Posizionamento del prodotto: SIRIUS Innovation series, Size S0, 3-contattore CA a polo. Designed for start/stop control of 3-phase motor and load, with screw terminals and DIN rail mounting.
✅ Model Breakdown
3RT2: New generation SIRIUS contactor series
024: Codice specifica, AC-3 12A / 5.5kW @400V
1: Built-in auxiliary contacts 1NO + 1NC
UN: Bobina CA
P: 230V CA 50 Hz
00: Morsetti a vite, no additional function modules
📋 Core Technical Parameters
| Articolo | Specifiche |
| Contatti principali | 3P normally open, AC-3 12A; controls 5.5kW motor at 400V |
| Contatti ausiliari | Integrated 1NO + 1NC |
| Tensione della bobina | AC230V 50Hz |
| Dimensioni del telaio | Size S0; Dimension 45×85×97 mm |
| Cablaggio | Morsetti a vite, Montaggio su guida DIN |
| Tensione di isolamento nominale | 690V; Rated Impulse Withstand Voltage 6kV |
| Temperatura operativa | -25℃ ~ +60 ℃ |
| Resistenza meccanica | 10 milioni di operazioni |
| Corrente di breve durata | 110A for 10s |
| Classe di protezione | IP20 (terminals and front face) |
| Codice SA | 85364900 |
🧩 Application Scenarios
Start/stop and reversing control of 3-phase asynchronous motors
Tifosi, pompe dell'acqua, belt conveyors and small machine tool loads
HVAC and automation control cabinet power circuits
🔁 Reference Replacement Models
- Upgrade relation: 3RT1024-1AP00 (vecchio, interrotto) → 3RT2024-1AP00 (successor)
- Same rating with different coil voltage:
3RT2024-1AN20: AC220V 50/60Hz wide-range coil
3RT2024-1BB40: DC24V coil
- Equivalente domestico: Siemens 3RT6024-1AP00 (locally manufactured, parametri elettrici identici)
⚠️ Selection & Note sulla manutenzione
- Per la sostituzione, verify: AC-3 current rating, tensione della bobina, quantity of auxiliary contacts
- Recommended matched thermal overload relay: 3RU2124 series (for 5.5kW motors)
- Accessori opzionali: soppressore di sovratensioni, side-mounted auxiliary contacts, interblocco meccanico
- Second-hand inspection checklist: coil resistance measurement, main contact erosion check, pull-in & release action test
Siemens 3RT2024-1AP00 Full Technical Data
SIRIUS 3RT2, Quadro S0, 3-pole power contactor, terminali a vite, Montaggio su guida DIN
- Contatti principali (Circuito di potenza)
| Articolo | Specifiche |
| Poli | 3P, 3 contatti principali normalmente aperti |
| Corrente operativa nominale Ie (AC-3) | 12A @400V |
| Potenza nominale del motore (AC-3) | 5.5kW for 3-phase motor @400V |
| Rated current for resistive load (AC-1) | 20UN |
| Tensione nominale di isolamento Ui | 690V |
| Tensione nominale di tenuta ad impulso Uimp | 6kV |
| AC-4 rated current | 12.5A @400V |
| Corrente di breve durata | 110UN, 10S |
| Max cross-section of main circuit cable | 10mm簡 |
- Built-in Auxiliary Contacts
Configurazione: 1NO + 1NC (integrato, non-removable)
Portata contatti ausiliari: AC-15 3A / DC-13 0.5A
Max voltage for auxiliary contacts: 400V e
III. Parametri della bobina (Circuito di controllo)
| Articolo | Specifiche |
| Tensione nominale della bobina | AC230V, 50Hz |
| Coil operating voltage range | 0.8 ~ 1.1 × Ue (184V ~ 253V) |
| Apparent power during pull-in | 65VA |
| Apparent power during holding | 6VA |
| Tipo di bobina | Bobina CA |
- Durata di servizio & Frequenza operativa
Vita meccanica: 10,000,000 operazioni
Vita elettrica AC-3: ca. 1,000,000 operazioni
Max operating frequency under AC-3: 1000 cicli/ora
Max operating frequency under AC-4: 300 cicli/ora
- Ambientale, Dimensional & Dati meccanici
Dimensioni del telaio: Size S0
Dimensione complessiva: W45mm × H85mm × D97mm
Peso netto: ca. 0.405kg
Montaggio: 35Guida DIN da mm, or plate mounting via screws
Terminali: Morsetti a vite
Temperatura ambiente operativa: -25℃ ~ +60 ℃ (gabinetto interno)
Temperatura di conservazione: -55℃ ~ +80 ℃
Classe di protezione: IP20 (front face and terminals)
- Standard & Certificazioni
Compliance standard: CEI 60947-4-1 / GB 14048.5
Certificazioni: CCC, CE, UL
Codice SA: 85364900
VII. Definizione del modello
3RT2: New generation SIRIUS contactor series
024: Codice specifica, AC-3 12A, Dimensione S0
1: Built-in 1NO+1NC auxiliary contacts
UN: Bobina CA
P: AC230V 50Hz
00: Morsetti a vite, no built-in surge suppression
VIII. Matching Selection Reference
- Relè termico: 3RU2124 (matched for 5.5kW motors)
- Accessori: side-mounted auxiliary contacts, RC surge absorber, mechanical interlock module
- Locally manufactured equivalent model: 3RT6024-1AP00, parametri elettrici completamente identici
Siemens 3RT2024-1AP00|Application Fields & Load Types
Specification baseline: Quadro S0, AC-3 12A / 5.5kW@400V, 3-contattore CA a polo. Primarily used for direct-on-line (DOL) starting of 3-phase motors; also suitable for AC-1 resistive loads. Integrated 1NO+1NC auxiliary contacts for PLC feedback and interlock circuits.
