フエニックス・コンタクト PSR-SPP-24DC/ESD/4X1/30 セーフティリレー (Item No.: 2981813)
ブランド: フエニックス・コンタクト
- モデルコードの内訳
`PSR-SPP-24DC/ESD/4X1/30`
- PSR: Safety relay of PSRclassic series
- SPP: Push-in spring cage terminals (tool-free pluggable wiring)
- 24直流: Control coil rated voltage DC24V
- ESD: Electrical Switch-off Delay (dropout delay function)
- 4X1: 4 safety normally-open contacts (2 瞬間的な, 2 delayed)
- 30: Adjustable delay range: 0.1s ~ 30s
- Core Safety Ratings & 準拠基準
Forcibly guided mechanical contacts: IEC/EN 61810-3
Machinery safety: カテゴリー4 / PL e (ISO で 13849-1)
機能安全: シル 3 / SILCL3 (IEC 62061 / IEC 61508)
Applicable safety devices: Emergency stop pushbuttons, safety door interlock switches, safety light curtains
- 主要な電気仕様
3.1 Control Input (コイル)
定格電圧: DC24V, permissible operating range 0.85~1.1Un
Operating current: 75ミリアンペア
Response actuation time: 150MS
Reset recovery time: 330MS
3.2 出力接点 (4 N/O Normally Open)
Instantaneous contacts: 2 個, release time ≈20ms
Delayed contacts: 2 個, 調整可能な遅延: 0.1~30 seconds
接点材質: AgSnO₂
Continuous rated current: 6あ / 250AC/DCV
マックス. power for resistive loads: 1500バージニア州 (AC250V), 144W (DC24V)
Minimum switching capacity: 0.4W, minimum carry current 25mA
機械的寿命: 10 million switching cycles
3.3 配線 & 取り付け
端子: Pluggable push-in spring cage terminals (SPP)
取り付け: 標準35mm DINレール
保護クラス: IP20 (for cabinet internal installation only)
重さ: 約. 0.24kg
- 機能的な特徴
- 2-channel monitoring: Supports single/dual-channel safety circuit connection, compatible with dual-channel E-stop and safety door interlocks
- Two reset modes: 自動リセット / manually monitored reset (with feedback loop)
- Dropout delayed output: Delayed power cut-off for drives after equipment shutdown, ideal for scenarios requiring inertia coast-down of motors and slow stop of conveyors
- Tamper-proof design: Sealable delay adjustment knob to prevent unauthorized on-site modification of delay settings
- Built-in self-diagnosis: Integrated diagnostic LEDs to rapidly identify power supply faults, safety circuit open-circuits and reset failures
- 典型的なアプリケーションシナリオ
E-stop safety circuits for machine tools, injection molding machines and stamping equipment
Safety guard door monitoring for automated production lines
Signal evaluation for safety light curtains in robot workcells
Delayed power disconnection for conveyor and roller motors with inertia stop
- Cross-Series Alternative Comparison
| モデル | Item No. | 端子の種類 | 遅延範囲 | 接点構成 |
| PSR-SPP-24DC/ESD/4X1/30 | 2981813 | Push-in spring cage | 0.1~30代 | 2 instantaneous N/O + 2 delayed N/O |
| PSR-SCP-24DC/ESD/4X1/30 | 2981800 | ネジ端子 | 0.1~30代 | 2 instantaneous N/O + 2 delayed N/O |
- 調達 & Stock Information
Member price on official domestic store: 約. 人民元 3,475; standard minimum order quantity 1 piece per carton; industrial automation spare parts kept in regular stock.
Full Application Scenarios of PSR-SPP-24DC/ESD/4X1/30 (Item No.2981813)
Core advantages of this model: 2-channel safety monitoring + 2 instantaneous safety contacts + 2 dropout delay contacts (0.1~30代) + Cat.4/PL e/SIL3. It is specially designed for safety conditions where equipment carries large rotational inertia and cannot be fully powered off instantly. All scenarios support monitoring of three categories of safety components: E-stop buttons, safety door interlocks and safety light curtains.
