All three models are PILZ PNOZ X2 compact basic safety relays, belonging to PILZ classic X series. They are designed for safety circuit monitoring of industrial equipment, mainly overseeing safety components such as emergency stop buttons, safety gates, safety light curtains and two-hand control units. The three products feature identical contact configuration, functions and dimensions, differing only in supply voltage. Equipped with standard automatic reset and dual-channel safety design, they comply with machinery safety standards Cat.3 / PL d / SIL 2.
- Spiegazione del codice modello
1.1 General Rules for Brand & Serie
PILZ: Marca (a German professional safety automation manufacturer)
772140 / 772142 / 772143: Unique factory part numbers of PILZ
PNOZ: Main series code for PILZ safety relays
X: X Series – Compact general-purpose safety relays, DIN rail mounted, cost-effective basic type
2: Contact configuration code – 2 sets of force-guided safety normally open (NO) contatti
1.2 Model Correspondence Table
| Factory Part No. | Modello completo | Tensione di alimentazione | Differenza chiave |
| 772140 | PNOZ X2 24V AC/DC | 24V CA/CC | Most widely used in industrial control, compatible with DC systems for PLCs and sensors |
| 772142 | PNOZ X2 110V AC | 110V e | Suited for Japanese-style equipment and power supply systems in some overseas regions |
| 772143 | PNOZ X2 230V AC | 230V e | Matches domestic industrial mains power and European standard AC systems |
Nota: All three models adopt automatic reset without manual reset function. Built-in dual-channel safety detection and force-guided contacts (core safety structure of safety relays to prevent failure caused by contact welding).
- Specifiche tecniche principali
Except for supply voltage, all electrical, mechanical and safety parameters are identical for the three models, as summarized below:
| Categoria | Articolo | Specifiche | Osservazioni |
| Basic Properties | Tipo di prodotto | Dual-channel Safety Relay | Dual-channel monitoring for safety circuits, compliant with machinery safety regulations |
| Safety Contacts | 2 × Force-guided Normally Open (NO) Contatti | Nessun contatto ausiliario, pure safety output | |
| Reset Mode | Ripristino automatico | Automatically restarts after safety circuit recovers, no manual button required | |
| Montaggio | Standard 35mm DIN Rail Mount | Universal installation for control cabinets | |
| Protezione dall'ingresso | IP40 | For indoor cabinet use; a prova di polvere, not resistant to water splashing | |
| Parametri Elettrici | Tensione operativa nominale | 772140: 24V CA/CC | Coil supply voltage |
| 772142: 110V e | |||
| 772143: 230V e | |||
| Rated Contact Load AC-15 | 230V / 6UN | Applicable to resistive and inductive loads | |
| Rated Contact Load DC-13 | 24V / 6UN | Load capacity for DC circuits | |
| Massimo. Switching Voltage | 250V e / 30A DC | Upper voltage limit for output circuits | |
| Typical Response Time | <20 ms | Fast safety actuation to ensure reliable emergency stop | |
| Consumo energetico | ca. 2.5W | Low power loss, low heat generation during long-term operation | |
| Parametri Ambientali | Temperatura operativa | 0℃ ~ +55 ℃ | Standard industrial control environment |
| Temperatura di conservazione | -25℃ ~ +70 ℃ | Temperature range for storage and transportation | |
| Umidità relativa | 10% ~ 90% (Senza condensa) | Condensation and frost are prohibited | |
| Safety Ratings | Machinery Safety Category | Cat. 3 | Conforme alla norma EN ISO 13849-1 |
| Livello di prestazione | PL d | Standard safety level for mainstream automated equipment | |
| Livello di integrità della sicurezza | SIL 2 | Conforme alla norma CEI 61508 functional safety standard | |
| Certificazioni | Approvazioni | TÜV, CE, cULus | Globally recognized industrial certifications, eligible for export |
| Fisico & Cablaggio | Dimensioni (L × A × P) | 22.5 × 94 × 120 mm | Narrow compact design, consente di risparmiare spazio nell'armadio |
| Tipo di connessione | Terminali a vite | Reliable wiring, suitable for environments with mechanical vibration | |
| Peso | ca. 140 G | Lightweight rail-mounted module |
- Full Range List (PNOZ X2 Family)
Same structure and contact configuration; differentiated only by voltage and reset mode for convenient replacement and selection:
| Parte n. | Modello completo | Tensione di alimentazione | Reset Mode | Descrizione |
| 772140 | PNOZ X2 24V AC/DC | 24V CA/CC | Ripristino automatico | Mainstream standard model |
| 772141 | PNOZ X2 48V AC | 48V e | Ripristino automatico | Special low-volume voltage version |
| 772142 | PNOZ X2 110V AC | 110V e | Ripristino automatico | For 110V AC power systems |
| 772143 | PNOZ X2 230V AC | 230V e | Ripristino automatico | For 220/230V mains systems |
| 772100 | PNOZ X2 24V AC/DC | 24V CA/CC | Ripristino manuale | Requires external reset button for high-safety applications |
Extended: Main Related Models of PNOZ X Series
| Modello | Configurazione dei contatti | Posizione dell'applicazione |
| PNOZ X1 | 1 Safety Normally Open Contact | Basic single safety circuit monitoring |
| PNOZ X3 | 3 Safety Normally Open + 1 Auxiliary Normally Closed Contact | Multiple output circuits with signal feedback |
| PNOZ X4 | 4 Safety Normally Open Contacts | Synchronous cut-off for multiple loads |
- Cross-Generation & Sostituzione tra marchi diversi
4.1 Internal Replacement within PILZ
Stato del prodotto: 772140/772142/772143 (PNOZ X2) are active mass-production models, no obsolescence or direct discontinued replacements.
