Dedicated mounting subbase for FRS100 series multi-burner combustion safety controllers. 別売り; controller main unit NOT included.
- モデルコードの定義
FRS: Platform for FRS100 series combustion safety controllers
50: Subbase assembly code
あ: Subbase version
100: Standard DIN rail mounting subbase
Compatible main units: FRS100B / FRS100C series burner controllers (例えば. FRS100C100-2, FRS100C200-2, FRS100C300-2)
- Functional Description
- Terminal block for electrical wiring: All wiring for 電源, flame detection, valve output, alarm and flame signal connects to the FRS50A100 subbase. The controller main unit plugs onto the subbase, enabling convenient replacement and maintenance without rewiring.
- 取り付けオプション: DIN35mm rail mounting or direct screw mounting.
- Mechanical positioning: The FRS100 main unit latches onto the subbase with locking structure. The main unit can be detached without modifying field cables.
- Terminal load rating: Matches contact rating of FRS100 controller (250VAC), capable of carrying loads for main fuel valve and alarm circuits.
- Complete System Composition
Full combustion safety assembly = FRS100 controller main unit + FRS50A100 subbase + flame detector
Optional flame detectors:
Flame rod: C7007A, C7008A
UV ultraviolet flame scanner: C7012A / C7012C
- 主な仕様 (System with Subbase)
電源: 100VAC / 200VAC, 50/60Hz (determined by FRS100 main unit)
Rated contact: 250VAC, 250バージニア州
Flame signal output: 0~5VDC (Terminals A/B, シールドケーブル, 最大. 5メートル)
周囲温度: -20~+60°C for single unit installation; -20~+45°C for side-by-side multi-unit mounting
応用: Intermittent combustion equipment (industrial furnaces, boilers, heat treatment furnaces) for flame monitoring, flame failure protection and ignition interlock. Fuel valve cuts off upon abnormal conditions to prevent deflagration.
- モデルの選択 & 交換ノート
- FRS50A100 is only compatible with FRS100 series. Not compatible with legacy RX series or FRS60 series controllers.
- When replacing the subbase, terminal definition remains unchanged. Always verify burner sequence (purge time, flame failure response time) defined by FRS100 main unit model; subbase does not alter timing logic.
- Spare part procurement: FRS100 main unit and FRS50A100 subbase are separate part numbers and must be ordered individually.
- よくあるトラブルシューティング (Subbase Related)
No power indicator: Check subbase power terminal wiring, built-in fuse (inside main unit), and power supply voltage fluctuation.
Unstable flame signal: Poor shielding/earthing on A/B analog signal terminals of subbase; aged flame detector cable.
Valve circuit inoperative: Loose wiring on terminals 3-4 そして 3-8 of subbase, contact overload.
azbil FRS50A100 (Subbase) 寸法 (ユニット: mm)
Data extracted from official drawing: FRS50A100 subbase alone
幅: 45 mm (DIN35 standard rail compatible, subbase body width 45mm)
身長: 90 mm
深さ: 35 mm
重さ: 約. 70 g
Assembled Dimensions (FRS100 Main Unit + FRS50A100 Subbase, for cabinet layout)
幅: 45 mm
身長: 110 mm
深さ: 68 mm
Mounting Related Dimensions
- レール: Compatible with DIN35mm standard rail
- Subbase screw mounting holes: 2 取り付け穴, pitch 82mm, M3.5 terminal screws
- Cabinet clearance: ≥15mm space required above for main unit removal
azbil FRS50A100 Subbase Two Mounting Methods
方法 1: DIN35 Standard Rail Mounting (最も一般的な)
- Pull down DIN rail latch on the rear side of subbase
- Hook subbase onto cabinet DIN35 rail, arrow on subbase pointing upward (must be vertically mounted with arrow facing up)
- Push back latch to lock subbase onto rail
- Fix subbase first, complete terminal wiring, then insert FRS100 main unit and fasten central locking screw (torque 0.3N·m)
方法 2: Direct Panel Screw Mounting (No rail available)
- Subbase is pre-drilled with 2 through mounting holes; use M4 screws to fasten onto cabinet backplate / 取り付けプレート
- Recommended tightening torque: 0.7N・m. Do not over-tighten to avoid cracking subbase housing
- Keep arrow pointing upward with vertical installation; horizontal or inverted mounting prohibited
Assembly Notes for Main Unit (After subbase installation)
FRS100 controller plugs and latches onto FRS50A100 subbase
Max torque for main unit central locking screw: 0.3N・m
Main unit can be removed without detaching subbase or field cables, convenient for maintenance and replacement
Mandatory Installation Requirements
- 取付方向: Vertical flat surface, arrow pointing upward. 水平, inverted or tilted installation is forbidden, which will compromise flame detection and timing reliability.
