GV2P21
GV2: TeSys GV2 series 모터 회로 차단기
피: Rotary handle version (high-performance variant, distinct from push-button GV2ME; independent UL508 Type F certification, 더 높은 차단 용량)
21: Current rating code → 17~23 A
Distinction Tip: GV2ME21 also covers 17–23 A, but adopts push-button operation; GV2P21 features a green rotary handle. Direct mechanical interchange is not allowed.
- 핵심 전기 매개변수
| 매개변수 항목 | 기술 사양 |
| 극 수 | 3P thermal-magnetic trip |
| Thermal trip adjustment range | 17~23 A (수업 10, ambient temperature compensated) |
| Instantaneous magnetic trip current | 327 에이 (단락 보호) |
| 정격 사용 전압 Ue | AC ≤690 V, 50/60 헤르츠 |
| 정격절연전압 Ui | 690 다섯; Rated impulse withstand voltage Uimp=6 kV |
| 활용 카테고리 | AC-3 (motor switching), IEC 60947-2 / IEC 60947-4-1 |
| Applicable motor power (3-위상 400V) | 9 kW |
| Ultimate short-circuit breaking capacity Icu (400다섯) | 50 그만큼 |
| 터미널 | Screw-type EverLink terminals; conductor cross-section 1~6 mm²; 조임 토크 1.7 N·m |
- 기계 & 환경 매개변수
전체 치수: W45 mm × H89 mm × D97 mm
설치: 기준 35 mm DIN 레일; alternatively fixed via M4 screws on panel
보호등급: IP20 (손가락 안전 터미널)
작동 온도: -25 ℃ ~ +60 ℃; 보관온도: -40 ℃~+80 ℃
기계적 내구성: ≥100,000 작업; Electrical endurance AC-3 ≥100,000 operations
특징: Built-in phase loss protection; integrated TEST button; padlockable in OFF position; clear tripping status indication
- 터미널 정의
Line side (power input): 1L1, 3L2, 5L3
Load side (motor output): 2T1, 4T2, 6T3
- 옵션 액세서리 (Ordered Separately)
- Auxiliary contact blocks: GV2AN11 (1아니요+1NC), GV2AN20 / GV2AN02
- Fault signal contact: GV2AD10 (trip-specific contact, distinguishes overload and short-circuit tripping)
- Undervoltage release GV2AU, Shunt trip release GV2AS
- Busbar connectors, terminal shrouds, external extended rotary handle
- 선택 & 교체 솔루션
✅ Direct same-series replacement
GV2P21 (회전식 핸들, 17~23A); Do not mistakenly adopt GV2ME21 (push-button variant with different mechanism)
⚠️ Cross-series upgrade alternative
TeSys GV3P25 (overlapping current range, larger overall size; cabinet installation space must be verified)
- Selection Pitfall Guidelines
- The adjustment dial must be set to the motor rated full-load current (FLC); avoid long-term operation near the upper limit;
- 수업 10 trip characteristic: standard motor startup protection; use cautiously for heavy-duty frequent startup conditions;
- GV2P integrates overload and short-circuit protection. Fuses at upstream can be omitted for single small motors. Upstream short-circuit protection coordination is required for high-power systems;
- Vertical installation is mandatory; reserve heat dissipation space around devices. Avoid overheating and false tripping caused by dense side-by-side mounting;
- Built-in phase loss protection, recommended for 3-phase motors; direct application for single-phase motors is not advised.
- 일반적인 애플리케이션 시나리오
3-위상 비동기 모터 (rated current 17~23A) 워터 펌프와 같은, 팬, 컨베이어, small air compressors and machine tool motors; control cabinets for automated production lines, HVAC and packaging machinery.
Full Comparison: GV2ME21 VS GV2P21
Common features: 17~23 A adjustment range, 3P thermal-magnetic trip, 수업 10, 위상 손실 보호, identical terminal layout, DIN 레일 장착, interchangeable auxiliary contacts (GV2AN11/GV2AD10); 초과 적재 & short-circuit protection thresholds are exactly the same.
- 핵심 비교표
| 비교항목 | GV2ME21 (ME=Push-button Type) | GV2P21 (P=Rotary Handle Type) |
| 작동 메커니즘 | Red STOP button + Black START button; | Green rotary handle; |
| Red button pops out upon fault tripping | Handle stays at intermediate TRIP position after tripping | |
| Reset Logic | 넘어진 후, reset and close circuit directly by pressing the red STOP button | 넘어진 후, must rotate back to OFF position before re-closing (mandatory reset) |
| Visible Isolation | No defined visible isolation marking | OFF position meets visible isolation requirements, can act as disconnector under certain conditions |
| Ultimate short-circuit breaking capacity Icu @400V | 10 그만큼 | 50 그만큼 (significant advantage) |
| UL508 Certification Type | Type E | F형 (critical for North American projects) |
| Extended Cabinet Handle | Cannot be fitted with external rotary operating accessory | Supports matching external extended rotary handle for cabinet door operation |
| Padlocking Function | Unable to lock the OFF position | Direct padlocking available in OFF position for safety lockout |
| 전체 치수 | W45×H89×D97mm | W45×H89×D97mm (same dimension, not mechanically interchangeable) |
| 가격 | 낮추다 | 약간 높음 |
- Detailed Interpretation
2.1 작동 모드 & Safety Logic (Most Intuitive Difference)
GV2ME21: Push-button Start/Stop
Press black START to close; press red STOP to open.
