Schneider NW32H1-4P-3200A Air Circuit Breaker (ACB) The Schneider NW32H1-4P-3200A is an air circuit breaker (ACB) from the MasterPact NW series, designed for main incoming and bus-section protection in low-voltage power distribution systems (≤690V). Featuring high breaking capacity and flexible protection configurations, it serves as a core protective component for power distribution in industrial and large ...

  • Dettagli del prodotto

Schneider NW32H1-4P-3200A Air Circuit Breaker (ACB)

The Schneider NW32H1-4P-3200A is an interruttore automatico dell'aria (ACB) from the MasterPact NW series, designed for main incoming and bus-section protection in low-voltage power distribution systems (≤690V). Featuring high breaking capacity and flexible protection configurations, it serves as a core protective component for power distribution in industrial and large commercial buildings.

  1. Spiegazione del modello
Parte del modelloDescrizione
NWSerie di prodotti: MasterPact NW series air circuit breaker
32Frame rated current: 3200UN (configurable up to 3200A)
H1Classe del potere di interruzione: 65kA@440VAC (terapia intensiva), 65kA@690VAC (Icw 1s)
4PNumero di poli: 4 poli (3 fasi + neutro)
3200UNOperational rated current: 3200UN (requires matching trip unit)
  1. Parametri tecnici fondamentali
CategoriaSpecificaNote
Parametri di base
Tipo di prodottoInterruttore automatico dell'aria (ACB)MasterPact NW series, ritirabile / fixed type available
Tensione nominale (Ue)690V CA 50/60 HzMassimo. operational voltage Ui = 1000V
Tensione di isolamento nominale (Ui)1000V eConforme all'IEC 60947-2
Tensione nominale di resistenza all'impulso (Ump)12kVEnsures insulation safety
Frame Rated Current (Iu)3200UNConfigurable rated current In ≤ 3200A
Capacità di interruzione (terapia intensiva)65kA@440VACClass H1, 3-second withstand current Icw = 65kA@690VAC
50kA@690VAC
Poli4P (3L+N)Neutral position selectable (left / Giusto)
Meccanico & Installazione
MontaggioWithdrawable (standard) / FissoWithdrawable for easy maintenance
OperazioneManuale / motor stored energy + manual / motor operationMotor operation mechanism optional
Dimensionica. 465×550×420mmSlightly varies by mounting type
Pesoca. 85kgFixed type slightly lighter
Funzioni di protezione
Standard ProtectionSovraccarico prolungato (l), short-time short-circuit (S), cortocircuito istantaneo (IO)Requires Micrologic / ET series trip units
Optional ProtectionProtezione dai guasti a terra (G), residual current protection (RCD)Supported by advanced trip units
Funzione di isolamentoConforme alla norma EN / CEI 60947-2Can be used as isolating device
Trip Compatibility
Supported Trip UnitsMicrologic 2.0 / 5.0 / 6.0 serieDifferent function levels available
ET2E / ET6E series
ComunicazioneModBus, Profibus, Ethernet opzionaleNetwork connectivity via advanced trips
  1. Caratteristiche del prodotto & Vantaggi
  2. Design ad alta affidabilità

Struttura modulare: Easy maintenance and expansion, component replacement without full disassembly

Vacuum interrupter: Strong arc quenching, lunga durata, suitable for frequent operation

Vita meccanica: Fino a 10,000 operations at rated current; vita elettrica 5,000 operazioni

Adattabilità ambientale: Operating temperature -5℃~+40℃, umidità ≤95% (senza condensa)

  1. Comprehensive Protection

Three-stage protection: Sovraccarico prolungato (inverse), short-time short-circuit (definite), instantaneous short-circuit for precise fault matching

Selective protection: Coordination between upstream and downstream breakers via trip settings to minimize outages

Fault memory: Advanced trips record fault type, attuale, time for diagnostics

Power monitoring: Selected trips (per esempio. Micrologic 6.0) support voltage, attuale, power and energy metering

  1. Sicurezza & Convenience

Safety interlocks: Mechanical and electrical interlocks to prevent misoperation

Withdrawable design: Maintenance without main power interruption, improving system availability

Status indication: Clear ON/OFF/energy storage indicators for on-site observation

Telecomando: Motor operation mechanism enables remote ON/OFF for automation systems

  1. Installazione & Wiring Guidelines
  2. Mounting Types

Withdrawable mounting:

Suitable for critical facilities requiring frequent maintenance (centri dati, ospedali)

Installation depth approx. 420mm with sufficient pull-out space

Conforme all'IEC 60947-2, anti-mismatch function

Montaggio fisso:

For limited space or low-maintenance applications

More compact layout, costo inferiore

Requires main power disconnection for service

  1. Requisiti di cablaggio

Main terminals: Accept cables or busbars; busbars recommended for low contact resistance

