The following are the technical parameters of the Siemens 6ES7231-5QA30-0XB0 module (based on Siemens official information): Module Model 6ES7231-5QA30-0XB06ES7142-5AF00-0BA0 Siemens SIMATIC S7-1200 Analog Input Module, 8-channel Thermocouple InputSiemens 1FL6034-2AF21-1LH1 Servo Motor Technical Parameter TableSiemens converter 6SE6440-2UD42-0GA1 Parameter Description Module Type Analog Input Module (AI Module), supporting thermocouple signal input. Number of Channels 8 analog input channels (dedicated ...

  • Dettagli del prodotto

The following are the technical parameters of the Siemens 6ES7231-5QA30-0XB0 module (based on Siemens official information):

Module Model

6ES7231-5QA30-0XB06ES7142-5AF00-0BA0 Siemens

SIMATIC S7-1200 Analog Input Module, 8-channel Thermocouple InputSiemens 1FL6034-2AF21-1LH1 Servo Motor

Technical Parameter TableSiemens converter 6SE6440-2UD42-0GA1

ParametroDescription
Module TypeAnalog Input Module (AI Module), supporting thermocouple signal input.
Number of Channels8 analog input channels (dedicated for thermocouples).
Input Signal TypeSupports various thermocouple types:
– B, E, J, K, l, N, R, S, T, PL200, Ni1000, ecc.
Resolution16 bits (signed integer, including the sign bit).
AccuracyTypical error: ±0.1% (for Type K thermocouple at 25°C);
Cold junction compensation error: ±0.5°C.
Input RangeDepends on the thermocouple type (Per esempio: for Type K, it is -200°C ~ +1350°C; for Type J, it is -210°C ~ +1200°C).
Open Circuit DetectionSupports channel-level open circuit detection, and outputs the upper limit value when there is an open circuit (can be configured as upper/lower overflow or a specified value).
Cold Junction CompensationThe module has a built-in temperature sensor and automatically performs cold junction compensation (compensation range: 0°C ~ 55°C).
Power Supply VoltageCC 24 V (powered through the PLC backplane bus, no additional power module is required).
Current ConsumptionApproximately 80mA (powered from the backplane bus).
Protection LevelIP20 (needs to be installed in the control cabinet, in line with industrial environment standards).
Metodo di installazioneDIN rail installation (35mm), supports horizontal or vertical installation, and is directly connected to the S7-1200 host.
Interfaccia di comunicazioneCommunicates with the CPU through the S7-1200 backplane bus, supporting real-time data exchange.
Configuration ToolTIA Portal V13 and above versions. The thermocouple type and input range need to be configured in the hardware configuration.
Diagnostic FunctionChannel-level fault diagnosis (open circuit, out-of-limit, configuration error);
LED status indicator lights (power supply, fault).
Condizioni ambientali– Temperatura operativa: 0°C ~ 60°C;
Storage temperature: -40°C ~ +85°C;
Relative humidity: 5% ~ 95% (nessuna condensa).
Dimensioni (W×H×D)35mm × 100mm × 110mm (compact design, saving control cabinet space).
PesoApproximately 190g.

Main FunctionsSiemens V20 Inverter 15KW of Model 6SL3210-5BE31-5UV0

  1. High-precision Measurement: 16-bit resolution supports high-precision temperature collection, suitable for industrial temperature monitoring scenarios (such as heating furnaces, pipeline temperature measurement).Chint converters (NVF2G-18.5/TS4 or NVF2G-18.5/PS4
  2. Compatibility with Multiple Types: Supports mainstream thermocouple types, no additional signal conversion module is required, simplifying the system design.
  3. Intelligent Diagnosis: Real-time detection of faults such as open circuits and signal out-of-limit, and feedback of status through LED and diagnostic buffer.
  4. Quick Configuration: Intuitively configure input parameters through TIA Portal, and support firmware update to expand functions.

Scenari applicativiAB Inverter 25B-D043N114

Industrial automation temperature control systems (such as chemical industry, metallurgy, HVAC).

Equipment status monitoring (motor temperature, bearing temperature, ecc.).

Used in conjunction with S7-1200 PLC to build small and medium-sized measurement and control systems.

For detailed manuals, you can visit the Siemens official website, search for 6ES7231-5QA30-0XB0 to download technical documents or E-Catalog.