Schneider GV2-P22 Motor Circuit-Breaker

Model Code Explanation GV2-P22 GV2: Serie, motor-protection circuit-breaker (manual motor starter) P: Thermal-magnetic protection type, rotary-knob current adjustment 22: Current setting range 20-25A Core Parameters Setting current: 20~25A Tripping characteristic: Thermal-overload trip + instantaneous magnetic short-circuit trip Main circuit: 3-pole Applicable motor: AC-3, motore trifase, massimo. approx.11kW (380V) Auxiliary functions: Compatible with add-on blocks GV2-AE, ...

  • Dettagli del prodotto

Spiegazione del codice modello

GV2-P22

GV2: Serie, motor-protection circuit-breaker (manual motor starter)

P: Thermal-magnetic protection type, rotary-knob current adjustment

22: Current setting range 20-25A

Parametri fondamentali

  1. Impostazione della corrente: 20~25A
  2. Caratteristica di intervento: Thermal-overload trip + instantaneous magnetic short-circuit trip
  3. Circuito principale: 3-palo
  4. Applicable motor: AC-3, motore trifase, massimo. approx.11kW (380V)
  5. Auxiliary functions: Compatible with add-on blocks GV2-AE, GV2-AN
  6. Montaggio: 35 mm DIN-rail mounting; assembled with contactor for direct-on-line starting unit

Common Replacements

Schneider in-series alternative: GV2-ME22 (lever-handle version, same 20-25 A range)

Alternative domestiche: Chint NS2-25 (20-25UN), Delixi CDV2s-25 (20-25UN)

Second-hand Inspection Checklist (for used-market purchase)

  1. Controllare l'alloggiamento per eventuali crepe, burn marks or burnt terminal lugs
  2. Rotary knob should turn smoothly without jamming
  3. Verify normal closing and opening operations
  4. Cross-check nameplate: GV2-P22, 20-25 UN; do not confuse with GV2-P21 (17-23 UN)
  5. Distinguish models: GV2-P uses rotary knob; GV2-ME uses lever handle. Different housings, not directly interchangeable.

Schneider GV2-P22 Motor Circuit-Breaker Full Specification Sheet

>Serie: TeSys Deca GV2-P (imported rotary-knob manual motor starter)

  1. Informazioni di base sul modello
ArticoloSpecifica
ModelloGV2‑P22
Tipo di prodottoManual motor‑protection circuit‑breaker (Manual Motor Starter)
OperazioneRotary‑knob operation (vs lever‑handle GV2‑ME)
Poli3P (3-polo)
Tipo di protezioneMagnetotermico: thermal‑overload protection + instantaneous magnetic short‑circuit protection
Thermal trip setting range20-25A
Magnetic trip current13×In ≈327 A (instant short‑circuit tripping)
Phase‑failure protectionSupportato
Disconnect functionMain‑circuit isolation capability
  1. Parametri Elettrici
ArticoloSpecifica
Tensione operativa nominale UeAC 690 V, 50/60 Hz
Tensione nominale di isolamento Ui690 V AC
Tensione nominale di tenuta ad impulso Uimp6 kV
Corrente termica convenzionale Ith25 UN
Categoria di utilizzoAC‑3, AC‑3E (carico del motore), Category‑A circuit‑breaker
Applicable 3‑phase motor power11 kW@400‑415 V; 15 kW@500 V
Power dissipation per pole2.5 W

Rated Ultimate Short-circuit Breaking Capacity Icu

VoltaggioIcu Breaking Capacity
230‑240 V100 kA
400‑415 V50 kA
440 V20 kA
500 V10 kA
690 V4 kA
  1. Vita meccanica & Cablaggio
ArticoloSpecifica
Resistenza meccanica100 000 operating cycles
Electrical endurance AC‑3@415 V100 000 cycles
Frequenza operativa massima25 operazioni all'ora
Tipo di terminaleMorsetti con morsetto a vite
Coppia di serraggio1.7 N·m
Compatible conductorsSolid wire 1‑6 mm²; flexible wire with ferrule 1‑4 mm²; un‑ferruled flexible wire 1.5‑6 mm²
Metodo di montaggio35 mm standard DIN‑rail clip‑on mounting; or panel mounting with M4 screws
Orientamento di montaggioHorizontal or vertical installation, no orientation restriction
Dimensioni complessiveW 45 mm × H 89 mm × D 97 mm
Unit weightca. 339 G
  1. Ambiente & Protezione
ArticoloSpecifica
Enclosure protection ratingIP20 (terminal side)
Impact resistance IK‑ratingIK04
Temperatura ambiente operativa‑20 ℃ ~ +60 ℃
Temperatura di conservazione‑40 ℃ ~ +80 ℃
Resistenza alle vibrazioni5 Gn, 5‑150 Hz; shock resistance 30 Gn/11 ms
Glow‑wire resistance960 ℃ glow‑wire test
  1. Certificazioni & Accessori
  2. Certificazioni: CCC, UL, CSA, EAC, DNV-GL, BV, RINA, LROS marine classification, ATEX, UKCA, RoHS / PORTATA
  3. Consegna standard: Unit only, no built-in auxiliary contacts; must order separately

Blocchi di contatti ausiliari: GV2-AN (1NA+1NC), GV2-AE (fault-signal contact)

Viaggio di derivazione, intervento per sottotensione, door-interlock mechanism and others are optional accessories

