フルモデル: PNOZ s7 C 24VDC 4 いいえ 1 該当なし
Pilz PNOZsigma Series セーフティリレー
基本仕様
注文番号: 750330
供給: 24 ワシントンDCで
安全接点: 4 通常は開いています (いいえ)
補助接点: 1 通常は閉まっている (該当なし)
幅: 22.5 mm
関数: For safety emergency stop, 安全ゲートの監視, two-hand control and other safety circuit evaluation
シリーズ: PNOZ s7 C (C = with cascade interface, for connecting extension modules)
認証: CE, UL, テュフ; Safety Level PL e/SIL 3 (Compliant with ISO 13849-1/IEC 62061)
代表的な用途
Emergency stop button circuit monitoring
セーフティゲートスイッチ, 安全リミットスイッチ
Small automation machines, 工作機械, packaging machinery safety control
Can be cascaded with PNOZsigma extension modules (s0, s1, s2, s4, s5, s6, s7, s8, s9) for contact expansion
Confusing Model Comparison
750107: PNOZ s7 (without C, カスケード機能なし)
750330: PNOZ s7 C (cascade-capable version)
配線上の注意
- S11/S12: Safety Input Channel 1
- S21/S22: Safety Input Channel 2 (Dual-channel monitoring)
- 13/14, 23/24, 33/34, 43/44: Four safety normally open outputs
- 51/52: Auxiliary normally closed feedback contact
- UB/0V: 24V DC電源
代替リファレンス
同シリーズの代替品: Original product is preferred for the same specification; domestic safety relays can be used for functional replacement (PL level, contact configuration and wiring logic must be verified)
アップグレード: If more contacts are required, cascade with PNOZ s extension modules
追加情報
保護クラス: IP20 (DINレール取付, キャビネット設置のみ)
取り付け: DIN 35mmレール
動作温度: -10 ℃~ +55 ℃
キノコ 750330 (PNOZ s7 C) 配線説明書 + トラブルシューティングのチェックリスト
Important Precaution: PNOZ s7 C is a contact extension module. It cannot be used as a standalone master module. It must be used with PNOZsigma master safety relays (s1/s2/s4/s5/s6 etc.); C = cascade connector, connected to master module via U-link. It is NOT an independent evaluation unit.
- 端子の定義
A1: 24VDC+
A2: 24VDC-
安全出力 (Force-guided normally open, 安全回路用)
13-14, 23-24, 33-34, 43-44 (4 sets n/o)
補助接点 (Not allowed for safety cut-off circuits, only for PLC feedback/indicator lamps)
51-52 (1 set n/c)
Top side: Cascade slot + Terminator plug
- Two Wiring Schemes
スキーム 1: Cascade with PNOZsigma Master Module (推奨, with pulse detection)
- Mount master module and s7 C side by side on DIN rail, remove terminator plugs on both modules
- Insert PNOZsigma U-link connector; internal safety signals are transmitted from master module to s7C
- Master module is powered at A1/A2; s7C A1/A2 also requires separate 24V DC supply
- Route outputs 13-14/23-24/33-34/43-44 into contactor coil circuits; a 6A fuse is recommended to prevent contact welding
- 51-52 is wired to PLC digital input for status feedback
Cascade Rule: The terminator plug must be fitted on the LAST module of the cascade chain! Fault will be triggered if missing.
スキーム 2: Hardwired extension for non-sigma series (PNOZ X etc., no U-link)
The safety output contact of the master relay is wired into the s7 C supply loop (master safety contact acts as enable for s7C power supply)
Master contact closed → s7C energized, all safety outputs closed
Master contact open → s7C de-energized, all safety outputs open
⚠️ No internal short-circuit pulse diagnosis in this mode. Safety architecture is downgraded, only for low-risk applications.
- Safety Wiring Rules
- マックス. load for safety outputs: ≤6A, 240VAC; fuses are mandatory to avoid contact welding
- 51-52 auxiliary contact must not be used for safety cut-off, only for status signals
- ケーブル: Copper wire with ferrule for cabinet wiring, スプリング端子; IP20, no exposed wiring
- Emergency stop/safety gate logic is fully configured on the PNOZsigma master module (mode selector, dual-channel detection, auto/manual reset). s7C only follows the output state
- Check U-link connection regularly for vibration-prone applications (工作機械, コンベア)
- LED インジケータの定義 (PNOZ s7C itself)
POWER: 24V supply present
外: Safety outputs closed (master module permits output)
故障: Diagnostic error/fault lockout
IN1, IN2 indicators are located on the master module. The s7C extension module has no input indicators.
