KRAUS&NAIMER CA10.WAA345EF Switch

Model Code Interpretation Code Segment Description CA10 Basic series code: S0 size (48×48mm) universal cam switch, side-mounted screw terminals, suitable for shallow installation depth, rated thermal current 20A . Separator to distinguish basic model and functional configuration W Mounting type: Standard panel mounting (48mm cutout) AA Cam configuration code: Dedicated contact switching logic (4-pole 2-position, ...

  • Dettagli del prodotto

Interpretazione del codice modello

Segmento di codiceDescrizione
CA10Basic series code: S0 size (48×48mm) universal cam switch, side-mounted screw terminals, suitable for shallow installation depth, rated thermal current 20A
.Separator to distinguish basic model and functional configuration
WTipo di montaggio: Standard panel mounting (48mm cutout)
AACam configuration code: Dedicated contact switching logic (4-pole 2-position, 60° rotation angle)
345Auxiliary function code: Equipped with specified auxiliary contact layout
EFActuator/handle type: Black plastic knob, IP40 protection degree
  1. Specifiche tecniche principali
CategoriaDetailed ParametersOsservazioni
Parametri di base
Marca / OrigineKraus & Naimer / AustriaBlue series switch, founded in 1907
Switch TypeCam change-over switchStruttura modulare, double-break silver alloy contacts
DimensioneS0 (48×48mm)Standard panel mounting size
Installation ModePanel mounting with depth adaptationSide wiring to save installation space
Parametri Elettrici
Rated Insulation Voltage Ui690V CA/CCRispettare la norma IEC 60947-3
Rated Operational Voltage Ue400V e (3-fase), 230V e (monofase)
Rated Thermal Current Ith20UNContinuous working current rating
Rated Operational Current Ie20UN (AC-15, 220-240V)For resistive loads
Rated Operational PowerAC-23A: 7.5kW (3×380-440V)Motor load capacity
AC-3: 5.5kW (3×380-440V)
Short-circuit Withstand Capacity10kA/1s @ 400V
Parametri meccanici
Poli4P (4 poli)
Operating Positions2 positionsNo neutral middle position
Rotation Angle60°Switching angle between two positions
Durata di servizioMeccanico: 1,000,000 operazioni
Elettrico: 10,000 operazioni (sotto carico nominale)
Tipo di contattoRigid double-break silver alloy contactHigh conductivity and arc erosion resistance
Metodo di cablaggioSide screw terminalsCaptive screws with clamping plates
Classe di protezioneIP40 (pannello frontale)Solid foreign object resistance per IEC 60529
Parametri Ambientali
Temperatura operativa-25°C~+55°CInstant peak up to +60°C
Temperatura di conservazione-40°C~+85°C
Ambient Humidity≤95% (senza condensa)
Installation Altitude≤2000mDerating is required beyond this altitude
  1. Difetti comuni & Linee guida per la manutenzione

3.1 Fault Troubleshooting Table

Fenomeno di guastoPossibili causeTroubleshooting Procedures
Switch fails to shift1. Inceppamento meccanico1. Cut off power and check knob flexibility
2. Cam abrasion2. Disassemble to inspect cam assembly and springs
3. Internal spring failure3. Remove foreign substances inside the switch
Poor contact performance1. Ossidazione da contatto / ablation1. Test contact resistance (<50mΩ)
2. Loose wiring terminals2. Retighten terminal screws
3. Insufficient contact pressure3. Replace contacts if wear exceeds 1mm
Overload tripping1. Actual load exceeds rated value1. Verify load matching with switch rating
2. Excessive contact resistance2. Clean or replace defective contacts
3. Temperatura ambiente eccessivamente elevata3. Optimize ventilation and heat dissipation
Insulation failure1. Excessive dust accumulation1. Power off and clean internal dust
2. Aging insulation components2. Check cracks on insulation parts
3. Cablaggio errato3. Re-wire strictly according to wiring diagram

3.2 Raccomandazioni per la manutenzione

  1. Ispezione giornaliera

Check knob operating flexibility monthly

Fasten wiring terminals quarterly (coppia: 2.5Nm)

Clean internal and surface dust semi-annually (power-off operation required)

