モデルコードの内訳
MY2N-GS DC24V
- MY: Miniature General-Purpose Power Relay シリーズ
- 2: 2 極 (DPDT, 2いいえ + 2ノースカロライナ州, 2 Form C contacts)
- N: Equipped with built-in LED operation indicator and mechanical status window (green LED for DC coils)
- GS: Upgraded new generation; direct drop-in replacement for discontinued MY2N-J
- DC24V: Rated coil voltage DC 24 V
Extended variants:
MY2N-D2-GS DC24V: 内蔵フリーホイールダイオード (suppresses coil back EMF, ideal for direct PLC driving)
MY2IN-GS: Equipped with locking test lever for circuit inspection; Suffix -R denotes export version with fully compatible pin layout
- コアの電気仕様
2.1 コイルパラメータ (DC24V)
定格電圧: 直流 24 V
コイル消費電力: 0.7 W
Coil resistance (@23℃): ≈662 Ω
Operate voltage: ≤80% of rated voltage (≤19.2 VDC)
解除電圧: ≥10% of rated voltage (≥2.4 VDC)
Allowable voltage fluctuation range: 21.6~26.4 VDC
2.2 Contact Ratings (抵抗負荷, Nominal 5A)
接点構成: 2 sets of Form C changeover contacts (DPDT)
接点材質: Silver (Ag)
Rated switching capacity:
✅ 5A / 250Vと
✅ 5A / 30ワシントンDCで
Maximum continuous carry current: 10あ (static steady-state conduction; frequent switching not recommended)
Minimum applicable load: 1ミリアンペア / 5VDC (suitable for low-level signal circuits)
Maximum switching capacity: 1100バージニア州 (交流); 120W (直流)
2.3 耐用年数
機械的寿命: 50 100万操作 (18,000 サイクル/時間)
電気的寿命 (@5A resistive load): ≥500,000 operations (2,400 サイクル/時間)
Operate time ≤15ms; Release time ≤5ms
2.4 絶縁耐力 & 絶縁
Coil ↔ Contacts: 2000Vと / 1 分
Contacts of different poles: 2000Vと /1 分
NO and NC contacts within the same pole: 1000Vと /1 分
Insulation resistance ≥1000 MΩ (measured at 500VDC)
- ピンの定義 (Standard 8-pin plug-in layout)
Compatible sockets: PYF08A-E / PYFZ-08-E
ピン 13, 14: コイル端子 (non-polarized for standard MY2N-GS; Polarity required for D2 version: Pin14=Positive, Pin13=Negative)
1st contact set: 9 (COM common), 1 (NC Normally Closed), 5 (NO Normally Open)
2nd contact set: 12 (COM common), 4 (NC Normally Closed), 8 (NO Normally Open)
Wiring principle: Energize coil pins 13-14 → 9-5 & 12-8 近い; Power off → restore NC path 1-9 & 4-12
- Compatible Socket List
| Socket Model | 端子の種類 | 取付方法 | 備考 |
| PYF08A-E | M3ネジ端子 | DINレール / ネジ取付 | Most widely used standard domestic socket |
| PYFZ-08-E | Finger-safe screw terminals | DINレール | Preferred for control cabinet safety design |
| PYF-08-PU | Spring push-in terminals (工具不要) | DINレール | Improves wiring efficiency |
Optional accessory: PYC-A1 locking clip (prevents relay loosening under vibration)
- Ambient Operating Limits
動作温度: -40℃~+70℃ (結露しないこと, no icing)
保管温度: -55℃~+70℃
Humidity range: 5%~95%RH; condensation and long-term moisture ingress prohibited
Unsuitable environments: ひどい粉塵, 腐食性ガス, sustained severe vibration
- 選定ガイドライン & Critical Restrictions
- 誘導負荷 (電磁弁, 接触器コイル)
Standard MY2N-GS has no built-in surge suppression. For DC inductive loads, select MY2N-D2-GS with integrated diode. Fit external RC snubber circuits for AC inductive loads, otherwise rapid contact erosion will occur.