Circuito di controllo: Separate supply (AC/DC 220V or 110V) for trip and operating mechanism

Neutral position: Left or right selectable, to be specified when ordering

Coppia terminale: Tighten per Schneider official manual to avoid overheating

  1. Applicazioni & Consigli per la selezione
  2. Applicazioni tipiche

Industry: Main incoming, large motor control centers (Centro clienti), VFD front-end protection

Edifici commerciali: Main distribution for high-rises, centri commerciali, hotels

Infrastrutture: Power distribution for data centers, ospedali, aeroporti, metros

New energy: Combiner protection in PV power stations and energy storage systems

  1. Punti di selezione
Selection AspectNote
Capacità di interruzioneSelect per system short-circuit calculation; Class H1 (65kA@440V) suits most industrial sites
Selezione del viaggioProtezione di base: Micrologic 2.0; power monitoring: Micrologic 6.0; comunicazione: network-enabled models
MontaggioWithdrawable for critical loads, fixed for general loads, balancing cost and maintenance
OperazioneMotor operation for remote control; manual for local operation
Funzioni ausiliarieShunt trip for fire linkage; undervoltage trip for undervoltage protection
  1. Prezzo di riferimento & Alternative
  2. Fascia di prezzo (April 2026, Città di New York)
ConfigurazioneFascia di prezzo (Città di New York)Note
Basic frame (without trip)8,000–12,000Fisso: 8,000–10,000
Withdrawable: 10,000–12,000
With Micrologic 2.012,000–16,000Basic three-stage protection, no communication
With Micrologic 5.016,000–22.000Protezione dai guasti a terra, Modbus supported
With Micrologic 6.022,000–30,000Protezione completa, energy metering, Ethernet
With motor operation+3,000–5,000Enables remote control
  1. Sostituzione & Upgrade Models

Sostituzione diretta: MasterPact MT series (MT32H1-4P-3200A), fully compatible and advanced

Aggiornamento: Newer MasterPact NW models (per esempio. NW32H2, 85kA@440V) for higher short-circuit systems

Economical alternative: Schneider EZD series MCCBs (EZD400E43200) for lower breaking requirements

The Schneider NW32H1-4P-3200A ACB, with its 65kA high breaking capacity, flexible protection settings and reliable performance, is an ideal solution for 3200A-class low-voltage distribution systems. Proper selection of trip unit and mounting type fulfills protection needs across various scenarios, ensuring safe and stable power system operation.

Schneider Air Circuit Breaker Model List & Cross-Brand Comparison (April 2026)

At a Glance

Schneider core series: MasterPact MT/MTZ (flagship), MVS (general), NW (compatto)

Gamma attuale: 630A~6300A, covering low-voltage distribution to industrial main incomers

Cross-brand compatibility: Functionally interchangeable with ABB Emax, Siemens 3VA/3WT, CHINT NA1, Delixi CDW series

