Ordering No.: 1SFA898216R7000
PSTX: ABB PSTX advanced ソフトスターター シリーズ, three-phase thyristor control with built-in bypass contactor
470: 定格動作電流 (In-line connection): 470 あ
690: Main circuit voltage: 208~690 VAC
70: 制御電源: 100–250 V AC, 50/60 Hz
- Key Technical Ratings
| アイテム | 仕様 |
| In-line rated current | 470 あ |
| Inside-delta equivalent current | 814 あ |
| Main circuit voltage | 208~690 VAC, 50/60 Hz |
| 制御電源 | 100–250VAC |
| 力 (列をなして, 400V) | 250 kW |
| 力 (列をなして, 690V) | 450 kW |
| 力 (Inside-delta, 690V) | 800 kW |
| Starting capacity | 4×Ie for 10 secondseero |
| 1 時間あたりの最大起動数 | 6 timeseero |
| 冷却 | Thermostat-controlled fan cooling, built-in bypass contactoreero |
| 保護クラス (主回路) | IP20; detachable keypad IP66eero |
| コミュニケーション | Built-in Modbus RTUeero |
| アナログ出力 | 現在 / 電圧 / Power factor selectable |
| Overload class | Class 10eero |
| 周囲温度 | -25~+60℃; Max altitude 4000 メートル (ディレーティングが必要)eero |
- 内蔵関数
ソフトスタート & ソフトストップ: 電圧ランプ, torque control ramp, 電流制限開始, dual current limit mode
Pump cleaning & anti-surge functions (ideal for pump applications)
Jog / slow speed, pre-start, kick start
Dynamic braking & standstill braking
Limp mode: Two-phase reduced-capacity operation if one thyristor fails
Fire emergency mode: Bypass all protections to force run
リアルタイムクロック, イベントログ, エネルギー計測, thyristor running hour counter
Auto phase sequence detection & auto restart
完全な保護: Electronic overload, ロックされたローター, 位相損失, current unbalance, 負荷が低い, 地絡, 過電圧/不足電圧, PTC/PT100 motor temperature monitoring, bypass fault, 通信障害
HMI: Color graphical display, 17 言語, detachable with password lock
- 代表的な用途
ウォーターポンプ, ファン, コンプレッサー, ベルトコンベア, crushers and other heavy-duty equipment. The built-in bypass cuts off thyristor current after full speed, eliminating continuous heat loss and saving energy.
- クロスシリーズ & 交換ノート
- PSTX470-600-70 (注文番号. 1SFA898116R7000): Max voltage 600V, cannot directly replace the 690V version
- PSTB470: Basic model without torque control, limp mode and pump cleaning; not an equivalent replacement
- 国内代替品: Renle, Xichi, Heping 470A/690V built-in bypass soft starters; communication and protection logic differ, PLC programs need modification
- インストール & メンテナンスのヒント
- 2 つの配線オプション: 列をなして (最も一般的な) / Inside-delta (boost motor power rating; soft starter only carries branch winding current)
- Sufficient cabinet ventilation; derate power for +60℃ ambient or high altitude
- Regularly inspect built-in bypass contacts; thyristors and cooling fans are wearing parts
- Set Modbus RTU address and baud rate via the keypad; refer to PSTX official communication manual for register mapping
Working Principle of Thyristor Soft Starters (ABB PSTX Type)
A soft starter is essentially a thyristor (SCR) AC voltage regulator wired in series with the three-phase motor main circuit. It adjusts the thyristor firing angle to gradually raise motor terminal voltage for smooth ramp-up start, and gradually lower voltage for smooth ramp-down stop — no sudden full voltage jump as in direct-on-line or star-delta starting.
- コアコンポーネント: Anti-parallel Thyristors per Phase
Each phase has a pair of reverse-connected thyristors:
Small firing angle → short conduction time → low output voltage
Gradually increasing firing angle → voltage rises smoothly
Full firing angle → output voltage nearly equals grid rated voltage
Thyristors only trigger at voltage zero-crossing in each AC half-cycle, enabling precise voltage regulation.
