NMB-MAT 3115RL-05W-B60 DC24V Industrial Axial Fan - コンタクタ,サーキットブレーカー,ソーラーインバーター,センサー,エンコーダ,PLC

微信: +86-13184948252 ワッツアップ: 0086-13811255435 電子メール: kent@bestcontactor.com

について 接触 |

NMB-MAT 3115RL-05W-B60 DC24V Industrial Axial Fan - コンタクタ,サーキットブレーカー,ソーラーインバーター,センサー,エンコーダ,PLC

電気/

NMB-MAT 3115RL-05W-B60 DC24V Industrial Axial Fan

寸法: 80×80×38mm (8038), Dual-ball bearing, 2-wire version (power supply only, no tachometer feedback). Widely used for cooling inverters, servo drives and industrial control cabinets. Core Electrical Specifications Item Parameter Model 3115RL‑05W‑B60 Rated Voltage DC 24V (動作範囲:14‑27.6V) Rated Current 0.5A (Typical 0.4A) Power 9.6‑12W Speed 5500RPM Airflow 79.2CFM ≈134.6m³/h Static Pressure 180Pa Noise 51dB(あ) Bearing Dual‑ball ...

  • 製品詳細

寸法: 80×80×38mm (8038), Dual-ball bearing, 2-wire version (power supply only, no tachometer feedback). Widely used for cooling インバータs, サーボドライブ and industrial control cabinets.

コアの電気仕様

アイテムパラメータ
モデル3115RL‑05W‑B60
定格電圧DC 24V (動作範囲:14‑27.6V)
定格電流0.5あ (Typical 0.4A)
9.6‑12W
スピード5500回転数
Airflow79.2CFM ≈134.6m³/h
Static Pressure180パ
ノイズ51dB(あ)
ベアリングDual‑ball bearing
L10 Life50000h @25℃
配線2‑wire: Red=24V+, Black=GND‑
重さ210g

⚠️Suffix Distinction (Easily Confused within the Series)

B60: 2-ワイヤー, no tachometer feedback

B69: 3-ワイヤー, with tachometer (TACH) speed feedback

B66: 4-ワイヤー, PWM speed control + tachometer feedback

取付寸法

Flange cutout: 71.5×71.5 mm

取付穴: M4ネジ, hole pitch 71.5mm

厚さ: 38mm

アプリケーションシナリオ

Cooling for inverters (例えば. ABB ACS880), サーボドライブ, high-power power supplies and industrial equipment enclosures.

OEM Status: NRND (Not Recommended for New Designs). Recommended replacement part number: 08038RA-24P-EA-00.

互換性 & Sourcing Criteria for Domestic Alternatives

All conditions must be satisfied simultaneously:

  1. Form factor 80×80×38mm
  2. DC24V, rated current ≥0.45A, speed 5200-5600RPM
  3. Dual-ball bearing
  4. Matching wiring: Do NOT select 2-wire B60 variant if equipment requires speed-monitoring signal.

故障診断

  1. Fan does not spin upon power-on: Verify 24V input voltage. Manually spin impeller when power is cut off. If locked-up, bearing damage has occurred; replace directly.
  2. 低速 & 異音: Bearing wear. Do not attempt repair in industrial environments; replace the fan.
  3. Important note: B60 is a 2-wire fan without tachometer alarm output. If host equipment reports fan fault, the original unit requires B69 (3-wire tachometer version). B60 cannot be used as a drop-in replacement.

Replacement List for NMB 3115RL-05W-B60 (8038-24V-2-wire)

Key parameters of original fan: 80×80×38mm|DC24V|0.5A|5500RPM|Dual-ball bearing|2-wire no tach feedback|71.5mm mounting pitch

⚠️Critical Reminder: If the inverter triggers fan fault alarm, original hardware requires 3-wire tachometer B69. Do not apply 2-wire B60 or any 2-wire substitutes.

