ABB E1N16-R1600-PR121-LSI

ABB SACE Emax E1 Series Fixed-type Air Circuit Breaker, rated current 1600A, equipped with PR121/P microprocessor-based electronic trip unit and three-stage LSI protection function. Model Code Definition Segment Code Description E1N E1N Series identifier for ABB SACE Emax E1 fixed ACB; E1=series code, N=fixed mounting, B=draw-out mounting 16 16 Incoming frame current rating: 1600프레임 ...

  • 제품 세부정보

ABB SACE Emax E1 Series Fixed-type 기중 차단기, rated current 1600A, equipped with PR121/P microprocessor-based electronic trip unit and three-stage LSI protection function.

  1. 모델 코드 정의
분절암호설명
E1NE1NSeries identifier for ABB SACE Emax E1 fixed ACB; E1=series code, N=fixed mounting, B=draw-out mounting
1616Incoming frame current rating: 1600프레임 크기 (8=800A, 10=1000A, 12=1250A, 16=1600A)
R1600R1600Rated current code: In=1600A (R800=800A, R1000=1000A, R1250=1250A, R1600=1600A)
PR121PR121Trip unit model: ABB PR121/P basic microprocessor trip unit supporting LI/LSI protection
LSILSIProtection type for three-stage protection: L=Long time delay (초과 적재), S=Short time delay (단락), I=Instantaneous (단락)

 

  1. Core Technical Specification Table
범주Detailed Parameters표준 & 인증
기본등급• 제품 시리즈: SACE Emax E1IEC 60947-2
• Device Type: 기중 차단기 (ACB)GB 14048.2
• 장착: 고정형CCC, CE, UL, CSA Approved
• 폴란드: Optional 3P/4P
• Frame Current (아이유): 1600에이
• Rated Current (~ 안에): 1600에이
• Trip Unit: PR121/P-LSI (3-stage protection)
• 정격 작동 전압 (우에): 690뷔와, 50/60헤르츠
• 정격절연전압 (우이): 1000뷔와
• Rated Impulse Withstand Voltage (음): 12kV
• Ultimate Short-circuit Breaking Capacity (중환자실): 50kA@415V AC, 42kA@690V AC
• Rated Service Short-circuit Breaking Capacity (IC): 50kA@415V AC (100% 중환자실의)
기계 & 전기적 성능• Mechanical Endurance: 10,000 운영IEC 60947-1
• Electrical Endurance: 500 operations at rated short-circuit breaking capacity
• Control Supply Voltage: 220V AC/DC (기준), optional 110V/400V
• Operation: Motor spring charging + motor closing/tripping, manual emergency operation available
• Auxiliary Contacts: 표준 2NO+2NC, expandable up to 10NO+10NC
• Wiring Capacity: Copper busbar 10×100mm², cable up to 300mm²
• Tightening Torque for Bolts: 50N·m
Physical Dimension• 장착: 수직 장착 (기준), optional horizontal mountingIEC 60529
• Overall Size(폭×높이×깊이): 296×302×418mm (3P fixed version)
• 무게: Approx.45kg (3피)
• Ingress Protection: IP30 for bare breaker, IP40 with enclosure
주변 조건• Operating Temp: -5°C ~ +40°C (40°C 이상에서는 정격 감소 필요)IEC 60068-1
• Storage Temp: -25°C ~ +70°C
• Relative Humidity: 95% @25°C, 비응축
• 오염도: 수업 3
• Altitude: 2000m 이하 (derating required over 2000m elevation)
Eco & Sustainability• Compliant with EU RoHS DirectiveABB Green Product Certification
• PFOS/PFOA free construction
• Recyclable material ratio ≥90%
• Low power consumption: Control circuit ≤15W
  1. Full Part Number List (E1N Series, 1600A Frame Size)
부품 번호.설명정격전류보호 유형
1SDA055782R1E1N1600 R800 PR121/P-LI800에이리 (2-단계: Long Delay + 동시에 일어나는)
1SDA055783R1E1N1600 R1000 PR121/P-LI1000에이
1SDA055784R1E1N1600 R1600 PR121/P-LI1600에이
1SDA055785R1E1N1600 R800 PR121/P-LSI800에이LSI (3-단계: Long+Short+Instantaneous)
1SDA055786R1E1N1600 R1600 PR121/P-LSI1600에이LSI
1SDA055787R1E1N1600 R800 PR123/P-LSIG800에이LSIG (4-단계 + Earth Fault protection)
1SDA055788R1E1N1600 R1600 PR123/P-LSIG1600에이LSIG

Full Series Coverage: Frame ratings 800A/1000A/1250A/1600A; 결정된(N)/인출형(비) 설치; LI/LSI/LSIG protection; 3피 & 4P configurations available.

