(Standard part number: FWP-25A22F. The suffix FA is a trade designation; AMP25 means 25A and is not part of the original イートン model number.)
製品タイプ: aR IEC cylindrical high-speed semiconductor ヒューズ (ceramic tube, ferrule terminals), 22×58mm size
型式コードの説明
FWP: Bussmann IEC high-speed semiconductor fuse series
25: 定格電流 25A
あ: aR (semiconductor protection, 短絡保護のみ; not suitable for sustained overload)
22: Size code for 22×58mm
F: No striker / no fuse indication (FI = with striker, can actuate microswitch)
FA: 市場 / customs alias; official part number is FWP-25A22F
AMP25: Simple current marking of 25A, not part of original model
コアの電気仕様
定格電圧: 700Vと / 700ワシントンDCで (IEC/UL)
定格電流: 25あ
遮断容量: AC 200kA (symmetrical rms); DC 50kA @700Vdc
Fuse Class: aR (semiconductor short-circuit protection)
Pre-arcing I²t: 37; Total clearing I²t @700VAC: 530
Rated Power Dissipation: 6W
フォームファクター: 22×58mm, ceramic tube, copper ferrules at both ends
正味重量: 約. 62.6g
認証 & コンプライアンス
UL Recognized JFHR2, CSA, CE, RoHS
Compatible Fuse Holder: JM70100 (matching safety fuse base)
代表的な用途
Short-circuit protection for DC busbars, DC drives, 周波数変換器, 整流器 / power converters, SCR and IGBT semiconductor devices. Widely used in PV energy storage, servo power supplies and UPS DC sides.
注記: aR provides short-circuit protection only and cannot replace gR overload protection.
Comparison with Similar Models
FWP-25A22F: No striker (このモデル)
FWP-25A22FI: With striker, triggers microswitch for alarm upon melting
FWP-25G22F: gR class (過負荷 + 短絡保護), 600Vバージョン
FWP-25A22F / FWP-25A22FI (22×58mm FWP aR Cylindrical High-Speed Fuse)
適用機種: FWP-25A22F (no striker) / FWP-25A22FI (with striker)
Basic Electrical Table
| パラメータ | FWP-25A22F | FWP-25A22FI |
| サフィックスの定義 | F = No striker | FI = F + 私, fitted with striker |
| 保護クラス | aR (semiconductor short-circuit protection, 過負荷保護なし) | aR |
| Rated AC Voltage | 700V IEC | 700V IEC |
| Rated DC Voltage | 700ワシントンDCで | 500ワシントンDCで (critical difference!) |
| 定格入力電流 | 25あ | 25あ |
| AC Breaking Capacity | 200kA rms symmetrical | 200kA rms symmetrical |
| DC Breaking Capacity | 50kA @700Vdc | 50kA @500Vdc |
| Pre-arcing I²t | 37 A²·s | 37 A²·s |
| Total clearing I²t (700Vと, pf=0.15) | 530 A²·s | 530 A²·s |
| Power Dissipation @In | 6W | 6W |
| 寸法 | 22×58mm ceramic ferrule fuse | 22×58mm ceramic ferrule fuse |
| 重さ | 62.6g | 61.6g |
| Fuse Holder | JM70100 (compatible with microswitch version) | JM70100 (microswitch version required) |
| 認証 | UL認定済み, CSA, CE, RoHS | UL認定済み, CE, RoHS |
| Striker Function | No fuse alarm output | Striker pops on melting, actuates microswitch for dry contact alarm |
Important Reminder: The FI model is derated to 500V DC. Do not use FI for DC bus >500V; use F version only. For AC operation, both versions have identical characteristics, I²t and time-current curves.
Time-Current (T-C) Characteristic Notes (Datasheet 720026)
Curves shown are nominal melt curves for aR fuses:
- Almost no operation under low-magnitude overload: aR is designed exclusively for semiconductor short-circuit protection, not conventional overload protection. Melting time is extremely long at 1.6×In (40あ), so it cannot be relied on for overload protection.
- Short-circuit region (約. 10×イン): Fast current-limiting melting with low I²t to protect IGBT/SCR. This is its intended operating range.
- Reference melt points (shared by FWP-25A22F / FI):
100あ: Melting time ~10ms
250あ: Melting time ~1ms
>500あ: Sub-millisecond current-limiting operation
Curve feature: The T-C curve of aR fuse is very steep. It operates extremely fast under large short-circuit current while tolerating low multiple overloads for a long time.
