LXM32: Lexium32 series servo
M: Multi-fieldbus version (CANopen supported, built-in encoder acquisition and positioning function)
D72: Peak output current 72A, continuous 24A
N4: 3-phase high-voltage model, 208~480VAC 3-phase power supply
コアの電気仕様
| アイテム | 仕様 |
| 電源 | 3-phase AC 208~480V, 50/60Hz |
| 定格電力 | 400Vクラス: 7kW; 230Vクラス: 5kW |
| 連続出力電流 | 24あ (8kHz carrier frequency) |
| ピーク出力電流 | 72あ, sustainable for 5s |
| Built-in EMC Filter | Standard integrated |
| Speed Loop Bandwidth | Up to 1600Hz, high dynamic response |
| キャリア周波数 | 8kHz |
| DC Bus Undervoltage Threshold | 350V (400Vクラス) |
コミュニケーション & I/O
- フィールドバス: CANopen (LXM32M model, different from pulse-type LXM32A)
- デジタル: Multiple 24VDC discrete inputs including 2 high-speed capture CAP ports; デジタル出力
- エンコーダインターフェース: Supports SinCos and EnDat, compatible with BSH/BMH servo motors
- インターフェース: RJ45 debug port, detachable color-coded terminals for convenient cabinet wiring and maintenance
マッチングモーター
Compatible with BSH / BMH 400V class サーボモーター of Lexium32 series. Typical match: 140-flange BSH high-torque motor, continuous torque up to 27.8N·m, peak 90.2N·m, common speed 3000rpm.
アプリケーションシナリオ
包装機械, machine tool feed axes, CNC cutting, 繊維機械, material handling conveying, multi-axis synchronization equipment; suitable for automated production lines requiring CANopen bus multi-axis linkage and high dynamic positioning.
インストール & 環境
Book-style cabinet mounting, vertical installation on control cabinet DIN rail
過電圧カテゴリ: クラスIII
Max leakage current: 30ミリアンペア
Recommended wire gauge for power terminals: 3mm², tightening torque 0.5N·m
故障 & 試運転メモ
- Common Alarms: Overcurrent OC, Overvoltage OV, Undervoltage UV, エンコーダの障害, Overheat OH
- ソフトウェアのコミッショニング: ソームーブ, supports online parameter configuration, oscilloscope sampling and automatic inertia tuning
- For high-power working conditions, it is recommended to install an external 1mH line reactor to reduce harmonics and incoming current surges
交換 & Selection Remarks
Pulse version of the same series: LXM32AD72N4 (CANopenなし, pulse-direction control)
代替アップグレード: シュナイダー Lexium28 series; comparable competitors: Siemens V90, Mitsubishi MR-J4
注記: LXM32 is a discontinued legacy series. Lexium28 is preferred for new projects; stock or second-hand units are available only for spare part projects.
HS Code Reference
85011099 (servo drive, re-verify customs classification before customs declaration)
LXM32MD72N4 SoMove Power-on Commissioning Parameter Template
該当する: Lexium32M 7kW CANopen bus servo, matched with BSH/BMH 400V motors; SoMove software, expert mode password 696969
Pre-operation: Complete hardware wiring including power cable, エンコーダ, 非常停止, ブレーキ, CAN bus and 24V control power supply; perform no-load jog test first, then auto-tune under load; save parameters to EEPROM after modification.
- 基本構成 (Simply Start Wizard Page)
| パラメータ名 | Parameter ID | Recommended Setting | 説明 |
| Control Source | DEVcmdInterf | フィールドバス | LXM32M CANopen positioning mode; temporarily change to Terminal for local jog |
| Motor Selection | Motor Selection | Select corresponding BSH/BMH model | Drive loads motor nameplate parameters automatically; must not select incorrectly |
| エンコーダの種類 | ENC1_type | シンコス / エンダット | Select according to motor encoder; EnDat absolute encoder requires battery module |
| キャリア周波数 | PWM_Freq | 8kHz | Default for LXM32MD72N4, not recommended to increase |
| Rotation Direction | InvertDirOfMove | オフ (デフォルト) | Set to ON if rotation direction reversed; power cycle required after change |
| Auto Enable on Power-up | IO_AutoEnable | 0 (Disabled) | Disabled during commissioning; can be set to 2 for mass production after safety assessment |
- Axis Limit Parameters (Axis Configuration → Limitations)
| パラメータ名 | Parameter ID | Recommended Setting | 説明 |
| Max Output Current | CTRL_I_max | モーター定格電流 | Limit maximum torque to protect machinery; cannot exceed 72A peak of drive |
| Max Motor Speed | M_n_max | モーター定格速度 | Typical 3000rpm for BSH/BMH, do not exceed nameplate |
