 630UN | NXC-630A | NXC-630A/N | 2NO+2NC | 315kW | 710010100000295 |
- NC5 High-performance Series
Model Rule
NC5-[Attuale][Tipo][Tensione della bobina]
– Tipo: Standard / E=Economy / NE=Intelligent / F=Reversing
| Intervallo corrente | Standard | Intelligente | Reversing | Aux. Contatto | Tensione di isolamento |
| 9A~38A | NC5-09~38 | NC5NE-09~38 | NC5F-09~38 | 1NA+1NC | 690V |
| 40A~100A | NC5-40~100 | NC5NE-40~100 | NC5F-40~100 | 1NA+1NC | 690V |
| 115A~250A | NC5-115~250 | NC5NE-115~250 | NC5F-115~250 | 2NO+2NC | 1000V |
| 315A~630A | NC5-315~630 | NC5NE-315~630 | NC5F-315~630 | 2NO+2NC | 1000V |
- Classic CJX2 Series
| Attuale | Modello | Aux. Contatto | Matched Motor |
| 9UN | CJX2-0910 / 0901 / 0911 | 1NO / 1NC / 1NA+1NC | 1.5kW |
| 12UN | CJX2-1210 / 1201 / 1211 | 1NO / 1NC / 1NA+1NC | 2.2kW |
| 18UN | CJX2-1810 / 1801 / 1811 | 1NO / 1NC / 1NA+1NC | 3kW |
| 25UN | CJX2-2510 / 2501 / 2511 | 1NO / 1NC / 1NA+1NC | 5.5kW |
| 32UN | CJX2-3210 / 3201 / 3211 | 1NO / 1NC / 1NA+1NC | 7.5kW |
| 40UN | CJX2-4010 / 4001 / 4011 | 1NO / 1NC / 1NA+1NC | 11kW |
| 50UN | CJX2-5010 / 5001 / 5011 | 1NO / 1NC / 1NA+1NC | 15kW |
| 65UN | CJX2-6510 / 6501 / 6511 | 1NO / 1NC / 1NA+1NC | 30kW |
| 80UN | CJX2-8010 / 8001 / 8011 | 1NO / 1NC / 1NA+1NC | 37kW |
| 95UN | CJX2-9510 / 9501 / 9511 | 1NO / 1NC / 1NA+1NC | 45kW |
- Other Special Series
NXCF Slim Series
| Attuale | Modello | Larghezza | Aux. Contatto |
| 9UN | NXCF-09 | 22.5mm | 1NA+1NC |
| 12UN | NXCF-12 | 22.5mm | 1NA+1NC |
| 16UN | NXCF-16 | 22.5mm | 1NA+1NC |
| 25UN | NXCF-25 | 36mm | 1NA+1NC |
| 32UN | NXCF-32 | 36mm | 1NA+1NC |
NC8 Heavy-duty Series
| Attuale | Modello | Poli | Vita meccanica |
| 9A~38A | NC8-09~38 | 3P | 10 milioni di cicli |
| 40A~100A | NC8-40~100 | 3P | 10 milioni di cicli |
| 115A~500A | NC8-115~500 | 3P/4P | 8 milioni di cicli |
NXCC Capacitor Contactor
| Attuale | Modello | Suppression Type | Capacitor Rating |
| 16UN | NXCC-16 | Series resistor | 10kvar |
| 25UN | NXCC-25 | Series resistor | 15kvar |
| 32UN | NXCC-32 | Series resistor | 20kvar |
| 40UN | NXCC-40 | Series resistor | 25kvar |
| 50UN | NXCC-50 | Series resistor | 30kvar |
| 63UN | NXCC-63 | Series resistor | 40kvar |
| 80UN | NXCC-80 | Series resistor | 50kvar |
| 100UN | NXCC-100 | Series resistor | 60kvar |
NCH8 Building / Contattore domestico
| Modello | Poli | Attuale | Applicazione |
| NCH8-16M | 2P | 16UN | Smart home control |
| NCH8-25M | 2P | 25UN | Air conditioning control |
| NCH8-32M | 2P | 32UN | Small water pump |
| NCH8-40M | 2P | 40UN | Floor heating system |
| NCH8-63M | 2P | 63UN | Building lighting |
- Universal Accessories
| Accessorio | Modello | Serie applicabile |
| Auxiliary Contact Block | AX-3M Series | NXC / NC5 / CJX2 |
| Time Delay Module | F5 Series | Full series |
| Coil Surge Suppressor | SR2 Series | Full series |
| Interblocco meccanico | NXC-IL / NC5-IL | Reversing contactor |
| Relè di sovraccarico termico | NR2 / NR5 Series | Motor protection combination |
| 35Guida DIN da mm | Tipo standard | Full cabinet-mounted contactors |
- Selezione & Guida alla sostituzione
- Series Selection
New project: Adopt NXC KunLun series as priority.
Intelligent control: Choose NC5NE intelligent contactor.
Compact cabinet: Use ultra-thin NXCF.
Compensazione della potenza reattiva: Special NXCC capacitor contactor.
- Current Selection
Rated current ≥ motor rated current × 1.1 (normal duty).
Frequent operation ≥ motor current × 1.25.
- Tensione della bobina
Match control circuit voltage: AC220V / AC380V most common; safety low-voltage 24V/36V optional.
- Contatti ausiliari
Expandable via external auxiliary blocks when signal points are insufficient.
Reversing circuit must adopt mechanical interlock type.
Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari








![NXC-65 della serie Kunlun di CHINT Electric è un contattore CA a 3 poli, valutato a 65 A nella serie NXC. Il modello completo è tipicamente espresso come NXC-65 [Tensione della bobina] [Frequenza] NXC-65 from the Kunlun Series by CHINT Electric is a 3-pole AC contactor, rated at 65A in the NXC series. The full model is typically expressed as NXC-65 [Coil Voltage] [Frequency]](https://www.bestcontactor.com/wp-content/uploads/2026/04/ScreenShot_2026-01-30_132315_324-419x560.png)









NH42-63-318x560.png)