- 環境: Keep away from condensation, 重い粉塵, strong vibration and high-temperature heat sources.
- Multi-unit side-by-side installation: Maintain heat dissipation gaps; ambient temperature upper limit will decrease otherwise.
補足
All field wiring terminates on the subbase; main unit is only the pluggable module. For on-site maintenance, simply loosen the central screw of main unit and pull it out, subbase and cables remain untouched.
azbil FRS100 Series Full Model List for Multi-Burner Combustion Safety Controllers
Full assembly = FRS100 main unit + FRS50A100 subbase (subbase sold separately). サフィックス -2 denotes revised version, preferred for domestic projects.
- FRS100B Series (Standard Sensitivity, Max Power Consumption 3W)
| モデル | 供給電圧 | 説明 |
| FRS100B100-2 | AC100V | 標準タイプ, compatible with flame rod / UV scanner |
| FRS100B200-2 | AC200V | 標準タイプ, compatible with flame rod / UV scanner |
| FRS100B104-2 | AC100V | Version with additional auxiliary contact |
| FRS100B204-2 | AC200V | Version with additional auxiliary contact |
- FRS100C Series (標準 & High Sensitivity Versions, Max Power Consumption 7W)
| モデル | 供給電圧 | 説明 |
| FRS100C100-2 | AC100V | Standard sensitivity |
| FRS100C200-2 | AC200V | Standard sensitivity |
| FRS100C300-2 | AC200V | Special timing sequence version |
| FRS100C104-2 | AC100V | Standard sensitivity + 補助接点 |
| FRS100C204-2 | AC200V | Standard sensitivity + 補助接点 |
| FRS100C304-2 | AC200V | Special timing + 補助接点 |
| FRS100C150-2 | AC100V | High Sensitivity (for weak flame) |
| FRS100C250-2 | AC200V | High Sensitivity (for weak flame) |
| FRS100C350-2 | AC200V | 高感度 + special timing |
| FRS100C154-2 | AC100V | 高感度 + 補助接点 |
| FRS100C254-2 | AC200V | 高感度 + 補助接点 |
| FRS100C354-2 | AC200V | 高感度 + special timing + 補助接点 |
Ⅲ. Associated Spare Parts
- FRS50A100: Controller mounting subbase (DINレール / ネジ取付, the model you queried)
- FSP300C100: Flame simulator, used for field verification of FRS100 flame detection circuit
Model Coding Rules for Quick Selection
FRS100: シリーズコード (Multi-burner flame safety relay)
B / C: B=low power consumption; C=higher power consumption and supports high sensitivity models
33桁目: 1=AC100V; 2=AC200V; 3=AC200V special timing
4桁目: 0=standard output; 4=additional alarm auxiliary contact
5桁目: 0=normal sensitivity; 5=high sensitivity
-2: ハードウェア リビジョン番号; revised version preferred for domestic projects
Model Selection Guidance
- FRS100B: 低消費電力, for stable regular flame conditions; high sensitivity not available.
- FRS100C: Supports high sensitivity variants, suitable for small burners and weak flame signals; higher power consumption.
- Suffix `4`: Adds one extra auxiliary contact for alarm feedback to upper control system.
- All FRS100 main units share the same FRS50A100 subbase.
