Wieland SNA-4053-K-A Safety Relay

SNA: Safety switch monitoring series (for monitoring emergency stop, safety gates, safety light curtains) 4053: Specification code K: Pluggable screw terminals A: Supply voltage AC/DC 24 V Suffix differentiation for the series: A = AC/DC 24 V; C = Push-in spring terminals; KM = Automatic reset; KE = Special version Core Specifications & Safety Ratings ...

  • 製品詳細

SNA: Safety switch monitoring series (for monitoring emergency stop, safety gates, safety light curtains)

4053: 仕様コード

K: Pluggable screw terminals

あ: Supply voltage AC/DC 24 V

Suffix differentiation for the series:

A = AC/DC 24 V; C = Push-in spring terminals; KM = Automatic reset; KE = Special version

  1. コア仕様 & Safety Ratings
  2. 安全認証

PL e / カテゴリ 4 (ISO で 13849-1)

シル CL3 (で 62061)

  1. 接点構成

3 safety normally open contacts (13-14 / 23-24 / 33-34)

1 normally closed signal contact (41-42)

  1. 電気データ

供給: 24 AC/DCV

Continuous rated current Ith: 8 あ

AC-15: 230 V / 5 あ; DC-13: 24 V / 5 あ

取り付け: から 35 ミリレール; 幅 22.5 mm

  1. Input Functions

Dual-channel safety circuit (S11/S12, S21/S22)

Supports cross-channel short-circuit monitoring

手動リセット (with reset monitoring)

に適しています: 非常停止ボタン, safety gate switches, magnetic safety switches, safety light curtains

  1. Typical Wiring Logic
  2. A1(+), A2(-): 24 V電源
  3. S11-S12, S21-S22: Dual-channel safety devices (normally closed signal)
  4. S33-S34: Reset terminals (connect external normally open reset button; shorted = automatic reset)
  5. 13-14 / 23-24 / 33-34: Safety outputs (for controlling main contactors)
  6. 41-42: Normally closed fault feedback signal
  7. Model Correction & 代替リファレンス

⚠️ The most frequently confused model on the market: SNA4043K-A (4043, easily mistaken for 4053)

⚠️ Important Verification Conclusion

SNA4053K-A is NOT an official standard model in Wieland catalogues, it is highly likely a transcription error:

  1. Most common miswriting: SNA4043K-A (部品番号. R1.188.1810.0)

自動リセット, no reset monitoring; dual-channel with short-circuit monitoring

  1. Alternative similar model: SNA4063K-A

手動リセット (with reset monitoring) — this is the core difference from SNA4043

Model rules:

SNA4043K-A: 自動リセット

SNA4063K-A: 手動リセット (reset button monitoring)

Both models share identical contact configuration, safety rating and dimensions; only reset logic differs.

Quick Selection Comparison Table

モデルメーカー品番.供給電圧リセットモード端子の種類
SNA4043K‑AR1.188.1810.0AC/DC 24 V自動リセットPluggable screw K
SNA4063K‑AR1.188.1870.0AC/DC 24 V手動リセット (with reset monitoring)Pluggable screw K

Recommended Actions

  1. Verify the printed model on the physical nameplate of the unit;
  2. Confirm site requirements: Reset monitoring required or not

Emergency stop circuits generally require manual reset (SNA4063K-A)

Safety light curtain applications may adopt automatic reset (SNA4043K-A)

Application Scenarios of Wieland SNA Series セーフティリレー (SNA4043 / SNA4063)

This series achieves PL e / カテゴリー4 / SIL3 with dual-channel monitoring, primarily deployed for safety circuits on machine tools and automated production lines. Content is divided into supported safety signal types, industry applications, and key selection differentiation.

  1. Supported Safety Input Signals (Hardware Utilization)
  2. 非常停止ボタン (dual normally closed contacts)

Most common application: Machine main emergency stop and zone emergency stop circuits.

Standard requirement: Emergency stop circuits prefer SNA4063K-A (manual reset with monitoring).

  1. Safety gate switches / Magnetic safety sensors

Interlock for protective doors, maintenance doors and perimeter fencing; power circuit cutout upon door opening.

  1. Safety light curtains

Hazard zone intrusion protection for presses, conveyor lines and robot stations.

Light curtain solutions commonly use SNA4043K-A (自動リセット).

  1. Two-hand control devices

For stamping and riveting equipment, preventing single-hand access to hazardous zones.

