Allen-Bradley 100-C85A00 AC 접촉기 - 접촉기,회로 차단기,감지기,인코더,PLC,변환기

위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

 Allen-Bradley 100-C85A00 AC 접촉기 - 접촉기,회로 차단기,감지기,인코더,PLC,변환기

접촉기/

Allen-Bradley 100-C85A00 AC 접촉기

중요사항: The standard coil of 100-C85A00 is AC240V 60Hz, NOT 220V 50Hz. Preferred replacement for domestic 220V 50Hz supply: 100-C85KF00 (AC230V 50/60Hz universal for 220V applications) Basic Specifications Series: 100-C IEC AC Contactor (Allen-Bradley, 로크웰 오토메이션) 주요 연락처: 3-극 아니오, AC-3 rated current 85A Auxiliary Contacts: 0아니요+0NC (no built-in auxiliary contacts); external auxiliary contact ...

  • 제품 세부정보

중요사항: The standard coil of 100-C85A00 is AC240V 60Hz, NOT 220V 50Hz.

Preferred replacement for domestic 220V 50Hz supply: 100-C85KF00 (AC230V 50/60Hz universal for 220V applications)

기본사양

시리즈: 100-C IEC AC Contactor (Allen-Bradley, 로크웰 오토메이션)

주요 연락처: 3-극 아니오, AC-3 rated current 85A

보조 연락처: 0아니요+0NC (no built-in auxiliary contacts); external auxiliary contact modules available

터미널: 나사 터미널; coil terminals on Line Side

설치: 35mm DIN 레일

표준: IEC/EN 60947-4-1, UL, CCC 인증

수명주기: 100-C85A00 discontinued; 100-C85KF00 active

전력 등급 (AC-3 모터 부하)

230V 3상: 30HP

460V 3상: 60HP

575V 3상: 60HP

모델 분석

100-C85 A 00

100-기음: MCS-C IEC 접촉기 시리즈

85: AC-3 rated current 85A

에이: Coil code → AC240V 60Hz

00: 보조 접점 구성: 0아니요+0NC

In-stock same-frame models for 220/230V

100-C85KF00: AC230V 50/60Hz coil (first choice for domestic 220V, no built-in aux contacts)

보조 접점 내장: 100-C85KF10 (1아니요), 100-C85KF01 (1NC)

교체 지침

  1. Never directly replace 100-C85A00 (240V 60Hz) on domestic 220V 50Hz supply; insufficient pull-in force will cause chattering and coil burnout.
  2. 선호하는 교체: 100-C85KF00
  3. 국내 상당: CJX2-8011; Schneider LC1D80

호환 가능한 액세서리

보조 접점 블록: 100-에프 (1NO/1NC)

서지 억제기: 100-에이 (RC type), 100-AR (varistor type)

Matching overload relay: 193-E 시리즈

Replacement Cross Reference for 100-C85KF00 (AC-3 85A, AC230V 코일, 0아니요+0NC)

메모: Allen-Bradley offers 85A frame; Siemens and Schneider do not have an exact 85A model. The standard equivalent is the 80A frame with sufficient margin; select 95A for full current coverage.

코일: AC220/230V 50/60Hz for domestic use; all models come with built-in auxiliary contacts (no native 0-aux version; block off unused contacts if required).

상표모델 (AC230V 코일)AC‑3 Current @400V비고
알렌 브래들리100‑C85KF0085에이0NO+0NC built‑in; add external 100‑F auxiliary blocks
지멘스 (Domestic SIRIUS 3RT6)3RT6037‑1AN0080에이S3 frame, 나사 터미널; 1NO+1NC built‑in; block off aux contacts if 0‑aux is required
지멘스 (Import 3RT1)3RT1037‑1AN0080에이Imported version, same electrical parameters as 3RT6037‑1AN00
지멘스 (Upgraded 95A for heavy duty)3RT6044‑1AN0095에이Recommended for heavy loads and frequent starts
Schneider TeSys Deca (LC1D)LC1D80M7C80에이M7 = AC220V 50/60Hz; 1NO+1NC built‑in
Schneider EasyPact D3N EconomyLC1N80M5N80에이M5 = AC220V 50Hz, 비용 효율적
슈나이더 (Upgraded 95A)LC1D95M7C95에이Preferred for AC‑4 and jogging duty

모델 설명 & Auxiliary Contact Notes

  1. Siemens 3RT6037-1AN00

3RT6: 국내 시리우스; 037: 80에이; 1AN00: AC220V 50/60Hz

한정: This frame always comes with 1NO+1NC built-in; no native zero-aux version. Cover unused contacts if the drawing requires 0NO+0NC.