- トラブルシューティングのチェックリスト (順番に)
故障 1: FAULT LED ON continuously, 出力なし (most frequent)
原因 1: Terminator plug missing or not installed on the last module
救済策: 電源を切る, fit terminator plug on the last module’s cascade slot, power on and reset
原因 2: U-link loose or not fully clipped
救済策: 電源を切る, re-seat U-link and confirm locking
原因 3: No supply/reversed polarity/excessive voltage drop on A1/A2
救済策: Measure A1-A2 voltage with multimeter, confirm stable 24VDC; check spring terminal loose connections
原因 4: Master module FAULT, wrong mode setting, short circuit on master input channels
救済策: Troubleshoot master module first; s7C will only work normally once master is recovered
故障 2: POWER LED ON, OUT LED OFF, FAULT LED OFF
原因 1: Master safety relay is in safe-off state (非常停止が押されました, safety gate open)
救済策: Reset E-stop/close safety gate, confirm master OUT LED lights up
原因 2: Master module set to manual reset and reset button not pressed
原因 3: Wrong cascade order; master module is not the first unit in chain
原因 4 (hardwired mode): Master safety contact damaged/open circuit
故障 3: Intermittent FAULT trigger, output flickering
原因 1: U-link loose due to cabinet vibration (工作機械, コンベアライン)
原因 2: High ripple/insufficient capacity/frequent dip on 24V power supply
原因 3: Short circuit on output circuit, fuse blown and safety lockout activated
原因 4: Cross-wire/earth short circuit on master module input wiring (pulse detection triggers fault)
故障 4: FAULT latched, cannot reset after power cycle
原因: Internal safety contact welding (overload/short circuit without fuse protection)
救済策: Module cannot be repaired; 直接交換する. Add fuses on output circuits to prevent recurrence.
故障 5: Master module normal, s7C output out of sync
原因: Poor U-link contact; or welded contact on intermediate contactor in hardwired configuration
- Standard Commissioning Procedure
- 電源を切る, mount on DIN rail, wire power supply, fit U-link and terminator plug
- Wire master module and set mode selector (adjust selector only when power OFF; changing under power will lock fault)
- Verify fuses on all safety output loops
- 電源を入れる. Master IN1/IN2 OK, master OUT ON → s7C POWER + OUT ON
- 機能テスト: Trigger E-stop/open gate → master OUT OFF, s7C OUT opens synchronously; reset and confirm synchronous closing
- 記録: Safety function verification must be performed after every wiring change or module replacement
- Quick Comparison: s7 (750107) vs s7 C (750330)
750107: PNOZ s7, 拡大, no C, U-link cascade not supported
750330: PNOZ s7 C, 拡大, C version, U-link cascade supported (あなたのモデル)
Working Principle of PILZ 750330 (PNOZ s7 C)
主要な概要: It has no input channels and no safety logic evaluation function. It is a follower-type extension module equipped with force-guided safety contacts. Safety judgement, dual-channel detection and short-circuit pulse diagnosis are all performed by the upstream PNOZsigma master module. The s7 C only synchronously follows the master safety command and feeds back its actual contact status to the master for verification.
重要: PL e/SIL3 safety rating is determined by the master module. s7 C alone cannot raise the safety level.
- Internal Hardware Structure
内部: Two independent safety relays with mechanically linked force-guided contacts, 4 safety normally open outputs + 1 auxiliary normally closed feedback contact
電源: Independent 24VDC supply on A1/A2 (not powered by master module)
Top U-link port: Dual-channel drive signals + feedback return line, safety link; not ordinary communication bus
Terminator plug: Closing component for the end of cascade chain, used by master module to confirm chain integrity; fault is triggered if removed
- Standard Cascade Mode (U-link connection, recommended dual-channel safety architecture)
- Master module (s1/s2/s4/s5/s6 etc.) collects E-stop and safety gate signals, performs dual-channel comparison, cross-line short-circuit pulse detection and reset logic
- When safety conditions are satisfied, master sends synchronized dual-channel drive signals to s7 C via U-link
- s7 C receives valid drive signals → internal two safety relays pull in simultaneously, 13-14, 23-24, 33-34, 43-44 four safety contacts close
- Critical safety closed-loop: The actual contact state of s7 C is sent back to master module via cascade lines
Master continuously compares: issued command vs real feedback contact status
Matched: 通常動作
Mismatched (接触溶接, failure to act, 断線, loose U-link): Master cuts drive immediately, whole safety chain locks FAULT, safety contacts force open
- Once safety trip condition occurs (非常停止が押されました, 安全ゲートが開いた): Master stops drive signal → s7C relays de-energize, all safety contacts open; status feedback is sent back to master for verification
This bidirectional verification is the core of force-guided contact + feedback monitoring, preventing dangerous failure mode where contacts remain conductive after open command due to welding.