| Positive Software Limit | POS_LIM_P | User unit | Inside mechanical hard limit to prevent overtravel |
| Negative Software Limit | POS_LIM_N | User unit | Same as positive limit |
| E-Stop Deceleration | QS_Dec | カスタム | Deceleration triggered by emergency stop, safety related |
- I/O & 安全パラメータ (Axis Configuration → IO)
| パラメータ名 | Parameter ID | Recommended Setting | 説明 |
| Positive Limit Contact | IOsigLIMP | NC Normally Closed | Default for safety standards; set to NO if using normally open sensors |
| Negative Limit Contact | IOsigLIMN | NC Normally Closed | 同上 |
| Brake Release Delay | BRK_AddT_Release | 100MS | Brake motor: wait for brake release before movement after servo enable |
| Brake Apply Delay | BRK_AddT_Apply | 50MS | Delay brake output after servo disable to prevent axis falling |
| フォルトリセット | IO_FaultReset | Assign DI terminal | External reset button |
- Position Scaling (Scaling, Core for Positioning Projects)
User units per revolution, 例: 10mm per revolution for lead screw, modify as required
| パラメータ名 | Parameter ID | Example Value | 説明 |
| —| —| —| —|
| Position Numerator | ScalePOSnum | 10 | Numerator of travel per revolution |
| Position Denominator | ScalePOSdenom | 1 | Denominator; 例: 10mm/rev → 10/1 |
| Velocity Scaling | ScaleVELnum / ScaleVELdenom | Follow position | Velocity unit: mm/s |
| Acceleration Scaling | ScaleACCnum / ScaleACCdenom | Follow position | Acceleration unit: mm/s² |
Raw encoder resolution: 16384count/rev for SinCos motors
- Servo Loop Gains (Tuning Page, No-load → On-load Auto-tune)
Prioritize SoMove automatic inertia identification + auto-tune, then fine tune
| パラメータ名 | Parameter ID | Initial Recommendation | Tuning Logic |
| —| —| —| —|
| Position Loop Gain | CTRL_Kp_pos | 3~8 | Higher for stiff mechanics; reduce if oscillation occurs |
| Speed Loop Gain | CTRL_Kp_vel | 80~150 | Base response, reduce for mechanical resonance |
| Speed Loop Integral Time | CTRL_Ti_vel | 8~20ms | Smaller value improves steady-state error, prone to oscillation |
| Velocity Feedforward | CTRL_Kff_vel | 0.6~0.9 | Reduce position following error |
| Acceleration Feedforward | CTRL_Kff_acc | 0~0.3 | For high-speed start-stop; large value causes impact |
| Low-pass Filter | CTRL_FiltVel | 500~1000Hz | Suppress resonance; lower filter frequency at resonance point |
- CANopen Fieldbus Parameters (Key for LXM32M)
| パラメータ名 | Parameter ID | Recommended Setting | 説明 |
| CAN Node ID | CAN_NodeID | 1~127 | No duplicate for multi-axis, consistent with PLC |
| CAN Baud Rate | CAN_Baud | 500kbps | Common setting; use 250kbps for long distance, terminal resistor ON at both bus ends |
| PDO Mapping | PDO Configuration | Standard positioning PDO | Target position, ステータスワード, actual position, fault code |
| Fieldbus Control Mode | Profile Mode | Profile Position | 位置決め制御; select Profile Velocity for speed axis |
| Profile Acc/Dec | PRO_ACC / PRO_DEC | Mechanical dependent | ユニット: user unit/s |
| Quick Stop Ramp | PRO_QSDec | Independent E-stop deceleration | Deceleration upon bus failure |
- Homing Parameters
| パラメータ名 | Parameter ID | 説明 |
| Homing Mode | HOM_mode | 0~35 optional; 一般: limit homing, index homing, direct origin setting for absolute encoder |
| Homing Velocity | HOM_Vel | 低速, 50~200 user unit/s |
| Homing Search Velocity | HOM_Vel_Search | Slightly higher than homing speed |
| Homing Offset | HOM_Offset | Mechanical origin offset |
- 監視 & Fault Log
Fault Buffer: Stores latest 16 alarms for troubleshooting of OV/OC/OH/ENC faults
オシロスコープ: Sample target position, actual position, following error, bus voltage, motor current for resonance and tuning analysis
Save: Device → User Functions → Save parameters to EEPROM; back up local project as .cxm file
Complete Power-on Commissioning Procedure (Matching Parameter Template)
- Connect PC to drive RJ45 debug port via SoMove, establish communication and read factory parameters
- Run Simply Start wizard, select motor model and confirm encoder type
- Configure limit, brake and I/O terminal definition
