Marca: Telemeccanica Sensori (formerly Schneider OsiSense XM series, now part of YAGEO)
Tipo: Diaphragm type, adjustable differential pressure switch with dual setpoints, local scale indicator, 1 contatto di scambio (1CO)
✅ Pressure Specifications
Rising pressure setting range: 0.7~10 bar
Falling pressure reset range: 0.13~9.15 bar
Minimum differential: 0.57 sbarra; maximum differential: 7.5 sbarra
Instantaneous overload pressure: 22.5 sbarra; continuous maximum working pressure: 12.5 sbarra
Pressione di scoppio: 45 sbarra
Sensing element: Diaframma; wetted materials: FPM/FKM fluoroelastomer + zinc alloy
Supporti compatibili: Aria compressa, acqua pulita, olio idraulico; temperatura media: 0~70 ℃
✅ Process & Collegamento elettrico
Connessione al processo: Filettatura interna G1/4 (ISO228)
Electrical entry: Pressacavo Pg13,5, cable OD 9–13 mm; terminali a vite, wire size 0.5~2.5 mm²
Contatto: 1CO (13-14-11-12) silver contact, azione a scatto
Valutazione dei contatti: AC-15 120V/3A; 240V/1,5 A; DC-13 250V/0.1A
Tensione di isolamento Ui: 500V(CEI); tensione di tenuta ad impulso Uimp: 6 kV
Classe di protezione: IP66
Ripetibilità: ±2%; frequenza di commutazione massima: 120 cicli/min
Vita utile meccanica: 5 milioni di cicli
Temperatura ambiente: -25~70 ℃; temperatura di conservazione: -40~70 ℃
✅ Dimensioni & Peso
Larghezza 35 mm × Altezza 113 mm × Profondità 75 mm; peso netto 0.705 kg; montaggio in qualsiasi orientamento
✅Approvazioni & Standard
CE, UL508, CSA, IEC60947-5-1; approvazione della classificazione marina; origine: Repubblica Ceca / Marocco; garanzia: 18 mesi
✅ Applicazioni tipiche
Compressori d'aria, centraline idrauliche, pompe di approvvigionamento idrico, sistemi di lubrificazione, HVAC, avvio/arresto generale della pressione industriale, protezione interblocco alta/bassa pressione
✅ Riferimento di sostituzione tra serie
XMLB condivide la stessa piattaforma con XMLA/XMLC/XMLD. Si prega di distinguere gli intervalli di pressione (0.25/10/16/25 sbarra), versioni con quantità di contatti e indicatore. Modelli precedenti XM2JM, XMJ può essere sostituito con XMLB.
Manuale di installazione del pressostato Telemecanique XMLB010A2S11
Serie applicabili: XMLA / XMLB / XMLC / Pressostati elettromeccanici XMLD della stessa piattaforma. Modello: XMLB010A2S11, 10 intervallo di barre, differenziale regolabile, 1Contatto di commutazione CO, Filettatura interna G1/4, Ghiandola Pg13.5, IP66
⚠️ Avvertenze precauzionali di sicurezza (Leggi prima)
- NON smontare, collegare o regolare sotto pressione o sotto tensione. Depressurizzare il sistema e isolare l'alimentazione di controllo prima di qualsiasi intervento.
- Mezzi approvati: Aria compressa, acqua pulita, olio idraulico standard. Sono vietati mezzi fortemente corrosivi o mezzi ad alta temperatura (temperatura media massima 70 ℃).
- La pressione non deve superare il sovraccarico istantaneo 22.5 bar o pressione di scoppio 45 sbarra. La sovrapressione danneggerà permanentemente la membrana e annullerà la funzione di protezione.
- I contatti sono progettati solo per circuiti di controllo. Non commutare direttamente l'alimentazione del motore principale. AC-15 120 V 3 A / 240V 1,5 A, CC-13 250 V 0,1 A.
- Grado di protezione IP66. Per installazione esterna, evitare la luce solare diretta e forti spruzzi continui. Stringere completamente il pressacavo per sigillarlo.
- Messa in servizio, la taratura e la manutenzione devono essere eseguite da personale qualificato pneumatico/idraulico ed elettrico a bassa tensione.
- Ispezione del disimballaggio
Verifica modello: XMLB010A2S11
Controllare l'alloggiamento e la filettatura per eventuali crepe o danni; verificare che la piastra della bilancia sia intatta, premistoppa e rondella di tenuta in dotazione
Accessori: Solo unità, dotato di pressacavo Pg13,5; nessun adattatore incluso
Targhetta con controllo incrociato: 0.7~Intervallo di 10 bar, 1Contatto CO, Filettatura di processo interna G1/4 ISO228
- Installazione meccanica
2.1 Requisiti di montaggio
Orientamento di montaggio: Qualsiasi posizione (XMLB non ha requisiti verticali obbligatori). Dai priorità alla facile visibilità della bilancia.
Tenere lontano da fonti di calore elevato e forti vibrazioni (vibrazioni eccessive provocano falsi interventi e riducono la durata).
Si consiglia di montare una valvola di isolamento + valvola di drenaggio nel punto di presa per future tarature e sostituzioni senza l'arresto completo del sistema.
Punto di presa: Prendere pressione dalla parete laterale dei tubi. Evita i punti alti (accumulo di aria) e punti bassi (accumulo di sedimenti).
2.2 Connessione filettata (G1/4 BSP interno)
- Pulire la filettatura maschio, rimuovere bave e detriti metallici per impedire l'ingresso di particelle nella camera della membrana.
- Sigillatura: Utilizzare il nastro in PTFE solo sulla filettatura maschio. Non spingere i residui di nastro nella filettatura interna dell'interruttore poiché i detriti potrebbero inceppare il diaframma.
- Serraggio: Utilizzare una chiave solo sulla base di processo esagonale inferiore. Non bloccare mai l'alloggiamento in plastica: ciò danneggerebbe il meccanismo interno.
- Serrare moderatamente finché non è a tenuta; non forzare il serraggio eccessivo.
Accessorio opzionale: Adattatore da G1/4 a NPT1/4 per sistemi di tubazioni NPT.
2.3 Raccomandazioni sulle tubazioni
Mantenere il tubo d'impulso corto e con un diametro largo per ridurre il ritardo nella risposta. Un tubo lungo può causare una risposta lenta e vibrazioni.
Installare un prefiltro per fluidi con solidi per proteggere il diaframma in fluoroelastomero FKM.
Scaricare i sistemi pieni d'acqua in ambienti freddi per evitare il congelamento; l'espansione del ghiaccio rompe il diaframma.
- Cablaggio elettrico
3.1 Specifiche del cavo
Diametro esterno del cavo: 9~13 mm (corrisponde alla ghiandola Pg13.5)
Sezione del conduttore: 0.5~2,5 mm² (AWG20~AWG14); per i conduttori a trefoli si consigliano puntali.
3.2 Definizione del terminale (1Contatto pulito CO)
| terminale | Definizione | Descrizione |
| 11 | COM | Comune |
| 12 | NC | Normalmente chiuso: Conduce al di sotto della pressione impostata, si apre alla pressione di intervento |
| 14 | NO | Normalmente aperto: Chiude alla pressione di intervento, si apre a bassa pressione |
Marcatura 13: Alcune versioni segnano 13 alongside 14 for the same NO circuit; follow housing marking.
3.3 Procedura di cablaggio
- Isolate power, remove top cover screws and open the lid.
- Loosen Pg13.5 gland nut, feed cable through and strip to suitable length.
- Insert wires into terminals and tighten screws securely to avoid loose connections.
- Route cables clear of the internal spring adjustment assembly. Refit cover and tighten screws evenly.
- Tighten gland and compress rubber seal to maintain IP66 integrity. Poor gland sealing causes water ingress and failure.
Wiring note: This is a passive dry contact. No supply voltage is carried by the switch. PLC or relay control power must be supplied externally.
- Pressure Setting & Calibrazione (XMLB dual setpoint: trip point + differenziale)
XMLB operation: Two adjustment screws: high setpoint (trip pressure) and differential (isteresi). The low reset point is not independently adjusted.
Gamma di specifiche per questo modello:
Aumento della pressione di intervento: 0.7~10 bar
Pressione di ripristino in calo: 0.13~9.15 bar
Minimum differential 0.57 sbarra, maximum differential 7.5 sbarra
Passaggi di calibrazione
- Depressurizzare completamente la linea.
- Aprire il coperchio scala frontale per accedere alle due viti di regolazione con scala graduata.
- Collegare un manometro di riferimento (precisione ≥0,5 classe). La scala integrata serve solo per l'impostazione approssimativa.
- Aumentare lentamente la pressione monitorando il manometro di riferimento:
Vite di regolazione principale: Imposta la pressione di intervento. A questa pressione, lo stato del contatto si inverte (NO chiude, Si apre il NC).
Vite differenziale: Imposta l'intervallo di pressione tra lo scatto e il ripristino. Un differenziale maggiore significa una maggiore caduta di pressione prima del ripristino.
- Aumentare e abbassare la pressione 2-3 volte per confermare un viaggio stabile e reimpostare i punti senza deriva.
- Rimontare il coperchio protettivo dopo l'impostazione per evitare regolazioni accidentali. Registrare i valori e applicare l'etichetta identificativa.
✅ Esempio tipico (avvio-arresto della pompa):
Inizia alle 3 sbarra, fermati a 5 bar → differenziale = 2 sbarra. La pompa si ferma a 5 sbarra, riparte alle 3 sbarra.
Nota: La scala incorporata è approssimativa. Le applicazioni di interblocco di sicurezza devono essere calibrate rispetto a un calibro di riferimento certificato; precisione ±2%.
- Verifica della messa in servizio
- Confermare l'assenza di perdite, cablaggio sicuro e tenuta dell'alloggiamento intatta.
- Aumentare lentamente la pressione attraverso il campo di lavoro e verificare che la commutazione dei contatti corrisponda alle impostazioni.
- Completare più cicli per verificare l'assenza di vibrazioni o cicli rapidi.
- Verificare che il carico dei contatti rimanga entro i limiti nominali; montare una protezione con fusibile per i circuiti di controllo.
- Documentazione: trip pressure, ripristinare la pressione, media, temperatura ambiente e data di calibrazione.
- Manutenzione
- Ispezione di routine: Perdita, danni al cavo, Ingresso di acqua nel premistoppa e corrosione dell'alloggiamento.
- Intervallo di calibrazione: 6–12 mesi per il compressore d'aria standard / servizio pompa acqua; calibrazione trimestrale per il servizio di interblocco di sicurezza.
- Pulizia: Pulire l'alloggiamento solo esternamente. NON smontare la camera di processo. La rimozione del diaframma distrugge la tenuta e la precisione.
- Arresto a lungo termine: Depressurizzare e svuotare la camera. Scaricare i circuiti dell'acqua per prevenire la corrosione e il congelamento.
- Vita meccanica: 5 milioni di cicli. Sostituire a fine vita.
- Tabella per la risoluzione dei problemi
| Sintomo | Probabile causa | Rimedio |
| L'interruttore non si attiva alla pressione impostata | Membrana inceppata da detriti; differenziale impostato troppo grande; cablaggio rotto | Depressurizzare, ispezionare o sostituire l'unità; resettare il differenziale; controllare il cablaggio |
| Ciclaggio rapido / chiacchierando | Differenziale impostato troppo piccolo; pulsazione di pressione nelle tubazioni | Aumentare il differenziale; montare lo ammortizzatore o l'accumulatore |
| La pressione di intervento esce dalla tolleranza | Shock da sovrapressione; invecchiamento del diaframma; vibrazioni eccessive | Sostituire l'interruttore; aggiungere smorzamento delle vibrazioni e protezione contro le sovratensioni |
| Ingresso di acqua / corrosione interna | Ghiandola allentata, guarnizione del coperchio mancante | Richiudere il gruppo; sostituire l'unità se le parti di tenuta sono danneggiate |
| Perdita nella filettatura | Nastro in PTFE applicato in modo errato; base incrinata a causa del serraggio eccessivo | Risigillare il filo; sostituire l'unità se la base è rotta |
Telemecanique XMLB Series Electromechanical Pressure Switch – Fault Troubleshooting Guide
For XMLB010A2S11, diaphragm type, differenziale regolabile, contatto secco. Always depressurize and isolate power before troubleshooting; test contacts with multimeter continuity mode.
| Sintomo di guasto | Causa ultima | Passaggi di ispezione | Azione correttiva |
| No switching when pressure reaches setpoint | 1. Tapping port / impulse line blocked by sludge, scale or debris2. Diaphragm jammed or ruptured3. Setpoint higher than system working pressure4. Internal adjustment thread stripped or spring seized5. Failed microswitch | 1. Depressurize and inspect tapping port2. Use reference gauge to confirm actual system pressure3. Test COM-NO / COM-NC continuity with multimeter | 1. Clear impulse line and add inlet filter2. Reduce trip setpoint and lock screw3. Replace complete unit if diaphragm or internal mechanism is damaged (diaphragm chamber not serviceable on site) |
| Switch fails to reset below reset pressure, contact stays latched | 1. Excessive differential setting2. Contact welded / stuck (inductive load without surge suppression)3. Jammed mechanical linkage or fatigued spring4. Trapped pressure in piping, no pressure relief | 1. Test continuity after full depressurization2. Check differential scale and verify relief valve operation | 1. Reduce differential within published range2. Sostituire l'interruttore; add intermediate relay and RC snubber for inductive loads3. Clear piping to enable free pressure relief |
| Ciclaggio rapido / chiacchierando | 1. Differenziale (isteresi) set too low2. Pulsating pressure from pump / compressor3. Insufficient accumulator volume or failed bladder4. Tapping point located in turbulent flow zone | 1. Observe pressure gauge for small fluctuations2. Check current differential setting | 1. Aumentare il differenziale (XMLB max differential 7.5 sbarra)2. Fit pressure snubber or buffer tank on impulse line3. Riposizionare il punto di presa sulla parete laterale del tubo diritto |
| Pressione di intervento incoerente, alla deriva tra i cicli | 1. Affaticamento della molla dovuto a ripetuti shock di pressione2. Deformazione permanente della membrana dovuta a sovrapressione3. Temperature estreme o vibrazioni continue4. Affidarsi solo alla bilancia integrata senza calibrazione del manometro di riferimento | 1. Confronta i punti di intervento/reset su più cicli rispetto al manometro certificato2. Controllare la cronologia dei superamenti 22.5 sovraccarico istantaneo della barra | 1. Ricalibrare e registrare i valori con il misuratore di riferimento2. Aggiungi staffa antivibrante e schermatura termica3. Sostituire l'unità se la deriva persiste |
| Perdita intermittente del segnale, contatto instabile | 1. Terminali allentati o conduttori ossidati2. Bruciato / contatti del microinterruttore carbonizzati3. Ingresso di acqua e corrosione dei terminali a causa del premistoppa allentato4. Cablaggio interno allentato a causa delle vibrazioni | 1. Isolate power, aprire il coperchio e serrare nuovamente i terminali2. Eseguire il ciclo e testare ripetutamente la continuità | 1. Stringere nuovamente i terminali, pulire o sostituire i conduttori ossidati2. Stringere il pressacavo Pg13,5 e controllare la tenuta per IP663. Sostituire l'unità se i contatti sono bruciati |
| Perdita di fluido dal corpo dell'interruttore | 1. Nastro in PTFE intrappolato all'interno della filettatura e del diaframma di incisione2. Invecchiamento della membrana / incompatibilità con il fluido di processo3. Danni da congelamento, sovratemperatura o sovrapressione4. Base incrinata a causa di una chiave sull'alloggiamento in plastica | 1. Identificare la posizione della perdita: giunto filettato o cucitura dell'alloggiamento2. Verificare che la pressione e la temperatura del processo rientrino nei valori nominali | 1. Richiudere correttamente, applicare il nastro solo sulla filettatura maschio2. Seleziona la variante del materiale a contatto con il fluido compatibile con media3. Sostituire l'unità se la base o il diaframma sono danneggiati |
| Ingresso d'acqua e ruggine interna | 1. Guarnizione del premistoppa mancante o allentata2. Guarnizione coperchio invecchiata, viti del coperchio serrate in modo non uniforme3. Installazione da esterno con spruzzo diretto / Esposizione ai raggi UV | 1. Aprire il coperchio e verificare la presenza di acqua stagnante o ossidazione | 1. Sostituire la guarnizione, serrare uniformemente le viti del coperchio e comprimere la guarnizione del premistoppa2. Montare una protezione dalle intemperie per uso esterno |
| Burnout ripetuto del contatto all'accensione | 1. Commutazione diretta dei motori / contattori, superamento della classificazione dei contattiClassificazione dei contatti XMLB: AC-15 240 V 1,5 A, non per carichi ad alta potenza2. Arco induttivo non soppresso | 1. Controllare la corrente di carico e separare il circuito di controllo dal circuito di alimentazione | 1. Utilizzare il pressostato solo per pilotare un relè intermedio; il relè commuta il carico2. Montare lo smorzatore RC sulle bobine induttive |
✅ Sequenza di risoluzione dei problemi standard
- Controllo del processo: Confermare la pressione, i mezzi e la temperatura rientrano nei valori nominali; verificare che le valvole di isolamento e di sicurezza siano aperte e che la linea di impulso sia libera
- Controllo meccanico: Perdita, vibrazione, posizione di montaggio e di maschiatura
- Controllo del punto di riferimento: Verificare viaggio e differenziale con manometro di riferimento certificato
- Controllo elettrico: Isolate power, testare la continuità del contatto pulito, controllare il cablaggio e la tenuta
- Decisione finale: Sostituire l'unità completa se il diaframma, la molla o il microinterruttore non funzionano. Per XMLB non sono disponibili parti interne di ricambio.
✅ Linee guida preventive
- Installare il prefiltro per i fluidi sporchi per proteggere il diaframma
- Calibrazione trimestrale per i circuiti di interblocco di sicurezza; 6–12 mesi per compressore standard / servizio pompa acqua
- Non applicare mai la forza della chiave sull'alloggiamento in plastica; afferrare solo la base esagonale
- Utilizzare l'isolamento del relè intermedio per carichi induttivi per prolungare la durata dei contatti
- Confermare la compatibilità del materiale bagnato: L'XMLB standard utilizza il fluoroelastomero FKM; versioni speciali richieste per fluidi aggressivi
Telemeccanica Nautilus / Panoramica della serie di pressostati elettromeccanici OsiSense XM
Nota: XMLA / XMLB / XMLC / XMLD è l'attuale diaframma principale / pressostati e vacuostati a pistone. Serie XM precedente (XMJ, XMG, XM2JM, XMP, FYG) sono interrotti e solo per riferimento incrociato. Connessione standard: Filettatura interna ISO228 G1/4, passive dry contact, control circuit duty, IP66
Regola di codifica del modello (XMLB010A2S11 example):
XML [Serie] [Allineare] [Materiale bagnato] [Contatto / Meccanismo] [Electrical Entry] [Versione]
S11 = Pg13.5 cable gland, terminali a vite (XMLB010A2S11); S12=M20 gland; C11=DIN43650 connector
Confronto di serie
| Serie | Contatti | Differenziale | Caratteristica fondamentale | Uso tipico |
| XMLA | 1CO | Fixed differential | Single setpoint, fixed hysteresis, conveniente | Compressori d'aria, simple alarm, single threshold protection |
| XMLB | 1CO | Adjustable differential | Cambio singolo, adjustable trip+reset, scale plate (il tuo modello) | Pump start-stop, compressor pressure regulation, lubrificazione & sistemi idraulici |
| XMLC | 2CO | Adjustable differential | Two independent changeover contacts, dual adjustable setpoints | Separate low-pressure warning + high-pressure shutdown, interblocco, pump/fan sequencing |
| XMLD | 2CO | Fixed differential | Dual independent switch elements, each with fixed hysteresis | Two independent fixed pressure thresholds, interblocco di sicurezza |
| XMLAM / XMLBM | Vuoto | Fisso / Regolabile | Negative pressure vacuum switch, -1…0bar | Vacuum handling, suction lines |
- XMLA (Fixed Differential, 1CO) Elenco dei modelli
| Modello | Allineare (sbarra) | Osservazioni |
| XMLA002A2S11 | 0.25~2.5 | Low pressure air / acqua |
| XMLA004A2S11 | 0.4~4 | Approvvigionamento idrico, HVAC |
| XMLA010A2S11 | 0.7~10 | General air compressor |
| XMLA020A2S11 | 1.2~20 | Idraulico, medium pressure pneumatic |
| XMLA035A2S11 | 2.1~35 | Medium pressure hydraulic |
| XMLA070D2S11 | 4.5~70 | High pressure hydraulic |
| XMLA160D2S11 | 9~160 | High pressure hydraulic |
| XMLA300D2S11 | 16~300 | Heavy-duty hydraulic |
| XMLA500D2S11 | 30~500 | Ultra-high pressure hydraulic |
| XMLAM01V2S11 | -1~0 | Vacuum switch |
- XMLB (Adjustable Differential, 1CO, including XMLB010A2S11)
| Modello | Allineare (sbarra) | Osservazioni |
| XMLB002A2S11 | 0.25~2.5 | Low pressure |
| XMLB004A2S11 | 0.4~4 | HVAC & fornitura d'acqua |
| XMLB010A2S11 | 0.7~10 | Il tuo modello, popular for compressors & pompe |
| XMLB020A2S11 | 1.2~20 | Medium pressure pneumatic / idraulico |
| XMLB035B2S11 | 2.1~35 | Hydraulic power units |
| XMLB070D2S11 | 4.5~70 | High pressure hydraulic |
| XMLB160D2S11 | 9~160 | High pressure hydraulic |
| XMLB300D2S11 | 16~300 | Heavy-duty hydraulic |
| XMLB500D2S11 | 30~500 | Ultra-high pressure hydraulic |
| XMLBM02V2S11 | -1~0 | Adjustable vacuum switch |
- XMLC (Adjustable Differential, 2CO Dual Contacts)
| Modello | Allineare (sbarra) | Osservazioni |
| XMLC004B2S11 | 0.4~4 | Dual signal output |
| XMLC010B2S11 | 0.7~10 | 10 bar dual contact, low / high pressure alarm |
| XMLC020B2S11 | 1.2~20 | Medium pressure dual output |
| XMLC035B2S11 | 2.1~35 | Hydraulic dual interlock |
| XMLC070D2S11 | 4.5~70 | High pressure dual contact |
| XMLC160D2S11 | 9~160 | High pressure hydraulic |
| XMLC300D2S11 | 16~300 | Heavy-duty hydraulic |
| XMLC500D2S11 | 30~500 | Ultra-high pressure hydraulic |
- XMLD (Fixed Differential, 2CO Dual Stage)
| Modello | Allineare (sbarra) | Osservazioni |
| XMLD004B2S11 | 0.4~4 | Dual stage fixed hysteresis |
| XMLD010B2S11 | 0.7~10 | 10 bar dual stage protection |
| XMLD020B2S11 | 1.2~20 | Medium pressure dual stage |
| XMLD035B2S11 | 2.1~35 | Hydraulic safety interlock |
| XMLD070D2S11 | 4.5~70 | High pressure dual stage |
- Modelli legacy fuori produzione (Cross-reference only, non per nuovi progetti)
XMJ: Old single setpoint pressure switch, replaced by XMLA
XMG: Old adjustable differential switch, replaced by XMLB
XM2JM: Sensore ausiliario differenziale fisso semplice
XMP / FYG: Vecchio interruttore a doppio setpoint, sostituito da XMLC
La maggior parte delle serie XM legacy sono state interrotte nel 2002; stock disponibile solo nel mercato dei pezzi di ricambio. Preferisco XMLB/XMLC per la sostituzione.
- Riferimento incrociato del suffisso elettrico (Intercambiabili per la stessa gamma)
S11: Pressacavo Pg13,5, terminali a vite (Norma XMLB010A2S11)
S12: Pressacavo M20×1,5, terminali a vite
C11: Connettore quadrato DIN43650 (stile elettrovalvola)
S13: Versione speciale con custodia estesa
- Definizione del codice del materiale a contatto con il fluido
UN: Fluoroelastomero FKM (generale: aria, acqua pulita, olio idraulico, standard)
B: Gomma nitrilica NBR (olio minerale, non per l'acqua calda)
D: Acciaio inossidabile + FKM (olio idraulico, idraulica a temperatura elevata)
V: Sigillatura sottovuoto
- Guida alla selezione rapida
- Punto di intervento singolo, isteresi fissa → XMLA
- Differenziale start-stop regolabile (pompa / compressore) →XMLB (XMLB010A2S11)
- Due segnali di allarme indipendenti (avviso basso + arresto elevato) →XMLC
- Due soglie indipendenti, nessuna regolazione differenziale richiesta → XMLD
- Pressione di vuoto negativa → XMLAM / XMLBM
Contattore,interruttore automatico,sensore,Codificatore,PLC,Convertitore





















NH42-63-318x560.png)