Carlo Gavazzi WM12-96.AV5.3.3.S

Carlo Gavazzi WM12-96.AV5.3.3.S

モデルセグメント意味詳細な説明
WM12-96ベースモデル96×96mm panel-mounted three-phase multifunction power indicator with built-in programming keypad
AV5Range Code380/660V L-L / 5(6)そしてAC; VL-N: 185V ~ 460V; VL-L: 320V ~ 800V
3システムタイプ1/2/3-phase system, unbalanced load, with or without neutral line
3Power Supply Type18 to 60VDC power supply, fluctuation range: -15% に +10%
SFunction OptionWith RS485 serial output (X = without this function)
  1. コア仕様パラメータ

2.1 Measurement Performance

パラメータ価値備考
精度クラスCurrent/Voltage: ±0.5% FSAt 25°C±5°C, RH≤60%
力: ±(1% FS + 1 Digit)
頻度: ±0.1%Hz
Measurement MethodTrue RMS (TRMS)Supports distorted sine wave measurement
サンプリングレート1700 samples/s @ 60Hz
Display Refresh Rate700MS
Measured Variablesシステム & phase values: W, Wdmd, var, バージニア州, VAdmd, PF, V, あ, An, Hz3×3-digit LED display, 14mm digit height
Max value indication: Amax, Wdmd max

2.2 電気仕様

パラメータ価値備考
Rated Input現在: 5(6)あCurrent input must be connected via CT; direct connection prohibited
電圧: See model definition for AV5 range
Auxiliary Power18 ~ 60VDC, 消費電力: 4W
過負荷保護Continuous: 1.2×FS
500ms surge: Voltage 2×Un, Current 36A
Dielectric Strength4000VAC / 1分 (Between measurement input and power/RS485)IEC準拠 60664

2.3 物理的な & Environmental Specifications

パラメータ価値備考
パネル寸法96×96mmStandard panel mounting size
侵入保護フロント: IP65 (NEMA4x/12); 端子: IP20
動作温度-10°C ~ +50°CRH<90%, 結露しないこと
保管温度-30°C ~ +60°CRH<90%, 結露しないこと
設置カテゴリーCategory IIIIEC準拠 60664
重さ約. 400g (with packaging)

2.4 Communication Specifications (S Option)

パラメータ価値備考
インターフェースの種類RS422/RS485Multi-point bidirectional communication
Communication Distanceマックス. 1200メートル2-wire or 4-wire connection
アドレス範囲1 ~ 255Keypad configurable
Data Format1 start bit, 8 データビット, no parity, 1 stop bit
ボーレート9600 bit/s
  1. Standard Accessories List
  2. WM12-96.AV5.3.3.S Main Unit (with built-in programming keypad)
  3. Mounting Fasteners (Clips / Screws)
  4. Multilingual Instruction Manual
  5. Terminal Identification Labels
  6. RS485 Communication Terminal Block (if S option is selected)
  7. Product Certification Documents (CE, cULus)
  8. 競合他社 & Cross-Brand Replacement Comparison
ブランドモデル主な違いアプリケーションシナリオ
カルロ・ガヴァッツィWM12-96.AV5.3.3.SBuilt-in keypad, 96脳96 panel, RS485, IP65産業オートメーション, Building Energy Management
シュナイダーエレクトリックPM2000Graphic LCD, Modbus RTU/TCP, more measurement parametersHigh-end Energy Management System
シーメンス7KM2112Integrated energy metering, プロフィバスDP, higher accuracyProcess Industry, Smart Grid
ABBE200コンパクトな設計, 複数の通信プロトコル, 費用対効果の高いビルディングオートメーション, OEM Equipment
カルロ・ガヴァッツィWM3-9632-bit 渭P, グラフィック表示, advanced analytical functionsPower Quality Monitoring
  1. 選定ガイドライン & 代替ソリューション

Selection Mnemonic

AV5 for high voltage / AV6 for low voltage; 3 for 3-phase system / 3 for DC power; S with communication / X without

Selection Decision Tree

  1. Voltage Level: Select AV5 for above 380V; select AV6 for below 208V
  2. システムタイプ: 3 = Three-phase (推奨); others = Single-phase / Two-phase / ARON system
  3. 電源: 3 = 18-60VDC; A=24VAC; B=48VAC; C=115VAC; D=230VAC
  4. コミュニケーション: S = With RS485; X = Without communication
  5. 取付タイプ: WM12-96 = Panel Mount; WM12-DIN = DIN Rail Mount

推奨される交換ソリューション

Requirement Change推奨モデル理由
DINレール取付WM12-DIN.AV5.3.3.SSaves panel space, suitable for control cabinet installation
Lower Voltage SystemWM12-96.AV6.3.3.SCompatible with 120/208V systems
No Communication NeededWM12-96.AV5.3.XCost reduction with unchanged basic display functions
Higher Functional DemandWM3-9632-bit processor, グラフィック表示, power quality analysis
  1. アプリケーションシナリオ & Customer Value
  2. 産業オートメーション: Real-time monitoring of electrical parameters for motors, inverters and other equipment to prevent overload and faults.
  3. Building Energy Management: Monitor three-phase power distribution systems, optimize energy consumption and reduce operational costs.
  4. OEM Equipment Integration: Embedded as standard configuration in machine tools, 包装機械, 等, for equipment status monitoring.
  5. データセンター: Monitor UPS output and distribution cabinet load to ensure stable power supply.
  6. 再生可能エネルギー: Measure output parameters of photovoltaic inverters and wind turbines for energy efficiency evaluation.