- Start-Stop Sequence (Built-in Bypass Model like PSTX)
- 待機する: Bypass contactor open; all current flows through thyristor modules
- Soft Ramp-up: Controller increases thyristor conduction angle step by step; motor voltage climbs slowly, limiting inrush current (no 5~7× rated current surge of DOL start). Two main modes: voltage ramp or torque-controlled ramp (PSTX exclusive)
- Bypass Closure: When motor reaches full speed, the built-in bypass contactor closes. Current transfers to mechanical contacts; thyristors exit the main circuit with no continuous heat generation
- 通常動作: Motor runs directly on mains; soft starter only monitors protection
- Soft Stop: Bypass opens again, switching back to thyristor voltage control; voltage ramps down slowly to stop the motor gently, eliminating water hammer in piping and mechanical shock on transmission parts
- Difference vs Star-Delta / Autotransformer Starters
Star-delta: Step voltage switching, still creates secondary current surges; only fixed voltage reduction ratio
Autotransformer: Step-down voltage only, bulky size, no continuous adjustable curve
Thyristor soft starter: stepless continuous voltage regulation, programmable start curves, plus braking, pump cleaning, full motor protection and fieldbus communication
- Two Common Starting Modes
電流制限開始: Lock maximum starting current first; voltage adjusts automatically to match load — preferred for heavy loads
Torque-controlled start (PSTX only): Regulates motor torque directly instead of pure voltage, delivering smoother acceleration with less mechanical impact
- Key Limitation
Thyristor voltage regulation only changes voltage amplitude, NOT frequency.
👉 Soft starter ≠ Variable Frequency Drive (VFD): Soft starters only control starting & 停止; they cannot run the motor continuously at variable speed. VFD adjusts both voltage and frequency for continuous speed regulation.
Common Faults for PSTX Built-in Bypass Soft Starters
- ヒートシンク / Thyristor Overheating (Fault F04xx)
症状: Trips after several starts; housing hot; cooling fan fails to run
根本原因:
Fan damaged or air duct blocked with dust
Cabinet sealed tightly; high ambient temperature or high altitude without derating
Bypass contactor fails to close; thyristors stay energized and overheat
Excessively long ramp time or frequent starts exceeding the 6 starts/hour limit
ソリューション: クリーンダスト, replace fan, verify start frequency, troubleshoot bypass circuit
- 欠相 / 3-Phase Current Imbalance (F03xx)
症状: Trips immediately on power-up; motor hums with heavy vibration
根本原因:
Blown fuses, open circuit breakers, loose terminal lugs or oxidized copper busbars
One-phase thyristor open-circuit or trigger failure
Broken motor winding or poor cable connection
区別: Input phase loss = supply side; Output phase loss = wiring between soft starter and motor or damaged SCR
- 過電流 / 短絡
症状: Instant trip on start; current far exceeds the set current limit
根本原因:
モーターロックローター (blocked impeller, ベアリングの焼き付き)
Cable or motor insulation breakdown (phase-phase or phase-earth short)
Starting voltage set too high or current limit value set too large
Thyristor short-circuited (do not retry starting repeatedly)
- Start Timeout (Failed to Reach Full Speed)
症状: Ramp finishes but motor never reaches rated speed; start timeout fault triggers
根本原因:
Current limit set too low or initial voltage too low (トルク不足)
過剰な負荷慣性, closed valve or heavy mechanical resistance
Wrong motor rated current parameter or undersized motor
Severe grid voltage drop during start
- Bypass-Related Faults (Most Frequent on PSTX: F0613, bypass failure, 連絡先の固着)
- Bypass fails to pull in: Thyristors remain energized and overheat rapidly
原因: Damaged coil, insufficient control voltage, bypass function disabled in parameters, internal detection circuit failure
- Bypass contactor welded shut: Input and output permanently shorted; soft stop function fails completely; 安全上の危険
原因: Frequent heavy-current cycling, arc erosion on contacts, repeated short-circuit surges
- Motor Overload Trip
症状: Trips after long running time, not during startup
根本原因:
Continuous overloaded operation, pump clogging, worn bearings
Incorrect motor rated current or Class 10 overload setting
Long low-speed operation leading to poor motor cooling; PTC/PT100 overtemperature alarm
- Underload Protection Trip
症状: Motor runs but current drops below threshold (dry-run protection for pumps/fans)
根本原因: Pump running dry, fully open valve with no load, broken belt or disconnected coupling
注記: Disable underload protection temporarily during no-load commissioning; re-enable after field commissioning.