  1. Safety mats, safety bumpers

Perimeter intrusion detection around robot cells, automatic doors and lifting platforms.

  1. Major Industry & Equipment Applications

(1) 工作機械産業

CNC旋盤, machining centres, グラインダー, パンチングマシン, bending machines

応用: Protective door interlock, 非常停止回路, safety light curtain protection

(2) Automated Production & 包装設備

包装機, palletizers, コンベアライン, sorting equipment, ラベラー

Robot workstations, gantry robot safety fence interlock

(3) ゴム & Plastics Industry

Injection moulding machines, 押出機, blow moulding equipment: Safety gates, 非常停止, safety light curtains

(4) ロジスティクス & Warehousing Equipment

Automated warehouses, lifts, shuttles, 行を並べ替える

Lifting platforms, dock leveller safety interlocks

(5) 新エネルギー & リチウム電池装置

Cell assembly machines, 電解液充填機, sealing equipment, test tooling

Wieland products are widely adopted on export machinery to meet EU CE Machinery Directive requirements

(6) 木工 & 印刷機械

Panel saws, 切断機, printing presses, die-cutting machine safety protection

(7) General Custom Automation

Custom test fixtures and assembly machines; deployed as core safety logic unit to cut off main contactors and servo power circuits.

  1. Critical Application Selection Comparison
モデルリセットモード代表的な用途
SNA4043K‑A自動リセットSafety light curtains, safety bumpers; system enables restart automatically after obstacle removal
SNA4063K‑A手動リセット (with reset monitoring)非常停止ボタン, safety gate switches. Manual reset operation is mandatory before machine restart (required by machinery safety standards)

⚠️ SNA-4053-K-A is not an official Wieland standard model. It is almost certainly a nameplate transcription error; physical unit will be one of the two above variants.

  1. 制限事項 & 不適切な用途
  2. Cannot directly drive high-power loads; safety contacts are intended to control contactor coils, not motors directly
  3. Not suitable for solenoid valves or high-frequency switching loads
  4. Cannot satisfy safety requirements higher than PL e / カテゴリー4 (this series already reaches Cat.4 maximum rating)

Selection Guidelines for Wieland SNA / SNO Safety Relays

Based on the SNA4043 / SNA4063 platform covered above; structured criteria ready for engineering proposals and procurement checks.

ステップ 1: Confirm Required Safety Rating (Mandatory Priority)

ISO準拠 13849-1 / で 62061

  1. PL & カテゴリ

PL e / カテゴリー4: Highest rating. For high-risk stations including robots, stamping, injection moulding, machine tools and lithium battery equipment (supported by all mainstream SNA variants)

PL d / カテゴリ3: Low-risk general automation and conveyor lines

  1. SILレベル

シル 3 corresponds to PL e; preferred for machinery exported to EU

✅ Selection Rule: Do NOT downgrade safety rating for high-risk equipment.

ステップ 2: Determine Safety Input Channel Configuration (Dual Channel Is Standard)

Channel Modes

Dual-channel monitoring with cross short-circuit detection: Industry standard, fitted across all SNA variants. Compatible with dual normally closed safety devices (非常停止, safety gates, light curtains)

Single channel: Only permitted for low-risk scenarios; available on selected SNO variants. NOT allowed for high-risk machinery.

Compatible Sensor Types

Emergency stop switches, mechanical safety gates: Dual normally closed (ノースカロライナ州)

Magnetic safety switches, safety light curtains: デュアルNC / OSSD signals

⚠️ Two types of safety light curtains:

① OSSD solid-state output → Requires relay model supporting OSSD input

② Light curtain with relay converted contact output → Compatible with standard SNA4043 / SNA4063

ステップ 3: リセットモード (Most Common Source of Wrong Selection!)

Reset Typeモデル例応用Compliance Note
自動リセットSNA4043K‑ASafety light curtains, safety bumpers, 安全マット; system ready after obstacle clearedFORBIDDEN for emergency stop and safety gate circuits
手動リセット (with reset line monitoring)SNA4063K‑A非常停止ボタン, machine protective safety gates; manual reset push required before restartMandatory recommendation per machinery safety standards; preferred for most complete machinery

Key Distinction:

Monitored reset detects open or short circuits on reset wiring and triggers safety lockout for superior safety. Simple unmonitored manual reset should be avoided on new projects.

