Siemens 3RV6011-1AA15 Motor Protection Circuit-Breaker

正式な製品名: SIRIUS 3RV6 Series Domestic Motor Protection Circuit-Breaker (Motor Starter Protector) 3RV6 = Domestic version; 3RV2 = Imported equivalent replacement model: 3RV2011-1AA15 Model Decoding 3RV6 0 11-1 AA 15 3RV6: SIRIUS domestic motor protection circuit-breaker 0: Motor protection application 11: Frame size S00 (Width 45 mm) 1: Standard breaking capacity AA: Thermal overload setting ...

  • 製品詳細

正式な製品名: SIRIUS 3RV6 Series Domestic Motor Protection Circuit-Breaker (Motor Starter Protector)

3RV6 = Domestic version; 3RV2 = Imported equivalent replacement model: 3RV2011-1AA15

モデルのデコード

3RV6 0 11-1 AA 15

3RV6: SIRIUS domestic motor protection circuit-breaker

0: Motor protection application

11: Frame size S00 (Width 45 mm)

1: 標準遮断容量

AA: Thermal overload setting range 1.1-1.6 A

15: Built-in side auxiliary contacts 1NO+1NC (10 = without auxiliary contacts)

コア技術パラメータ

アイテム仕様
Thermal overload setting (あ)1.1 … 1.6 あ
Short‑circuit release N‑release21 あ (13×イン)
旅行クラスCLASS 10 (Normal motor starting)
主回路極3P
定格動作電圧AC‑690 V
Rated motor power @400V0.55 kW
Breaking capacity Icu@400V100 kA
終了ネジ端子
補助接点Integrated side‑mounted 1NO + 1NC
取り付け35 mm DINレール, またはネジ取り付け
全体の寸法W45 mm × H97 mm × D91 mm
保護等級IP20 (Front side)
動作温度‑20 … +60 ℃
HS customs code85362010

注文 & 交換品

  1. Imported OEM replacement: 3RV2011-1AA15 (identical functions and specifications, made in Germany)
  2. Version without auxiliary contacts: 3RV6011-1AA10
  3. Domestic 3RV6 and imported 3RV2 are fully interchangeable with identical mounting dimensions and wiring.

代表的な用途

Protection for small-size three-phase motors, 過負荷を与える, short-circuit and phase-failure protection. Widely used in control cabinets, ファン, pumps and small conveyors. Can be combined with contactors to form a motor starting unit.

互換性のあるアクセサリ (S00 frame size)

Side-mount auxiliary contacts: 3RV6901-1A

Side-mount auxiliary contacts: 3RV6901-1E (already integrated in this model)

不足電圧解除, シャントリリース, rotary operating handle and other expandable accessories.

Application Scenarios of シーメンス 3RV6011-1AA15

設定電流: 1.1-1.6あ, compatible with 0.55kW three-phase motor at 400V, Class 10 trip characteristic, built-in 1NO+1NC auxiliary contacts, S00 frame size (45 mm width). 過負荷を与える, short-circuit and phase-failure protection. Auxiliary contacts can be used for fault alarm and PLC signal feedback.

  1. Typical Motor Load Applications
  2. 小型ファン & cooling fan motors

Equipment cooling fans, cabinet ventilation fans, small HVAC fans. Continuous-run loads with moderate starting current. Offers phase-loss and overload protection; auxiliary contacts transmit fan fault signals.

  1. Miniature water pumps & 循環ポンプ

Small process circulation pumps, cooling water pumps, laboratory pumps. Rapid thermal tripping upon pump stalling to prevent motor burnout.

  1. Small conveying & drive equipment

Mini belt conveyors, small rollers, feeding mechanisms, compact conveyor drives. For standard direct-on-line (DOL) starting. Combined with 3RT7 contactors for complete motor starter assemblies.

  1. Machine-tool auxiliary drive motors

Machine-tool coolant pumps, 潤滑ポンプ, small feed auxiliary motors. コンパクトなキャビネットの設置; fault signals sent to PLC for equipment alarm.

  1. Small actuators for packaging & 印刷機械

0.55 kW three-phase drive motors for compact packaging machines, labellers and printing auxiliary equipment.

  1. Non-motor & System-level Applications
  2. Protection for small three-phase control transformers

Overload and short-circuit protection for low-inrush small-size transformers. Not suitable for transformers with high magnetizing inrush current.

注記: Use 3RV64 series for transformers with heavy inrush to avoid nuisance tripping.

  1. Compact motor feeder circuits inside control cabinets

High-density DIN-rail layout for multi-loop small-motor cabinets. Built-in 1NO+1NC eliminates extra auxiliary contact modules; outputs trip/closed status signals to PLC and HMI.

  1. Motor protection inside standalone machines

Integrated protection for built-in machine motors. Can also serve as an isolating switch for maintenance.

  1. Industry Sectors

産業オートメーション: Custom special-purpose machinery, test equipment

空調設備: Unit internal small fans and circulation pumps

工作機械: Coolant and lubrication pump motors

マテリアルハンドリング: Mini conveying mechanisms

研究室 & test equipment: Small three-phase drive assemblies

Compact control cabinets & OEM export equipment (Domestic 3RV6, cross-compatible with imported 3RV2011-1AA15)

  1. Recommended System Configurations
  2. Direct-on-line (DOL) starter: 3RV6011-1AA15 + 3RT7 contactor. Complete motor protection-starter unit. 3RA1931 bus module enables fast assembly without inter-wiring, キャビネットのスペースを節約する.
  3. Signal feedback configuration: NC contact for fault alarm; NO contact for closed-state feedback, connected to PLC digital input modules.
  4. Non-applicable Conditions
  5. Frequent heavy-duty starting and high-shock loads (incompatible with Class 10 trip characteristic)
  6. Motors with rated current outside 1.1-1.6 A range
  7. Transformers with high magnetizing inrush risk of unwanted tripping
  8. Outdoor environments with heavy dust or corrosive atmosphere (requires additional protective enclosure)

Rated Operational Voltage of 3RV6011-1AA15

Main-circuit rated operational voltage Ue: AC-690V (50-60 Hz)

詳細仕様

  1. Common operating voltages for motors

AC400V: Standard three-phase motor operating condition, matches 0.55 kW motor

AC230V / AC500V / AC690V are permissible. Breaking capacity remains 100 kA at 690 V.

  1. Rated voltage for auxiliary contacts (1NO+1NC)

AC-15: マックス. 230 V; DC-13: マックス. 60 V

⚠️ Auxiliary contacts shall not be connected to 690 V main circuits. Reserved for low-voltage signal circuits only.

  1. 定格インパルス耐電圧 Uimp: 6 kV

Standards reference: IEC 60947-2, IEC 60947-4-1. Domestic 3RV6 and imported 3RV2011-1AA15 share identical voltage ratings.

Overall Dimensions of Siemens 3RV6011-1AA15 (S00 Frame Size)

アイテム価値
Width W45 mm (DIN‑rail footprint width in cabinet)
Height H97 mm
Depth D91 mm (Body depth, protrusion depth after DIN‑rail mounting)
フレームサイズS00
正味重量約. 0.29 kg

Mounting Instructions

  1. Mounting options: 35 mm DIN-rail snap-on mounting, or base-plate screw fastening
  2. 取付方向: Any mounting position is allowed
  3. Clearance requirements:

Vertical clearance: ≥50 mm

Lateral clearance: ≥30 mm

Rear clearance: 0 mm (flush against DIN-rail)

Imported replacement 3RV2011-1AA15 has identical dimensions for direct drop-in replacement.