  1. OEM Direct Replacement (NMB)
モデル配線備考
08038RA‑24P‑EA‑002‑wireOfficial NRND upgrade part. Fully form‑fit‑function compatible, direct drop‑in replacement for 3115RL‑05W‑B60
  1. デルタ / Sunon Foreign-brand Compatible Models
モデル電圧現在スピード配線備考
PFB0824GHE24V0.54あ5400回転数2‑wireデルタ, high static pressure, widely used as inverter replacement
PF80382B1‑000C‑A9924V0.5あ5500回転数2‑wireSunon, dual‑ball bearing, perfectly matched dimensions
  1. Domestic Industrial Alternatives (General for Inverters & 制御盤)
モデル電圧現在スピード配線特徴
SJ8038HD2‑2424V0.5あ5400‑5600RPM2‑wireDual‑ball bearing, wide‑temperature, common spare part for domestic inverters
RD8038B24H24V0.5あ5500回転数2‑wireRUNDA, copper‑winding dual‑ball bearing, cost‑effective option
FS8038‑24‑05024V0.5あ5500回転数2‑wireIndustrial‑grade domestic fan, built‑in reverse‑connection protection

✅Mandatory Checklist Prior to Replacement

  1. Form factor: 80×80×38mm, mounting hole pitch 71.5mm for M4 screws
  2. ベアリング: Dual-ball bearing is mandatory. Sleeve bearings have short service life and are not recommended for industrial sites.
  3. DC24V power supply, rated current ≥0.45A. Insufficient current causes insufficient airflow and over-temperature protection.
  4. Wiring specification: 2-ワイヤー: Red=24V+, Black=GND-. If equipment has fan fault alarm function, select 3-wire model with TACH tachometer output.
  5. Speed range: 5200-5600回転数. Too low speed yields insufficient static pressure & airflow, triggering inverter over-temperature tripping.

⚠️Common Pitfalls

  1. 8025 (25 mm thickness) cannot replace 8038. Thickness difference of 13 mm prevents installation.
  2. Avoid low-current 0.3A variants; insufficient airflow and static pressure will cause high-temperature alarms.
  3. B60 is 2-wire without speed feedback. Some ABB ACS880 units are factory-fitted with B69 (3-wire tachometer). Direct installation of B60 will trigger fan fault alarms.

Typical Application Scenarios of NMB 3115RL-05W-B60 (DC24V 8038 2-ワイヤー)

コア機能: High static pressure, 5500回転数, dual-ball bearing, 2-wire without tach feedback, DC24V supply. Suitable for forced cooling inside equipment with high-resistance air ducts. Not applicable for systems requiring fan-fault alarm.

  1. Inverters (Most Common Deployment)
  2. Internal cooling fans for certain high-power Schneider inverters, power range 7.5-30 kW air duct cooling.
  3. Post-mounted cooling fans for high-power domestic inverters (革新, 招待, Delta etc.), for models without fan-speed monitoring.

⚠️Note: ABB ACS880 is mostly factory-equipped with B69 (3-wire tachometer). B60 cannot be directly substituted, otherwise fan fault alarm will occur.

  1. サーボドライブ / Motion Control Units
  2. Internal power-module cooling for high-power multi-axis servo units;
  3. Air duct cooling for numerical-control drive units and machine-tool servo control cabinets.

Applicable condition: Equipment only supplies power to fan, no fan-speed detection & alarm function.

Ⅲ. Industrial Power & Power-Electronic Equipment

  1. High-power DC24V industrial switching power supplies & charging modules;
  2. Power-cavity cooling for medium-small UPS uninterruptible power supplies;
  3. Auxiliary cooling for energy-storage converters and compact energy-storage modules;
  4. Power-device cooling for high-frequency welders and plasma power sources.
  5. Industrial Chassis & 制御盤
  6. Exhaust ventilation inside compact industrial control cabinets;
  7. Forced ventilation for industrial IPC & industrial host chassis;
  8. Auxiliary cooling inside robot control cabinets.

