Schneider A9L16634 Surge Protective Device - コンタクタ,サーキットブレーカー,ソーラーインバーター,電気メーター,太陽電池

微信: +86-13184948252 ワッツアップ: 0086-13811255435 電子メール: kent@bestcontactor.com

について 接触 |

Schneider A9L16634 Surge Protective Device - コンタクタ,サーキットブレーカー,ソーラーインバーター,電気メーター,太陽電池

電気/

Schneider A9L16634 Surge Protective Device

Schneider ACTI-9 IPRF1-12.5R-3P+N-A9L16634 Surge Protective Device (SPD) Model Code Definition Full Model Breakdown: ACTI-9-IPRF1-12.5R-3P+N-A9L16634 Code Segment Definition Detailed Description ACTI-9 Product Series Code for Schneider Electric ACTI-9 modular low-voltage distribution series IPRF1 Product Type Plug-in Type T1+T2 combined SPD with voltage-limiting structure 12.5R Core Parameter 12.5: Maximum impulse current Imax=12.5kA; R: Equipped with remote indication ...

  • 製品詳細

Schneider ACTI-9 IPRF1-12.5R-3P+N-A9L16634 サージ保護装置 (SPD)

  1. モデルコードの定義

Full Model Breakdown: ACTI-9-IPRF1-12.5R-3P+N-A9L16634

コードセグメント意味詳細な説明
ACTI-9製品シリーズCode for Schneider Electric ACTI-9 modular low-voltage distribution series
IPRF1製品タイプPlug-in Type T1+T2 combined SPD with voltage-limiting structure
12.5Rコアパラメータ12.5: Maximum impulse current Imax=12.5kA; R: Equipped with remote indication contact
3P+Nポール構成3-段階 + neutral pole protection, applicable to 230/400V three-phase four-wire power system
A9L16634注文コードUnique official Schneider part number for procurement and inventory management

Full Product Description: Acti9 iPRF1 12.5r 3P+N 350V Plug-in T1+T2 Surge Protector with Remote Indication

iPRF1: Pluggable design for easy maintenance & replacement without power cut-off

T1+T2: Comply with both Class I (10/350μs) およびクラス II (8/20μs) surge protection criteria

350V: Maximum continuous operating voltage Uc, matched for standard 230/400V AC power grid

Remote indication: Fault dry contact output for BMS/monitoring system integration

  1. 主要な技術仕様

基本的な電気パラメータ

アイテム価値ユニット備考
製品タイプT1+T2 combined SPDVoltage-limiting design against direct & induced lightning surge
ポール3P+NFull protection for three-phase four-wire including neutral line
Max Continuous Operating Voltage (UC)350VとSuitable for 50/60Hz 230/400V low voltage grid
Rated System Voltage (Un)230/400VとStandard LV distribution nominal voltage
Max Impulse Current Imax (10/350μs)12.5Class I rating for direct lightning diversion
公称放電電流入力 (8/20μs)50Class II rating for induced overvoltage suppression
電圧保護レベル (上)≤1.5kVClamp surge voltage to safeguard equipment insulation
応答時間≤25nsFast response to discharge transient surge energy
Short-circuit withstand capacity10Coordinate with upstream backup protection device

機械式 & 環境パラメータ

アイテム価値ユニット備考
取り付けDINレール取付Standard 35mm DIN rail complying with EN 50022
Overall Width72mmOccupies 4 modular pitches (18mm per module)
ハウジング材質ThermoplasticUL94 V0 flame retardant per IEC 60695-11-10
侵入保護IP20Finger-touch safe, for indoor cabinet installation only
動作温度-40 ~ +80Wide ambient temperature for harsh working condition
リモート信号ドライコンタクト (いいえ/いいえ)Contact status change upon SPD failure for remote monitoring
Terminationネジ端子Accept 1.5~35mm² copper conductor for reliable wiring

Ⅲ. Full IPRF1 Series Model List

モデルポールMax Impulse CurrentRemote Indication注文コード適用システム
iPRF1 12.5r 1P+N1P+N12.5のはいA9L16632Single-phase 230V system
iPRF1 12.5r 3P3P12.5のはいA9L16633三相3線式
iPRF1 12.5r 3P+N3P+N12.5のはいA9L16634Three-phase four-wire 230/400V system
iPRF1 12.5 1P+N1P+N12.5のいいえA9L612501Single-phase without remote monitoring
iPRF1 12.5 3P+N3P+N12.5のいいえA9L612601Three-phase four-wire without remote monitoring
  1. Cross & Legacy Replacement Options
  2. 同じシリーズの代替品
オリジナルモデル代替機種違いの説明Application Adjustment
iPRF1 12.5r 3P+N(A9L16634)iPRF1 12.5 3P+N(A9L612601)Remote indication removedSmall distribution without remote monitoring
iPRF1 12.5r 3P+N(A9L16634)iPRD1 12.5r 3P+N(A9L16482)Upgraded to iPRD1 series with enhanced reliabilityCommercial buildings requiring superior surge protection
iPRF1 12.5r 3P+N(A9L16634)iPRF1 Master 35r 3P+NImax upgraded to 35kALightning-prone zones & critical industrial facilities
  1. ブランド間の同等品
Schneider PartABB相当シーメンス相当品Phoenix Contact Equivalent
iPRF1 12.5r 3P+N(A9L16634)OVR T1+2 3N-40-3505SD7440-8VAL-MS 350/3+1-FM
保護クラスT1+T2T1+T2T1+T2
Max Impulse Current12.5の12.5の12.5の
≤1.5kV≤1.5kV≤1.5kV
Remote Contactはいはいはい
  1. Recommended Upgrade Models
旧モデルUpgrade ModelUpgrade Advantages適用範囲
iPRF1 12.5r 3P+N(A9L16634)iPRD1 25r 3P+N(A9L16483)Imax raised to 25kA for Class I/II building protectionLarge commercial complex & manufacturing plant
iPRF1 12.5r 3P+N(A9L16634)iPRF1 Master 35r 3P+NImax=35kA with superior surge withstandLightning intensive area, データセンター, 病院 & key infrastructures
  1. アプリケーション環境 & Project Cases