- Overload forbidden
5A is the rated switching current. Avoid switching loads exceeding 6A continuously. Derate for motors and lighting loads with high inrush current.
- Do not drive coil via high-frequency PWM
Continuous PWM switching causes contact chatter and burnout. Select SSR solid-state relays for high-frequency control scenarios.
- Never mix AC & DC coil models
Powering DC coil relays with AC voltage leads to overheating and permanent damage; AC coil relays fail to pull in under DC supply.
- Not applicable for safety circuits
No forced guided contacts. Use dedicated safety relays such as G9SX for emergency stop and safety interlock loops.
- 典型的なアプリケーションシナリオ
PLC signal expansion, pneumatic solenoid valve control, small contactor driving, control cabinet logic interlock, lighting circuit switching, signal transfer on automated production lines.
- Drop-In & アップグレードの代替案
- Direct replacement for legacy model: MY2N-J DC24V (identical pin layout and compatible sockets)
- Built-in freewheeling diode upgrade: MY2N-D2-GS DC24V
- 4-contact variant within the same series: MY4N-GS DC24V (14-pin socket PYF14A-E required)
Application Industry & Scenario Overview: OMRON MY2N-GS DC24V 5A
コアの位置決め: DC24V controlled intermediate relay with 2 切替接点 (DPDT). Mainly used for signal transfer after PLC outputs and low-power load switching; rated 5A/250VAC contacts, suitable for low-voltage control of high-voltage circuits.
Limitation reminder: Cannot be used as safety relay; not fit for high-frequency switching, high-inrush loads, explosive or heavily corrosive environments.
- 産業オートメーション (Largest Application Field)
- Custom automation equipment
コンベヤシステム, transfer modules, stop cylinder control, directional switching for small pneumatic solenoids; signal interlock for photoelectric and proximity sensors, indicator light control.
- 工作機械
CNC auxiliary indicator lamps, lubrication pump on/off, door limit signal transfer, cooling fan control, auxiliary loops for tool changers.
⚠ Machine tools contain many inductive loads (電磁弁). MY2N-D2-GS (built-in diode) is recommended to protect contacts and PLC modules.
- 包装 & 印刷機械
Case sealers, ラベラー, film winding mechanisms, small actuator switching, alarm buzzers and signal light circuits.
- ゴム & Plastic Injection Auxiliary Equipment
Hopper heating fans, material level alarm, signal transfer for conveyor start/stop control.
- 空調設備 & ビルディングオートメーション
Central air-conditioning control cabinets: エアダンパーアクチュエーター, differential pressure alarms, auxiliary fan control, anti-freeze protection signal interlock
Fresh air systems, 排気ファン, cooling tower auxiliary circuits
Zone lighting control; fire alarm signal transfer (only signal relay, NOT main fire protection circuit)
- ロジスティクス & Warehousing Equipment
Automated warehouses, sorting conveyor lines, peripheral control cabinets for AGVs
コンベヤ, sorting baffle cylinder control, logic expansion for photoelectric sensors
Indicator lights and alarm driver for warehouse access control
- 水処理 & 環境設備
投与システム, auxiliary control of small water pumps, high/low level signal transfer, aeration fan auxiliary circuits, signal switching for online water quality monitoring cabinets.
Environmental note: Anti-condensation treatment is mandatory inside humid cabinets to prevent contact oxidation and poor connectivity.
- エネルギー, EV Charging & PV Auxiliary Cabinets
- Auxiliary fault alarm and cooling fan control for small PV combiner boxes
- Signal transfer inside AC charging station control boards, fault indicator lights and auxiliary contactor coil driving
Forbidden: Do NOT switch high-voltage DC main circuits; only permitted for low-voltage control loops.
