LXM32: Lexium32 series servo
M: Multi-fieldbus version (CANopen supported, built-in encoder acquisition and positioning function)
D72: Peak output current 72A, continuous 24A
N4: 3-phase high-voltage model, 208~480VAC 3-phase power supply
Specifiche elettriche principali
| Articolo | Specifica |
| Alimentazione elettrica | 3-phase AC 208~480V, 50/60Hz |
| Potenza nominale | 400Classe V: 7kW; 230Classe V: 5kW |
| Corrente di uscita continua | 24UN (8kHz carrier frequency) |
| Corrente di picco in uscita | 72UN, sustainable for 5s |
| Filtro EMC integrato | Standard integrated |
| Speed Loop Bandwidth | Up to 1600Hz, high dynamic response |
| Frequenza portante | 8kHz |
| DC Bus Undervoltage Threshold | 350V (400Classe V) |
Comunicazione & I/O
- Bus di campo: CANopen (LXM32M model, different from pulse-type LXM32A)
- Digitale: Multiple 24VDC discrete inputs including 2 high-speed capture CAP ports; uscite digitali
- Interfaccia dell'encoder: Supports SinCos and EnDat, compatible with BSH/BMH servo motors
- Interfacce: RJ45 debug port, Terminali rimovibili codificati a colori per un comodo cablaggio e manutenzione dell'armadio
Motori corrispondenti
Compatibile con BSH / Classe BMH 400 V servomotori della serie Lexium32. Partita tipica: 140-motore flangiato BSH ad alta coppia, coppia continua fino a 27,8 N·m, picco 90,2 N·m, velocità comune 3000 giri/min.
Scenari applicativi
Macchine per l'imballaggio, assi di avanzamento della macchina utensile, Taglio CNC, macchine tessili, trasporto di movimentazione materiali, apparecchiature di sincronizzazione multiasse; adatto per linee di produzione automatizzate che richiedono il collegamento multiasse del bus CANopen e un posizionamento altamente dinamico.
Installazione & Ambiente
Montaggio in armadio a libro, installazione verticale su guida DIN del quadro elettrico
Categoria di sovratensione: Classe III
Corrente di dispersione massima: 30mA
Sezione del filo consigliata per i terminali di alimentazione: 3mm², coppia di serraggio 0,5 N·m
Colpa & Note sulla messa in servizio
- Allarmi comuni: OC di sovracorrente, Sovratensione OV, Sottotensione UV, Guasto dell'encoder, Surriscaldamento OH
- Software di messa in servizio: Quindi Muoviti, supporta la configurazione dei parametri online, campionamento dell'oscilloscopio e sintonizzazione automatica dell'inerzia
- Per condizioni di lavoro ad alta potenza, si consiglia di installare una reattanza di linea esterna da 1 mH per ridurre le armoniche e i picchi di corrente in ingresso
Sostituzione & Osservazioni sulla selezione
Versione a impulsi della stessa serie: LXM32AD72N4 (niente CANopen, controllo della direzione degli impulsi)
Alternativa all'aggiornamento: Schneider Serie Lexium28; concorrenti comparabili: Siemens V90, MitsubishiMR-J4
Nota: LXM32 è una serie legacy fuori produzione. Lexium28 è preferito per i nuovi progetti; le unità in stock o di seconda mano sono disponibili solo per progetti di pezzi di ricambio.
Riferimento al codice SA
85011099 (servoazionamento, verificare nuovamente la classificazione doganale prima della dichiarazione doganale)
LXM32MD72N4 Modello dei parametri di messa in servizio all'accensione SoMove
Applicabile: Servo bus CANopen Lexium32M da 7 kW, abbinato a motori BSH/BMH 400V; Software SoMove, password della modalità esperto 696969
Pre-operazione: Cablaggio hardware completo compreso cavo di alimentazione, codificatore, arresto di emergenza, freno, CAN bus e alimentazione di controllo a 24 V; eseguire prima il test di spostamento senza carico, quindi eseguire la sintonizzazione automatica sotto carico; salvare i parametri su EEPROM dopo la modifica.