🏭 1. General Machinery Manufacturing (Più comune)
Piccole macchine utensili: pompe di raffreddamento, pompe di lubrificazione, chip removal motors
Attrezzature di trasporto: trasportatori a nastro, linee a rulli, ascensori
Pneumatic systems: start/stop for small piston air compressor motors
Attrezzature per l'imballaggio: stretch wrappers, sigillanti di casse, small stirring motors
Lavorazione del legno & macchinari per la plastica: trituratori, auxiliary extruder motors, tifosi
🌬️ 2. HVAC & Automazione degli edifici
Ventilatori per unità di trattamento aria, pompe dell'acqua di raffreddamento, condensate pumps for central air conditioning
Small compressors, exhaust fans and fresh air fans of air-cooled / water-cooled units
Building control cabinets, fire smoke exhaust fans (with thermal relay protection)
Carichi resistivi: electric heating elements, commercial lighting circuits (AC-1, max.20A)
🥤 3. Cibo, Bevanda & Industria farmaceutica
Wash pumps, agitator tanks, transfer pumps, small drive motors for filling lines
Fans and pump sets for CIP cleaning systems
Fans and circulating water pumps in cold storage and clean rooms
Vantaggi: Wide temperature range -25~+60℃, CCC/CE/UL certifications, suitable for clean control cabinets
💧 4. Trattamento delle acque & Water Supply/Drainage
Small sewage pumps, clean water pumps, chemical dosing agitator motors
Rainwater harvesting, greywater systems, filter drive motors
Local pump station control cabinets, PLC remote start-stop + operation feedback (via built-in auxiliary contacts)
🚗 5. Automobilistico & Component Automation
Tooling fixtures, roller conveyors at workstations, workstation cooling fans
Exhaust fans in spray booths, small hydraulic station motors
Motor start-stop control for test benches
⚙️ 6. Altre applicazioni industriali
- MCC Motor Control Centre: 5.5kW motor circuits in drawer units; forms complete motor protection unit together with circuit breaker and thermal relay
- Bypass VFD: Bypass switching for small variable frequency drives (Nota: Frequent switching is not recommended)
- Small hydraulic stations: Start-stop control for hydraulic oil pump motors
- Solare / energy storage auxiliary: Cabinet cooling fans and circulating pump control
✅ Applicable Load Types
- AC-3: 3-motore asincrono di fase (5.5kW@400V), Diretto in linea (DOL) di partenza (primary use)
- AC-1: Carichi resistivi, electric heating, incandescent lamp groups, max.20A
- AC-4: Motor inching and forward/reverse rotation (Nota: limited operating frequency, max.300 cycles/hour)
❌ Non-suitable Scenarios
Motors rated >5.5kW
Heavy frequent inching and heavy shock duty (long-term high frequency under AC-4)
Capacitor reactive power compensation (special 3RT26 capacitor contactor required; this model cannot be substituted)
DC main circuit loads (this is an AC contactor)
💡 Selection Key Points
Built-in 1NO+1NC mirror auxiliary contacts for running feedback, fault interlocking and safety circuits, ideal for PLC automation control
Montaggio su guida DIN, compact width (45mm), suitable for dense cabinet layout
Siemens 3RT2024-1AP00|Cross-Brand Equivalent Comparison Table
Baseline specification: 3P, AC-3 12A, 5.5kW@400V, AC230V 50Hz coil, built-in 1NO+1NC auxiliary contacts, terminali a vite, Guida DIN
⚠️ Nota: Electrically equivalent replacement; dimensioni complessive, cutouts and accessories may not be fully compatible. Verify mounting dimensions and auxiliary contact configuration before cabinet retrofit.