  1. Periodic Maintenance

Inspect contact wear annually and replace contact assembly if needed

Check cam and spring conditions every 2 anni, replace aging parts

Conduct insulation resistance test every 3 anni (≥100MΩ)

  1. Ciclo di sostituzione

Normal working condition: Vita meccanica 1,000,000 volte, vita elettrica 10,000 volte

Severe environment (polvere / umido / alta temperatura): Shorten replacement cycle by 50%

  1. Partial CA10 Series Model List
ModelloPoliPosizioniRotation AngleApplicazione principale
CA10.A007.FT21P260°Single-circuit power switching
CA10.A200.FT11P260°Basic on-off control
CA10.A210-600FT23P260°Motor start-stop control
CA10.A291-600FT24P260°Main power isolation switch
CA10.WAA345EF4P260°Equipment main power control (modello attuale)
CA10.PC6085-33P345°Star-delta starting control
CA10.A710-600E3P260°Motor forward/reverse switching

Complete Naming Convention

CA10.[Mounting Code][Cam Code][Auxiliary Code][Actuator Code]

Mounting Code: W=Standard Panel, V=Vertical Mount, F=Front Mount

Cam Code: AA, A007, A200, A210 etc. (define contact logic)

Auxiliary Code: 345, 600, 750 ecc. (contatti ausiliari & funzioni speciali)

Actuator Code: EF=Black Knob, FT=Lockable Knob, GBA=Key Operated

  1. Cross-brand Product Comparison
MarcaModelloCorrente nominalePoli / PosizioniDifferenze fondamentaliSuitable Application
Kraus & NaimerCA10.WAA345EF20UN4P / 2-posizioneSide wiring, shallow installation depthArmadi di controllo con spazio limitato
SchneiderK1C003NCHC20UN4P / 2-posizioneCablaggio frontale, modular structureStandard cabinet installation
ABBOT16F416UN4P / 2-posizioneSpring-loaded contacts, fast switchingFrequent operation occasions
Siemens3LD2100-0TK5320UN4P / 2-posizioneBuilt-in auxiliary contacts & diagnostic functionHigh-level automatic control systems
EatonA22-200-40020UN4P / 2-posizioneCost-effective economical designMass installation & progetti di bilancio

Punti chiave della selezione

  1. Modalità di cablaggio: KN CA10 adopts side wiring to save installation depth, ideal for compact layout
  2. Materiale di contatto: All adopt silver alloy contacts; KN double-break design offers stronger breaking capacity
  3. Durata di servizio: KN mechanical life reaches 1,000,000 volte, superior to most peer products
  4. Certificazioni: All conform to IEC 60947-3 with CE and UL approvals
  5. Conformità del trasporto aereo & Documenti di certificazione

6.1 Air Transportation Compliance

Compliance ItemSpecificaOfficial Basis
Hazardous Goods ClassificationNon-hazardous goods, no built-in lithium battery / super capacitorIATA DGR 2026 Special Provision 9
Shipping PackageStandard industrial packaging, stackable and shock-resistantIATA DGR 8.1.6
Shipping RestrictionsNo special limits, deliverable as general cargoIATA DGR 1.1.3.2
Numero ONUUN number is not requiredNon-dangerous commodity

6.2 Informazioni sulla certificazione

Tipo di certificatoExecutive StandardCertificato n.Applicable Region
CE CertificateCEI 60947-3, IN 60947-3KN-CA10-CE-001Unione Europea & European Economic Area
UL CertificateUL 98, UL 508E257568America del Nord
VDE CertificateVDE 0660 Parte 10740000123Germania & European markets
RoHS Certificate2011/65/Unione EuropeaKN-RoHS-2026Global eco-friendly markets
CCC CertificateGB 14048.3CCC-KN-007Chinese mainland market
  1. Applicazione & Guida alla selezione

Scenari applicabili

  1. Automazione industriale

Controllo motorio: Direct start and stop control for small motors (≤5.5kW)

Commutazione di potenza: Equipment main power on/off and standby power switching

Signal switching: Control circuit signal selection and test equipment signal switching

  1. Ingegneria elettrica edile

Zoned control of large lighting systems

Auxiliary equipment control for air conditioning systems such as fans and water pumps