- Thyristor SCR Damage (短い / 開回路)
症状: No clear fault code, but 3-phase current unbalanced, loss of voltage control, residual voltage on output after shutdown
根本原因: Grid surge / lightning strikes, repeated heavy starts, 冷却不良, output short-circuit impact
テスト: Disconnect power and measure resistance across each thyristor; shorted SCR shows near-zero resistance between input and output. Damaged power modules cannot be repaired and must be replaced.
- 制御電源 & 通信障害
No power on HMI: 黒い画面, random faults → low 100–250V control supply or blown internal fuse
Modbus RTU communication loss: PLC cannot read data → mismatched address/baud rate, poor shielding or ground interference
- Phase Sequence Fault
症状: Phase reversal alarm on power-up; start inhibited
根本的な原因: Incoming three-phase wiring reversed. You can disable phase sequence check temporarily (not recommended for permanent operation).
- Failed Soft Stop (Water Hammer)
症状: Motor stops abruptly, causing severe pipeline water hammer
根本原因: Soft stop ramp time set too short; welded bypass contactor prevents switching back to thyristor control, resulting in direct hard stop.
Fast On-Site Troubleshooting Sequence (PSTX Recommended)
- Check fault code and event log on the graphical display (PSTX stores full historical records)
- Cut off power and inspect all main terminals & busbars for overheating and loose connections
- Disconnect the motor and run no-load test to isolate faults: soft starter failure vs motor/mechanical load failure
- Verify bypass contactor operation and cooling fan rotation
- Double-check that all motor nameplate parameters match the soft starter settings
Full PSTX Series Model List (Built-in Bypass)
PSTX xxx-600-70 (208~600V AC)
| モデル | 注文番号. | 定格電流 | 400V Power |
| PSTX30-600-70 | 1SFA898103R7000 | 30 あ | 15 kW |
| PSTX37-600-70 | 1SFA898104R7000 | 37 あ | 18.5 kW |
| PSTX45-600-70 | 1SFA898105R7000 | 45 あ | 22 kW |
| PSTX60-600-70 | 1SFA898106R7000 | 60 あ | 30 kW |
| PSTX72-600-70 | 1SFA898107R7000 | 72 あ | 37 kW |
| PSTX85-600-70 | 1SFA898108R7000 | 85 あ | 45 kW |
| PSTX105-600-70 | 1SFA898109R7000 | 105 あ | 55 kW |
| PSTX142-600-70 | 1SFA898110R7000 | 142 あ | 75 kW |
| PSTX170-600-70 | 1SFA898111R7000 | 170 あ | 90 kW |
| PSTX210-600-70 | 1SFA898112R7000 | 210 あ | 110 kW |
| PSTX250-600-70 | 1SFA898113R7000 | 250 あ | 132 kW |
| PSTX300-600-70 | 1SFA898114R7000 | 300 あ | 160 kW |
| PSTX370-600-70 | 1SFA898115R7000 | 370 あ | 200 kW |
| PSTX470-600-70 | 1SFA898116R7000 | 470 あ | 250 kW |
| PSTX570-600-70 | 1SFA898117R7000 | 570 あ | 315 kW |
| PSTX720-600-70 | 1SFA898118R7000 | 720 あ | 400 kW |
| PSTX840-600-70 | 1SFA898119R7000 | 840 あ | 450 kW |
| PSTX1050-600-70 | 1SFA898120R7000 | 1050 あ | 560 kW |
| PSTX1250-600-70 | 1SFA898121R7000 | 1250 あ | 710 kW |
PSTX xxx-690-70 (208~690V AC, including PSTX470-690-70)
| モデル | 注文番号. | 現在 | 400V kW | 690V kW |
| PSTX30-690-70 | 1SFA898203R7000 | 30 あ | 15 | 25 |
