Allen-Bradley 2711-T5A2L1 Touchscreen

Rockwell Automation no longer supplies new units. Items available on the market are second-hand, refurbished or spare stock. It is a classic legacy monochrome HMI of the PanelView Standard 550 시리즈. ✅ Model Breakdown 2711-T5A2L1 2711: PanelView Standard series T: Touchscreen only (no membrane keypad) 5: 5.5-inch display A: Monochrome LCD (검은색 & 하얀색) 2: ...

  • 제품 세부정보

로크웰 오토메이션 no longer supplies new units. Items available on the market are second-hand, refurbished or spare stock. It is a classic legacy monochrome HMI of the PanelView Standard 550 시리즈.

✅ Model Breakdown

2711-T5A2L1

2711: PanelView Standard series

티: Touchscreen only (no membrane keypad)

5: 5.5-inch display

에이: Monochrome LCD (검은색 & 하얀색)

2: DH-485 communication port, no print port

L1: 24V DC power supply version

📋 핵심 기술 사양

목명세서
표시하다5.5-inch monochrome LCD, resistive touchscreen
전원공급장치18~30VDC, rated 24VDC; Max 12W, 0.5A@24V
의사소통DH‑485 (for connection with legacy AB SLC500, MicroLogix PLCs)
메모리Non-volatile memory 240KB / RAM 170KB
설치Panel cutout mounting, front panel IP65
프로그래밍 소프트웨어PanelBuilder32 (legacy software, 32-bit OS only)
Firmware VersionsCommon A series, firmware 3.30/4.41 등.
작동 온도0~55℃
Unavailable PortsNo print port, 이더넷 없음

📌 Typical Applications

Legacy production line retrofits, 포장 기계, 자재 취급, 수처리, and older SLC500/MicroLogix projects. DH485 bus only, no EtherNet/IP support.

⚠️ Common Failures & 예비 부품

  1. Backlight degradation: Most typical fault. Spare part 2711-NL1 (CCFL backlight tube; LED backlight modification is also feasible)
  2. Damaged touch panel: PV550 touch membrane can be replaced separately
  3. 프로그램 손실: On-board coin cell battery preserves screen programs; program loss occurs once battery fails
  4. 통신 실패: DH485 bus termination resistor, wiring polarity, RSLinx driver issues

🔁 Replacement Options for Engineering Retrofit

Original project cannot be migrated directly, screen reconfiguration is mandatory

  1. Preferred direct replacement: 2711R-T4T / 2711R-T7T (패널뷰 800). Supports RS485 and connects to legacy PLCs;
  2. Modern alternative: 패널뷰 플러스 7 / 패널뷰 5000 series with Ethernet port;
  3. 3rd-party domestic HMI: Weintek / Kunlun MT, connecting legacy AB controllers via DH485/Modbus with lower cost.

📎 Supporting Documentation

수동: 2711-UM014 (PanelView Standard Terminal User Manual)

데이터시트: 2711-TD007

HS Code Reference

85287110 (Industrial touchscreen, HMI, applicable for customs declaration)

2711-T5A2L1 (패널뷰 550) Old-to-New HMI Program Migration Assessment Checklist

해당되는: Migration from legacy AB PanelView Standard 550 to PanelView 800 / 패널뷰 플러스 / 3rd-party domestic HMI

요점: PanelBuilder32 project cannot be imported into new HMI software; full reconfiguration required. This checklist is used for pre-migration risk assessment and workload estimation.