| Marca | Modello equivalente | Osservazioni |
| Siemens (Stessa marca) | 3RT6024-1AP00 | SIRIO domestico, fully identical parameters, local replacement; obsolete predecessor: 3RT1024-1AP00 |
| Schneider Electric | LC1D12P7 (TeSys Deca) | 3P AC-3 12A, Bobina AC230V, built-in 1NO+1NC; same 45mm width, most popular direct replacement |
| ABB | AF12-30-11-13 (Serie AF) | 3P 12A, Bobina AC230V, built-in 1NO+1NC; AF wide-voltage coil, elevata versatilità |
| Rockwell AB | 100-C12*11, coil code A0 (AC230V) | 100Serie C, 3P 12A, integrated 1NO+1NC auxiliary contacts |
| OMRON | CJX2-1211 AC230V (Omron contactor) | 3P 12A, 1NA+1NC, terminali a vite |
| LOVATO | BF1211A230 | BF series, 3P AC-3 12A, AC230V, 1NA+1NC |
| CHNT | NXC-12 11 CA 220/230 V | Mainstream domestic model, 3P 12A, 1NA+1NC, conveniente |
| DELIXI | CJX2s-1211 AC230V | CJX2s series, 12UN, 1NA+1NC |
✅ Key Notes for Cross-brand Replacement (Engineering)
- Contatti ausiliari: The reference model has built-in 1NO+1NC. Many economical models only have 1NO (per esempio. LC1N1210), cannot be directly replaced due to missing NC feedback contact. Must select suffix 1211 (1NA+1NC).
- Tensione della bobina: Baseline AC230V 50Hz. Distinguish:
M7=AC220V 50/60Hz; P7=AC230V 50Hz (fully matches coil of this model)
- Dimensioni di montaggio: Siemens S0 frame width 45mm; Schneider LC1D12, ABB AF12 also 45mm width, directly mountable on DIN rail, cutout generally compatible. Depth differs; verify depth if cabinet space is limited.
- Matched Thermal Relay: Thermal relay model must be changed when switching brand. Contactors and thermal relays from different brands cannot snap-fit together, separate mounting required.
- Interblocco meccanico & Accessori: Cross-brand accessories not interchangeable. Reversing interlock modules and side-mounted auxiliary contacts cannot be mixed.
❗ Quick Selection Recommendation
Direct replacement for project, elevata compatibilità: Schneider LC1D12P7
Cost reduction with domestic product: CHNT NXC-12 11 AC230V
Overseas project, wide voltage requirement: ABB AF12-30-11-13
Siemens 3RT2024-1AP00 (S0 Frame) Dimensioni di montaggio
Unità: mm
Dimensioni complessive
Larghezza L:45
Altezza H:85
Profondità D:97 (from DIN rail backplate to front of terminals)
Metodi di montaggio
- Montaggio su guida DIN: Guida DIN standard da 35 mm (IL TUO 60715), clip-on installation
- Fissaggio a vite: Can also be plate-mounted directly on backplate (without rail)
Orientamento di montaggio: ±180° rotation on vertical plane; ±22.5° tilt forward/backward allowed
Spazio libero nell'armadio per la dissipazione del calore
Side-by-side installation: 0gioco di mm (can be mounted tightly together)
Minimum top, bottom and front clearance: 10mm
Clearance to earthed metal parts: ≥6mm laterally, ≥10mm top/bottom/front
⚠️ Dimension change after adding accessories (Important for cabinet cutout design)
- Front-mounted auxiliary contact block: Larghezza & height unchanged, depth increases by 44mm
- Side-mounted auxiliary contacts: Altezza & profondità invariata, width increases
This unit has built-in 1NO+1NC auxiliary contacts; dimension remains 45×85×97 without extra accessories.
Peso
Peso netto: 0.405kg
Riferimento sostitutivo
Schneider LC1D12P7 also has 45mm width, compatible DIN rail position; but depth varies slightly. Double-check depth for cabinet retrofit with limited depth.
Contattore,interruttore automatico,sensore,Codificatore,PLC,Convertitore
























NH42-63-318x560.png)