Alternative aggiornate (Prestazioni più elevate, backward compatible):
PNOZ X2.8P: Equipped with diagnostic output and optimized terminals; pin-compatible for direct replacement.
PNOZ X3: Recommended if additional auxiliary feedback contacts are required.
Downgraded Replacement: Non disponibile. PNOZ X2 is the entry-level model of X series.
4.2 Equivalenti cross-brand (Same Safety Rating: Cat.3 / PL d)
| Marca | Modello | Tensione di alimentazione | Configurazione dei contatti | Nota sulla compatibilità |
| Schmersal | SRB 301ST | 24V/110V/230V | 2 NO Safety Contacts | Identical function and rating, similar wiring logic |
| SIEMENS | 3TK2821 | 24V CA/CC / 230V e | 2 NO Safety Contacts | Popular German alternative, universal DIN rail mounting |
| Schneider Electric | XPSAC01 | 24V/230 V | 2 NO Safety Contacts | Preferred for cabinets with Schneider components |
| ABB | JSBR4 | 24V/230 V | 2 NO Safety Contacts | Widely used for European and American projects |
| Weidmüller | SAFE-SR2 | 24V CA/CC | 2 NESSUN contatto | Cost-effective option for domestic control cabinets |
Important Reminder: Always verify wiring diagrams and safety circuit logic when replacing safety components. Do not replace merely based on appearance to avoid safety hazards.
4.3 Alternative domestiche
Modelli consigliati: IDEC HR1S, Tianyi safety relays
Scenari applicabili: Non-high-risk equipment and ordinary domestic automated production lines
Restrictions: Not recommended for high-end export equipment, robotic systems, presses and stamping machines.
- Ambienti applicativi & Casi di settore
5.1 Main Application Scenarios
This universal safety relay is used for industrial equipment requiring safe power circuit cut-off. Typical monitored components:
- Circuito di arresto di emergenza (full equipment emergency shutdown)
- Mechanical safety gates and guard switches (power cut-off once gates are opened)
- Safety light curtains and area scanners (shutdown protection when personnel enter hazardous areas)
- Two-hand control buttons (prevent misoperation on pressing and riveting machines)
- Safety limit switches and travel safety contacts
5.2 Applicable Industries
Machine Tool Processing: Lathes, fresatrici, centri di lavoro, grinders
Confezione & Logistica: Macchine per l'imballaggio, palletizers, trasportatori, sorting equipment
Produzione automobilistica: Welding, assembly and coating production lines
Rubber & Plastic Injection: Macchine per stampaggio ad iniezione, estrusori, die-cutting equipment
Automazione generale: Robotic workstations, custom automated machinery
Macchinari per l'industria leggera: Stampa, textile and food processing equipment
5.3 Suitable Operating Conditions
Standard indoor control cabinets, normal temperature, dust-free or slightly dusty environments
Conventional power frequency systems (24V/110V/230V power supply)
Circuits with frequent start-stop and demand for rapid safety cut-off
5.4 Not Recommended Scenarios (Precauzioni)
- Explosion-proof Areas: No explosion-proof certification. Use dedicated PILZ explosion-proof safety relays for explosive workshops.