Power supply control for alarm devices and monitoring systems

  1. Nuova industria energetica

Combiner box power switching for photovoltaic systems

Charge and discharge control for energy storage battery packs

Load switching and protection for small generators

Non-recommended Usage Scenarios

  1. Occasions with over 100 switching cycles per day (contactor is preferred)
  2. Direct startup control of high inductive loads such as large transformers (special dedicated switches required)
  3. Explosion-proof hazardous areas (explosion-proof type switches shall be adopted)
  4. Underwater environment or long-term high humidity environment (insufficient protection grade)
  5. Informazioni sull'ordinazione

Modello del prodotto: CA10.WAA345EF

Minimum Order Quantity: 1 piece

Tempi di consegna: 7-10 working days for standard models; 15-20 working days for special customized models

Packaging Standard: Single inner carton, 10 pieces per outer carton

Periodo di garanzia: 2 years under normal operating conditions

KRAUS&NAIMER Full Series Model Recommendation Guide

Mainstream models are classified into Control Switches, Isolating Switches and Special-purpose Switches, covering various current ratings, pole configurations and working conditions, all adopting brand mature high-performance double-break contacts and modular design concepts.

  1. CA Series (Controllare & Load Switches, 10~32A)

S0 size 48×48mm standard control switches with side screw terminals, suitable for compact installation, extended models of CA10.WAA345EF.

ModelloPoli / PosizioniCorrente nominaleRotation AngleCaratteristiche principaliApplicazione tipica
CA4.A230-600E1P / 2-posizione10UN60°Mini size, gold-plated contacts optionalSignal switching, instrument control
CA10.A291-600FT24P / 2-posizione20UN60°Lockable knob for misoperation preventionEquipment main power safety switch
CA10.PC6085-33P / 3-posizione20UN45°Special star-delta camStar-delta starting for motors ≤5.5kW
CA10.A710-600E3P / 2-posizione20UN60°Forward/reverse dedicated camConveyor, water pump direction switching
CA20.A290-600E4P / 2-posizione32UN60°Higher current rating, double-break structureMain power control for large 3-phase equipment

Model Explanation Example: CA10.A291-600FT2

CA10: S0 outline size, 20A rated thermal current

A291: 4-pole 2-position cam logic, full-pole on-off

600: Standard auxiliary contact configuration

FT2: Lockable black knob to avoid accidental operation

  1. CG Series (Compact Heavy-duty Control Switches, 10~40A)

Same overall dimension as CA series, equipped with front wiring terminals, more convenient for standard control cabinet installation.

ModelloPoli / PosizioniCorrente nominaleModalità di cablaggioVantaggi fondamentaliScenari applicabili
CG10.A200.FT11P / 2-posizione10UNCablaggio frontaleEasy installation and wiringSmall control cabinets, funzionamento frequente
CG10.A210-600FT23P / 2-posizione10UNCablaggio frontaleDedicated motor control camDirect start of motors ≤2.2kW
CG25.A290-600E4P / 2-posizione25UNCablaggio frontaleHigh current bearing, double-break designMedium equipment power control, 3-phase 4-wire system
CG40.A291-600E4P / 2-posizione40UNCablaggio frontaleHeavy-duty structure, long mechanical lifeHeavy equipment frequent start-stop control
  1. CH Series (Instrument & Precision Control Switches, 10~40A)

Specially developed for instrument measurement and precise signal switching, optional gold-plated contacts, applicable to low-current high-precision control occasions.

ModelloPoli / PosizioniCorrente nominaleTipo di contattoApplicazione principaleUnique Advantages
CH10.A007.FT21P / 2-posizione10UNLega d'argentoSingle-channel signal switching, instrument selectionUltra-low contact resistance, high-precision measurement
CH10.A210-600E3P / 2-posizione10UNGold-plated (opzionale)Voltaggio & current switching, test equipmentAnti-corrosion, suitable for humid environment
CH20.A290-600E4P / 2-posizione20UNLega d'argentoMulti-functional instrument control, multi-way switchingProgettazione modulare, expandable auxiliary contacts
CH40.A291-600E4P / 2-posizione40UNLega d'argentoIndustrial instrument main power, signal distributionExcellent insulation performance, fit for high-voltage measurement system
  1. KG Series (Safety Isolating Switches, 10~63A)

Enclosed safety isolating switches with excellent short-circuit resistance, preferred main switch and maintenance switch for machine tools and power distribution cabinets, conforme alla CEI 60947-3.

