モデルコードの内訳
MY2N-GS DC24V
- MY: Miniature General-Purpose Power Relay シリーズ
- 2: 2 極 (DPDT, 2いいえ + 2ノースカロライナ州, 2 Form C contacts)
- N: Equipped with built-in LED operation indicator and mechanical status window (green LED for DC coils)
- GS: Upgraded new generation; direct drop-in replacement for discontinued MY2N-J
- DC24V: Rated coil voltage DC 24 V
Extended variants:
MY2N-D2-GS DC24V: 内蔵フリーホイールダイオード (suppresses coil back EMF, ideal for direct PLC driving)
MY2IN-GS: Equipped with locking test lever for circuit inspection; Suffix -R denotes export version with fully compatible pin layout
- コアの電気仕様
2.1 コイルパラメータ (DC24V)
定格電圧: 直流 24 V
コイル消費電力: 0.7 W
Coil resistance (@23℃): ≈662 Ω
Operate voltage: ≤80% of rated voltage (≤19.2 VDC)
解除電圧: ≥10% of rated voltage (≥2.4 VDC)
Allowable voltage fluctuation range: 21.6~26.4 VDC
2.2 Contact Ratings (抵抗負荷, Nominal 5A)
接点構成: 2 sets of Form C changeover contacts (DPDT)
接点材質: Silver (Ag)
Rated switching capacity:
✅ 5A / 250Vと
✅ 5A / 30ワシントンDCで
Maximum continuous carry current: 10あ (static steady-state conduction; frequent switching not recommended)
Minimum applicable load: 1ミリアンペア / 5VDC (suitable for low-level signal circuits)
Maximum switching capacity: 1100バージニア州 (交流); 120W (直流)
2.3 耐用年数
機械的寿命: 50 100万操作 (18,000 サイクル/時間)
電気的寿命 (@5A resistive load): ≥500,000 operations (2,400 サイクル/時間)
Operate time ≤15ms; Release time ≤5ms
2.4 絶縁耐力 & 絶縁
Coil ↔ Contacts: 2000Vと / 1 分
Contacts of different poles: 2000Vと /1 分
NO and NC contacts within the same pole: 1000Vと /1 分
Insulation resistance ≥1000 MΩ (measured at 500VDC)
- ピンの定義 (Standard 8-pin plug-in layout)
Compatible sockets: PYF08A-E / PYFZ-08-E
ピン 13, 14: コイル端子 (non-polarized for standard MY2N-GS; Polarity required for D2 version: Pin14=Positive, Pin13=Negative)
1st contact set: 9 (COM common), 1 (NC Normally Closed), 5 (NO Normally Open)
2nd contact set: 12 (COM common), 4 (NC Normally Closed), 8 (NO Normally Open)
Wiring principle: Energize coil pins 13-14 → 9-5 & 12-8 近い; Power off → restore NC path 1-9 & 4-12
- Compatible Socket List
| Socket Model | 端子の種類 | 取付方法 | 備考 |
| PYF08A-E | M3ネジ端子 | DINレール / ネジ取付 | Most widely used standard domestic socket |
| PYFZ-08-E | Finger-safe screw terminals | DINレール | Preferred for control cabinet safety design |
| PYF-08-PU | Spring push-in terminals (工具不要) | DINレール | Improves wiring efficiency |
Optional accessory: PYC-A1 locking clip (prevents relay loosening under vibration)
- Ambient Operating Limits
動作温度: -40℃~+70℃ (結露しないこと, no icing)
保管温度: -55℃~+70℃
Humidity range: 5%~95%RH; condensation and long-term moisture ingress prohibited
Unsuitable environments: ひどい粉塵, 腐食性ガス, sustained severe vibration
- 選定ガイドライン & Critical Restrictions
- 誘導負荷 (電磁弁, 接触器コイル)
Standard MY2N-GS has no built-in surge suppression. For DC inductive loads, select MY2N-D2-GS with integrated diode. Fit external RC snubber circuits for AC inductive loads, otherwise rapid contact erosion will occur.
