버섯 750330 안전 릴레이

전체 모델: PNOZ s7 C 24VDC 4 아니요 1 n/c Pilz PNOZsigma Series Safety Relay Basic Specifications Order No.: 750330 공급: 24 V DC Safety Contacts: 4 평상시 열려 있음 (아니요) 보조 연락처: 1 평상시 닫혀 있음 (n/c) 너비: 22.5 mm Function: For safety emergency stop, 안전 게이트 모니터링, two-hand control and other safety circuit evaluation Series: ...

  • 제품 세부정보

전체 모델: PNOZ s7 C 24VDC 4 아니요 1 n/c

Pilz PNOZsigma Series 안전 릴레이

기본사양

주문번호: 750330

공급: 24 DC에서

안전 연락처: 4 평상시 열려 있음 (아니요)

보조 연락처: 1 평상시 닫혀 있음 (n/c)

너비: 22.5 mm

기능: For safety emergency stop, 안전 게이트 모니터링, two-hand control and other safety circuit evaluation

시리즈: PNOZ s7 C (C = with cascade interface, for connecting extension modules)

인증: CE, UL, TÜV; Safety Level PL e/SIL 3 (Compliant with ISO 13849-1/IEC 62061)

일반적인 응용 분야

Emergency stop button circuit monitoring

안전 게이트 스위치, 안전 리미트 스위치

Small automation machines, 공작기계, packaging machinery safety control

Can be cascaded with PNOZsigma extension modules (s0, s1, s2, s4, s5, s6, s7, s8, s9) 접점 확장을 위해

Confusing Model Comparison

750107: PNOZ s7 (without C, no cascade function)

750330: PNOZ s7 C (cascade-capable version)

배선 참고 사항

  1. S11/S12: Safety Input Channel 1
  2. S21/S22: Safety Input Channel 2 (Dual-channel monitoring)
  3. 13/14, 23/24, 33/34, 43/44: Four safety normally open outputs
  4. 51/52: Auxiliary normally closed feedback contact
  5. UB/0V: 24V DC 전원 공급 장치

교체 참조

동일 시리즈 교체: Original product is preferred for the same specification; domestic safety relays can be used for functional replacement (PL level, contact configuration and wiring logic must be verified)

치받이: If more contacts are required, cascade with PNOZ s extension modules

추가 정보

보호 등급: IP20 (DIN 레일 장착, 캐비닛 설치 전용)

설치: DIN 35mm 레일

작동 온도: -10 ℃ ~ +55 ℃

버섯 750330 (PNOZ s7 C) 배선 지침 + 문제 해결 체크리스트

Important Precaution: PNOZ s7 C is a contact extension module. It cannot be used as a standalone master module. It must be used with PNOZsigma master safety relays (s1/s2/s4/s5/s6 etc.); C = cascade connector, connected to master module via U-link. It is NOT an independent evaluation unit.

  1. 터미널 정의

A1: 24VDC+

A2: 24VDC-

안전 출력 (Force-guided normally open, 안전회로용)

13-14, 23-24, 33-34, 43-44 (4 sets n/o)

보조 연락처 (Not allowed for safety cut-off circuits, only for PLC feedback/indicator lamps)

51-52 (1 set n/c)

Top side: Cascade slot + Terminator plug

  1. Two Wiring Schemes

계획 1: Cascade with PNOZsigma Master Module (추천, with pulse detection)

  1. Mount master module and s7 C side by side on DIN rail, remove terminator plugs on both modules
  2. Insert PNOZsigma U-link connector; internal safety signals are transmitted from master module to s7C
  3. Master module is powered at A1/A2; s7C A1/A2 also requires separate 24V DC supply
  4. Route outputs 13-14/23-24/33-34/43-44 into contactor coil circuits; a 6A fuse is recommended to prevent contact welding
  5. 51-52 is wired to PLC digital input for status feedback

Cascade Rule: The terminator plug must be fitted on the LAST module of the cascade chain! Fault will be triggered if missing.

계획 2: Hardwired extension for non-sigma series (PNOZ X etc., no U-link)

The safety output contact of the master relay is wired into the s7 C supply loop (master safety contact acts as enable for s7C power supply)

Master contact closed → s7C energized, all safety outputs closed

Master contact open → s7C de-energized, all safety outputs open

⚠️ No internal short-circuit pulse diagnosis in this mode. Safety architecture is downgraded, only for low-risk applications.