  1. 하드웨어 & Communication Assessment
Assessment Item검사 내용Risk Notes
Original Controller ModelSLC500 / 마이크로로직스 1000/1100/1200/1500?Legacy PLC only supports DH485; verify whether new HMI has native DH485, otherwise protocol converter required
통신 프로토콜원래의: DH485New HMI options: DH485 / DF1 / 모드버스 RTU (PLC side must support)
Address MappingOriginal PV550 tags: N, 비, 티, 기음, 아르 자형, F and other PLC registers⚠️ Register addresses must be checked line by line, do not copy by experience; distinguish bits / 단어 / floats
통신 배선Existing DH485 bus, termination resistors, wiring polarityNew HMI communication interface differs, evaluate rewiring and additional converter workload
전원공급장치24VDCMost old & new units compatible; verify terminal definition and fuse rating
Panel Cutout Dimension2711-T5A2L1 cutout: 216 × 152mmNew HMI dimension differs; evaluate: 직접 교체 / adapter plate / cabinet cutout modification
설치환경온도, 먼지, 진동Verify new HMI environmental rating and IP protection match site conditions
  1. Original HMI Project Inventory (Export from PanelBuilder32)
Assessment Item검사 내용비고
Total Screen CountMain screen, manual mode, 경보, parameter, trendCount screens to estimate configuration man-hours
Screen Element ListButtons, 지표, numeric displays, input boxes, 선택기 스위치Distinguish bit read/write, word read/write, multi-state indicators
Alarm InformationAlarm text, trigger bit, acknowledge bit, alarm log⚠️ PV550 uses simple bit-triggered alarms; new HMI alarm storage capacity varies
Recipe FunctionRecipe used or not?PV550 recipes stored locally in HMI; re-plan recipe storage location (HMI / PLC) for new HMI
Trend CurvesReal-time / historical trend, sampling cycleLegacy PV550 only supports simple real-time trend without large-capacity history logging; evaluate history storage for new HMI
Security AccessPassword, user level, screen access permission오래된 & new permission models differ; recreate user accounts
Macro / Script LogicPanelBuilder32 built-in macrosHigh risk: Macros cannot be migrated. All logic must be rewritten using new software scripts / 기능
Screen Switch LogicScreen jump buttons, conditional jumpReplicate conditional jump logic line by line
Print FunctionThis 2711-T5A2L1 model has no print port, skip this itemEvaluate printing if other models in the series are used
Hardcopy / ScreenshotScreen capture function required?Configure on demand for new HMI

III. Tag / Variable Mapping Assessment (Core Workload Item)

  1. Export full variable list of original project (print variable table in PB32)
  2. 분류 & statistics:

Boolean (Bit: 달리다, 잘못, Auto/Manual, Alarms)

Integer (Word: Setpoints, 카운터)

Float (온도, 압력)

  1. Verify PLC data file types: N files, B files, T/C preset values, registers
  2. Mark special variables:

Arrays

Indirect addressing (High risk: many new HMIs do not support legacy AB indirect addressing syntax)

Read-only / Read-write attributes

Risk note: DH485 address notation differs between HMI software packages, prone to address offset errors.

  1. Function Equivalence Assessment (Item-by-item comparison, mark missing functions)
Original PV550 Function비고
Bit buttons, momentary / latching buttonsDistinguish momentary pushbuttons (most common error source)
Multi-state indicators (3-상태 / multi-state)
Numeric input, limit validationPV550 local limit check; new HMI can validate on HMI side or PLC side
Screen jump, conditional jumpTest conditional jump logic
Alarm trigger, alarm acknowledgeAlarm text encoding (중국인 / 영어; legacy units mostly English)
Recipe read/writeVerify recipe quantity and data length
Real-time trendSampling cycle, channel quantity
User password permissionPassword hierarchy, lock function
Macro logicDecompose macro logic and implement via PLC logic or new HMI scripts
  1. PLC Side Change Assessment

Whether PLC program modification is required to adapt new HMI communication

Whether spare PLC register space is available for new HMI functions (recipes, history logging)

Whether PLC firmware supports new protocols (예를 들어. DF1)

Downtime window assessment for PLC program download

  1. Test Plan Assessment
  2. Offline simulation: Simulate screens and variables in HMI software, verify addresses
  3. Bench test: New HMI + identical site PLC bench commissioning (recommended to reduce on-site downtime)
  4. Step-by-step on-site power-up test:

Communication connectivity test

All screen switching

Full button operation & indicator feedback

Parameter write / read verification

Alarm trigger & acknowledge test

Recipe read/write test

  1. Long-term aging test (선택 과목)
  2. Rollback plan: Keep old HMI, mark wiring for fast fallback in case of failure

Ⅶ. 선적 서류 비치 & Delivery Assessment

Backup of new HMI project source file

Variable cross-reference table (old tags ↔ new HMI variables)

Screen function specification document

Updated wiring diagram (HMI terminals, communication bus)

Updated site operation manual

Spare parts list (new HMI spare parts, 통신 모듈)

Ⅷ. Risk Summary & Man-hour Estimation

Fill directly into assessment form

  1. High-risk items: Macro logic, indirect addressing, address misalignment
  2. Medium-risk items: Alarm logic, recipes, communication parameter mismatch
  3. Low-risk items: Screen layout, static text

Man-hour reference:

10 basic screens without complex macros/recipes: estimated 1~2 working days for configuration + 테스트; projects with heavy macros, recipes, indirect addressing require double the man-hours.

  1. Downtime Plan Assessment

Planned downtime window duration

Wiring modification time

Commissioning time

Emergency plan & rollback scheme

Rockwell Allen-Bradley PanelView HMI Full Series List

Grouped by generation, marked【Active / Discontinued】, with supporting software and key features. Optimized for your 2711-T5A2L1 legacy screen retrofit selection

Catalog rule: 2711 = legacy classic; 2711R=PanelView800; 2711P=PanelView Plus; 2715=PanelView5000; 2800=OptixPanel

  1. Legacy Classic Series (모두 단종됨, second-hand/spare market; your 2711-T5A2L1 belongs here)

1.1 PanelView Standard (2711 시리즈, monochrome / early color, PanelBuilder32 software)

패널뷰 300: 2711-T3A / 2711-K3A, 3-inch monochrome, DH485

패널뷰 550: 2711-T5A2L1 / 2711-K5A2L1, 5.5-inch monochrome (당신의 모델)

패널뷰 600: 2711-T6C / 2711-K6C, 6-inch color

패널뷰 900: 2711-T9C / 2711-K9C, 9-inch color

패널뷰 1000: 2711-T10C / 2711-K10C, 10-inch color

의사소통: DH485, DF1; 이더넷 없음; Programming software: PanelBuilder32 (32-bit Windows only)

Typical faults: CCFL backlight aging, on-board coin cell causing program loss

1.2 PanelView Component (2711기음, 단종)

2711C-C200, miniature modular HMI, paired with Micro800 compact PLC, simple screens

1.3 Early Generation PanelView Plus (First-gen 2711P, 단종)

Original PV Plus, WinCE, FactoryTalk View ME, 600/700/1000/1250/1500

  1. Previous Generation: 패널뷰 플러스 6 (2711피, EOL Discontinued, existing installed base)

소프트웨어: FactoryTalk View 머신 에디션 (FTView ME), WinCE6.0

PV Plus6 400: 2711P-T4C / K4C, 4-인치

PV Plus6 600: 2711P-T6C / K6C, 6.5-인치

PV Plus6 700: 2711P-T7C / K7C, 7-인치

PV Plus6 1000: 2711P-T10C / K10C, 10.4-인치

PV Plus6 1250: 2711P-T12C / K12C, 12.1-인치

PV Plus6 1500: 2711P-T15C / K15C, 15-인치

Suffix explanation: T=Touch; K=Membrane Keypad; C=Color; D=DC 전력; A=AC power

  1. Active Classic: 패널뷰 플러스 7 (2711피, Active for Sale), 기준 / Performance versions

소프트웨어: FactoryTalk View ME; Performance version runs Win10 IoT Core, supports video, VNC, DLR ring

표준 버전: 4”,7”,10”,12”,15”

예: 2711P-T4W21D8S, 2711P-T7C21D8S, 2711P-T10C21D8S, 2711P-T12W21D8S, 2711P-T15C21D8S

Performance high-performance version: 7~19” wide screen, stainless steel enclosure, conformal coated ArmorView machine-mount type