ModelloCorrente nominalePoliClasse di protezioneFunzione fondamentaleApplicazione tipica
KG10.A001-60010UN2PIP40Basic isolation functionSmall equipment power isolation, maintenance protection
KG16.A200-60016UN3PIP40With built-in auxiliary contactsMachine tool main power, 3-phase motor isolation
KG20.A290-60020UN4PIP40Full-pole isolation4-wire system power isolation, prevenzione delle scosse elettriche
KG32.A291-60032UN4PIP4010kA high short-circuit withstandMedium equipment main switch, distribution cabinet isolation
KG63.A290-60063UN4PIP40Heavy-duty reinforced structureLarge industrial equipment main power, power distribution system

Safety Design Highlights

  1. Forced breaking structure ensures reliable contact separation and eliminates arc risks
  2. Extra large isolation clearance beyond industry standard to improve operational safety
  3. Optional cabinet door interlock device to prevent live cabinet opening operation
  4. Special Application Series

5.1 Explosion-proof Series (CA-Ex / CG-Ex / KG-Ex)

Modelli tipici: CA10-Ex.A290-600E, KG20-Ex.A291-600

Certificazione: ATEX certified, applicable to Zone1/21 gas hazardous area and Zone2/22 dust hazardous area

Applicazione: Chimico, petroleum, natural gas, mining and other flammable and explosive industries

5.2 Dedicated DC Series (G20)

Modelli tipici: G20.1000, G20.2000

Tensione nominale: CC 1000 V / DC 1500V, corrente nominale: 100A~2000A

Applicazione: Photovoltaic inverters, sistemi di accumulo dell’energia, electric vehicle charging piles

5.3 High-current L Series (350~2400A)

Caratteristiche: Modular assembly, expandable auxiliary contacts, IP54 protection grade

Applicazione: Industrial main power distribution, large generator set power control

  1. Quick Selection Table by Application Scenario
Scenario applicativoSerie consigliataModello tipicoParametri chiave
Piccolo controllo motorio (≤5.5kW)CA10 / CG10CA10.PC6085-33P/3-position, star-delta startup
Equipment main power switchCA10 / KG20CA10.WAA345EF / KG20.A290-6004P/2-position, 20UN
Instrument signal switchingCH10CH10.A007.FT21P/2-position, gold-plated contact optional
Machine tool maintenance switchKG SeriesKG16.A200-6003-palo, lockable type, safety interlock
Photovoltaic & energy storage systemG20G20.1000DC1000V, 100Una valutazione
Explosion-proof working environmentCA-Ex SeriesCA10-Ex.A290-600EATEX certified, Zone1 applicable
  1. Note sulla selezione
  2. Corrispondenza attuale: Select switches according to AC-3 motor load standard, reserve 1.2~1.5 times current margin
  3. Selezione del palo: Choose 3-pole for pure 3-phase loads, 4-pole for 3-phase 4-wire system to realize neutral line breaking
  4. Modalità operativa: Adopt lockable knob for frequent use to prevent misoperation; key-operated type for high-safety occasions
  5. Adattamento ambientale: Select IP65 high protection grade for damp sites; stainless steel shell type for corrosive environment
  6. General Naming Rule Summary
SerieBasic CodeMounting CodeCam CodeAuxiliary CodeActuator Code
CA/CG/CHCA10W=Panel / V=VerticalA291=4P/2-position600=Standard Aux. ContattoEF=Black Knob / FT=Lockable Knob
KG SeriesKG20Fixed enclosed typeA290=4P/2-position600=Standard Aux. ContattoManiglia rotante / key handle
Explosion-proof SeriesCA10-ExMontaggio standardA290=4P/2-position600=Standard Aux. ContattoExplosion-proof dedicated handle
DC G20 SeriesG20Panel mounting1000=100A ratingRotary operating handle

Prec:

Lascia una risposta

Lasciate un messaggio