  1. Schneider LC1D80M7C

LC1D: 테시스 데카; 80: AC-3 80A; M7: AC220V 50/60Hz

Same limitation: 1NO+1NC built-in; no zero-aux original model.

  1. If you strictly require zero built-in auxiliary contacts (all aux contacts external only):

Siemens and Schneider do not produce native zero-aux models in this current range due to design differences. This will not affect wiring or PLC logic; only drawing notation needs revision.

Motor Power Equivalence (400V 3상)

AB 100-C85KF00: 45kW

3RT6037-1AN00 / LC1D80M7C: 40kW

3RT6044-1AN00 / LC1D95M7C: 50kW

Matching Overload Relays

Allen-Bradley: 193-E 시리즈

지멘스: 3RU6137 (for 3RT6037)

슈나이더: LRD43 (for LC1D80)

교체 위험 경고

  1. Mounting dimensions and DIN rail positions are similar, but terminal layout and overall height differ. Verify outline drawings before retrofitting existing panels.
  2. Coil pull-in voltage range and power consumption differ slightly; do not reuse old coil parameters directly.
  3. For AC-4 jogging and frequent forward/reverse operation, select the 95A frame instead of 80A.
  4. Never directly replace 100-C85A00 (240V 60Hz); always use the KF coil variant first.

Additional Domestic Alternatives

CJX2-8011 (AC220V 코일, 80에이, 1NO+1NC built-in)

Allen-Bradley Bulletin 100-C (IEC AC Contactor) Full Catalog List

시리즈: 100-C = standard 3-pole contactors (AC-3); 104-C = reversing contactors (정방향/역방향); 100S-C / 104S-C = positively guided safety contactors

모델 규칙: `100-Cxx△yy`

더블 엑스: AC-3 정격 전류

△: 코일 코드 (열쇠: KF=AC230V 50/60Hz, first choice for domestic 220V supply)

yy: 내장형 보조 접점: 00=0NO+0NC; 10=1NO; 01= 1NC; 11=1NO+1NC

  1. Current Frame Base Models (swap coil code only)
기본 모델AC‑3 Current @400V400V Motor Power
100‑C09□□9에이4kW
100‑C12□□12에이5.5kW
100‑C16□□16에이7.5kW
100‑C23□□23에이11kW
100‑C30□□30에이15kW
100‑C37□□37에이18.5kW
100‑C43□□43에이22kW
100‑C50□□50에이25kW
100‑C60□□60에이30kW
100‑C72□□72에이37kW
100‑C85□□85에이45kW (당신의 모델)
100‑C97□□97에이55kW
  1. Coil Code Reference (Most Common Domestic Types)
암호코일 전압설명
KJAC24V 50/60Hz24VAC control
KFAC230V 50/60Hz✅ Preferred for domestic 220V (100‑C85KF00)
KVAC110V 50/60Hz110VAC control
디DC24V (표준 DC 코일)24VDC control
DDDC110V110VDC control
에이AC240V 60Hz (유산, 예를 들어. 100‑C85A00, not recommended for domestic 50Hz supply)North American 60Hz specification

Auxiliary suffix: 00 /10 /01 /11

예: 100-C85KF00 = 85A, AC230V, zero built-in aux contacts; 100-C85KF10 = 85A, 230다섯, 1NO built-in

  1. Full Active Catalog Numbers (3-폴, 나사 터미널, line-side coil)

09에이

100-C09KJ00 / 100-C09KJ10 / 100-C09KJ01 / 100-C09KJ11

100-C09KF00 / 100-C09KF10 / 100-C09KF01 / 100-C09KF11

100-C09KV00 / 100-C09D00

12에이

100-C12KJ00 / 100-C12KF00 / 100-C12KV00 / 100-C12D00

16에이

100-C16KJ00 / 100-C16KF00 / 100-C16KV00 / 100-C16D00

23에이

100-C23KJ00 / 100-C23KF00 / 100-C23KV00 / 100-C23D00

30에이

100-C30KJ00 / 100-C30KF00 / 100-C30KV00 / 100-C30D00

37에이

100-C37KJ00 / 100-C37KF00 / 100-C37KV00 / 100-C37D00

43에이

100-C43KJ00 / 100-C43KF00 / 100-C43KV00 / 100-C43D00

50에이

100-C50KJ00 / 100-C50KF00 / 100-C50KV00 / 100-C50D00

60에이

100-C60KJ00 / 100-C60KF00 / 100-C60KV00 / 100-C60D00

72에이

100-C72KJ00 / 100-C72KF00 / 100-C72KV00 / 100-C72D00

85에이

100-C85KJ00

100-C85KF00 (domestic 220V standard model)

100-C85KF10, 100-C85KF01, 100-C85KF11

100-C85KV00

100-C85D00

100-C85A00 (legacy 240V 60Hz; not recommended for direct domestic replacement)