- Overload forbidden
5A is the rated switching current. Avoid switching loads exceeding 6A continuously. Derate for motors and lighting loads with high inrush current.
- Do not drive coil via high-frequency PWM
Continuous PWM switching causes contact chatter and burnout. Select SSR solid-state relays for high-frequency control scenarios.
- Never mix AC & DC coil models
Powering DC coil relays with AC voltage leads to overheating and permanent damage; AC coil relays fail to pull in under DC supply.
- Not applicable for safety circuits
No forced guided contacts. Use dedicated safety relays such as G9SX for emergency stop and safety interlock loops.
- 典型的なアプリケーションシナリオ
PLC signal expansion, pneumatic solenoid valve control, small contactor driving, control cabinet logic interlock, lighting circuit switching, signal transfer on automated production lines.
- Drop-In & アップグレードの代替案
- Direct replacement for legacy model: MY2N-J DC24V (identical pin layout and compatible sockets)
- Built-in freewheeling diode upgrade: MY2N-D2-GS DC24V
- 4-contact variant within the same series: MY4N-GS DC24V (14-pin socket PYF14A-E required)
Application Industry & Scenario Overview: OMRON MY2N-GS DC24V 5A
コアの位置決め: DC24V controlled intermediate relay with 2 切替接点 (DPDT). Mainly used for signal transfer after PLC outputs and low-power load switching; rated 5A/250VAC contacts, suitable for low-voltage control of high-voltage circuits.
Limitation reminder: Cannot be used as safety relay; not fit for high-frequency switching, high-inrush loads, explosive or heavily corrosive environments.
- 産業オートメーション (Largest Application Field)
- Custom automation equipment
コンベヤシステム, transfer modules, stop cylinder control, directional switching for small pneumatic solenoids; signal interlock for photoelectric and proximity sensors, indicator light control.
- 工作機械
CNC auxiliary indicator lamps, lubrication pump on/off, door limit signal transfer, cooling fan control, auxiliary loops for tool changers.
⚠ Machine tools contain many inductive loads (電磁弁). MY2N-D2-GS (built-in diode) is recommended to protect contacts and PLC modules.
- 包装 & 印刷機械
Case sealers, ラベラー, film winding mechanisms, small actuator switching, alarm buzzers and signal light circuits.
- ゴム & Plastic Injection Auxiliary Equipment
Hopper heating fans, material level alarm, signal transfer for conveyor start/stop control.
- 空調設備 & ビルディングオートメーション
Central air-conditioning control cabinets: エアダンパーアクチュエーター, differential pressure alarms, auxiliary fan control, anti-freeze protection signal interlock
Fresh air systems, 排気ファン, cooling tower auxiliary circuits
Zone lighting control; fire alarm signal transfer (only signal relay, NOT main fire protection circuit)
- ロジスティクス & Warehousing Equipment
Automated warehouses, 仕分けコンベヤライン, peripheral control cabinets for AGVs
コンベヤ, sorting baffle cylinder control, logic expansion for photoelectric sensors
Indicator lights and alarm driver for warehouse access control
- 水処理 & 環境設備
投与システム, auxiliary control of small water pumps, high/low level signal transfer, aeration fan auxiliary circuits, signal switching for online water quality monitoring cabinets.
Environmental note: Anti-condensation treatment is mandatory inside humid cabinets to prevent contact oxidation and poor connectivity.
- エネルギー, EV Charging & PV Auxiliary Cabinets
- Auxiliary fault alarm and cooling fan control for small PV combiner boxes
- Signal transfer inside AC charging station control boards, fault indicator lights and auxiliary contactor coil driving
Forbidden: Do NOT switch high-voltage DC main circuits; only permitted for low-voltage control loops.