예: 2711P-T7C22D9P, 2711P-T10W22D9P, 2711P-T15C22D9P, 2711P-T19C22D9P

  1. Economy Small Size: 패널뷰 800 (2711아르 자형, Active for Sale), Preferred replacement for legacy DH485 projects

소프트웨어: FactoryTalk View 800 (lightweight standalone software); 이더넷 + RS485/DF1 native support, perfect for SLC500/MicroLogix, recommended replacement for your 2711-T5A2L1

2711R-T4T: 4.3-inch touch

2711R-T7T: 7-inch touch

2711R-T10T: 10.4-inch touch

Touch-only models, 비용 효율적, popular for legacy line retrofit

  1. New High-End Platform PanelView 5000 (2715 시리즈, Active for Sale), for Logix5000: ControlLogix/CompactLogix

소프트웨어: Studio5000 View Designer (integrated into Studio5000, FTView ME incompatible), native EtherNet/IP for large automation projects

  1. 패널뷰 5310 (2713피, 기초적인): 4”,7”,10”,12”,15”

예: 2713P-T10CD

  1. 패널뷰 5510 (2715피, high-performance):7/10/12/15/19”, 만지다 / keypad hybrid

예: 2715P-T7CD, 2715P-T10CD, 2715P-T15CD

⚠️Critical reminder: PV5000 project is fully incompatible with PanelView Plus projects, screen migration impossible

  1. 신세대: OptixPanel (2800 시리즈, Rockwell new HMI, Active for Sale)

Successor to PanelView 800 선, Compact and Standard models, FactoryTalk Optix software, native IoT & edge visualization

OptixPanel Compact (2800기음): 2800기음-070AS-1S (7-인치)

OptixPanel Standard (2800에스):7/10/12/15-인치

Designed for new projects, weak native DH485 serial support, not recommended for direct replacement of legacy 2711 스크린

  1. Mobile Handheld HMI: MobileView (2711티)

Cabled pendant handheld operator terminal for machine-side operation, 2711T series, partial models available.

  1. Industrial Panel PC (Not pure touchscreen, industrial all-in-one PC, ASEM series)

6300피, 6300M series industrial panel PCs, 윈도우 OS, for local advanced SCADA operation

Series Selection Comparison Table (Quick reference for retrofit projects)

시리즈Catalog Number수명주기구성 소프트웨어응용 시나리오
PanelView Standard2711단종PanelBuilder32Legacy spare part maintenance (2711-T5A2L1)
PanelView Plus62711피단종FTView MESpare parts for existing installed base
PanelView Plus72711피활동적인FTView ME중간 & large production lines, compatible with legacy FT projects
패널뷰 8002711아르 자형활동적인FTView800✅Legacy DH485 line retrofit, replace 2711-T5A2L1
PanelView50002713P/2715P활동적인Studio5000 View DesignerLarge Logix5000 projects
OptixPanel2800활동적인FactoryTalk Optix새로운 프로젝트, IoT visualization

General Suffix Definition (Rapid model decoding)

T = Touch only; K = Keypad membrane; B = Touch + Keypad combined

C = Color LCD; A=Monochrome

D = 24VDC supply; A=AC100-240V

W = Wide screen; P = Performance high grade

S = Standard grade

Key Project Migration Tips (Continued from your 2711-T5A2L1 migration assessment)

  1. 2711 (PV Standard) → 2711R PanelView800: 추천, supports RS485/DF1 for SLC500/MicroLogix, moderate cost; screens must be reconfigured, PB32 project cannot be imported
  2. 2711 → PanelView Plus7: Also feasible, requires DF1 / serial communication module
  3. 2711 → PanelView5000: Not recommended for legacy DH485 retrofit. Software fully different, extra gateway required for serial port, heavy engineering workload

 

이전:

답장을 남겨주세요

메시지를 남겨주세요