24 VDC input, can be directly driven by PLC 24V power supply, no extra AC-DC converter required.

  1. Other Industrial Equipment
  2. Laser equipment: Cooling for laser power supplies and laser controller enclosures;
  3. Industrial medical equipment: Power-module cooling for non-life-support industrial medical instruments;
  4. Rail-transit equipment: Cooling for on-board control boxes and vehicle-mounted power modules;
  5. Stage-lighting equipment: Internal cooling for high-power moving-head beam lights;
  6. 自動化装置: Control-box cooling for textile, printing and packaging machinery.

✅Key Engineering Application Restrictions

  1. B60 is 2-wire with no tachometer feedback. Never select B60 if host equipment implements fan-fault alarm; choose B69 (3-wire tachometer) variant instead.
  2. High-static-pressure characteristic: Optimized for air ducts with radiators, baffles and filter screens. For open cabinet ventilation, low-static-pressure general-purpose fans are acceptable.
  3. 電源: DC24V only. Do NOT connect to AC220V. Allowable operating voltage:14-27.6V.
  4. OEM lifecycle status: NRND (Not Recommended for New Designs). For new-project design, use official replacement part 08038RA-24P-EA-00.

Service Life of NMB 3115RL-05W-B60 Fan

This fan adopts dual-ball bearing. NMB official datasheet specifies:

50000 hours @25℃ free-air condition (L10 life).

Definition of L10 Life

L10 life: Statistically, 90% of fans within a batch can achieve this runtime; 10% will fail earlier. It is NOT a guaranteed service life for every single unit.

Expected Service Life under Different Operating Conditions

動作環境Expected Service Life備考
25℃, クリーン & low‑dust, continuous running40000‑50000hLab ideal condition
40‑50℃, industrial cabinet, moderate dust20000‑30000hTypical working condition for inverter & servo cabinets
>60℃ high temperature, 重い粉塵 & オイルミスト8000‑15000hSignificant life reduction; premature bearing wear, noise and speed drop
Intermittent start‑stop operationRelatively extended lifeLess bearing wear with fewer start‑stop cycles

Reference conversion: 50000 h continuous operation ≈ 5.7 years of 24-hour non-stop runtime. Industrial field conditions rarely reach theoretical rating; noise degradation is commonly observed after 3-4 years of service.

Typical Failure Symptoms

  1. Increased noise & abnormal rattling (ball-bearing wear)
  2. Speed drop, degraded airflow & static pressure, triggering system over-temperature alarms
  3. Hard to start; fan requires manual spin-up upon power-on, eventually locks up completely.

Practical Engineering Recommendations

  1. For continuously-running industrial equipment, perform preventive replacement every 2-3 年. Avoid unplanned shutdown caused by fan seizure and consequent inverter over-temperature tripping.
  2. Install filter screens for dusty cabinet environments and conduct regular dust removal to extend fan service life.
  3. This model is NRND. New-project design shall adopt replacement part 08038RA-24P-EA-00, updated bearing process with identical life rating.

Supplementary Comparison

Equivalent-size sleeve-bearing fans: Typical service life 8000-15000 h, not recommended for industrial deployment.

B69 (3-wire tachometer version) shares identical bearing hardware with B60, same theoretical service life, only adds tachometer circuit.

Real-world Engineering Application Cases of NMB 3115RL-05W-B60 (2-wire 24V 8038)

Important premise: B60 is 2-wire fan without tachometer feedback. Only deploy in equipment without fan-speed detection & 故障警報. Systems with fan-fault protection require B69 (3-wire tachometer), direct substitution is invalid.

  1. Inverter Sector (Most Frequently Encountered in Teardowns)

Case 1: Cooling for 15-18.5 kW Domestic Inverters

装置: イノベーションMD380, Invt CHV series high-power inverters, selected Delta high-power inverters

Operating condition: 24-hour continuous operation for textile & injection-molding machines. High-resistance radiator air duct requiring high static-pressure fan. Equipment does not monitor fan speed, powered directly by internal DC24V supply.

Failure phenomenon: After 3-4 years runtime, bearing wear causes abnormal noise and airflow reduction, triggering inverter over-temperature shutdown. Issue resolved by replacing with 3115RL-05W-B60 or domestic equivalent.