- Food Machinery & Central Kitchen Equipment (Key Target Segment)
Vegetable washing equipment, コンベア, small exhaust fans, warning lights
Smart Canteen & Central Kitchen Electrical Cabinets: Alarm signal for transparent kitchen monitoring, automatic door control, auxiliary ventilation control, solenoid valve drive for cleaning machines
✅ Advantage: DC24V is standard industrial voltage, unified with HMI, PLC and sensor power supply, supporting standardized cabinet wiring.
- Rail Support & Off-Highway Mobile Equipment
Onboard control cabinets for construction machinery, small tunnel ventilation control boxes, barrier and gate control cabinets; access control lock and traffic light drivers.
Vibration warning: Fit PYC-A1 locking clip to avoid relay disconnection.
- 研究室 & Testing Instruments
Aging test equipment, thermostats, small test fixtures; 電磁弁, low-power heating loads and alarm signal switching.
Compatible Load Classification
✅ Recommended Loads
- DC24V miniature solenoid valves, indicator lamps, ブザー
- 220VAC small fans, lighting loads, AC contactor coils
- Passive dry contact signal transmission
❌ Not Recommended / Strictly Forbidden Loads
- High-power motors and heating elements (inrush current far exceeds 5A rating)
- Loads with switching frequency >10 cycles/minute (accelerates contact wear)
- Hazardous explosive zones (no explosion-proof certification)
- Safety interlock and emergency stop circuits (use dedicated safety relays e.g. G9SX)
Selection Matching Advice
- Driven by PLC transistor outputs → Priority: MY2N-D2-GS (built-in diode, prevents back EMF damage to PLC)
- Driven by relay-output PLC → Standard MY2N-GS directly applicable
- If driving inductive loads such as contactors and solenoids without diode version, fit external surge absorption components.
取付寸法: OMRON MY2N-GS DC24V (5あ) 公定基準値
- Relay Body (without socket, 8-pin plug-in)
Maximum overall dimension (L × W × H): 28.0 × 21.5 × 36.0 mm
深さ (front-back): ≤28 mm
幅 (left-right): ≤21.5 mm
身長 (excluding pins): ≤36 mm
ピン: 8 cylindrical plug pins, standard 8-pin layout for MY2 series.
- Dimensions of Common DIN-mount Sockets
1) PYF08A-E (Standard widely used socket)
Overall dimension: 72 (D) ×22 (W) ×30 (H) mm
取り付け: 35mm standard DIN rail or screw fixing
Screw mounting holes: 2 個, Φ4.2×5 slotted hole, center distance 44 mm
Terminal screw specification: M3
2) PYFZ-08-E (Finger-safe safety socket)
Overall dimension: 72 (D) ×23 (W) ×31 (H) mm
3) PYF-08-PU (Push-in spring terminal socket)
Overall dimension: 72 ×23 ×31 mm
Reference total height: Relay fully inserted into socket ≈64 mm (for cabinet layout reservation)
- PCB Mount Alternative (Optional PY08-02 soldering socket)
For PCB soldering installation: PY08-02 PCB socket, fully pin-compatible with MY2N-GS.
- Practical Layout Parameters for Control Cabinet Design
- Minimum side-by-side mounting clearance: Can be installed adjacently; single unit occupied width 22 mm. Total width for N units ≈ 22 × N mm
- Vertical cooling clearance recommendation: ≥8mm top & 底; ≥10mm for densely packed arrangements
- Cabinet depth reservation: ≥75mm for socket + relay assembly (avoid interference with cabinet door)
- Vibration-prone applications: Install PYC-A1 locking clip to prevent dislodging.
- Important Remarks
- MY2N-GS shares identical outline dimensions and fully compatible sockets with legacy MY2N-J; direct field replacement supported.
- Narrow width of only 21.5mm, ideal for space-restricted control cabinets.
- Avoid mounting adjacent to contactors and high-power power supplies; elevated ambient temperature shortens contact service life.
コンタクタ,サーキットブレーカー,ソーラーインバーター,電気メーター,太陽電池