- Configurazione di base (Avvia semplicemente la pagina della procedura guidata)
| Nome del parametro | Identificativo del parametro | Impostazione consigliata | Descrizione |
| Control Source | DEVcmdInterf | Bus di campo | LXM32M CANopen positioning mode; temporarily change to Terminal for local jog |
| Motor Selection | Motor Selection | Select corresponding BSH/BMH model | Drive loads motor nameplate parameters automatically; must not select incorrectly |
| Tipo di codificatore | ENC1_type | SinCos / EnDat | Select according to motor encoder; EnDat absolute encoder requires battery module |
| Frequenza portante | PWM_Freq | 8kHz | Default for LXM32MD72N4, not recommended to increase |
| Direzione di rotazione | InvertDirOfMove | SPENTO (Predefinito) | Set to ON if rotation direction reversed; power cycle required after change |
| Auto Enable on Power-up | IO_AutoEnable | 0 (Disabled) | Disabled during commissioning; can be set to 2 for mass production after safety assessment |
- Axis Limit Parameters (Axis Configuration → Limitations)
| Nome del parametro | Identificativo del parametro | Impostazione consigliata | Descrizione |
| Corrente di uscita massima | CTRL_I_max | Corrente nominale del motore | Limit maximum torque to protect machinery; cannot exceed 72A peak of drive |
| Max Motor Speed | M_n_max | Velocità nominale del motore | Typical 3000rpm for BSH/BMH, do not exceed nameplate |
| Positive Software Limit | POS_LIM_P | Unità utente | Limite rigido meccanico interno per impedire la corsa eccessiva |
| Limite software negativo | POS_LIM_N | Unità utente | Uguale al limite positivo |
| Decelerazione dell'arresto di emergenza | QS_Dec | Costume | Decelerazione innescata dall'arresto di emergenza, legati alla sicurezza |
- I/O & Parametri di sicurezza (Configurazione asse → IO)
| Nome del parametro | Identificativo del parametro | Impostazione consigliata | Descrizione |
| Contatto limite positivo | IOsigLIMP | NC Normalmente Chiuso | Predefinito per gli standard di sicurezza; impostare su NO se si utilizzano sensori normalmente aperti |
| Contatto limite negativo | IOsigLIMN | NC Normalmente Chiuso | Come sopra |
| Ritardo rilascio freno | BRK_AddT_Release | 100SM | Motore con freno: attendere il rilascio del freno prima del movimento dopo l'abilitazione del servo |
| Ritardo di applicazione del freno | BRK_AddT_Applica | 50SM | Ritarda l'uscita del freno dopo la disabilitazione del servo per evitare la caduta dell'asse |
| Ripristino guasto | IO_FaultReset | Assegnare il terminale IN | Pulsante di ripristino esterno |
- Ridimensionamento della posizione (Ridimensionamento, Nucleo per il posizionamento dei progetti)
Unità utente per giro, esempio: 10mm per giro per vite madre, modificare come richiesto
| Nome del parametro | Identificativo del parametro | Valore di esempio | Descrizione |
| —| —| —| —|
| Numeratore di posizione | ScalaPOS | 10 | Numeratore della corsa per giro |
| Denominatore di posizione | ScalePOSdenom | 1 | Denominatore; esempio: 10mm/giro → 10/1 |
| Velocity Scaling | ScaleVELnum / ScaleVELdenom | Follow position | Velocity unit: mm/s |
| Acceleration Scaling | ScaleACCnum / ScaleACCdenom | Follow position | Acceleration unit: mm/s² |
Raw encoder resolution: 16384count/rev for SinCos motors
- Servo Loop Gains (Tuning Page, No-load → On-load Auto-tune)
Prioritize SoMove automatic inertia identification + auto-tune, then fine tune
| Nome del parametro | Identificativo del parametro | Initial Recommendation | Tuning Logic |
