NXC-185-380V (Ordine n.: 710010100000343) Segment Meaning Description NXC Product Series CHINT Kunlun series AC contactor, upgraded compact structure replacing traditional CJX2 series 185 Rated Current Rated operational current of main contact: 185UN (AC-3, 400V) 380V Coil Voltage Rated control coil voltage: AC380V, standard frequency 50Hz Supplementary Specifications: 3-palo (3P), 3 normally-open main contacts, 2NO+2NC auxiliary ...

  • Dettagli del prodotto

NXC-185-380V (Ordine n.: 710010100000343)

SegmentoSensoDescrizione
NXCSerie di prodottiCHINT Kunlun series AC contactor, upgraded compact structure replacing traditional CJX2 series
185Corrente nominaleRated operational current of main contact: 185UN (AC-3, 400V)
380VTensione della bobinaRated control coil voltage: AC380V, standard frequency 50Hz

Supplementary Specifications: 3-palo (3P), 3 normally-open main contacts, 2Contatti ausiliari NA+2NC, standard mounting type

  1. Parametri delle specifiche principali
CategoriaDati tecniciOsservazioni
Basic Properties
Tipo di prodottoElectromagnetic AC ContactorSerie Kunlun, replacement for CJX2-1850
Standard applicabiliGB/T 14048.4 / CEI 60947-4-1Compliant with GB 21518 safety standard
Tensione di isolamento nominale1000VUnified standard for specifications above 120A
Tensione operativa nominale220V~690VCompatible with various industrial power supply systems
Parametri Elettrici
Corrente operativa nominale (Cioè)185UN (AC-3, 400V)Matches motor power around 90kW
Capacità di produzione nominale10×Ie (AC-3)1850UN, reliable load switching
Capacità di interruzione nominale8×Ie (AC-3)1480UN, safe fault current interruption
Parametri della bobinaAC380V, 50Hz, power approx. 170VAPick-up/holding power ratio about 3:1
Contatti ausiliari2NO+2NC, rated current 5ASignal transmission for control circuits
Parametri meccanici
Numero di poli3P (3 NESSUN contatto principale)Configurazione standard, 4P version optional
Metodo di montaggioGuida DIN standard da 35 mm / montaggio a viteFits mainstream control cabinets
Materiale dell'alloggiamentoFlame-retardant engineering plasticUL94 V0 flame resistance grade
Grado di protezioneIP20Finger-touch safe, indoor cabinet installation only
Vita meccanica10,000,000 operazioniLunga durata, low maintenance frequency
Vita elettrica1,000,000 operazioni (AC-3)Adatto per frequenti operazioni di avvio-arresto
Parametri Ambientali
Temperatura operativa-30°C~+70°CWide temperature range for harsh industrial conditions
Temperatura di conservazione-40°C~+85°CMeets storage and transportation requirements
Umidità relativa5%~95%, senza condensaAdaptable to humid working environment
Altitudine≤2000mDerating required for higher altitude
  1. Cross-brand Replacement Comparison
MarcaModelloCaratteristiche similiDifferenze
CINTNXC-185-380VReference modelSerie Kunlun, conveniente, preferred domestic replacement
SchneiderLC1D18500Q7185UN, 3P, 380Bobina VPrezzo più alto, 1Contatti ausiliari NA+1NC
ABBA185-30-11185UN, 3P, 380Bobina V1Contatti ausiliari NA+1NC, different mounting dimensions
Siemens3RT2036-1AP00185UN, 3P, 380Bobina VHigh price, risposta rapida, ideal for precision control
DELIXICDM3-185185UN, 3P, 380Bobina VAlternativa domestica, similar price, slightly lower performance

Note di sostituzione:

  1. Confirm identical coil voltage, pole number and auxiliary contact configuration before replacement
  2. Verify mounting hole compatibility among different brands
  3. Check derating curve matching for high altitude and special environments
  4. Matching CHINT NXR thermal overload relay is recommended for optimal protection
  5. Elenco completo dei modelli della serie (Core NXC Models)
Modello Corrente nominale Tensione della bobina Contatto ausiliario Pole Ordine n.
NXC-06-220V 6UN AC220V 1NA+1NC 3P710010100000001
NXC-12-380V 12UN AC380V 1NA+1NC 3P710010100000002
NXC-18-220V 18UN AC220V 1NA+1NC 3P710010100000003
NXC-25-380V 25UN AC380V 1NA+1NC 3P710010100000004
NXC-32-220V 32UN AC220V 1NA+1NC 3P710010100000005
NXC-40-380V 40UN AC380V 1NA+1NC 3P710010100000006
NXC-50-220V 50UN AC220V 1NA+1NC 3P710010100000007
NXC-65-380V 65UN AC380V 1NA+1NC 3P710010100000008
NXC-80-220V 80UN AC220V 2NO+2NC 3P710010100000009
NXC-100-380V 100UN AC380V 2NO+2NC 3P710010100000305
NXC-120-220V 120UN AC220V 2NO+2NC 3P710010100000306
NXC-150-380V 150UN AC380V 2NO+2NC 3P710010100000307
NXC-185-380V 185UN AC380V 2NO+2NC 3P710010100000343
NXC-225-380V 225UN AC380V 2NO+2NC 3P710010100000344
NXC-265-380V 265UN AC380V 2NO+2NC 3P710010100000345

Model Extension Rules:

Suffisso M: Contattore reversibile (per esempio. NXC-25M-220V)

Suffix 4P: 4-contattore di polo (per esempio. NXC-65-4P-380V)

Suffix Z: Bobina CC (per esempio. NXC-18-24Z)