The original T-C diagram is log-log plotted. F and FI of the same current rating share identical melt curves; differences are limited to DC voltage rating and striker construction.
I²t Correction Rule (Mandatory for Semiconductor I²t Coordination Check)
の 530 A²·s value above is total clearing I²t under 700V AC, 力率 0.15.
When operating voltage is lower than 700V AC, actual total clearing I²t reduces, multiplied by correction factor K:
Eg=700Vac → K=1.0
Eg=600Vac → K≈0.82
Eg=480Vac → K≈0.64
DC I²t verification cannot directly reuse AC I²t values. Separate DC curve check is required, especially for FI limited to 500Vdc.
Striker FI Wiring & Fuse Holder Description
JM70100 has two configurations:
- Standard JM70100: For F version only, no microswitch
- JM70100 + microswitch module: For FI version. Striker triggers microswitch, typically 1NO+1NC for PLC alarm or trip interlock.
⚠️ The striker provides only a mechanical alarm signal. It does not change fuse protection characteristics or increase breaking capacity.
FWP-25A22F vs FWP-25A22FI Application Selection Table
| アプリケーションシナリオ | 推奨モデル | 理由 |
| DC bus 550~700V (エネルギー貯蔵, PV DC side) | FWP-25A22F | FI limited to 500V DC, not permitted above |
| AC 690V frequency converter / rectifier, alarm required | FWP-25A22FI | Same AC parameters + alarm function |
| AC application, no fault signal required, コスト重視の | FWP-25A22F | 低コスト, simpler construction |
| DC ≤500V with fuse trip reporting | FWP-25A22FI | Meets DC voltage and alarm requirement |
調整 & 交換ガイドライン (Engineering Reference)
- Semiconductor protection check sequence: Device withstand I²t ≥ fuse corrected total clearing I²t
- Do not replace with gG general-purpose fuses; gG has much higher I²t and may destroy IGBTs.
- Domestic replacement must satisfy three criteria: 22×58mm size, aR class, 700Vdc rating (if DC circuit), and I²t close to 530. Many domestic aR fuses are only rated 500Vdc and cannot directly substitute F version.
- Temperature derating: 25A rating is based on 25℃ ambient temperature. Derate to 0.85In typically for 40℃ cabinet ambient.
FWP-25A22FA (FWP-25A22F, aR 700VAC/700VDC, 25あ) 適用範囲
コアの位置決め: aR high-speed semiconductor short-circuit fuse, low I²t current-limiting protection for IGBT, SCR, diode power devices, 過負荷保護なし.
- Original Datasheet Listed Applications
- DC Common Bus
Shared DC bus for multi-drive systems, busbar short-circuit protection. Widely used in energy storage, multi-servo and multi-inverter common-bus schemes. 700Vdc rating supports high-voltage DC bus.
- DC Drives
DC motor drives, high-power DC speed controllers, short-circuit protection for rectifier bridges and SCR thyristors.
- Power Converters / Rectifiers
AC-DC rectifier modules, SCR rectifier cabinets, アクティブ / passive rectifier units.
- Reduced Voltage Solid-State Starters
Thyristor circuit short-circuit protection inside solid-state soft starters.
- Extended Industry Applications
PV & エネルギー貯蔵
PV inverter DC side, string inverter power loops
PCS DC bus, post battery cluster power circuit protection (≤700Vdc)
アドバンテージ: 700Vdc rating, strong DC breaking capacity, low I²t, ideal for DC side.
Variable Frequency & サーボドライブ
690V class three-phase inverter rectifier and IGBT module protection
High-power servo drives, multi-axis servo DC bus
Crane, 冶金, conveyor multi-drive common DC bus systems
UPS & 産業用電源
Industrial online UPS, bidirectional DC/DC converters
High-frequency switching power supplies, 電気めっき & electrolysis power supplies
High-power SSR solid-state relay circuit protection
溶接 & Special Power Supplies
Inverter welding machines, plasma power supplies, high-frequency heat treatment power supplies, IGBT power board protection
Other Power Electronic Equipment
Active Power Filter APF, Static Var Generator SVG power modules
Energy feedback units, ブレーキユニット (braking IGBT protection)
- Selection Differentiation (F vs FI)
FWP-25A22F (このモデル, no striker): Preferred for DC bus >500V, no alarm demand, コストメリット.
FWP-25A22FI (with striker): For AC or DC ≤500V, when fuse alarm, PLC interlock and fault reporting are required.