  1. 안전 배선 규칙
  2. 맥스. load for safety outputs: ≤6A, 240VAC; fuses are mandatory to avoid contact welding
  3. 51-52 auxiliary contact must not be used for safety cut-off, only for status signals
  4. 케이블: Copper wire with ferrule for cabinet wiring, 스프링 터미널; IP20, no exposed wiring
  5. Emergency stop/safety gate logic is fully configured on the PNOZsigma master module (mode selector, dual-channel detection, auto/manual reset). s7C only follows the output state
  6. Check U-link connection regularly for vibration-prone applications (공작기계, 컨베이어)
  7. LED 표시기 정의 (PNOZ s7C itself)

힘: 24V supply present

밖으로: Safety outputs closed (master module permits output)

잘못: Diagnostic error/fault lockout

IN1, IN2 indicators are located on the master module. The s7C extension module has no input indicators.

  1. 문제 해결 체크리스트 (순서대로)

잘못 1: FAULT LED ON continuously, 출력 없음 (가장 빈번한)

원인 1: Terminator plug missing or not installed on the last module

치료: 전원 끄기, fit terminator plug on the last module’s cascade slot, power on and reset

원인 2: U-link loose or not fully clipped

치료: 전원 끄기, re-seat U-link and confirm locking

원인 3: No supply/reversed polarity/excessive voltage drop on A1/A2

치료: Measure A1-A2 voltage with multimeter, confirm stable 24VDC; check spring terminal loose connections

원인 4: Master module FAULT, wrong mode setting, short circuit on master input channels

치료: Troubleshoot master module first; s7C will only work normally once master is recovered

잘못 2: POWER LED ON, OUT LED OFF, FAULT LED OFF

원인 1: Master safety relay is in safe-off state (E-stop pressed, 안전문이 열려있습니다)

치료: Reset E-stop/close safety gate, confirm master OUT LED lights up

원인 2: Master module set to manual reset and reset button not pressed

원인 3: Wrong cascade order; master module is not the first unit in chain

원인 4 (hardwired mode): Master safety contact damaged/open circuit

잘못 3: Intermittent FAULT trigger, output flickering

원인 1: U-link loose due to cabinet vibration (공작기계, 컨베이어 라인)

원인 2: High ripple/insufficient capacity/frequent dip on 24V power supply

원인 3: Short circuit on output circuit, fuse blown and safety lockout activated

원인 4: Cross-wire/earth short circuit on master module input wiring (pulse detection triggers fault)

잘못 4: FAULT latched, cannot reset after power cycle

원인: Internal safety contact welding (overload/short circuit without fuse protection)

치료: Module cannot be repaired; 직접 교체. Add fuses on output circuits to prevent recurrence.

잘못 5: Master module normal, s7C output out of sync

원인: Poor U-link contact; or welded contact on intermediate contactor in hardwired configuration

  1. Standard Commissioning Procedure
  2. 전원 끄기, mount on DIN rail, wire power supply, fit U-link and terminator plug
  3. Wire master module and set mode selector (adjust selector only when power OFF; changing under power will lock fault)
  4. Verify fuses on all safety output loops
  5. 전원 켜기. Master IN1/IN2 OK, master OUT ON → s7C POWER + OUT ON
  6. 기능 테스트: Trigger E-stop/open gate → master OUT OFF, s7C OUT opens synchronously; reset and confirm synchronous closing
  7. 기록: Safety function verification must be performed after every wiring change or module replacement
  8. Quick Comparison: s7 (750107) vs s7 C (750330)

750107: PNOZ s7, 확대, no C, U-link cascade not supported

750330: PNOZ s7 C, 확대, C version, U-link cascade supported (당신의 모델)

Working Principle of PILZ 750330 (PNOZ s7 C)

핵심 요약: It has no input channels and no safety logic evaluation function. It is a follower-type extension module equipped with force-guided safety contacts. Safety judgement, dual-channel detection and short-circuit pulse diagnosis are all performed by the upstream PNOZsigma master module. The s7 C only synchronously follows the master safety command and feeds back its actual contact status to the master for verification.

중요한: PL e/SIL3 safety rating is determined by the master module. s7 C alone cannot raise the safety level.