- Food Machinery & Central Kitchen Equipment (Key Target Segment)
Vegetable washing equipment, コンベア, small exhaust fans, warning lights
Smart Canteen & Central Kitchen Electrical Cabinets: Alarm signal for transparent kitchen monitoring, automatic door control, auxiliary ventilation control, solenoid valve drive for cleaning machines
✅ Advantage: DC24V is standard industrial voltage, unified with HMI, PLC and sensor power supply, supporting standardized cabinet wiring.
- Rail Support & Off-Highway Mobile Equipment
Onboard control cabinets for construction machinery, small tunnel ventilation control boxes, barrier and gate control cabinets; access control lock and traffic light drivers.
Vibration warning: Fit PYC-A1 locking clip to avoid relay disconnection.
- 研究室 & Testing Instruments
Aging test equipment, thermostats, small test fixtures; 電磁弁, low-power heating loads and alarm signal switching.
Compatible Load Classification
✅ Recommended Loads
- DC24V miniature solenoid valves, インジケーターランプ, ブザー
- 220VAC small fans, lighting loads, AC contactor coils
- Passive dry contact signal transmission
❌ Not Recommended / Strictly Forbidden Loads
- High-power motors and heating elements (inrush current far exceeds 5A rating)
- Loads with switching frequency >10 cycles/minute (accelerates contact wear)
- Hazardous explosive zones (no explosion-proof certification)
- Safety interlock and emergency stop circuits (use dedicated safety relays e.g. G9SX)
Selection Matching Advice
- Driven by PLC transistor outputs → Priority: MY2N-D2-GS (built-in diode, prevents back EMF damage to PLC)
- Driven by relay-output PLC → Standard MY2N-GS directly applicable
- If driving inductive loads such as contactors and solenoids without diode version, fit external surge absorption components.
取付寸法: OMRON MY2N-GS DC24V (5あ) 公定基準値
- Relay Body (without socket, 8-pin plug-in)
Maximum overall dimension (L × W × H): 28.0 × 21.5 × 36.0 mm
深さ (front-back): ≤28 mm
幅 (left-right): ≤21.5 mm
身長 (excluding pins): ≤36 mm
ピン: 8 cylindrical plug pins, standard 8-pin layout for MY2 series.
- Dimensions of Common DIN-mount Sockets
1) PYF08A-E (Standard widely used socket)
Overall dimension: 72 (D) ×22 (W) ×30 (H) mm
取り付け: 35mm standard DIN rail or screw fixing
Screw mounting holes: 2 個, Φ4.2×5 slotted hole, center distance 44 mm
Terminal screw specification: M3
2) PYFZ-08-E (Finger-safe safety socket)
Overall dimension: 72 (D) ×23 (W) ×31 (H) mm
3) PYF-08-PU (Push-in spring terminal socket)
Overall dimension: 72 ×23 ×31 mm
Reference total height: Relay fully inserted into socket ≈64 mm (for cabinet layout reservation)
- PCB Mount Alternative (Optional PY08-02 soldering socket)
For PCB soldering installation: PY08-02 PCB socket, fully pin-compatible with MY2N-GS.
- Practical Layout Parameters for Control Cabinet Design
- Minimum side-by-side mounting clearance: Can be installed adjacently; single unit occupied width 22 mm. Total width for N units ≈ 22 × N mm
- Vertical cooling clearance recommendation: ≥8mm top & 底; ≥10mm for densely packed arrangements
- Cabinet depth reservation: ≥75mm for socket + relay assembly (avoid interference with cabinet door)
- Vibration-prone applications: Install PYC-A1 locking clip to prevent dislodging.
- Important Remarks
- MY2N-GS shares identical outline dimensions and fully compatible sockets with legacy MY2N-J; direct field replacement supported.
- Narrow width of only 21.5mm, ideal for space-restricted control cabinets.
- Avoid mounting adjacent to contactors and high-power power supplies; elevated ambient temperature shortens contact service life.
コンタクタ,サーキットブレーカー,センサー,エンコーダ,PLC,コンバータ





















NH42-63-318x560.png)