Core Value: With high-precision TRMS measurement and multi-parameter display, it helps users quickly identify electrical abnormalities, optimize energy consumption, extend equipment service life and reduce maintenance costs.

Carlo Gavazzi WM12-96.AV5.3.3.S End-of-Life Information

Key Conclusion: This model together with the entire WM12 series was officially discontinued in April 2020. The official replacement is the WM15 series, while the WM14 series can be used as a temporary transitional replacement.

  1. Official EOL Basis

Carlo Gavazzi officially released an announcement in April 2020:

With the launch of the new WM15, the WM12, WM14, and EM26 are discontinued.

As a 96×96mm panel-mounted three-phase multifunction power indicator in the WM12 series, WM12-96.AV5.3.3.S is included in this full-series discontinuation.

  1. EOL Timeline & Replacement Arrangement
Time NodeEvent備考
Apr-20WM15 series launched; WM12 series officially discontinuedOfficial EOL (End of Life) Date
Before DiscontinuationWM14 series as upgraded replacement for WM12WM14-96AV533S is direct drop-in replacement for WM12-96.AV5.3.3.S
After April 2020WM15 series becomes final successor to WM12/WM14Higher accuracy (クラス 1 kWh) and added functions such as harmonic analysis
  1. Key Information of Replacement Products
  2. Direct Drop-in Replacement:

WM14-96AV533S (WM14-96×96 400/660V 5AAC 18-60VDC SERIAL)

Identical 96×96mm panel size and mounting method

Same AV5 range: 380/660V L-L / 5(6)そしてAC

Same 18-60VDC power supply and RS485 communication

  1. Final Upgraded Replacement: WM15 Series

Accuracy upgraded to Class 1 活性エネルギー用

Added harmonic distortion measurement

Supports single/two/three-phase and wild-leg systems

Optional pulse output, Modbus RTU or M-Bus communication

  1. 購入 & メンテナンスに関する推奨事項
  2. Stock Status: Only limited second-hand or surplus stock available; brand new original units are nearly out of stock.
  3. Maintenance Support: Carlo Gavazzi generally provides 6 years of spare parts support for discontinued models.
  4. Model Migration: New projects are recommended to adopt the WM15 series directly; existing projects can use the WM14 series for transitional upgrading.

Replacement Analysis of WM12-96.AV5.3.3.S and WM12-96.AV5.3.3.X

核となる結論: The two models are physically and hardware compatible and can be directly interchanged for installation; しかし, there is a key difference in communication functions. Their interchangeability depends on whether the system requires RS485 communication.

  1. Core Difference Comparison (Only One Distinction)
モデル主な違い機能的影響Application Limitation
WM12-96.AV5.3.3.SWith RS485 serial communication (S=Serial)Supports communication with host computer/PLC via Modbus RTU protocol for remote monitoring and data acquisitionSuitable for automation systems requiring centralized monitoring
WM12-96.AV5.3.3.XWithout RS485 communication (X=No Serial)Only local LED display available; remote data reading not supportedSuitable for simple applications requiring only on-site parameter viewing

All other parameters are completely identical:

ベースモデル: WM12-96 (96×96mm panel mounting, with built-in programming keypad)

Range code: AV5 (380/660V L-L / 5(6)そしてAC)

System type: 3 (1/2/3-phase system, unbalanced load)

電源タイプ: 3 (18-60VDC power supply)

Identical measurement accuracy, electrical specifications, physical dimensions and ingress protection rating

  1. Interchangeability Feasibility Judgment

2.1 ✅ Applicable Interchange Scenarios (Bidirectional)

System does not require RS485 communication: The X model can directly replace the S model, saving cost while fully meeting on-site display requirements.

Temporary replacement only: Either model can be used as a temporary spare part for fault maintenance without affecting basic measurement and display functions.

New project design: Selection based on actual communication demand; hardware mounting dimensions and wiring are fully compatible.

2.2 ❌ Non-interchangeable Scenarios (Unidirectional Restriction)

オリジナルモデルTarget ModelReason for Non-interchangeability解決
S (With Communication)× (Without Communication)The system relies on RS485 remote monitoring; communication will be interrupted after replacementKeep S model, or upgrade to communication-enabled WM15 series
× (Without Communication)S (With Communication)No communication wiring or host interface in the system; the communication function cannot be usedNo need for replacement, or upgrade after completing communication infrastructure
  1. Key Points for Replacement Operation

3.1 物理的な設置

Exactly the same 96×96mm panel cutout size, direct plug-and-play replacement.

Consistent terminal definition; no modification required for main circuit and power wiring.

Same ingress protection level (フロントIP65, Terminal IP20) with consistent environmental adaptability.

3.2 Function Configuration

The built-in programming keypad operates identically; original parameter settings can be copied directly.

Fully compatible in measurement parameters, display modes and alarm threshold configuration.

When replacing X with S, additional configuration of RS485 address (1-255) and communication parameters (9600bps, 8N1) が必要です.

3.3 Discontinuation & 交換の推奨事項

Both models were officially discontinued in April 2020 together with the entire WM12 series.

Official final replacement: WM15 Series (クラス 1 higher accuracy, with additional harmonic analysis function).

Transitional replacement: WM14-96AV533S / WM14-96AV533X (retains the same panel size and functions).

  1. 選択 & Decision Summary

Communication demand is the key; S with comm, X without. Physically interchangeable, only reliable with function matching.

Replacement Decision Tree

  1. Is RS485 communication required?

はい: Must choose S version or upgrade to communication-capable WM15 model

いいえ: Both S and X are acceptable; X is more cost-effective

  1. Does the system have existing communication infrastructure?

はい: Prioritize S version to make full use of existing resources

いいえ: Choose X version to avoid redundant functions