- Hardwired Mode (without U-link, downgraded single-channel)
Master safety output contact is wired into s7C supply enable loop:
Master contact closed → s7C energized, outputs closed
Master contact open → s7C de-energized, 出力がオープン
⚠️ Defect: No dual-channel feedback. Master cannot diagnose internal faults of s7C. Safety architecture no longer meets PL e, only for low-risk applications.
- LED Logic
POWER: A1/A2 24V supply OK
外: Valid drive signal received from master, safety contacts closed
故障: Master detects chain anomaly (loose U-link, missing terminator, inconsistent feedback, broken cascade line), safety lockout activated
- Diagnosis Principle (Why missing terminator triggers FAULT)
The whole cascade chain forms a serial closed diagnostic loop: Master → s7C1 → s7C2 → … → terminator plug on last module.
Master continuously sends diagnostic pulses scanning the whole chain. The terminator acts as an end termination resistor to close the pulse circuit.
Plug removed → pulse circuit open → master detects broken chain and locks FAULT to prevent uncontrolled extension module behaviour.
- Function Division: Master vs s7 C
マスターモジュール:
Connect E-stop/safety gate inputs
Dual-channel detection, cross-wire short-circuit detection, reset logic
Send drive commands + receive feedback and fault judgement from all extension modules
PNOZ s7 C (750330):
No input terminals, cannot connect E-stop
アクション: Pull in/open safety contacts synchronously
Feed back real contact status continuously to master for verification
Only increases available safety contacts, no safety logic evaluation
- Core Safety Design
Internal relays adopt mechanical force-guided structure: If one relay contact welds closed, the mechanical coupling ensures the other contact opens reliably. This anomaly is fed back to master and triggers fault lockout, avoiding dangerous “command open but contact conductive” failure.
Pilz PNOZ Safety Relay Order List
注記: PNOZsigma (750xxx/751xxx) is current mainstream series; PNOZ X (774xxx /777xxx /787xxx) is legacy classic series; PNOZmulti2 is programmable safety controller. s7 C (750330) is sigma contact extension module and cannot be used standalone.
Abbreviation: n/o=normally open, n/c=normally closed, n/o t=delayed-off normally open, SC=semi-conductor output
- PNOZsigma Series (24VDC, 好ましい, PL e/SIL3)
Standalone Master Modules (can work alone for E-stop/safety gate)
| 注文番号. | フルモデル | 接点仕様 | 幅 | 備考 |
| 750101 | PNOZ s1 24VDC 2n/o | 2いいえ | 12.5mm | 単一チャンネル, 基本的な |
| 750102 | PNOZ s2 24VDC 3n/o 1n/c | 3NO+1NC | 17.5mm | 単一チャンネル |
| 750103 | PNOZ s3 24VDC 2n/o | 2いいえ | 17.5mm | Dual-channel short-circuit detection |
| 751103 | PNOZ s3 C 24VDC 2n/o | 2いいえ | 17.5mm | Cascade C version |
| 750104 | PNOZ s4 24VDC 3n/o 1n/c | 3NO+1NC | 22.5mm | デュアルチャンネル, 広く使われている |
| 750105 | PNOZ s5 24VDC 2n/o 2n/o t | 2NO+2 delayed NO | 22.5mm | Delay-off type |
| 750106 | PNOZ s6 24VDC 3n/o 1n/c | 3NO+1NC | 22.5mm | Two-hand control dedicated |