ステップ 4: 供給電圧

Main Wieland options:

Suffix A = AC/DC 24 V (Automation standard, selected in 90% of projects)

Less common: 110 VAC, 230 VAC — only for legacy retrofits

例: SNA4063K-A → A = AC/DC 24 V電源

ステップ 5: 端子の種類 (Identified by Suffix K / C)

K = Pluggable screw terminals

利点: Vibration resistant, ideal for permanent cabinet installation and on-site maintenance (the unit in your photo uses K terminals)

C = Push-in spring terminals

利点: Fast wiring without screwdrivers; use cautiously under heavy vibration

例: SNA4063K-A

ステップ 6: Output Contact Configuration

Main Safety Outputs (For Power Circuit Cutoff)

SNA4043 / SNA4063: 3 通常は開いている安全接点

目的: Wired in series with main contactor coils for redundant shutdown

Auxiliary Signal Contacts (PLC Feedback)

1 built-in normally closed fault contact

Opens upon safety activation or relay fault; used for alarm indicators and PLC signalling

選択メモ: If multiple feedback signals are required, add auxiliary relays. Safety contacts should not be expanded externally.

Contact Load Ratings

AC-15: 230 V / 5 あ

DC-13: 24 V / 5 あ

👉 Never drive motors directly; only control contactor coils!

ステップ 7: 取り付け & 物理仕様

  1. 取り付け: Standard DIN 35 ミリレール
  2. 幅: SNA40xx series 22.5 mm, compact design saving cabinet space
  3. 環境評価: IP20 (キャビネット設置のみ; not for outdoor direct deployment)

ステップ 8: Differentiate SNA vs SNO Series (Frequent Confusion)

SNA Series: Dual-channel safety monitoring, up to PL e Cat.4; for emergency stop, safety gates, light curtains (your target series)

SNO Series: Predominantly single channel, lower safety rating generally PL d and below; low-cost basic solutions

Common Selection Pitfalls Checklist

  1. ❌ Misapplication: Using automatic reset SNA4043 for emergency stop circuits — violates machinery safety standards, fails third-party audit & CE認証
  2. ❌ Transcription error SNA-4053-K-A: No official model; physical unit is either SNA4043 or SNA4063
  3. ❌ Direct drive of solenoid valves or high-power loads with safety contacts → contact burnout and loss of safety function
  4. ❌ Mixing K screw terminals and C spring terminals, leading to mismatch on delivery
  5. ❌ Ignoring reset monitoring requirements → machine fails acceptance testing

Rapid Selection Workflow (For Field Engineers)

  1. Identify safety device: 非常停止 / safety gate → select SNA4063xx-A (monitored manual reset); Light curtain / safety bumper → SNA4043xx-A (自動リセット)
  2. Confirm supply voltage: Default AC/DC24V suffix A
  3. Select terminal type: Permanent cabinet installation → K screw terminal; high volume assembly for fast wiring → C spring terminal
  4. Verify safety rating: High-risk equipment requires PL e / カテゴリー4 / SIL3
  5. Confirm number of safety contacts sufficient for contactor control

Complete Official Model List of Wieland SNA40xx Safety Relays

Series Profile: safeRELAY SNA40xx dual-channel safety monitoring, PL e / カテゴリー4 / SIL3, DINレール取付;

⚠️ Important Notice: SNA-4053-K-A is NOT an official Wieland model, it is a transcription error. Official core variants are limited to 4043 / 4044 / 4063 / 4064;

Industry standard: Suffix A = AC/DC24 V (automation default). Specify A suffix for new orders.

  1. モデルの命名規則

`SNA 40XX [ターミナル][リセット]-[Voltage Suffix]`

  1. SNA: Dual-channel safety monitoring base unit
  2. 40XX:

4043: 3 safety NO contacts, 自動リセット (no reset monitoring)

4044: 4 safety NO contacts, 自動リセット (no reset monitoring)

4063: 3 safety NO contacts, 手動リセット (with reset circuit monitoring)

4064: 4 safety NO contacts, 手動リセット (with reset circuit monitoring)

Last digit 3 = 3 safety NO contacts; Last digit 4 = 4 safety NO contacts

  1. Terminal Code

K: Pluggable screw terminals (most widely used in projects)

C: Pluggable Push-in spring terminals

  1. Extended Reset Suffix (KM/KE)

KM: Simple manual reset without monitoring; rarely specified for new projects

  1. Voltage Suffix

あ: AC/DC 24 V (automation standard)