- 禁止されているアプリケーション
- General distribution circuits, 点灯, 暖房負荷 (aR does not protect overload; low overload will not melt and may damage downstream equipment)
- 直流電圧 >700V
- Circuits requiring overload protection without separate thermal / electronic overload protection
- Direct replacement of gG distribution fuses (gG high I²t risks IGBT destruction)
Eaton Bussmann FWP Cylindrical High-Speed Fuse List (22×58mm series, matching FWP-25A22FA)
注記: A = aR (semiconductor short-circuit, 700VAC/700VDC); G = gR (フルレンジ, 過負荷 + 短絡, 690VAC); suffix F = no striker, FI = with striker. FA in trade name refers to original F; AMPxx is only current marking.
- FWP-xxA22F / FWP-xxA22FI (aR, 700VAC/700VDC, 22×58mm)
| 定格電流 | No Striker Model | With Striker Model | Pre-arcing I²t | Total I²t @700VAC | Power Dissipation W |
| 20あ | FWP-20A22F | FWP-20A22FI | 22 | 310 | 5.2 |
| 25あ | FWP-25A22F | FWP-25A22FI | 37 | 530 | 6 |
| 32あ | FWP-32A22F | FWP-32A22FI | 55 | 780 | 8 |
| 40あ | FWP-40A22F | FWP-40A22FI | 68 | 960 | 12 |
| 50あ | FWP-50A22F | FWP-50A22FI | 155 | 2200 | 12.5 |
| 63あ | FWP-63A22F | FWP-63A22FI | 280 | 4000 | 15 |
| 80あ | FWP-80A22F | FWP-80A22FI | 550 | 7800 | 15 |
| 100あ | FWP-100A22F | FWP-100A22FI | 1100 | 15600 | 16.5 |
⚠️ FI version DC rating derated to 500V. Do not use FI for DC >500V; use F version.
- FWP-xxG22F / FWP-xxG22FI (gR, 690VAC, 22×58mm, 過負荷 + 短絡)
| 定格電流 | No Striker Model | With Striker Model | Pre-arcing I²t | Total I²t @690VAC | Power Dissipation W |
| 20あ | FWP-20G22F | FWP-20G22FI | 26 | 165 | 4 |
| 25あ | FWP-25G22F | FWP-25G22FI | 43 | 274 | 3.7 |
| 32あ | FWP-32G22F | FWP-32G22FI | 97 | 616 | 4.9 |
| 40あ | FWP-40G22F | FWP-40G22FI | 180 | 899 | 4.5 |
| 50あ | FWP-50G22F | FWP-50G22FI | 283 | 1362 | 6.3 |
| 63あ | FWP-63G22F | FWP-63G22FI | 516 | 2575 | 7.4 |
| 80あ | FWP-80G22F | FWP-80G22FI | 1092 | 5448 | 8.4 |
| 100あ | FWP-100G22F | FWP-100G22FI | 2065 | 10300 | 9.4 |
- Other FWP Cylindrical Ferrule Sizes
- 10×38mm: FWP-xxA10F / FWP-xxG10F, current range 4~32A
- 14×51mm: FWP-xxA14F / FWP-xxG14F, current range 4~50A
Protection class aR / gR same as above; 電圧: 700V(aR) / 690V(gR)
- Other Eaton Bussmann High-Speed Semiconductor Fuse Series (Bolt / Blade Style, 大電流)
FWP (bolt-on): 700V, 35~600A, aR, busbar and high-power converter
FWJ: 1000V, high-voltage DC, PV & energy storage high-power
FWH: 1000Vdc high-voltage DC fuse
FWA: 500V, small cylindrical high-speed
FWX: 250V, North American blade high-current
DFJ: Drive dedicated high-speed fuse
- Matching Fuse Holders (22×58)
JM70100: Standard holder (for F version)
JM70100 + microswitch module: For FI striker version, dry contact alarm output
- Model Code Summary
FWP Current + A/G + Size Code + F/FI
FWP: Bussmann IEC high-speed semiconductor fuse
あ: aR (short-circuit only, IGBT/SCR protection)
G: gR (フルレンジ, 過負荷 + 短絡)
22 = 22×58mm; 14 = 14×51mm; 10 = 10×38mm
F: No striker; FI: With striker
コンタクタ,サーキットブレーカー,センサー,エンコーダ,PLC,コンバータ



















NH42-63-318x560.png)