| PSTX37-690-70 | 1SFA898204R7000 | 37 あ | 18.5 | 30 |
| PSTX45-690-70 | 1SFA898205R7000 | 45 あ | 22 | 37 |
| PSTX60-690-70 | 1SFA898206R7000 | 60 あ | 30 | 45 |
| PSTX72-690-70 | 1SFA898207R7000 | 72 あ | 37 | 55 |
| PSTX85-690-70 | 1SFA898208R7000 | 85 あ | 45 | 59 |
| PSTX105-690-70 | 1SFA898209R7000 | 105 あ | 55 | 75 |
| PSTX142-690-70 | 1SFA898210R7000 | 142 あ | 75 | 90 |
| PSTX170-690-70 | 1SFA898211R7000 | 170 あ | 90 | 132 |
| PSTX210-690-70 | 1SFA898212R7000 | 210 あ | 110 | 160 |
| PSTX250-690-70 | 1SFA898213R7000 | 250 あ | 132 | 184 |
| PSTX300-690-70 | 1SFA898214R7000 | 300 あ | 160 | 220 |
| PSTX370-690-70 | 1SFA898215R7000 | 370 あ | 200 | 257 |
| PSTX470-690-70 | 1SFA898216R7000 | 470 あ | 250 | 355 |
| PSTX570-690-70 | 1SFA898217R7000 | 570 あ | 315 | 450 |
| PSTX720-690-70 | 1SFA898218R7000 | 720 あ | 400 | 560 |
| PSTX840-690-70 | 1SFA898219R7000 | 840 あ | 450 | 710 |
| PSTX1050-690-70 | 1SFA898220R7000 | 1050 あ | 560 | 800 |
| PSTX1250-690-70 | 1SFA898221R7000 | 1250 あ | 710 | 1000 |
PSTB Basic Series (Reduced Functions, Built-in Bypass)
| モデル | 注文番号. | 現在 | 400V Power |
| PSTB370-600-70 | 1SFA894015R7000 | 370 あ | 200 kW |
| PSTB470-600-70 | 1SFA894016R7000 | 470 あ | 250 kW |
| PSTB570-600-70 | 1SFA894017R7000 | 570 あ | 315 kW |
| PSTB720-600-70 | 1SFA894018R7000 | 720 あ | 400 kW |
| PSTB840-600-70 | 1SFA894019R7000 | 840 あ | 450 kW |
| PSTB1050-600-70 | 1SFA894020R7000 | 1050 あ | 560 kW |
PSTB does not support torque control, limp mode or pump cleaning. Only for simple fan & pump start-stop; not a direct replacement for PSTX.
PSR Compact Soft Starters (経済的, NO Built-in Bypass)
| モデル | 注文番号. | 現在 | 400V Power |
| PSR3-600-70 | 1SFA896103R7000 | 3 あ | 0.75 kW |
| PSR6-600-70 | 1SFA896104R7000 | 6 あ | 1.5 kW |
| PSR9-600-70 | 1SFA896105R7000 | 9 あ | 2.2 kW |
| PSR12-600-70 | 1SFA896106R7000 | 12 あ | 3 kW |
| PSR16-600-70 | 1SFA896107R7000 | 16 あ | 4 kW |
| PSR25-600-70 | 1SFA896108R7000 | 25 あ | 5.5 kW |
| PSR30-600-70 | 1SFA896109R7000 | 30 あ | 7.5 kW |
| PSR37-600-70 | 1SFA896110R7000 | 37 あ | 11 kW |
| PSR45-600-70 | 1SFA896111R7000 | 45 あ | 15 kW |
| PSR60-600-70 | 1SFA896112R7000 | 60 あ | 18.5 kW |
| PSR72-600-70 | 1SFA896113R7000 | 72 あ | 22 kW |
| PSR85-600-70 | 1SFA896114R7000 | 85 あ | 30 kW |
| PSR105-600-70 | 1SFA896115R7000 | 105 あ | 37 kW |
Series Quick Comparison
- PSTX: High-end flagship, color HMI, トルク制御, 制動, pump cleaning, Modbus, 完全な保護, 内蔵バイパス; preferred for export industrial projects
- PSTB: Mid-range basic model, モノクロ画面, limited functions, 内蔵バイパス
- PSR: Compact low-cost version, no built-in bypass, requires external bypass contactor; only for small-power motors
- PSS / PST: Older legacy models, 段階的に廃止された; only available as spare parts for existing installations, 新しいプロジェクトには推奨されません
Optional Communication Accessories (PSTX)
PS-FBPA: 1SFA896312R1002, basic fieldbus adapter
PSTX ANYBUS Modbus RTU: 1SFA899300R1003
コンタクタ,サーキットブレーカー,センサー,エンコーダ,PLC,コンバータ