| —| —| —| —|
| Position Loop Gain | CTRL_Kp_pos | 3~8 | Higher for stiff mechanics; reduce if oscillation occurs |
| Speed Loop Gain | CTRL_Kp_vel | 80~150 | Base response, reduce for mechanical resonance |
| Speed Loop Integral Time | CTRL_Ti_vel | 8~20ms | Smaller value improves steady-state error, prone to oscillation |
| Velocity Feedforward | CTRL_Kff_vel | 0.6~0.9 | Reduce position following error |
| Acceleration Feedforward | CTRL_Kff_acc | 0~0.3 | For high-speed start-stop; large value causes impact |
| Low-pass Filter | CTRL_FiltVel | 500~1000Hz | Suppress resonance; lower filter frequency at resonance point |
- CANopen Fieldbus Parameters (Key for LXM32M)
| Nome del parametro | Identificativo del parametro | Impostazione consigliata | Descrizione |
| CAN Node ID | CAN_NodeID | 1~127 | No duplicate for multi-axis, consistent with PLC |
| CAN Baud Rate | CAN_Baud | 500kbps | Common setting; use 250kbps for long distance, terminal resistor ON at both bus ends |
| PDO Mapping | PDO Configuration | Standard positioning PDO | Target position, parola di stato, actual position, fault code |
| Fieldbus Control Mode | Profile Mode | Profile Position | Positioning control; select Profile Velocity for speed axis |
| Profile Acc/Dec | PRO_ACC / PRO_DEC | Mechanical dependent | Unità: user unit/s |
| Quick Stop Ramp | PRO_QSDec | Independent E-stop deceleration | Deceleration upon bus failure |
- Homing Parameters
| Nome del parametro | Identificativo del parametro | Descrizione |
| Homing Mode | HOM_mode | 0~35 optional; comune: limit homing, index homing, direct origin setting for absolute encoder |
| Homing Velocity | HOM_Vel | Bassa velocità, 50~200 user unit/s |
| Homing Search Velocity | HOM_Vel_Search | Slightly higher than homing speed |
| Homing Offset | HOM_Offset | Mechanical origin offset |
- Monitoraggio & Fault Log
Fault Buffer: Stores latest 16 alarms for troubleshooting of OV/OC/OH/ENC faults
Oscilloscopio: Sample target position, actual position, seguente errore, bus voltage, motor current for resonance and tuning analysis
Salva: Device → User Functions → Save parameters to EEPROM; back up local project as .cxm file
Complete Power-on Commissioning Procedure (Matching Parameter Template)
- Connect PC to drive RJ45 debug port via SoMove, establish communication and read factory parameters
- Run Simply Start wizard, select motor model and confirm encoder type
- Configure limit, brake and I/O terminal definition
- Set position scaling and mechanical transmission ratio
- Set CANopen Node ID, baud rate and configure PDO
- Prova a vuoto: Abilitare, jog, verify rotation direction, limit and brake logic
- On-load test: Run Auto-tune inertia identification to generate base gains
- Observe following error and oscillation via oscilloscope, fine-tune 3-loop gains and filter
- Prova di homing, prova di posizionamento del punto, prova di accelerazione/decelerazione
- Salvare i parametri su EEPROM ed esportare il file di backup .cxm
Precauzioni per la messa in servizio
- Password della modalità esperto 696969, accedere alla modalità esperto per modificare i parametri avanzati
- La sintonizzazione automatica deve essere eseguita con il carico effettivo; i parametri sintonizzati a vuoto oscillano facilmente sotto carico
- Una sincronizzazione errata del freno causerà direttamente la caduta dell'asse; testare il funzionamento del freno senza carico durante la prima messa in servizio