- Flame detection options: Flame rod C7007A/C7008A, UV scanner C7012A/C7012C
代表的な用途
Intermittent combustion equipment: Heat treatment furnaces, bogie furnaces, small gas boilers, industrial kilns, multi-burner manual ignition with flame failure safety interlock.
Optional deliverables:
- Selection table including flame failure response time and purge time
- BOM template (モデル + 説明 + 数量) for purchasing
- Notes for replacement between FRS100B and FRS100C
Application Scenarios for azbil FRS100C High Sensitivity Models (FRS100C150/250/350, including auxiliary contact versions 154/254/354)
コア機能: Capable of detecting weak flame signals, easier to capture low-intensity flame than standard sensitivity FRS100C. Designed for intermittent manually ignited combustion equipment where flame signal is weak or attenuated by flue gas/dust. Not for 24-hour continuous firing equipment.
- 一般的な作業条件
- Small Gas Burners / Low-load Holding Fire Conditions
Low-power natural gas / LPG burners with faint holding flame during low-temperature standby; flame rod output signal is low, standard models often trigger false flame-out alarms.
Bogie furnaces, small holding furnaces, aluminum holding furnaces, small melting furnaces with weak flame at low holding temperature.
- Furnaces with heavy flue gas and dust causing flame signal attenuation
Heat treatment furnaces, carburizing furnaces, degreasing furnaces, deodorizing furnaces, small waste incinerators. Flue gas, carbon black and dust contaminate UV scanner or flame rod and weaken flame signal.
Flame detector cannot be installed facing the flame due to layout restriction, resulting in weak received optical signal.
- Long detector wiring with signal attenuation
Flame rod / UV scanner is located far away from controller; shielded cable introduces signal attenuation. High sensitivity model can identify lower flame voltage.
マックス. limit: Shielded cable length ≤10m.
- Low-NOx retrofit burners with transparent, low-radiation flame
Low-NOx premix burners produce highly transparent flame with weak UV emission. Standard sensitivity controllers often suffer unstable flame signals and frequent false flame-out alarms; high sensitivity version is preferred.
- Multi-burner furnaces with independent flame monitoring per burner
Each burner of multi-burner furnace is equipped with individual FRS100C high sensitivity controller. Reliable flame failure detection for individual burners with small and faint flame.
- Industry Equipment Reference List (Direct for selection)
- Metal heat treatment: Bogie heat treatment furnaces, box annealing furnaces, aluminum melting & holding furnaces, die-casting holding furnaces
- Environmental protection: Small waste gas deodorizing furnaces, batch-operated small RCO/TO incinerators
- 塗装業: Gas batch curing ovens, paint booth drying furnaces
- 軽工業: Food drying furnaces, small ceramic kilns
- Small process boilers (batch start-stop, non 24h continuous operation)
- Selection Boundary (Critical to avoid wrong selection)
✅ Suitable: Intermittent, manual ignition, batch-run combustion equipment; weak flame, dusty/flue gas environment, low-NOx premix holding fire.
❌ Not suitable:
- 24-hour continuous combustion equipment (Use AUR series flame relays with continuous self-check function)
- Heavy fuel oil burners (Heavy oil soot contamination, UV scanner selection must be evaluated carefully)
- Flame completely blocked with zero UV / ion signal (No controller can detect flame regardless of sensitivity grade)
- Recommended Detectors
Ionization flame rod: C7007A / C7008A
UV ultraviolet scanner: C7012A, C7035A, AUD100 series
- Comparison vs Standard Sensitivity Models
Standard sensitivity FRS100C: Sufficient bright and clean flame, conventional gas burners.
High sensitivity FRS100C (150/250/350): Weak flame, heavy flue gas/dust, low-NOx premix, holding fire. Better weak flame detection capability. 注記: Proper shield grounding is mandatory to prevent false flame detection caused by electrical interference.
- Compatible Subbase
High sensitivity models use FRS50A100 subbase universally. Subbase has no sensitivity grading.