- Basic Safety Signal Monitoring (Universal for All Automated Equipment)
1.1 Dual-channel Emergency Stop Circuit Monitoring
Dual-channel E-stop detection for machine tools, standalone production line units, robots and packaging machinery
Supports manually monitored reset / 自動リセット, with detection of short-circuits and open-circuit faults in E-stop wiring
Instantaneous contacts cut off main drives immediately; delayed contacts control slow stop of auxiliary loads including fans, conveyors and lubrication systems
1.2 Equipment Safety Guard Door Monitoring
Dual-channel monitoring of safety door interlocks for stamping machines, injection molders, マシニングセンター, robot enclosures and automated modules
Main spindle/servo power is instantly cut off when the door opens; 冷却, chip removal and conveyor systems keep running with delay until full inertia stop before disconnection
Detects cross-wire short-circuits in door switch wiring, fully compliant with machinery safety standards
1.3 Safety Light Curtain Signal Evaluation
Safety circuits for light curtains on stamping, bending, robotic loading/unloading and packaging lines
Main motor cuts off instantly upon curtain obstruction; delayed contacts operate discharge roller conveyors to clear residual materials
Built-in cross-circuit fault diagnosis, meeting the highest PL e safety rating requirements
- Core Featured Scenarios (Relying on ESD Dropout Delay Function, Exclusive Strength of This Model)
2.1 運ぶ & 物流機器 (Belt Conveyors, Roller Lines, Stacker Cranes)
ベルトコンベア, ローラー選別ライン, automated warehouse roller conveyors, packaging transport lines
Operating logic: After E-stop or door opening, main drive cuts off instantly; rollers remain running for an adjustable delay of 0.5~10s to clear materials on belts, avoiding material extrusion, machine jamming and belt tearing
Widely applied in food packaging, warehousing logistics and lithium battery assembly lines
2.2 Rotational Inertia Load Equipment (ファン, Centrifugal Machines, ミキサー, Extruder Screws)
Injection extruders, pelletizing screws, high-speed agitators, centrifugal dehydrators, high-power cooling fans, エアコンプレッサー
Operating logic: Main spindles carry massive inertia; instant power-off risks screw fracture and impeller damage. Main power is cut off instantly, while lubrication and cooling fans keep operating for 3~30s until rotational speed drops to zero before auxiliary circuits are disconnected
Standard configuration for plastic extrusion, chemical mixing, lithium coating and rubber pelletizing industries
2.3 Web Winding, Slitting & 印刷機器
Film slitters, paper printing machines, non-woven winders, lithium battery electrode slitters
After safety trigger, winding/unwinding servos cut off instantly; tension rollers keep running for 2~8s to prevent sudden web breakage and flying material hazards to operators
2.4 工作機械 & Metal Processing Equipment
CNC machining centers, CNC旋盤, punch presses, bending machines, グラインダー, レーザー切断機:
- Instant cut-off of spindle servos when safety door opens or E-stop is activated
- Delayed contacts continuously run cutting fluid pumps, cooling fans and chip conveyors; all power disconnected upon delay expiry
- Prevents damage to cutting tools and spindle bearings caused by rapid shutdown of hot spindles without cooling
2.5 Robot Workcells & Automated Assembly Units
6-axis robots, gantry manipulators, loading/unloading modules, welding stations:
Robot servos cut off instantly upon trigger from enclosure safety doors or area light curtains
Delayed control for slow stop of conveyors, fixture air blow dust removal and cooling fans
Compliant with safety specifications for auto parts and 3C electronics assembly
2.6 食べ物, 医薬品 & Packaging Equipment
Filling machines, シール機, horizontal form fill seal packaging machines, pharmaceutical sorting equipment:
Main transmission cuts off instantly when safety guards are opened
Discharge conveyors run delayed to clear food/medicine bottles, avoiding mold jamming and cross-contamination from accumulated materials
- Summary of Complete Sets of Applications by Industry
- Machine Tool Industry: CNC equipment, punch presses, bending machines, laser cutters, 射出成形機
- ロジスティクス & Warehousing Industry: Belt conveying, roller sorting, automated warehouse stacker cranes
- ゴム, プラスチック & 化学工業: Extrusion pelletizing, high-speed mixing, film slitting machines
- ロボット工学 & オートメーション: Welding, loading/unloading, enclosure safety protection for 3C assembly robots
- Lithium New Energy Industry: Safety monitoring for electrode slitting, coating and cell assembly lines
- 食べ物 & 製薬産業: Safety door + light curtain monitoring for filling, packaging and sorting equipment
- General Fan & Air Compressor Station: Safety circuits for maintenance access doors of high-power fans and water chillers
- Model Selection Guidance (Why Choose This Model Over Standard Non-Delayed Safety Relays)
- Standard safety relays cut off all contacts simultaneously; inertia loads easily suffer equipment damage and material jamming
- This model separates instantaneous safety circuits and delayed auxiliary circuits, balancing operator personal safety and equipment protection
- Push-in spring cage terminals (SPP) enable tool-free wiring and higher mass assembly efficiency in control cabinets
- Sealable delay adjustment knob prevents equipment faults caused by unauthorized on-site personnel shortening delay time
コンタクタ,サーキットブレーカー,ソーラーインバーター,電気メーター,太陽電池
















NH42-63-318x560.png)