⚠️ABB ACS880 is factory-equipped with B69 (3-wire tachometer). B60 direct swap triggers fan fault alarm.

Case 2: Low-power hoist / lifting-machine inverters

-装置: 11-22 kW hoist-dedicated inverters deployed in overhead cranes & lifting-mechanism control cabinets.

-Operating condition: Heavy-dust site with mixed intermittent-continuous operation. Fan mounted rear-side of power-module radiator for forced draw-through cooling.

  1. サーボ & Numerical-control Equipment Cases

Case 3: High-power multi-axis servo drives (no fan-monitoring variant)

-装置: Domestic multi-axis servo units, machine-tool servo control cabinets; no fan-speed monitoring programmed in controller firmware.

Operating condition: Cabinet ambient temperature 40-50 ℃ inside CNC lathe & machining-center control enclosures. Fan provides forced cooling for servo power boards and IGBT power modules.

Repair scenario: Seized fan causes servo-module over-temperature & power derating; service restored after B60 replacement.

Case 4: Legacy CNC system power-supply units

装置: Older-generation machine-tool high-power power-supply boxes with internal DC24V power rail.

特徴: Equipment only supplies power to fan without speed reading; 80×80×38 mounting footprint accepts this fan directly.

Ⅲ. Power-supply Sector Cases

Case 5: Industrial high-power DC24V charging-power modules

装置: Automation-equipment charging power supplies, welder power supplies, plasma-cutting power sources.

Operating condition: Metal-dust-laden welding-shop environment. Fan installed behind radiator, high static pressure overcomes filter-screen and duct resistance.

Case 6: Medium-small-size industrial UPS

装置: 5-10 kVA industrial UPS units for internal power-component cooling.

特徴: Powered directly from UPS internal 24 VDC busbar; no additional AC-DC conversion required.

  1. Cabinet & Automation-equipment Cases

Case 7: Auxiliary cooling for robot secondary control cabinets

装置: External expansion control cabinets for robots (not robot native built-in fans).

Operating condition: Production-line cabinet exhaust ventilation. Driven by PLC DC24V power supply, pure exhaust function without fault-detection logic.

Case 8: Laser-equipment power-supply enclosures

装置: Fiber-laser power supplies and laser-controller cabinets.

Operating condition: Smoke-laden laser-processing workshops. Fan pushes air through filter screens for power-component cooling. High static pressure and dual-ball long-life are critical requirements.

  1. Other-industry Real-world Cases

Case 9: High-power stage-lighting equipment

装置: High-power beam moving-head lights, internal power-module cooling.

Operating condition: High-temperature high-vibration venue environment; dual-ball bearing provides vibration resistance, DC24V power input.

Case 10: Rail-transit on-board control cabinets

装置: Vehicle-mounted electrical cabinets and metro auxiliary control modules (non-safety-critical loops).

Operating condition: 14-27.6 V wide-voltage input accommodates vehicle-bus voltage fluctuation. Dual-ball bearing tolerates bump and vibration.

📌Real-world Maintenance Pitfall Case

Fault scenario: Maintenance technician replaces factory-fitted B69 (3-wire tachometer) with B60 (2-ワイヤー) on ABB ACS880 inverter. Fan-fault alarm activates upon power-on and equipment refuses to run.

Root cause: B60 provides no tachometer-feedback signal for inverter speed detection.

解決: Install B69 variant. Disabling fan-fault detection in firmware is possible but not recommended, as thermal protection is lost.

Project-sourcing Reference

  1. Spare-part replacement for legacy equipment: Use same B60 part number if original unit is B60.
  2. New-project design: Model is NRND, prioritize official replacement 08038RA-24P-EA-00.
  3. If equipment has fan-fault alarm function: B60 is strictly prohibited, select B69 (3-wire tachometer).

Additional Industrial Applications for NMB 3115RL-05W-B60 (Excluding Inverters, Servos & CNC装置)

Core premise: 2-wire without tachometer feedback; host equipment must have no fan-fault alarm function. High-static-pressure 8038 DC24V dual-ball-bearing fan optimized for filter-screen & radiator-restricted air ducts.