  1. Origin note: GV2-P22 is imported version. Domestic rotary-knob variant GV2PM22 shares same current range but differs in breaking-capacity and depth dimension; cannot be treated as full equivalent replacement.
  2. In-series Comparison & Selezione della sostituzione
  3. Schneider lever-handle equivalent: GV2-ME22 (20-25 UN, lever-handle type, different housing outline, accessories are interchangeable)
  4. Domestic alternative references:

Chint NS2-25 20-25A

Delixi CDV2s-25 20-25A

  1. Second-hand Inspection Checklist (Used-market)
  2. Nameplate verification: Model GV2-P22, 20-25 UN. Do not confuse with GV2-P21 (17-23 UN).
  3. Rotary knob turns smoothly, ON/OFF positions clear, nessun attaccamento.
  4. Housing free of cracks; terminal lugs without burning or erosion.
  5. Perform manual close-open test. If possible, verify thermal-trip and magnetic-trip functions.
  6. Distinguish GV2-P (imported, depth 97 mm) vs GV2PM (domestico, depth 91 mm). Housings are not directly interchangeable.

Application Scenarios for Schneider GV2-P22 Motor Circuit-Breaker

GV2-P22 (adjustable 20-25 A, max 11 kW three-phase motor @400 V) belongs to TeSys GV2-P rotary-knob thermal-magnetic manual motor starter. It integrates short-circuit protection, motor overload protection, phase-failure protection and main-circuit isolation. It performs local motor on-off control and is frequently paired with contactors and overload relays for motor starting circuits. Widely deployed for small-to-medium three-phase motors in industrial machinery, linee di trasporto, HVAC, light lifting and pump systems.

✅ Typical Load Matching (400 V three-phase reference)

Potenza motore corrispondente: 7.5 kW ~11 kW three-phase asynchronous motor

Nota: Only select this model when the motor full-load current falls within the 20-25 A window. Do not over-size the setting for smaller motors, otherwise overload protection will be lost.

  1. Industrial Equipment Applications
  2. Machine-tool equipment

Macchine perforatrici, small milling machines, smerigliatrici, light cutting equipment; machine-tool cooling pumps, hydraulic-station oil-pump motors.

Funzione: Instant tripping for motor stall, overload and winding short-circuit. Rotary knob provides local manual switching plus isolation for maintenance.

  1. Trasportatore & material-handling lines

Trasportatori a nastro, trasportatori a rulli, piccoli ascensori, sorting-equipment drive motors.

Vantaggio: Compact DIN-rail installation for dense cabinet layout. GV2-AE fault-alarm block can be added to send fault signals to PLC.

  1. Fan & Sistemi HVAC

Industrial centrifugal fans, cabinet fans, workshop exhaust fans, air-handling-unit fan motors.

Suited for fan-type high-inrush-current loads; thermal-magnetic characteristic tolerates starting surge while protecting against sustained overload.

  1. Pump applications

Pompe di circolazione, pompe per fognature, booster pumps, small hydraulic oil pumps.

Sewage pumps are prone to rotor stalling; built-in phase-failure protection prevents motor burnout from single-phasing. Rotary knob provides local switching and maintenance isolation inside control cabinets.

  1. Control-cabinet Integration
  2. Direct-on-line motor starter circuits (più comune)

Schema1: Stand-alone GV2-P22 for local manual protection & switching for small motors without remote control.

Schema2: GV2-P22 + LC1D contactor forming a complete DOL starter: circuit-breaker provides short-circuit & protezione da sovraccarico; contactor executes PLC-based remote start-stop.

Classic configuration widely used inside PLC cabinets and MCC motor-control boxes.

  1. Local field control boxes

Compact on-machine local control enclosures. Rotary knob switches motor and provides electrical isolation in OFF position, removing need for separate disconnector.

  1. Other Industry Uses
  2. Logistica & light lifting equipment

Piccoli argani, auxiliary lifting motors (not for primary hoist safety circuits).

  1. Plastics-processing machinery

Auxiliary small extruder drives, hopper feeding motors, mixer motors.

  1. Marino / offshore auxiliary equipment

GV2-P series carries full marine classification-society approvals for on-board auxiliary pumps and ventilation fans inside engine compartments. ⚠️ Domestic GV2PM lacks full marine certifications; imported GV2-P must be specified for marine projects.

❌ Not-Recommended Applications

  1. Not intended for single-phase loads or lighting circuits: Optimized specifically for motor protection logic, not general-purpose distribution.
  2. Potenza del motore >11 kW @400 V: Exceeds setting-current range; upgrade to GV3-series.
  3. Downstream of VFD output terminals: Cannot connect to inverter output side. Only install on VFD input supply side for upstream protection.
  4. Frequent forward-reverse jog-cycle operation: Add contactor for repeated switching; avoid frequent manipulation of the GV2-P rotary knob to preserve mechanical service-life.

💡 Selection & Operation Tips

  1. Adjust rotary setting dial strictly according to motor nameplate full-load current. Do not simply turn to maximum 25 A; set to 21 A for a motor rated 21 A.
  2. Remote fault-signal output requires add-on GV2-AE fault-contact block; no alarm output built-into unit.
  3. GV2-P22 is imported rotary-knob variant. While protection parameters match lever-handle GV2-ME22, physical depth differs; check cabinet depth for retrofit replacement.
  4. For used-unit deployment: Prioritize functional trip-test rather than cosmetic inspection only.