Auxiliary contact expansion: Max 6NO+6NC with F4-XX auxiliary contact block

  1. Difetti comuni & Risoluzione dei problemi
Fenomeno di guastoPossibili causeSoluzioni
Il contattore non si inserisce1. Abnormal coil voltage1. Verify stable 380V power supply
2. Open control circuit2. Check wiring and fuse
3. Bobina bruciata3. Test coil resistance (normal ~800Ω), replace damaged coil
4. Inceppamento meccanico4. Clean iron core and reset spring
Forte rumore dopo il pull-in1. Oil contamination on core surface1. Clean contact surface of iron core
2. Anello di cortocircuito rotto2. Replace iron core or short-circuit ring
3. Sottotensione3. Ensure voltage ≥85% rated value
Overheated / burned contacts1. Corrente di carico eccessiva1. Upgrade to higher capacity model
2. Poor contact performance2. Clean contacts and adjust contact pressure
3. Commutazione frequente3. Optimize control logic to reduce unnecessary switching
4. Failed arc suppression4. Inspect and maintain arc shield
Malfunction of auxiliary contacts1. Ossidazione da contatto1. Polish and clean contacts
2. Ablazione del contatto2. Replace auxiliary contact assembly
3. Cablaggio allentato3. Fasten terminal connections
Overheating and burnt coil1. Sovratensione1. Keep voltage within rated range
2. Excessive operation frequency2. Reduce switching frequency or adopt AC-4 type contactor
3. Temperatura ambiente elevata3. Improve ventilation condition
4. Stuck iron core4. Ensure flexible mechanical movement
  1. Conformità del trasporto aereo & Certificazioni
  2. Certificazioni

Certificazione CE, compliant with EU Machinery Directive

cULus certification complying with North American safety standards

CCC compulsory certification of China

RoHS environmental compliance

  1. Air Transport Regulations

No built-in lithium battery or super capacitor, classified as ordinary industrial electrical equipment

Merci non pericolose, conforms to IATA DGR Class 9 requisiti

Standard industrial packaging, massimo 20 units per carton to avoid collision damage

Recommended marks: FRAGILE, ELECTRICAL EQUIPMENT, KEEP DRY

  1. Ambiente applicativo & Adattamento

Scenari applicabili

Controllo motori industriali: Inizio, stop and reverse control of three-phase asynchronous motors below 90kW

Fan & Water Pump System: HVAC, industrial circulating water and sewage aeration equipment control

Compressor Control: Heavy-duty air and refrigeration compressors for AC-3 working condition

Linea di produzione automatica: Core component for sequence control and interlock protection

Building Electrical System: Aria condizionata centralizzata, fire water pump and elevator room equipment control

Mining Machinery: Remote control and protection for belt conveyors and crushers

Metallurgical Equipment: Electrical control system for small rolling mills and furnace auxiliary units

Unsuitable Scenarios

DC circuit control (Select dedicated NXC-Z series DC contactors)

High-frequency operation over 1200 cycles per hour (AC-4 contactor or solid state relay recommended)

Use above 2000m altitude without power derating

Severe vibration environment over 5g without damping measures

Corrosive gas environment without anti-corrosion protection

  1. Application Cases

Caso 1: Central Air Conditioning Control of Large Shopping Mall

Applicazione: Control of 3 sets 90kW water chillers and 4 sets 75kW cooling tower fans

Sfide: 20-30 daily start-stop cycles, high reliability and energy saving requirement

Soluzione: NXC-185-380V + NXR-185 thermal overload relay + intelligent PLC control system

Result: Trouble-free operation for 2 anni, 30% energy saving with frequency conversion, 50% maintenance cost reduction

Caso 2: Conveyor System for Auto Parts Production Line

Applicazione: 12 belt conveyor lines with 75kW driving motor each, sequential start-stop and interlock protection

Sfide: Multi-motor synchronous control, frequent forward/reverse rotation, oily environment

Soluzione: NXC-185-380V for main drive + NXC-65-380V for auxiliary drive + safety relay

Result: Precise synchronous operation, IP20 protection against oil contamination, vita meccanica fino a 8 milioni di cicli

  1. Linee guida per la selezione

Quick Rules

Corrente nominale: NXC-X ranging 6~630A, matching motor power about X/2 kW

Standard coil voltage: 220V / 380V; optional 110V / 24V / 48V

Contatto ausiliario: 1NO+1NC for ≤80A; 2NO+2NC for ≥100A

Montaggio: Universal 35mm DIN rail for mainstream cabinets

Classe di protezione: IP20, indoor cabinet use only, outdoor exposed installation prohibited

Specific Application Scenarios of NXC185-380V

  1. Controllo motorio

Inizio, stop and reverse control of three-phase asynchronous motors below 90kW

Continuous operation control of constant-load equipment including fans, pumps and compressors

Motor control with operation frequency ≤1200 cycles per hour

  1. Industrial Automation System

Sequence control and interlock protection of production line facilities

Peripheral equipment control of robot workstations

Stacker and conveyor control in automated warehouses

  1. Costruzione & Infrastrutture

Water chiller and cooling tower control for commercial central air conditioning

Fire water pump and exhaust fan control of high-rise buildings

Ventilation system control of underground parking lots

  1. Energia & Protezione ambientale

Aeration equipment and sludge pump control in sewage treatment plants

Switch control of small photovoltaic inverters and energy storage systems

Control system of waste disposal equipment

  1. Estrazione mineraria & Metallurgia

Belt conveyor and crusher control in mines

Auxiliary equipment control of small metallurgical furnaces

Electrical control system of mineral processing facilities

Restricted Application

DC circuit application

Operation frequency exceeding 1200 cycles per hour

Underrated use at altitude over 2000m

Heavy vibration environment without damping measures

Corrosive gas environment without protective treatment