97에이

100-C97KJ00 / 100-C97KF00 / 100-C97KV00 / 100-C97D00

  1. 104-C Reversing (정방향/역방향) Complete Catalog Numbers (integrated mechanical interlock)

체재: 104-CxxKF22 (22 = 1NO+1NC built-in aux contacts)

104-C09KF22, 104-C12KF22, 104-C16KF22, 104-C23KF22

104-C30KF22, 104-C37KF22, 104-C43KF22, 104-C50KF22

104-C60KF22, 104-C72KF22, 104-C85KF22, 104-C97KF22

  1. Compatible Spare Parts (Universal for all 100-C frames)

보조 접점 블록: 100-FA11 (1아니요+1NC), 100-FA20 (2아니요), 100-FA02 (2NC)

서지 억제: 100-에이 (RC 스너버), 100-AR (배리스터)

Matching overload relay: 193-E 시리즈 (direct plug-on fit with 100-C)

기계적 인터록: 100-M05 for C09~C43; 100-M13 for C50~C97

  1. 선택 참고 사항
  2. 100-C is an IEC frame, not NEMA; NEMA contactors are the 100-D series with higher current ratings.
  3. Screw terminals are standard; spring-clamp terminals carry the CR suffix (100-CR…).
  4. 수명주기: 100-C85A00 (A coil) 단종; KF coil variants remain active with CCC certification for mainland China.
  5. 4-pole contactors: 100-Cxx□400 (4NO main contacts for resistive loads only).
  6. Overload Relay Quick Matching (193-이자형)

C09~C16: 193-EECB

C23~C43: 193-EEED

C50~C72: 193-EEEE

C85 / C97: 193-EEEF

일반적인 결함 & Troubleshooting for Allen-Bradley 100-C /100S-C /104-C Contactors

Applicable to your 100-C series. 중요한: No separate replacement parts for main contacts, armature cores or springs for the 100-C frame. Only coils can be ordered individually; replace the entire unit if mechanical or contact damage occurs.

Safety Precaution: Isolate power, apply lockout/tagout, and verify zero voltage before maintenance.

  1. 코일에 전원이 공급됨, contactor fails to pull in completely

징후: No movement or sound when control voltage is applied

근본 원인

  1. Missing coil supply, broken wiring, open emergency stop / 안전 인터록 / interlocking contacts
  2. 오픈 코일 권선 (resistance reading infinite on multimeter)
  3. Wrong coil specification (typical case: 100-C85A00 (AC240V 60Hz) connected to 220V 50Hz supply → insufficient pull-in force or no pull-in)
  4. Mechanical binding: iron core clogged with metal dust, dirt, deformed housing, jammed guide rail or fatigued return spring
  5. Control voltage lower than 85% 정격 가치의

솔루션

  1. Measure voltage directly at coil terminals (not just power supply terminals); check E-stop, 안전문, PLC outputs and 104-C mechanical interlocks
  2. Verify coil catalog code (KF=AC230V, KJ=AC24V, KV=AC110V, D=DC24V)
  3. Replace coil if open circuit; replace the whole contactor if core jamming or housing deformation occurs
  4. Clean dust and oil from pole faces; check for skewed mounting
  5. 수다쟁이, loud buzzing, repeated pull-in and drop-out (contact chatter)

징후: Rapid “click-click” vibration with continuous hum; contacts cycle rapidly and burn quickly

근본 원인

  1. Low control voltage, excessive voltage drop on long cables, insufficient power supply capacity (가장 빈번한 원인)
  2. Dirty, rusted or oily core pole faces with poor contact; broken short-circuit ring on AC coils (100-C AC models)
  3. Wrong coil rating (60Hz North American coil used on 50Hz mains)
  4. Poor contact on auxiliary contacts causing loose holding/latching circuit
  5. Loose DIN rail mounting leading to cabinet resonance

솔루션

  1. Measure coil voltage under load; maintain voltage within 85%~110% of rated value
  2. Clean pole faces when de-energized; replace the entire contactor if the short-circuit ring is broken (no spare ring available)
  3. Replace legacy A-code (240V 60Hz) coils with KF-code (AC230V 50/60Hz universal) 코일
  4. Tighten DIN rail and mounting screws
  5. Repeated coil burnout and excessive overheating

징후: Discolored coil with burnt odor and melted insulation; repeated coil failure within short periods

근본 원인

  1. Sustained overvoltage (>110% 등급) or sustained under-voltage with incomplete core closure (large magnetizing current due to air gap)
  2. Operating frequency exceeding the rated mechanical operation rate of the 100-C series
  3. 높은 주변 온도, poor cabinet ventilation, and overcrowded contactors with no heat gap
  4. No surge suppression for frequent switching of inductive loads (모터, 솔레노이드 밸브)
  5. Misapplication: AC coil used on DC supply