  1. Complete Schneider ACB Model List
  2. Flagship Series: MasterPact MT/MTZ (630A~6300A) 2026.4
ModelloCorrente del fotogrammaBreaking ClassPoliMontaggioConfigurazione tipicaPrezzo (Città di New York)
MT06N1 MIC2.0630UNN1 (42kA@440V)3P/4PFixed/WithdrawableBasic three-stage protection8,000~12,000
MT08H1 MIC5.0800UNH1 (65kA@440V)3P/4PWithdrawableEarth fault + ModBus15,000~22,000
MT10N2 MIC6.01000UNN2 (50kA@690V)3P/4PFixed/WithdrawableEnergy metering + Ethernet20,000~28,000
MT16H1B MIC6.01600UNH1b (80kA@440V)3P/4PWithdrawableProtezione completa + comunicazione30,000~42,000
MT25H2 MIC6.02500UNH2 (100kA@440V)3P/4PWithdrawableHigh breaking + smart monitoring55,000~78,000
MT32H2 MIC6.03200UNH2 (100kA@440V)3P/4PWithdrawableMain incoming dedicated70,000~95,000
MT40H2 MIC6.04000UNH2 (85kA@690V)3P/4PWithdrawableHeavy industrial distribution90,000~120,000
MT63H2 MIC6.06300UNH2 (70kA@690V)3P/4PWithdrawableCentri dati / power plants150,000~220,000
MTZ2 32H MIC6.03200UNH2 (100kA@440V)3P/4PWithdrawableDigital upgraded version85,000~110,000
  1. General Series: MVS (800A~2500A)
ModelloCorrente nominaleCapacità di interruzionePoliCaratteristichePrezzo (Città di New York)
MVS08N MIC5.0800UNN1 (42IL)3P/4PEconomical general-purpose12,000~18,000
MVS12H MIC5.01250UNH1 (65IL)3P/4PStandard industrial18,000~25,000
MVS16H MIC5.01600UNH1 (65IL)3P/4PHigh cost-performance22,000~30,000
MVS25H MIC6.02500UNH1 (65IL)3P/4PIntelligent type35,000~48,000
  1. Compact Series: MasterPact NW (630A~1600A)
ModelloCorrente nominaleBreaking ClassPoliSize AdvantagePrezzo (Città di New York)
NW08N1 3P800UNN1 (42IL)3P/4P30% smaller than MT10,000~15,000
NW10H1 4P1000UNH1 (65IL)4PDesign compatto13,000~18,000
NW16H1 3P1600UNH1 (65IL)3P/4PSpace-constrained panels18,000~25,000
  1. Breaking Capacity Classes
ClasseUltimate Breaking Capacity (terapia intensiva)Applicazione
N142kA@440VStandard commercial buildings
N250kA@690VGeneral industrial distribution
H165kA@440VStandard industrial
H1b80kA@440VAmbienti ad alto cortocircuito
H2100kA@440V / 85kA@690VCentri dati, power plants
  1. Tipi di unità di sgancio & Funzioni
Trip ModelProtezioneComunicazioneApplicazione
MIC2.0L/S/INessunoProtezione di base
MIC5.0L/S/I + GModbus-RTUStandard industry
MIC6.0L/S/I/G + misurazione + loggingModbus/TCP/EthernetSmart distribution
ET2E/ET6EAdvanced settings + monitoraggio remotoMultiple busesAutomation systems
  1. Cross-Brand Equivalent Comparison
  2. Marchi internazionali
SchneiderABB EmaxSiemens 3VA/3WTEquivalenza funzionalePrice Ratio
MT08H1 MIC5.0E1B1250 R630 PR122/P-LSI3VA2 800 H LSIPienamente compatibileABB≈1.2x, Siemens≈1.3x
MT16H1 MIC6.0E2B1600 R800 PR123/P-LSI3WT2 1600 H LSISame mounting dimensionsABB≈1.25x, Siemens≈1.35x
MT32H2 MIC6.0E3H3200 R1600 PR123/P-LSI3WT3 3200 H LSIMain incoming replacementABB≈1.3x, Siemens≈1.4x
NW10H1 4PE1D1000 R500 PR112/P-LSI3VA2 1000 H LSICompact replacementABB≈1.15x, Siemens≈1.25x
  1. Marchi nazionali cinesi (Cost-Effective Alternatives)
SchneiderCHINT NA1Delixi CDW6People Electric DW1Price Ratio
MT08N1 MIC2.0NA1-1000X/3PCDW6-1000/3PDW1-1000/3PDomestic ≈ 60% of Schneider
MT16H1 MIC5.0NA1-1600X/4PCDW6-1600/4PDW1-1600/4PDomestic ≈ 55% of Schneider
MT32H2 MIC6.0NA1-3200X/4PCDW6-3200/4PDW1-3200/4PDomestic ≈ 50% of Schneider
NW16H1 3PNXA-1600/3PCDW3-1600/3PDW1-1600/3PDomestic ≈ 65% of Schneider
  1. Key Selection Parameters
ArticoloSchneiderABBCINTSuggerimento per la selezione
Tensione nominale690V e690V e690V eMatch system voltage
Capacità di interruzioneClass-markedSame classSame classBased on short-circuit calculation
Poli3P/4P (N optional)3P/4P3P/4P4P for three-phase four-wire
MontaggioFixed/WithdrawableFixed/WithdrawableFixed/WithdrawableWithdrawable for critical loads
Control SupplyAC220/380V, DC110/220VStessoStessoMatch control system
ComunicazioneModbus/EthernetProfibus/ModbusModbus optionalRequired for automation
  1. Procurement & Note di sostituzione
  2. Dimensional compatibility: MT series matches ABB Emax E2/E3 and CHINT NA1 for direct replacement
  3. Terminali: Domestic models have lower torque ratings; retorque per manufacturer spec
  4. Trip settings: Recalibrate L/S/I after replacement to ensure selectivity
  5. Accessori: Shunt trip, intervento per sottotensione, ecc., must match or be verified compatible
  6. Cost advantage: Domestic brands cost roughly 50%~65% of Schneider, ideal for budget projects
  7. Recommended Application Scenarios
ScenarioRecommended SchneiderAlternativeMotivo
Factory main incomingMT32H2 MIC6.0CHINT NA1-3200XHigh breaking + smart protection
Commercial buildingMT16H1 MIC5.0Delixi CDW6-1600Affidabile + conveniente
Data centerMT40H2 MIC6.0ABB E3H4000Ultra-high breaking + redundancy
Compact panelNW10H1 4PCHINT NXA-1000Small size + funzioni complete

Prec:

Lascia una risposta

Lasciate un messaggio