  1. Internal Hardware Structure

내부: Two independent safety relays with mechanically linked force-guided contacts, 4 safety normally open outputs + 1 auxiliary normally closed feedback contact

전원공급장치: Independent 24VDC supply on A1/A2 (not powered by master module)

Top U-link port: Dual-channel drive signals + feedback return line, safety link; not ordinary communication bus

Terminator plug: Closing component for the end of cascade chain, used by master module to confirm chain integrity; fault is triggered if removed

  1. Standard Cascade Mode (U-link connection, recommended dual-channel safety architecture)
  2. Master module (s1/s2/s4/s5/s6 etc.) collects E-stop and safety gate signals, performs dual-channel comparison, cross-line short-circuit pulse detection and reset logic
  3. When safety conditions are satisfied, master sends synchronized dual-channel drive signals to s7 C via U-link
  4. s7 C receives valid drive signals → internal two safety relays pull in simultaneously, 13-14, 23-24, 33-34, 43-44 four safety contacts close
  5. Critical safety closed-loop: The actual contact state of s7 C is sent back to master module via cascade lines

Master continuously compares: issued command vs real feedback contact status

Matched: 정상 작동

Mismatched (접촉 용접, failure to act, 단선, loose U-link): Master cuts drive immediately, whole safety chain locks FAULT, safety contacts force open

  1. Once safety trip condition occurs (E-stop pressed, 안전문이 열렸습니다): Master stops drive signal → s7C relays de-energize, all safety contacts open; status feedback is sent back to master for verification

This bidirectional verification is the core of force-guided contact + feedback monitoring, preventing dangerous failure mode where contacts remain conductive after open command due to welding.

  1. Hardwired Mode (without U-link, downgraded single-channel)

Master safety output contact is wired into s7C supply enable loop:

Master contact closed → s7C energized, outputs closed

Master contact open → s7C de-energized, 출력 개방

⚠️ Defect: No dual-channel feedback. Master cannot diagnose internal faults of s7C. Safety architecture no longer meets PL e, only for low-risk applications.

  1. LED Logic

힘: A1/A2 24V supply OK

밖으로: Valid drive signal received from master, safety contacts closed

잘못: Master detects chain anomaly (loose U-link, missing terminator, inconsistent feedback, broken cascade line), safety lockout activated

  1. Diagnosis Principle (Why missing terminator triggers FAULT)

The whole cascade chain forms a serial closed diagnostic loop: Master → s7C1 → s7C2 → … → terminator plug on last module.

Master continuously sends diagnostic pulses scanning the whole chain. The terminator acts as an end termination resistor to close the pulse circuit.

Plug removed → pulse circuit open → master detects broken chain and locks FAULT to prevent uncontrolled extension module behaviour.

  1. Function Division: Master vs s7 C

마스터 모듈:

Connect E-stop/safety gate inputs

Dual-channel detection, cross-wire short-circuit detection, reset logic

Send drive commands + receive feedback and fault judgement from all extension modules

PNOZ s7 C (750330):

No input terminals, cannot connect E-stop

행동: Pull in/open safety contacts synchronously

Feed back real contact status continuously to master for verification

Only increases available safety contacts, no safety logic evaluation

  1. Core Safety Design

Internal relays adopt mechanical force-guided structure: If one relay contact welds closed, the mechanical coupling ensures the other contact opens reliably. This anomaly is fed back to master and triggers fault lockout, avoiding dangerous “command open but contact conductive” failure.

Pilz PNOZ Safety Relay Order List

메모: PNOZsigma (750xxx/751xxx) is current mainstream series; PNOZ X (774xxx /777xxx /787xxx) is legacy classic series; PNOZmulti2 is programmable safety controller. s7 C (750330) is sigma contact extension module and cannot be used standalone.

약어: n/o=normally open, n/c=normally closed, n/o t=delayed-off normally open, SC=semi-conductor output

  1. PNOZsigma Series (24VDC, 우선의, PL e/SIL3)

Standalone Master Modules (can work alone for E-stop/safety gate)