Recommended Applications ✅

商業ビル: Grade III/IV construction such as office towers, ショッピングモール, hotels against indirect lightning & switching overvoltage

産業プラント: Medium/small factory production line control cabinet, protection for PLC, inverter and precision automation equipment

Public Facilities: 学校, 病院, libraries to secure stable power supply for public equipment

小さい & Medium Data Room: Protect server & network devices from mains transient surge

住宅地: High-rise & villa community to safeguard home appliances & smart home control system

Non-Recommended Applications ❌

Grade I/II key construction (airport, railway hub, large-scale IDC): Requires iPRD1 series with ≥25kA Imax

Open-air exposed installation: IP20 not suitable for outdoor use without extra waterproof enclosure

Grid voltage exceeding 350V AC: Over Uc rating leads to premature SPD breakdown

Installation without qualified earthing: Required earth resistance ≤10Ω for effective surge dissipation

実用化事例

  1. Grade A Office Building: iPRF1 12.5r 3P+N(A9L16634) fitted in floor distribution panels for main power protection. Post-installation before thunderstorm season, IT equipment failure rate dropped by 85%, eliminating office shutdown & data loss caused by lightning strike. Remote contact links with building automation system for instant fault alert and 60% maintenance efficiency improvement.
  2. Auto Component Factory: SPD installed for robot & PLC control power supply. Original frequent unexpected production shutdown from grid fluctuation incurred monthly loss around CNY50,000; after SPD commissioning, downtime reduced by 90% with annual cost saving approx. CNY500,000. ≤25ns quick response prevents servo drive damage from voltage spike and improves machining precision.
  3. High-End Smart Residential Compound: SPD equipped at main distribution room and household panel to protect smart lighting, 安全 & home control devices. Remote signal connects property monitoring platform for 24/7 real-time status check, timely faulty module replacement, improving community power safety & resident satisfaction.
  4. 一般的な障害 & トラブルシューティング
故障の症状Root CauseRemedial Action予防措置
Remote alarm triggeredSPD module burnout or internal thermal disconnection1. Replace plug-in module after power offAnnual pre-thunderstorm routine inspection; replace SPD after 5 effective surge operations
2. Inspect upstream breaker tripping status
3. Test earth continuity
Module fails to clip onto DIN railImproper DIN rail or broken module latch1. Verify DIN rail complianceHandle module gently during installation, avoid brute force
2. Confirm correct insertion direction
3. Replace damaged SPD unit
端子過熱Undersized wire or loose screw1. Replace cable within 1.5~35mm² rangePeriodic thermal check on high-current wiring terminals
2. Retighten screw with 2.5Nm torque
Plug-in module stuckLock unreleased or over-clamped1. Press top release latchDo not over-press module during mounting
2. Wiggle slightly for extraction
Upstream MCCB tripsExcessive surge current or short-circuited SPD1. Check SPD integritySelect matched backup fuse/circuit breaker; regular earthing resistance test
2. Verify matching rating of upstream protection
3. Confirm earth resistance ≤10Ω

Ⅶ. 選定ガイドライン & クイックリファレンスルール

Quick Selection Mnemonic

12.5kA T1+T2 grade, 3P+N for three-phase grid,

350V rated with remote monitoring ready,

Plug-in structure easy to service, IP20 for indoor cabinet,

Ideal for commercial & factory, Grade III/IV lightning safeguard.

Quick Rules

  1. IPRF1 coding: suffix 12.5r =12.5kA + 遠隔連絡先; plain 12.5 = no remote indication
  2. 極の選択: 1P+N for single phase, 3P for 3P3W, 3P+N for standard 3P4W 400V grid
  3. Order code mapping: A9L16632(1P+N) / A9L16633(3P) / A9L16634(3P+N)
  4. Grade matching: iPRF1 12.5r for III/IV buildings; iPRD1 25r for I/II critical constructions
  5. インストール要件: Must be paired with upstream backup protection, earthing resistance ≤10Ω

前へ:

返信を残す

伝言を残す