- Outdoor Exposure / High Humidity & Condensation: IP40 protection is insufficient; an additional protective enclosure is required.
- Severe Electromagnetic Interference: (Near high-frequency welders or large inverters) Shielding measures and independent earthing are necessary.
- Overload Operation: Contact current must not exceed 6A. Add intermediate contactors for high-power loads.
- Ambient Temperature above 55℃: Will shorten service life of safety contacts and cause false tripping.
5.5 Casi applicativi tipici
Caso 1: Safety Protection for Vertical Machining Center
Configurazione: 772140 (24V CA/CC) + Safety gate switch + Emergency stop button
Funzione: Opening the equipment guard gate → Safety relay actuates → Cuts off power to spindle and feed motors; Automatic reset and restart after gate closure.
Vantaggi: Complies with machine safety standards and prevents personnel from entering mechanical hazardous zones.
Caso 2: Food Flow Wrapper
Configurazione: 772143 (230V e) + Safety light curtain
Funzione: If operators accidentally reach into the operating area → Light curtain triggers → Relay cuts off main drive power.
Vantaggi: IP40 rating adapts to slight water vapor in workshops; automatic reset ensures continuous production.
- Guida alla selezione del modello
Quick Reference Rules
- The three part numbers differ only in coil voltage, with identical appearance, contacts and functions:
772140 = 24V AC/DC (Universale, first choice)
772142 = 110V AC (For Japanese-style and overseas equipment)
772143 = 230V AC (For domestic 220V mains power)
- PNOZ X2 = 2 safety NO contacts + Ripristino automatico
- Priorità di selezione: Confirm control cabinet supply voltage first, then verify reset mode (automatic / manual).
- Risoluzione dei problemi
| Fenomeno di guasto | Probable Cause | Soluzione |
| Power indicator off, no response | Broken coil wiring, loose terminals, power failure | Measure input voltage, tighten screws, check upstream circuit breakers and fuses |
| Frequenti falsi interventi | Loose wiring in safety circuit, electromagnetic interference, poor contact of gate switches | Re-crimp terminals, route cables away from power lines, replace worn safety switches |
| Safety circuit normal but relay fails to energize | Aged internal contacts, damaged coil, end of service life | Replace with an identical safety relay (Safety components are not repairable) |
| Output contacts cannot open (welded) | Sovraccarico a lungo termine, cortocircuito del carico, frequent high-current surges | Replace the relay; add intermediate contactors for current division; never exceed 6A rated current |
| Abnormal reset, failed automatic restart | Incomplete closure of safety circuit, line short to ground | Check continuity of the entire safety circuit and eliminate short circuits |
Safety Regulation: Faulty safety relays are prohibited from disassembly and repair. The complete unit must be replaced.
- Ordinare, Confezione & Conformità
8.1 Ordering Details
| Factory Part No. | Modello completo | Tensione di alimentazione | Imballaggio standard |
| 772140 | PNOZ X2 24V AC/DC | 24V CA/CC | 1 unità per scatola |
| 772142 | PNOZ X2 110V AC | 110V e | 1 unità per scatola |
| 772143 | PNOZ X2 230V AC | 230V e | 1 unità per scatola |
8.2 Commercial & Storage Information
Minimum Order Quantity: 1 pezzo
Origine: Germania (Original PILZ product)
Spare Parts Suggestion: Prepare 1 unit of corresponding voltage model for every 10 sets of similar equipment
Stato del prodotto: Produzione di massa, long-term stable supply
8.3 Logistics Compliance
No lithium batteries, supercapacitors or hazardous materials inside. Classified as general low-voltage electrical component.
No special restrictions for air, sea and land transportation; no additional dangerous goods declaration required.
8.4 Standard & Approvazioni
Standard applicabili: NELL'ISO 13849-1, CEI 61508, IN 60947-5-1
Certificazioni: CE, TÜV, UL. Approved for use in EU, North America and most regions worldwide.
- Supplementare: Basic Wiring Instructions
- Coil Power Supply: Apply corresponding rated voltage to coil terminals (A1/A2).
- Safety Input Circuit: Wire emergency stop buttons and safety gates in series to dual-channel inputs.
- Safety Output Circuit: Connect 2 sets of NO safety contacts in series to the control circuit of main contactors.
- Principio di cablaggio: Adopt series connection for safety circuits. The relay will immediately cut off outputs once any safety component opens.
Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari