Servoazionamento Yaskawa SGDH-10DE-OY - Contattore,interruttore automatico,sensore,Codificatore,PLC,Convertitore

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

 Servoazionamento Yaskawa SGDH-10DE-OY - Contattore,interruttore automatico,sensore,Codificatore,PLC,Convertitore

PLC/

Servoazionamento Yaskawa SGDH-10DE-OY

Discontinued legacy 400V class 1kW Yaskawa servo, Sigma II series. The suffix OY stands for custom/special specification, mostly OEM dedicated for original machine builders. Hardware-wise, it is identical to standard SGDH-10DE, but firmware and I/O definitions differ. Direct replacement with standard SGDH-10DE may result in abnormal operation. ✅ Model Breakdown SGDH: Sigma II SERVOPACK servo ...

  • Dettagli del prodotto

Discontinued legacy 400V class 1kW Yaskawa servo, Sigma II series. The suffix OY stands for custom/special specification, mostly OEM dedicated for original machine builders. Hardware-wise, it is identical to standard SGDH-10DE, but firmware and I/O definitions differ. Direct replacement with standard SGDH-10DE may result in abnormal operation.

✅ Scomposizione del modello

SGDH: Sigma II SERVOPACK servo amplifier

10: Rated power 1.0kW

D: 3-phase 400V input (380~480 VCA)

E: Modello standard, supporta 3 control modes: Posizione / Velocità / Coppia

OY: Custom specification code, not standard off-the-shelf version. Features OEM-specific firmware, custom I/O mapping and function masking. Direct swap with non-OY SGDH-10DE carries firmware mismatch risk.

📌 Specifiche elettriche principali

ArticoloSpecifica
Potenza di uscita nominale1kW
Main Circuit Power Supply3-phase AC380~480V, 50/60Hz
Corrente di uscita continua3.7UN (RMS)
Corrente di picco in uscita11.2UN (3 secondi, 300% capacità di sovraccarico)
Built-in Regeneration Capacity14W; external regenerative resistor required for heavy braking
Modalità di controlloPosizione (pulse command), Velocità (±10V analog), Coppia (±10V analog); mode switching available
Pulse InputLine driver: max 500kpps; Open collector: 200kpps
Speed Loop Bandwidth400Hz; supports auto-tuning and inertia identification
ComunicazioneRS232C / RS485; SigmaWin commissioning software; compatible with hand-held operator JUSP-OP05A
Ambiente operativo0~+55°C, montaggio in armadio, no condensation or heavy dust
Dimensioni (L×A×P)55 × 180 × 170 mm

🔌 Terminals & Interfacce

CN1: I/O signals (command pulse, servo enable, allarme, positioning complete, analog signals etc.)

CN2: Encoder feedback port, connects to Sigma II motor encoder

CN3: Commissioning port for handheld operator or PC communication cable

Terminali del circuito principale: L1, L2, L3 (3-ingresso di fase); U/V/W to servomotore; B1/B2/B3 for regenerative resistor

🧩 Compatible Motors (Sigma II 400V Series)

SGMGH / SGMAH / SGMPH 400V 1kW Sigma II motors. Modello tipico:

SGMGH-09D… (1kW 400V motor, most common matching unit)

⚠️ OY firmware binding. Utilizzare come priorità il motore abbinato originale. La sostituzione diretta con SGDH-10DE standard può causare errori di identificazione del motore o mancata corrispondenza della logica I/O.

🛠 Funzioni protettive

Sovracorrente, sovratensione, sottotensione, sovraccarico, surriscaldamento del dissipatore di calore, perdita di fase del circuito principale, velocità eccessiva, disconnessione dell'encoder, errore di parametro, Guasto della CPU, difetto di rigenerazione, protezione in fuga.

⚠ Note chiave per la selezione & Sostituzione

  1. Stato del prodotto: Interrotto da Yaskawa. Le nuove unità sono disponibili solo come stock rimanente; la maggior parte delle unità disponibili sul mercato sono parti di seconda mano usate o ricondizionate.
  2. Opzioni di sostituzione

Sostituzione diretta della stessa serie: SGDH-10DE-OY obbligatorio con suffisso OY. Hardware uguale a SGDH-10DE senza OY, ma firmware/logica differiscono. Eseguire il backup dei parametri e testare gli I/O prima della messa in servizio.

Aggiornamento tra serie: Sigma-V SGDV 400V 1kW (SGDV-5R4D01A); Sigma7 SGD7S. Sono necessari il ricablaggio completo e la rimessa in servizio meccanica; La logica di CN1 è completamente diversa, sostituzione plug-and-play impossibile.

  1. Errori di riparazione comuni: Main circuit alarm, encoder cable break, sovratensione (regeneration resistor failure), parameter alarm, aging electrolytic capacitors (high incidence on old units).
  2. Software di messa in servizio: SigmaWin+ (older version required for Sigma II); handheld operator model: JUSP-OP05A.

📦 Typical Applications

Machine tool feed axes, macchine per l'imballaggio, attrezzature tessili, apparecchiature per semiconduttori, handling manipulators. Many legacy machines (stampa / forming machines) use this OY custom version as OEM standard.

❓ Supplementary Remarks

This is a 400V high-voltage servo. NEVER connect to 220V single/3-phase supply, otherwise power module will be destroyed instantly.

For second-hand units received, perform insulation test and static IGBT measurement before power-on test without load, then connect motor.

HS Code reference: 85011010 (servo drive classification, solo per la dichiarazione doganale, subject to customs broker confirmation).

Yaskawa Sigma II SGDH Alarm Code List (Compatible with SGDH-10DE-OY. Alarm definitions identical for OY custom version; only I/O mapping may differ.)

Nota: A.xx = drive alarm, power stage cut off after trigger; some alarms require power cycle reset. bb is NOT an alarm, it means servo standby with Servo OFF.

Codice allarmeAlarm NameCausa & Risoluzione dei problemi
UN.02Parameter CorruptionEEPROM parameter damage; abnormal power down, backup battery failure. Rimedio: restore factory parameters, rewrite parameters. If alarm persists, main board faulty.
UN.03Main Circuit Encoder FaultEncoder cable broken / shorted, encoder hardware damage; not supported on high-power models.
UN.04Parameter Setting ErrorParameter out of valid range; parameter mismatch after drive replacement (high risk for OY version). Rimedio: verify Pn parameters, reset factory default then reconfigure.
UN.05Motor Combination ErrorMismatch between drive and motor model; wrong encoder type setting. ⚠️OY custom firmware, easy to trigger after motor replacement.
A.10Sovracorrente / Surriscaldamento del dissipatore di caloreIGBT breakdown, motor winding short, power cable earth fault; fan locked, heatsink dust buildup. Most common hardware failure alarm.
A.30Regeneration FaultBroken regenerative resistor, loose B1/B2 terminals; damaged regeneration transistor. Frequently seen on 400V models with frequent emergency stop.
A.32Regeneration OverloadExcessive braking energy; built-in regeneration capacity insufficient. External regenerative resistor required.
A.33Main Circuit Power Wiring Error3-phase input phase loss, wrong L1/L2/L3 wiring, scarso contatto del contattore.
A.40SovratensioneInput voltage too high; regenerative energy during deceleration, failed regeneration circuit; aged main circuit capacitors.
A.41SottotensioneInsufficient 3-phase supply, contactor not closed; missing 24V control supply, fusibile interno bruciato.
A.51Velocità eccessivaMotor actual speed far exceeds command; encoder fault, excessive speed loop gain, wiring interference.
A.71Continuous Overload (High Load)Inceppamento meccanico, bearing damage, carico eccessivo; wrong inertia / reduction ratio, continuous full load.
A.72Continuous Overload (Low Load)Overload under light load; degraded motor insulation, mechanical binding.
A.73Dynamic Brake OverloadFrequent emergency stop causes dynamic brake circuit overheat; not monitored by SGDH-10DE (1kW).
A.74Protezione termica del motoreMotor built-in thermistor triggered, motor overheated.
A.7AEncoder Communication AbnormalityPoor shielding of encoder cable, long cable interference, ossidato / connettore allentato.
A.81Encoder A/B Phase ErrorLoss of encoder A/B signals, errore nella sequenza delle fasi, cavo danneggiato.
A.82Encoder C-phase (Z-phase) ErroreHome Z-phase wire break, encoder fault.
A.83Encoder Battery Alarm (Absolute Motor)Low backup battery voltage for encoder, home position lost.
A.84Encoder Data ErrorData corruption inside absolute encoder.
A.85Encoder DisconnectionCN2 encoder cable cut, bent / retracted pins in connector.
A.86Encoder Power Supply FaultAbnormal 5V output from CN2 port, shorted cable pulls down 5V supply.
A.b1Main Circuit Detection FaultFault in main circuit sampling circuit, power board failure.
A.b2CPU FaultDamaged main control board, program runaway.
A.bFOperator Communication FaultRotto / loose cable for CN3 handheld operator / commissioning line.
A.C1Circuito di sicurezza / HWBB Hardware Base BlockHardware safety circuit open, normally closed emergency stop loop broken.
A.C8Full-closed External Encoder FaultAbnormal signal from external linear scale (only with full-closed option card).
A.CAExternal Encoder A/B Phase ErrorFault in A/B phase signal of full-closed linear scale.
A.CbExternal Encoder Z-phase ErrorFault on home Z-phase signal of linear scale.
A.CCFull-closed Position Deviation ExcessFull closed loop mode; large deviation between linear scale position and motor encoder.
A.d0Position Deviation ExcessPosition error exceeds Pn setting before positioning complete; inceppamento meccanico, missing pulse command.
A.E7RS485 Communication FaultBroken communication cable with host controller, parametri di comunicazione non corrispondenti.

Standby display bb: Not fault, Servo spento, waiting for /S-ON enable signal.

SGDH CN1 (50-pin I/O Connector, Standard Factory Assignment. ⚠️OY custom version pin functions may be redefined by machine OEM!)

Connettore: 50Pin D-Sub. Separate external DC24V required for I/O circuit; input signals active low (NPN).

🔹 Input Signals (Opto-isolated Input)

CN1 Pin No.Signal IDNome del segnaleDescrizione
40/S-ONServo ONAbilitazione servo, ON = motor excitation
41/P-CONProportional Control Switch / Mode SwitchValid under position mode; switch PI / P control, also usable for home latch
42P-OTPositive Over-travel InhibitNormalmente chiuso; open circuit disables forward movement (hard limit)
43N-OTNegative Over-travel InhibitNormalmente chiuso; open circuit disables reverse movement (hard limit)
44/ALM-RSTAlarm ResetFalling edge clears servo alarm
45/P-CLLimite di coppia positivoEnable forward torque limiting
46/N-CLLimite di coppia negativoEnable reverse torque limiting
47+24VINExternal 24V Positive+24V supply for I/O
48SGSegnale GND0V reference for I/O 24V

🔹 Output Signals (Open Collector / Relay Isolated)

CN1 Pin No.Signal IDNome del segnaleDescrizione
31 / 32ALM+ / ALME-Servo Alarm OutputConducts under normal condition; opens when alarm triggered (contatto relè)
29 / 30/S-RDY+ / /S-RDY-Servo prontoConducts when no alarm and main power ready
27 / 28/TGON+ / /TGON-Motor Rotation DetectionConducts when motor speed exceeds threshold
33 / 34PAO / /PAOEncoder A Differential OutputEncoder A phase, can feedback position to host PLC
35 / 36PBO / /PBOEncoder B Differential OutputEncoder B phase
19 / 20PCO / /PCOEncoder Z Differential OutputHome Z pulse
37,38,39ALO1,ALO2,ALO3Alarm Code Binary Output3-bit binary alarm code for PLC reading
21 / 22/COIN+ / /COIN-Positioning CompleteConducts under position mode when position error is within window
23 / 24/V-CMP+ / /V-CMP-Speed Match DetectionConducts under speed mode when motor speed reaches command speed
25 / 26/BK+ / /BK-Brake Control OutputControllo relè freno motore esterno; uscita dopo l'eccitazione del servo

🔹 Relativo al comando degli impulsi (Modalità posizione)

CN1 Pin No.Signal IDNome del segnale
1-2PULS / /PULSComando a impulsi (Driver di linea differenziale)
3-4CARTELLO / /CARTELLOComando di direzione (Driver di linea differenziale)
5-6PULSATELO / SIGN-OImpulso del collettore aperto / Direzione (Comando a terminazione singola)

⚠ Osservazioni importanti (Specifico SGDH-10DE-OY)

  1. Unità personalizzata con suffisso OY: Le funzioni dei pin I/O CN1 possono differire dalla tabella sopra. Mappatura del segnale modificata OEM nel firmware. La sostituzione diretta con SGDH-10DE standard causerà una mancata corrispondenza della logica del PLC: il servo non si abilita, trigger di limite falso.
  2. Utilizzare il cablaggio a impulsi del line driver differenziale per una migliore immunità al rumore; L'impulso single-ended è soggetto a perdita di impulso per cavi lunghi con scarsa schermatura.
  3. I limiti rigidi P-OT/N-OT predefiniti in fabbrica sono normalmente ad anello chiuso. Fare attenzione durante il cortocircuito per la messa in servizio; molti guasti della macchina hanno origine dalla rottura del cablaggio del limite.
  4. L'uscita allarme ALM è un contatto relè passivo. NON collegare direttamente 24 V; serie nel circuito di ingresso del PLC.

Parametri fondamentali supplementari (Sigma II SGDH)

Pn000: Selezione della modalità di controllo (Posizione / Velocità / Coppia)

Pn100: Guadagno dell'anello di posizione

Pn101: Tempo integrale dell'anello di posizione

Pn102: Guadagno dell'anello di velocità

Pn103: Tempo integrale dell'anello di velocità

Pn50A / Pn50B: Assegnazione I/O CN1 (Bloccato sulla versione OY, modificato dall'OEM)

Guida alla riparazione per Yaskawa SGDH-10DE-OY (Sigma II 400 V 1 kW)

⚠ Precauzioni di sicurezza: 400Servo ad alta tensione V. I condensatori del bus CC mantengono l'alta tensione dopo lo spegnimento. Scaricare completamente prima della manutenzione. Scollegare l'alimentazione di controllo L1/L2/L3 e 24 V prima della riparazione. OY è il firmware personalizzato OEM. I parametri e la mappatura I/O differiscono dallo standard SGDH-10DE. Eseguire sempre il backup dei parametri originali prima della riparazione.

Problema comune dell’invecchiamento: Lunga durata. I condensatori elettrolitici degradati sono la causa principale dei guasti nascosti che causano gli allarmi intermittenti.

  1. Standard Troubleshooting Workflow (External first, isolate drive/motor fault)
  2. Read alarm code: Via JUSP-OP05A hand operator or SigmaWin+, record alarm history.
  3. External isolation test (Critical Step)

Disconnect U/V/W motor power cables, keep CN1 24V control power and CN2 encoder cable, power on without load.

Alarm still present at no load: Fault inside servo drive hardware.

No alarm at no load, alarm appears after connecting motor: Fault on motor, power cable or mechanical load.

  1. Power-off static measurement (Diode mode on multimeter)

IGBT test: Measure U/V/W against DC bus P and N. Normal reading shows stable diode voltage drop. Direct short on any phase = IGBT breakdown.

Measure main fuse, charging resistor, ponte raddrizzatore.

Inspect CN1/CN2 connectors for corrosion, bent pins and oxidation.

  1. Disassemble inspection: Check capacitors for bulging / electrolyte leakage, Carbonizzazione del PCB, componenti bruciati, ventilatore sequestrato.
  2. Sostituzione componenti → riparazione → ripristino parametri → test a vuoto → messa in servizio caricata

Nota critica per la versione OY: NON caricare i parametri predefiniti di fabbrica SGDH standard, La logica I/O personalizzata OEM andrà persa e la macchina smetterà di funzionare.

  1. Guasto ad alta frequenza & Soluzioni di riparazione
  2. A.10 Sovracorrente / Surriscaldamento del dissipatore di calore (Più comune)

Sintomo: Allarme immediatamente dopo l'accensione o diversi secondi dopo l'abilitazione del servo

Allarme immediatamente all'accensione: IGBT breakdown, fotoaccoppiatore dell'unità danneggiato, circuito di rilevamento corrente difettoso (7860 Il circuito integrato del sensore di corrente è un difetto noto della serie SGDH).

Riparazione: Sostituire il modulo IGBT, ispezionare il fotoaccoppiatore e i resistori del gate, sostituire i resistori di campionamento difettosi / circuito integrato di rilevamento.

No alarm at no load, l'allarme si verifica dopo aver collegato il motore: Intergiro del motore corto, power cable earth fault, inceppamento meccanico, cuscinetto grippato.

Riparazione: Prova Megger dell'isolamento del motore, sostituire il cavo danneggiato, fissare la rilegatura meccanica.

L'allarme appare dopo aver corso per un periodo: Dust buildup on heatsink, aging / stalled cooling fan and overheat protection.

Riparazione: Clean heatsink dust, replace cooling fan.

  1. A.40 Overvoltage

Sintomo: Alarm triggered during deceleration or shutdown

Causa ultima: Broken regenerative resistor, loose B1/B2 terminals; insufficient built-in regeneration capacity; aged DC bus capacitors; too short deceleration time.

Riparazione:

  1. Measure resistance of B1-B2 regenerative resistor; replace if open or resistance drift.
  2. Test main electrolytic capacitors; replace units with excessive ESR.
  3. Estendere il tempo di decelerazione; install external regenerative resistor for frequent braking applications, modify Pn600/Pn603 parameters.
  4. A.41 Undervoltage

Sintomo: No display on panel or undervoltage alarm after power on

Causa ultima: 3-phase supply phase loss, poor contactor contact; burnt charging resistor; blown main fuse; aged bus capacitors; failed auxiliary switching power supply.

Riparazione:

  1. Measure 3-phase input voltage.
  2. Disassemble and inspect charging resistor (prone to open circuit on old units), main circuit fuse.
  3. Test bus capacitor capacity and replace degraded capacitors.
  4. Repair auxiliary power supply: replace damaged PWM IC and regulator circuit.
  5. A.30 Regeneration Fault

Sintomo: Brake circuit detection error

Causa ultima: Damaged regeneration transistor, loose B1/B2 terminals, faulty 358 op-amp (regeneration detection), damaged optocoupler.

Riparazione: Replace faulty op-amp and optocoupler, inspect brake IGBT, tighten B1/B2 terminals.

  1. A.81/A.82/A.85/A.86 Encoder Alarms

Sintomo: Encoder alarm immediately after enable or intermittent random alarm

Causa ultima: Oxidized / bent pins on CN2 encoder connector; broken / poorly shielded encoder cable; short circuit pulling down 5V encoder supply; guasto hardware dell'encoder.

Riparazione:

  1. Replace shielded encoder cable and re-crimp CN2 connector.
  2. Measure 5V output at CN2. If voltage low, repair on-board 5V supply of drive.
  3. Repair or replace motor encoder if encoder itself is damaged.
  4. UN.02 Parameter Corruption

Sintomo: UN.02 alarm right after power on

Causa ultima: Damaged mainboard EEPROM; uno spegnimento anomalo provoca la perdita dei parametri; batteria di backup guasta sulla scheda madre.

Riparazione: Sostituire il chip EEPROM, scrivere i parametri della versione OY originale. ⚠️ NON caricare i parametri SGDH standard, Si verificherà una mancata corrispondenza della logica I/O.

  1. Nessuna visualizzazione dopo l'accensione, pannello scuro

Causa ultima: Fusibile del circuito di controllo bruciato, alimentatore switching ausiliario danneggiato, resistenza di avvio aperta.

Riparazione: Riparare la scheda di potenza ausiliaria, sostituire il fusibile, resistenza di avvio e chip di alimentazione PWM.

  1. A.71/A.72 Sovraccarico continuo

Sintomo: Allarme di sovraccarico dopo aver funzionato per un periodo

Causa ultima: Carico meccanico eccessivo, legame del cuscinetto; degraded motor insulation; parametro di inerzia errato; impostazione del guadagno eccessivo.

Riparazione: Risolvere problemi meccanici; testare l'isolamento del motore; eseguire nuovamente l'identificazione dell'inerzia e ridurre la posizione / guadagno dell'anello di velocità.

  1. Note di riparazione uniche per SGDH-10DE-OY
  2. Blocco firmware: Il suffisso OY utilizza firmware personalizzato OEM con mappatura I/O CN1 modificata. Dopo aver sostituito la scheda di controllo principale, Il firmware personalizzato OY deve essere aggiornato. La scheda madre SGDH standard montata direttamente causerà guasti alla logica I/O e malfunzionamenti della macchina.
  3. Prima il backup dei parametri: Prima della riparazione, utilizzare SigmaWin+ per leggere online ed eseguire il backup completo di tutti i parametri. Questo è fondamentale per la messa in servizio post-ripristino.
  4. Limitazione della corrispondenza del motore: UN.05 L'errore di combinazione del motore si verifica facilmente dopo la sostituzione dell'azionamento o del motore. Il firmware OY lega il modello di motore abbinato; Non è consentita la sostituzione casuale del motore Sigma II.
  5. Raccomandazione per la sostituzione del condensatore: Questo modello è molto vecchio. Si consiglia la sostituzione completa dei condensatori elettrolitici del circuito principale come manutenzione preventiva, elimina gli allarmi intermittenti relativi alla tensione.
  6. Procedura di test post-riparazione
  7. Prova a vuoto: Scollegare U/V/W, accendere. Il pannello mostra bb senza allarme. Abilitare il servo e verificare che l'uscita pronta S-RDY funzioni correttamente.
  8. Ricollegare il cablaggio: Reconnect encoder cable and motor power cable, jog at low speed and check for vibration or abnormal noise.
  9. Prova di carico: After passing no-load test, applicare gradualmente il carico, monitor bus voltage and current to confirm no alarms.
  10. Restore backed-up parameters, verify limit, uscita allarme, positioning complete and other I/O signals.
  11. Repair Cost Reference

Low-cost repair: Condensatore, fan, fusibile, small signal IC replacement.

High repair cost: Danno al modulo IGBT, mainboard damage, EEPROM firmware corruption. Evaluate second-hand SGDH-10DE-OY spare for replacement.

If OY spare unavailable: Upgrade to SGDV 400V 1kW, perform full rewiring and program commissioning.

Prec:

Prossimo:

Lascia una risposta