- autobus CANopen: Abilitare la resistenza terminale solo sul primo e sull'ultimo dispositivo sul bus, disabilitare per i nodi intermedi
- Per LXM32MD72N4 ad alta potenza, controllare il cablaggio della reattanza di linea e della resistenza di frenatura prima della prima accensione
Parametri estesi facoltativi
Resistenza di frenatura: BRK_R, BRK_P per resistenza/potenza nominale del resistore di frenatura esterno, protezione da sovratensione del bus
Ingresso analogico: Ridimensionamento AI per la modalità di velocità analogica (non comunemente utilizzato per i progetti CANopen)
SchneiderLexium32 (LXM32) Full Series Drive Model List
3 main branches: LXM32C (Basic Analog) / LXM32A (Impulso + ModBus) / LXM32M (CANopen bus type, LXM32MD72N4 belongs to this branch)
Spiegazione del suffisso:
M2: Single-phase 200~240VAC; N4: 3-phase 208~480VAC
Dxx: Number after D = peak current (UN), continuous current = 1/3 of peak current
Stato: Full series discontinued, only available on spare parts market
- LXM32M (Tipo di bus CANopen, Alta priorità, includes LXM32MD72N4)
Single-phase 200~240V (Suffix M2)
| Modello | Corrente di picco | Corrente continua | 230V Rated Power |
| LXM32MD12M2 | 12UN | 4UN | 0.75kW |
| LXM32MD18M2 | 18UN | 6UN | 1.0kW |
| LXM32MD30M2 | 30UN | 10UN | 1.6kW |
| LXM32MD42M2 | 42UN | 14UN | 2.5kW |
| LXM32MD57M2 | 57UN | 19UN | 3.5kW |
3-phase 208~480V (Suffix N4, your series)
| Modello | Corrente di picco | Corrente continua | 400V Rated Power |
| LXM32MD12N4 | 12UN | 4UN | 0.9kW |
| LXM32MD18N4 | 18UN | 6UN | 1.8kW |
| LXM32MD30N4 | 30UN | 10UN | 3kW |
| LXM32MD42N4 | 42UN | 14UN | 4.5kW |
| LXM32MD57N4 | 57UN | 19UN | 5.5kW |
| LXM32MD72N4 | 72UN | 24UN | 7kW |
| LXM32MD85N4 | 85UN | 32UN | 9kW |
- LXM32A (Pulse/Direction + ModBus, niente CANopen, stessa potenza)
Single-phase M2
LXM32AD12M2, LXM32AD18M2, LXM32AD30M2, LXM32AD42M2, LXM32AD57M2
3-phase N4
LXM32AD12N4, LXM32AD18N4, LXM32AD30N4, LXM32AD42N4, LXM32AD57N4, LXM32AD72N4, LXM32AD85N4
- LXM32C (±10V analog basic model, speed/current control only, no positioning)
Single-phase M2
LXM32CD12M2, LXM32CD18M2, LXM32CD30M2, LXM32CD42M2, LXM32CD57M2
3-phase N4
LXM32CD12N4, LXM32CD18N4, LXM32CD30N4, LXM32CD42N4, LXM32CD57N4, LXM32CD72N4, LXM32CD85N4
- Matching Motor Series (BSH / BMH for Lexium32)
- BSH Motors: SinCos encoder, single-turn/multi-turn, IP50; flange sizes 55/70/100/140mm
- BMH Motors: EnDat absolute encoder, multigiro, IP65; flange sizes 55/70/100/140/190mm
- Elenco degli accessori (General for LXM32)
VW3M8101: Resistenza di frenatura
VW3M8D10: Encoder battery box (for EnDat multi-turn BMH motors)
VW3M8102: Line reactor
VW3M8200: Pre-made I/O terminal cable
VW3M8300: CANopen bus cable
VW3M8400: Cavo di alimentazione del motore
VW3M8500: Cavo dell'encoder
Branch Comparison Overview
| Serie di modelli | Control Interface | Positioning Function | Bus di campo | Applicazione tipica |
| LXM32C | ±10V Analog | ❌ No positioning | ModBus | Pure speed control |
| LXM32A | Impulso+Direzione | ✅ Point positioning | ModBus | Pulse PLC control |
| LXM32M | CANopen | ✅ Electronic gear / Point / Homing | CANopen | Multi-axis bus synchronization (LXM32MD72N4) |
Suggerimenti per la selezione:
- Same Dxx model: LXM32A and LXM32M have identical hardware power rating, differ only in firmware communication functions
- LXM32MD85N4 is the largest model in this series, 9kW
- New project replacement: Serie Lexium28; only stock/second-hand units available for spare part projects.
Contattore,interruttore automatico,sensore,Codificatore,PLC,Convertitore