  1. 브랜드 간 동등 & 교체 옵션

4.1 In-brand ABB Replacement

원래 모델대체 모델사양 차이
E1N16-R1600-PR121-LSIE1B16-R1600-PR121-LSIDraw-out type for convenient maintenance, replaceable without power shutdown
E1N16-R1600-PR121-LSIE1N16-R1600-PR123-LSIGUpgraded to 4-stage LSIG with additional earth-fault(G) 보호
E1N16-R1600-PR121-LSIE2N16-R1600-PR121-LSIE2 higher-grade series, breaking capacity raised to 65kA@415V AC

4.2 Cross-Brand Comparison Chart

씨줄슈나이더 일렉트릭지멘스친트
E1N16-R1600-PR121-LSIMT16H1600 3P 5.03WL1116-3BB36-4AA0NA1-1600-1600M/3P
차단 용량:50kA@415V차단 용량:50kA@415V차단 용량:50kA@415V차단 용량:50kA@415V
LSI three-stage protectionLSI three-stage protectionLSI three-stage protectionLSI three-stage protection
PR121/P trip unit미세학 5.0 trip unit3WL electronic trip unitNA1 electronic trip unit
  1. 적용범위 & 실제 사례

5.1 Recommended Application Fields

Industry SectorTypical Usage선택의 장점
산업용 배전Main incoming feeder of factory, 변압기 이차 보호, large MCC50kA 높은 차단 용량, precise LSI selective coordination for complicated industrial environment
상업용 건물Main distribution panel for shopping mall, hotel & office towerSpace-saving fixed mounting, motorized operation for remote control & 쉬운 유지 보수
데이터 센터UPS output & main power distribution for server roomLow power loss design, 높은 신뢰성, capable of ATS interlock for redundant power supply
중요 인프라Main protection for airport, 지하철, hospital vital loadsWide working voltage to resist grid fluctuation, fast fault isolation to minimize blackout range
에너지신산업LV side of step-up transformer in PV plant, combiner cabinet for energy storageExcellent harmonic withstand, customizable inverse-time protection curve matching new-energy characteristics

 

5.2 Non-recommended Applications

DC 회로: Select dedicated Emax DC series (e.g.E1N-DC)

Installation above 2000m altitude without current derating

Frequently switching loads: Adopt contactor + thermal overload relay combination instead

Severe environment with Pollution Degree 4: Extra enclosure protection required

5.3 일반적인 적용 사례

Case1: Main Distribution for Automobile Manufacturing Plant

애플리케이션: Secondary-side main protection for 10kV/0.4kV factory transformer (1600에이)

구성: E1N16-R1600-PR121-LSI 3P fixed type with PR121/P-LSI trip unit

성능: Realizes long-delay overload, short-delay & 순간 단락 보호; forms selective coordination with downstream MCCB to limit fault outage area and improve power supply reliability.

Case2: UPS Output Distribution in Large-scale Data Center

애플리케이션: Main protection for 2000kVA UPS outgoing terminal

구성: E1N16-R1600-PR121-LSI 4P fixed type plus communication module for remote monitoring

이점: Low power consumption reduces UPS loading; optimized protection curve avoids unintended UPS tripping under short-circuit; communication function enables early fault alert & remote diagnosis.

  1. Common Troubleshooting Guide
결함 현상Root CausesRemedial Actions
Failed motor closing1.Abnormal control supply1.Measure input control voltage
2.Uncompleted spring charging2.Await automatic charging or manual charge
3.인터록이 해제되지 않음3.Check rack position & cabinet door interlock
4.Faulty closing coil4.Test coil resistance and replace defective component
Abnormal trip unit display1.Failed internal power module1.Check auxiliary supply for trip unit
2.Broken CT wiring2.Tighten or repair open-circuited CT connections
3.Trip unit program error3.Power cycle trip unit; contact ABB service if fault persists
Unintentional frequent tripping1.Overload or downstream short-circuit1.Measure load current and clear short fault
2.Incorrect protection setting parameters2.Re-calibrate protection setting for selective coordination
3.지나치게 높은 주변 온도3.Improve cabinet ventilation & ambient cooling
4.트립 장치 오작동4.Verify trip performance or replace trip unit
Stiff manual operation1.Mechanism jamming by foreign matter1.Clean internal mechanism and reassemble
2.Fatigued operation springs2.Inspect charging/closing spring condition
3.Insufficient lubrication3.Apply specified lubricant per service manual

 

  1. 항공 운송 규정 준수 & 인증

7.1 Air Transport Regulation Compliance

Product Property: No built-in lithium battery/supercapacitor, classified as general electrical equipment

Shipping Classification: Non-dangerous goods compliant with IATA DGR regulations

포장: Standard wooden case with inner cushion padding against mechanical damage

Transport Note: Precision device; avoid severe shock & vibration during transit

7.2 Main Certifications List

인증인증서 번호.Valid Market
CCC2.02101E+15Mainland China
CE0123/CEEU & EEA
ULE250000북아메리카
CSA250000캐나다
RoHS 규제Comply with Directive 2011/65/EUGlobal environmental restriction of hazardous substances
  1. 빠른 선택 규칙 & Summary Tips

빠른 선택 규칙

  1. Frame Current Identification: 손가락 “16” =1600A frame; 8=800A,10=1000A,12=1250A
  2. Rated Current Lookup: Rxxx = nominal In; R800=800A, R1000=1000A, R1250=1250A, R1600=1600A
  3. Protection Code Definition: LI=2-stage, LSI=3-stage, LSIG=4-stage with earth fault
  4. 장착 코드: N=Fixed type, B=Draw-out type
  5. 차단용량 등급: E1=50kA@415V; E2=65kA@415V