주문 번호.전체 모델문의 사양너비비고
750101PNOZ s1 24VDC 2n/o2아니요12.5mm단일 채널, 기초적인
750102PNOZ s2 24VDC 3n/o 1n/c3아니요+1NC17.5mm단일 채널
750103PNOZ s3 24VDC 2n/o2아니요17.5mmDual-channel short-circuit detection
751103PNOZ s3 C 24VDC 2n/o2아니요17.5mmCascade C version
750104PNOZ s4 24VDC 3n/o 1n/c3아니요+1NC22.5mm듀얼 채널, 널리 사용되는
750105PNOZ s5 24VDC 2n/o 2n/o t2NO+2 delayed NO22.5mmDelay-off type
750106PNOZ s6 24VDC 3n/o 1n/c3아니요+1NC22.5mmTwo-hand control dedicated
750107PNOZ s7 24VDC 4n/o 1n/c4아니요+1NC22.5mm확대, no U-link cascade
750330PNOZ s7 C 24VDC 4n/o 1n/c4아니요+1NC22.5mmCascade C version, U-link compatible (당신의 모델)
750108PNOZ s8 24VDC 2n/o2아니요12.5mmSmall contact extension
750109PNOZ s9 24VDC 3n/o3아니요17.5mmContact extension
750110PNOZ s10 24VDC 2n/o2아니요12.5mmDual-channel light curtain
750111PNOZ s11 24VDC 4n/o4아니요22.5mm듀얼 채널
750124PNOZ s4.1 24VDC3아니요+1NC22.5mmSpecial reset mode
750126PNOZ s6.1 24VDC3아니요+1NC22.5mmImproved two-hand control
750150PNOZ s20 24VDCSemi-conductor output12.5mmPure semiconductor
750151PNOZ s22 24VDCSemi-conductor output17.5mmLight curtain dedicated
750130PNOZ s30 24VDC2NO+2 delayed NO22.5mm긴 지연
750152PNOZ s50 24VDCSemi-conductor22.5mmSemi-conductor safety output

Sigma Accessories

주문 번호.설명
750008PNOZsigma U-link Cascade Connector
750009Terminator Plug (mandatory at end of chain)
  1. PNOZ X Legacy Series (AC/DC 범용, for replacement of existing projects)

Basic E-stop/Safety Gate Models

주문 번호.모델콘택트 렌즈공급
777303PNOZ X2P2아니요24VAC/DC
787059PNOZ X7P C2아니요24VAC/DC
774053PNOZ X72아니요110VAC
774055PNOZ X72아니요120VAC
774057PNOZ X72아니요240VAC
787100PNOZ X1P C3아니요+1NC24VDC
787310PNOZ X3P C3아니요+1NC24VAC/DC
774729PNOZ X63아니요24VAC/DC
774080PNOSIS 117아니요+1NC24VAC/DC
774006PNOSIS 106아니요+4NC230-240VAC

Delay-off XV Series

주문 번호.모델콘택트 렌즈지연 범위
777510PNOZ XV3P 303NO+2 delayed NO0.1~30초
774610PNOZ XV3.1 303NO+1NC+2 delayed NO0.1~30초
774618PNOZ XV3.1 3003NO+1NC+2 delayed NO0.3~300s

Two-hand Control P2HZ Series

주문 번호.모델콘택트 렌즈
777340P2HZ X1P3NO+1NC+2SC
774350P2HZ X32아니요+1NC
774360P1HZ X12아니요

Contact Extension PZE Series (for PNOZ X master)

주문 번호.모델콘택트 렌즈
774580PZE X44아니요
777580PZE X4P4아니요
774590PZE X55아니요
777600PZE 9P7아니요+2NC
  1. PNOZ멀티 2 Programmable Safety Controllers (Large machines, multi safety functions)
주문 번호.모델설명
772100PNOZ I B0기본 유닛, 확장 가능
772104PNOZ I B0.1B0 upgraded version
772105PNOZ m C0콤팩트, 확장 불가능
772138PNOZ m ES ETH이더넷 통신 모듈
  1. 빠른 선택 가이드
  2. 750xxx = PNOZsigma new series; 750xxx without C = standalone/hardwired extension; 751xxx /7503xx with C = U-link cascade supported
  3. 774/777/787xxx = PNOZ X legacy series, for spare replacement only, 새로운 프로젝트에는 권장되지 않습니다
  4. 772xxx = PNOZmulti2 programmable safety controller (not simple safety relay)
  5. s7 (750107) and s7C (750330) are both extension modules, cannot connect E-stop independently, must pair with sigma master
  6. Confusing Model Reference

750107: PNOZ s7, 확대, no C, U-link cascade not supported

750330: PNOZ s7 C, 확대, C version, U-link cascade supported