- Set position scaling and mechanical transmission ratio
- Set CANopen Node ID, baud rate and configure PDO
- 無負荷試験: 有効にする, jog, verify rotation direction, limit and brake logic
- On-load test: Run Auto-tune inertia identification to generate base gains
- Observe following error and oscillation via oscilloscope, fine-tune 3-loop gains and filter
- Homing test, point positioning test, acceleration/deceleration test
- Save parameters to EEPROM and export .cxm backup file
Commissioning Precautions
- Expert mode password 696969, enter expert mode to modify advanced parameters
- Auto-tune must be performed with actual load; parameters tuned under no-load easily oscillate under load
- Incorrect brake timing will directly cause axis falling; test brake function without load during first commissioning
- CANopen bus: Enable terminal resistor only at the first and last device on bus, disable for intermediate nodes
- For high-power LXM32MD72N4, check wiring of line reactor and braking resistor before first power-up
Optional Extended Parameters
制動抵抗器: BRK_R, BRK_P for external braking resistor resistance/power rating, bus overvoltage protection
アナログ入力: AI scaling for analog speed mode (not commonly used for CANopen projects)
Schneider Lexium32 (LXM32) Full Series Drive Model List
3 main branches: LXM32C (Basic Analog) / LXM32A (脈 + Modbus) / LXM32M (CANopen bus type, LXM32MD72N4 belongs to this branch)
接尾辞の説明:
M2: Single-phase 200~240VAC; N4: 3-phase 208~480VAC
Dxx: Number after D = peak current (あ), continuous current = 1/3 of peak current
状態: Full series discontinued, only available on spare parts market
- LXM32M (CANopen バスの種類, High Priority, includes LXM32MD72N4)
Single-phase 200~240V (Suffix M2)
| モデル | ピーク電流 | Continuous Current | 230V Rated Power |
| LXM32MD12M2 | 12あ | 4あ | 0.75kW |
| LXM32MD18M2 | 18あ | 6あ | 1.0kW |
| LXM32MD30M2 | 30あ | 10あ | 1.6kW |
| LXM32MD42M2 | 42あ | 14あ | 2.5kW |
| LXM32MD57M2 | 57あ | 19あ | 3.5kW |
3-phase 208~480V (Suffix N4, your series)
| モデル | ピーク電流 | Continuous Current | 400V Rated Power |
| LXM32MD12N4 | 12あ | 4あ | 0.9kW |
| LXM32MD18N4 | 18あ | 6あ | 1.8kW |
| LXM32MD30N4 | 30あ | 10あ | 3kW |
| LXM32MD42N4 | 42あ | 14あ | 4.5kW |
| LXM32MD57N4 | 57あ | 19あ | 5.5kW |
| LXM32MD72N4 | 72あ | 24あ | 7kW |
| LXM32MD85N4 | 85あ | 32あ | 9kW |
- LXM32A (Pulse/Direction + Modbus, CANopenなし, 同じ定格電力)
Single-phase M2
LXM32AD12M2, LXM32AD18M2, LXM32AD30M2, LXM32AD42M2, LXM32AD57M2
3-phase N4
LXM32AD12N4, LXM32AD18N4, LXM32AD30N4, LXM32AD42N4, LXM32AD57N4, LXM32AD72N4, LXM32AD85N4
- LXM32C (±10V analog basic model, speed/current control only, no positioning)
Single-phase M2
LXM32CD12M2, LXM32CD18M2, LXM32CD30M2, LXM32CD42M2, LXM32CD57M2
3-phase N4
LXM32CD12N4, LXM32CD18N4, LXM32CD30N4, LXM32CD42N4, LXM32CD57N4, LXM32CD72N4, LXM32CD85N4
- Matching Motor Series (BSH / BMH for Lexium32)
- BSH Motors: SinCos encoder, single-turn/multi-turn, IP50; flange sizes 55/70/100/140mm
- BMH Motors: EnDat absolute encoder, マルチターン, IP65; flange sizes 55/70/100/140/190mm
- 付属品一覧 (General for LXM32)
VW3M8101: 制動抵抗器
VW3M8D10: Encoder battery box (for EnDat multi-turn BMH motors)
VW3M8102: Line reactor
VW3M8200: Pre-made I/O terminal cable
VW3M8300: CANopen bus cable
VW3M8400: Motor power cable
VW3M8500: Encoder cable
Branch Comparison Overview
| モデルシリーズ | 制御インターフェース | Positioning Function | フィールドバス | 代表的な用途 |
| LXM32C | ±10V Analog | ❌ No positioning | Modbus | Pure speed control |
| LXM32A | Pulse+Direction | ✅ Point positioning | Modbus | Pulse PLC control |
| LXM32M | CANopen | ✅ Electronic gear / Point / Homing | CANopen | Multi-axis bus synchronization (LXM32MD72N4) |
選択のヒント:
- Same Dxx model: LXM32A and LXM32M have identical hardware power rating, differ only in firmware communication functions
- LXM32MD85N4 is the largest model in this series, 9kW
- New project replacement: Lexium28 series; only stock/second-hand units available for spare part projects.
コンタクタ,サーキットブレーカー,センサー,エンコーダ,PLC,コンバータ




















NH42-63-318x560.png)