솔루션

  1. Eliminate mechanical binding to ensure full core closure; stabilize supply voltage
  2. Upgrade to 100-E series or select one frame larger for high-frequency jogging duty
  3. Maintain spacing between contactors; add cabinet cooling fans; install surge suppressors 100-A (RC) / 100-AR (배리스터)
  4. 메모: Standard DC coils run hot with continuous energization (no energy-saving circuit)
  5. 주요 접점 침식, 변색, 위상 손실, 과열, weak motor torque

징후: Hot terminal lugs, unbalanced three-phase current, motor hunting, frequent overload relay tripping

근본 원인

  1. Continuous overload or AC-4 jogging / frequent forward-reverse operation with undersized contactor (AC-3 and AC-4 ratings differ significantly)
  2. Loose terminal screws creating high contact resistance and thermal runaway
  3. Arc erosion and end-of-life contact wear
  4. Mismatched upstream circuit breaker/fuse protection leading to short-circuit damage to contacts

솔루션

  1. Retorque main terminal screws per Rockwell torque specifications
  2. Measure three-phase current and re-evaluate load rating; select one frame larger for AC-4 duty (upgrade C85 to C97)
  3. Replace the entire contactor if contacts are heavily arced; do not file or repair contacts for long-term service
  4. Verify SCCR short-circuit coordination with upstream protection devices
  5. Failure to drop out after de-energization; 접촉 용접 (HAZARD CONDITION)

징후: Main contacts remain closed even after coil power is removed; motor cannot stop

근본 원인

  1. Severe short-circuit or locked-rotor current melting contact silver plating (most dangerous failure mode)
  2. Progressive welding caused by continuous contact chatter and repeated arcing
  3. Fatigued return springs or oil-sticky pole faces preventing core release
  4. Jammed mechanical interlock on 104-C reversing contactors

솔루션

  1. ⚠️ Never pry welded contacts open for continued service; replace the whole unit immediately
  2. Investigate phase short circuits, motor stall conditions, and implement triple protection (program interlock + 전기적 인터록 + 기계적 인터록) for forward/reverse circuits
  3. Upsize contactor rating, add current limiting, adjust star-delta timing, and fit surge suppressors if welding recurs
  4. Inspect 100-Mxx mechanical interlock parts for deformation or jamming on 104-C units
  5. Auxiliary contact failures (external 100-FA blocks)

징후: Unstable PLC feedback, intermittent latching, lost control signals

근본 원인

  1. Poorly latched auxiliary contact modules with loose snap-on clips
  2. Auxiliary contacts rated only for low-power control circuits; cannot directly drive solenoid loads
  3. Arc burn and mechanical fatigue
  4. Failed positively guided mirror contacts on 100S-C safety models (safety circuit risk)

솔루션

  1. Reinstall 100-FA modules and confirm full clip engagement
  2. Use auxiliary contacts only for dry control signals; do not switch high-power solenoids directly
  3. Use 100S-C positively guided safety contactors for safety feedback circuits; never use standard 100-C models
  4. Special Faults for 104-C Reversing (정방향/역방향) 접촉기

Jammed or broken mechanical interlock: 100-Mxx interlock parts can be ordered separately for replacement

Simultaneous pull-in of forward and reverse contactors: Implement three-level interlock (program logic + 전기적 인터록 + 기계적 인터록) and avoid short transition timing

  1. 환경 & Aging Failures

습기, corrosive gas and dust: Core rusting, insulation degradation and leakage current

High-altitude or high-temperature enclosures: Derate current rating and select one frame larger

Long-term storage: Dust buildup on pole faces; manually test mechanical operation before power-up

Step-by-Step On-site Troubleshooting Procedure

  1. De-energize power → Visual inspection: burnt marks, 변색, 느슨한 단자, deformed housing
  2. Measure coil resistance and cross-check coil voltage catalog code
  3. Manually depress the contactor to check for smooth mechanical movement and binding
  4. Apply power under supervised conditions; measure coil voltage under load to rule out undervoltage
  5. Test continuity across main three-phase contacts to detect welding or open phases
  6. Check auxiliary contacts, interlocks, emergency stops and safety loops

키 선택 & 애플리케이션 노트 (for your 100-C85KF00)

Never replace KF coils with legacy A coils (240V 60Hz); chatter and coil burnout will occur on 50Hz mains

No separate main contact kits for 100-C; replace the whole unit once contacts are damaged; only coils are available as spare parts

Upsize one frame for AC-4 jogging and frequent forward/reverse cycling

이전:

답장을 남겨주세요

메시지를 남겨주세요