1️⃣ Laser-processing Equipment

  1. Fiber-laser power supplies & YAG laser power boxes: Power-component cooling for laser cutters & laser markers. Overcome smoke-filter-screen resistance for 24-7 factory-continuous operation. Equipment only supplies power, no fan-speed detection.
  2. Laser-welding-machine control cabinets: Forced air-cooling for laser-driver modules, deployed in metal-dust-heavy sheet-metal-processing workshops.

Maintenance case: Bearing wear reduces airflow and degrades laser-output power; performance restored after B60 replacement.

2️⃣ Welding & Plasma-cutting Equipment

  1. Inverter plasma-cutting power supplies: IGBT radiator cooling for metal-dust-rich workshop environments. High static pressure penetrates dust-proof screens.
  2. Industrial inverter welders & high-frequency induction-heating power supplies: High-power solid-state-component cooling via on-board DC24V supply.

3️⃣ Power-supply, Energy-storage & UPS Industry

  1. High-power industrial DC-DC switching power supplies & charging modules: Internal cooling for automation-equipment power supplies and electronic-load test benches.
  2. Medium-small-size industrial UPS (5-10 kVA): Power-cavity cooling powered directly by UPS internal 24 VDC busbar.
  3. Compact energy-storage modules & residential energy-storage converter auxiliary cooling: Apply only to non-safety-critical circuits without fan-diagnostic logic.

4️⃣ Industrial Chassis & Robot Auxiliary Electrical Cabinets

  1. Industrial IPC & compact sealed industrial chassis: Internal exhaust ventilation for filter-equipped enclosures.
  2. Robot external expansion control cabinets (not robot native internal fans): Exhaust ventilation for production-line robot auxiliary cabinets, driven by PLC DC24V power supply.
  3. ATE test-equipment cabinets & automated-test platforms: Power-module cooling for automatic-test-system hardware.

5️⃣ Rail-transit & Vehicle-mounted Industrial Equipment (Non-safety-critical Loops)

  1. 地下鉄 / train auxiliary on-board control boxes and vehicle-mounted signal peripheral cabinets: 14-27.6 V wide-voltage range accommodates vehicle-bus voltage fluctuation; dual-ball bearing resists mechanical shock and vibration.

注記: Safety-relevant on-board hardware normally specifies B69 tachometer variant. B60 is limited to non-safety-critical circuits.

6️⃣ Stage-lighting & Audio-visual Equipment

  1. High-power beam moving-head lights & stage high-power LED luminaire power compartments: High-vibration venue environment; dual-ball bearing anti-vibration performance, DC24V power supply.
  2. High-power industrial power amplifiers & public-address power-amplifier enclosures.

7️⃣ Semiconductor & SMT Automation Equipment

  1. SMT pick-and-place machine auxiliary power boxes & PCB-inspection-equipment electrical enclosures: Sub-module cooling (main-unit fans use dedicated tachometer-equipped variants).
  2. Dispensing machines & spray-coating-equipment control-box cooling.

8️⃣ Other Specialized Industrial Equipment

  1. 印刷 & textile-machinery electrical cabinets: Power-unit cooling inside printing presses and warp-knitting-machine control enclosures.
  2. Laboratory high-power instrumentation: High-power electronic loads and burn-in-test benches.
  3. Packaging-machinery electrical cabinets.

⚠️Hard Sourcing Rules for Engineering Practice

  1. B60 is 2-wire and has no speed-signal output. Never deploy B60 for any equipment with fan-fault-alarm or fan-stall-detection logic; select B69 (3-wire tachometer) instead.
  2. Prefer this fan for air ducts fitted with radiators and filter screens. Low-static-pressure general-purpose fans suffice for open unrestricted-airflow cabinet ventilation.
  3. OEM lifecycle status: NRND. New-project design prioritizes official replacement part 08038RA-24P-EA-00.
  4. For dusty / oil-mist industrial environments, schedule preventive replacement every 2-3 years to avoid unexpected equipment over-temperature shutdown.

前へ:

返信を残す

伝言を残す