| 750107 | PNOZ s7 24VDC 4n/o 1n/c | 4NO+1NC | 22.5mm | Extension, no U-link cascade |
| 750330 | PNOZ s7 C 24VDC 4n/o 1n/c | 4NO+1NC | 22.5mm | Cascade C version, U-link compatible (あなたのモデル) |
| 750108 | PNOZ s8 24VDC 2n/o | 2いいえ | 12.5mm | Small contact extension |
| 750109 | PNOZ s9 24VDC 3n/o | 3いいえ | 17.5mm | Contact extension |
| 750110 | PNOZ s10 24VDC 2n/o | 2いいえ | 12.5mm | Dual-channel light curtain |
| 750111 | PNOZ s11 24VDC 4n/o | 4いいえ | 22.5mm | デュアルチャンネル |
| 750124 | PNOZ s4.1 24VDC | 3NO+1NC | 22.5mm | Special reset mode |
| 750126 | PNOZ s6.1 24VDC | 3NO+1NC | 22.5mm | Improved two-hand control |
| 750150 | PNOZ s20 24VDC | Semi-conductor output | 12.5mm | Pure semiconductor |
| 750151 | PNOZ s22 24VDC | Semi-conductor output | 17.5mm | Light curtain dedicated |
| 750130 | PNOZ s30 24VDC | 2NO+2 delayed NO | 22.5mm | Long delay |
| 750152 | PNOZ s50 24VDC | Semi-conductor | 22.5mm | Semi-conductor safety output |
Sigma Accessories
| 注文番号. | 説明 |
| 750008 | PNOZsigma U-link Cascade Connector |
| 750009 | Terminator Plug (mandatory at end of chain) |
- PNOZ X Legacy Series (AC/DCユニバーサル, for replacement of existing projects)
Basic E-stop/Safety Gate Models
| 注文番号. | モデル | 連絡先 | 供給 |
| 777303 | PNOZ X2P | 2いいえ | 24VAC/DC |
| 787059 | PNOZ X7P C | 2いいえ | 24VAC/DC |
| 774053 | PNOZ X7 | 2いいえ | 110VAC |
| 774055 | PNOZ X7 | 2いいえ | 120VAC |
| 774057 | PNOZ X7 | 2いいえ | 240VAC |
| 787100 | PNOZ X1P C | 3NO+1NC | 24VDC |
| 787310 | PNOZ X3P C | 3NO+1NC | 24VAC/DC |
| 774729 | PNOZ X6 | 3いいえ | 24VAC/DC |
| 774080 | プノーシス 11 | 7NO+1NC | 24VAC/DC |
| 774006 | プノーシス 10 | 6NO+4NC | 230-240VAC |
Delay-off XV Series
| 注文番号. | モデル | 連絡先 | 遅延範囲 |
| 777510 | PNOZ XV3P 30 | 3NO+2 delayed NO | 0.1~30代 |
| 774610 | PNOZ XV3.1 30 | 3NO+1NC+2 delayed NO | 0.1~30代 |
| 774618 | PNOZ XV3.1 300 | 3NO+1NC+2 delayed NO | 0.3~300s |
Two-hand Control P2HZ Series
| 注文番号. | モデル | 連絡先 |
| 777340 | P2HZ X1P | 3NO+1NC+2SC |
| 774350 | P2HZ X3 | 2NO+1NC |
| 774360 | P1HZ X1 | 2いいえ |
Contact Extension PZE Series (for PNOZ X master)
| 注文番号. | モデル | 連絡先 |
| 774580 | PZE X4 | 4いいえ |
| 777580 | PZE X4P | 4いいえ |
| 774590 | PZE X5 | 5いいえ |
| 777600 | PZE 9P | 7NO+2NC |
- PNOZmulti 2 Programmable Safety Controllers (Large machines, multi safety functions)
| 注文番号. | モデル | 説明 |
| 772100 | PNOZ I B0 | ベースユニット, 拡張可能な |
| 772104 | PNOZ m B0.1 | B0 upgraded version |
| 772105 | PNOZ m C0 | コンパクト, 拡張不可能 |
| 772138 | PNOZ m ES ETH | イーサネット通信モジュール |
- クイックセレクションガイド
- 750xxx = PNOZsigma new series; 750xxx without C = standalone/hardwired extension; 751xxx /7503xx with C = U-link cascade supported
- 774/777/787xxx = PNOZ X legacy series, for spare replacement only, 新しいプロジェクトには推奨されません
- 772xxx = PNOZmulti2 programmable safety controller (not simple safety relay)
- s7 (750107) and s7C (750330) are both extension modules, cannot connect E-stop independently, must pair with sigma master
- Confusing Model Reference
750107: PNOZ s7, 拡大, no C, U-link cascade not supported
750330: PNOZ s7 C, 拡大, C version, U-link cascade supported