サフィックスなし: Fixed screw terminals (legacy models, 段階的に廃止された)

  1. Mainstream Models for Domestic Projects (24 AC/DCV)

SNA4043 Series | 自動リセット, 3 Safety NO Contacts

フルモデルWieland Part No.端子の種類接点構成リセットモード代表的な用途
SNA4043K‑AR1.188.1810.0Pluggable screw K3 Safety NO + 1 NC Fault Contact自動リセット (no reset monitoring)Safety light curtains, safety bumpers, 安全マット
SNA4043C‑AR1.188.1940.0Push‑in spring C3 Safety NO + 1 NC Fault Contact自動リセット (no reset monitoring)High volume cabinet fast wiring

SNA4044 Series | 自動リセット, 4 Safety NO Contacts

フルモデルWieland Part No.端子の種類接点構成リセットモード代表的な用途
SNA4044K‑AR1.188.1860.0Pluggable screw K4 Safety NO + 1 NC Fault Contact自動リセット (no reset monitoring)Applications requiring multiple safety cutout circuits, light curtain systems
SNA4044C‑AR1.188.1960.0Push‑in spring C4 Safety NO + 1 NC Fault Contact自動リセット (no reset monitoring)Synchronous cutout of multiple contactors

SNA4063 Series | 手動リセット (Monitored), 3 Safety NO Contacts【Preferred for Complete Machinery】

フルモデルWieland Part No.端子の種類接点構成リセットモード代表的な用途
SNA4063K‑AR1.188.1440.0Pluggable screw K3 Safety NO + 1 NC Fault ContactManual reset ✅ with reset monitoring非常停止ボタン, machine safety gates, CE certified machinery (Most Popular)
SNA4063C‑AR1.188.1950.0Push‑in spring C3 Safety NO + 1 NC Fault ContactManual reset ✅ with reset monitoringExport custom automation, fast cabinet wiring

SNA4064 Series | 手動リセット (Monitored), 4 Safety NO Contacts

フルモデルWieland Part No.端子の種類接点構成リセットモード代表的な用途
SNA4064K‑AR1.188.1880.0Pluggable screw K4 Safety NO + 1 NC Fault ContactManual reset ✅ with reset monitoringMulti‑group power circuit cutout, large machine tools
SNA4064C‑AR1.188.1970.0Push‑in spring C4 Safety NO + 1 NC Fault ContactManual reset ✅ with reset monitoringSystems requiring synchronous shutdown of multiple contactors
  1. Legacy Non-Standard Voltage Models (Only For Equipment Replacement, Not Recommended For New Projects)

Fixed non-pluggable screw terminals (no suffix A)

SNA4043K: AC42~48 V / AC115 V / AC230 V

SNA4063K: AC230 V

注記: All new domestic machinery shall adopt AC/DC24 V models with suffix -A

  1. General Specifications Applicable to All Variants
  2. 安全性評価: PL e / カテゴリー4, シル 3 (EN ISO13849-1, EN62061)
  3. Contact Ratings: AC-15 230 V/5 A; DC-13 24 V/5 A
  4. 取り付け: から 35 ミリレール; 幅 22.5 mm; IP20 (Cabinet installation only)
  5. 特徴: Dual-channel cross short-circuit monitoring, EDM external device monitoring support, 3 status LED indicators
  6. 配線: Supports single-channel / dual-channel connection modes
  7. Quick Selection Summary Table
Model GroupリセットモードCompatible Safety DevicesCompliance Restriction
SNA4043 / SNA4044自動リセットSafety light curtains, safety bumpers❌ NOT permitted for emergency stop and machine safety gate circuits
SNA4063 / SNA4064手動リセット (Monitored)Emergency stop switches, safety gate switches✅ Compliant with EN60204 machinery safety standards, accepted for CE audits
  1. Procurement Reminders
  2. If customer submits model `SNA-4053-K-A` → Confirm transcription error immediately. Check physical nameplate; the actual unit is almost certainly SNA4063K-A.
  3. Always include complete model + manufacturer part number in BOM to avoid delivery mismatch between K screw terminals and C spring terminals.
  4. Do not interchange automatic reset SNA4043 and monitored manual reset SNA4063; incorrect selection will lead to failed safety acceptance.
  5. Contact count selection: 3 contactors or less → SNA4063; ≥4 contactors requiring synchronous shutdown → select SNA4064.