After motor overload/short-circuit trip, red button pops out. Circuit can be reset directly by pressing the red STOP button.
✅ Suitable for: Local operation inside control cabinets, general fans & 물 펌프, standard domestic automation equipment.
GV2P21: Rotary Handle Operation
Rotate clockwise → ON (닫은); Rotate counterclockwise → OFF (열려 있는).
Upon fault tripping, handle locks at intermediate TRIP position; Mandatory rule: rotate back to OFF before closing again, preventing forced power-on before fault elimination.
✅ Suitable for: Equipment maintenance safety management, 유럽 사람 & overseas exported machines, applications requiring Lockout/Tagout (마음), cabinet door external operation.
2.2 단락 차단 용량 (Key Engineering Selection Factor)
GV2ME21: Icu=10 kA @400V
GV2P21: Icu=50 kA @400V
If prospective short-circuit current of upstream power supply exceeds 10 그만큼, GV2ME21 is strictly prohibited; GV2P21 must be selected, otherwise the circuit breaker risks rupture under short-circuit conditions.
2.3 Accessory Compatibility Reminder
Side-mounted auxiliary contacts, fault contacts, shunt/undervoltage releases are electrically interchangeable;
Front-panel accessories are NOT interchangeable: extended cabinet handle only compatible with GV2P, unavailable for GV2ME;
⚠️ Cannot directly replace each other despite identical mounting dimensions!
Different internal mechanisms lead to inconsistent panel cutout and interlock logic; drawing revision and re-verification are required.
- 선택 추천
✅ Choose GV2ME21
- General domestic control cabinets, system short-circuit current ≤10 kA;
- Only local operation inside cabinet, no padlocking or external door operation required;
- Cost-sensitive projects with no mandatory UL Type F requirement for North America.
✅ Choose GV2P21
- 시스템 단락 전류 >10 그만큼;
- 잠금/태그아웃 (마음) required for maintenance; need external cabinet handle;
- 장비 수출, overseas projects (EU, 동남아시아, 북아메리카);
- Process requirement: manual reset to OFF before reclosure after trip, to avoid accidental equipment startup.
Application Scenario Breakdown: GV2ME21 vs GV2P21
Core hardware boundary recap:
GV2ME21: 푸시 버튼 | Icu=10kA @400V
GV2P21: 회전식 핸들 | Icu=50kA @400V, supports LOTO padlocking, visible isolation & extended external handle
Both share identical thermal trip range 17~23A and motor protection curves. Application differences are determined by safety specifications, short-circuit capacity and operation requirements.
- Preferred Application Scenarios for GV2ME21 (Push-button Type)
✅ Recommended Scenarios
- General domestic civil & light industrial control cabinets, prospective short-circuit current ≤10 kA
Ordinary fans, standard water pumps, 소형 컨베이어, dust removal fans, auxiliary machine motors for machine tools; systems far from distribution transformers with low short-circuit current.
- Circuit breaker only used for internal cabinet protection, no external cabinet operation required
No need for external operating mechanism; operators only open cabinet door for operation.
- Workshop without strict mandatory LOTO lockout/tagout regulations
Loose maintenance management with no compulsory safety locking specifications.
- Economical standard complete equipment, mass general machinery with cost control priority
포장 기계, 소규모 생산 라인, HVAC terminal equipment.
- Short-cycle repeated startup, scenarios requiring rapid reset after tripping
Red button pops after trip; reset simply by pressing STOP for convenient operation.
❌ Forbidden Scenarios
- Outgoing circuits close to transformers, busbar short-circuit current >10 그만큼;
- EU/North America export machines, projects requiring visible isolation and LOTO safety locking;
- Need to install extended external cabinet operating handle;
- 방폭 지역, 중장비, high-risk production machinery.
- Preferred Application Scenarios for GV2P21 (Rotary Handle Type)
✅ Recommended Scenarios
- 시스템 단락 전류 >10 그만큼 (Primary hard selection criterion)
Distribution rooms adjacent to transformers, large-capacity busbars, power center feeder circuits with high short-circuit current requiring enhanced breaking capacity.
- 잠금/태그아웃 (마음) safety locking requirement for maintenance
Production line maintenance, stamping equipment, 컨베이어, auxiliary hoisting mechanisms, 화학적인 & 식품 기계; padlockable in OFF position to prevent accidental closing, compliant with OSHA and GB safety standards.
- External cabinet door operation (with optional extended rotary handle)
Start/stop and open/close without opening cabinet doors, delivering better human-machine operability.
- Export machinery & overseas projects (EU, 동남아시아, 북아메리카)
Compliant with UL508 Type F and IEC visible isolation requirements; overseas acceptance standards generally prefer rotary-operated motor circuit breakers.
- High-risk loads to prevent blind restart after fault
Handle stays at TRIP mid-position after tripping; must turn back to OFF before closing; eliminate risk of restarting before fault troubleshooting. Suitable for mixers, crushers and hydraulic station motors.
- Application as circuit isolating device
OFF position provides visible isolation gap; a separate disconnector can be omitted in some drawings.
❌ 권장되지 않는 시나리오
Extremely tight budget, low short-circuit current, no special safety specifications, purely cost-driven simple equipment.
- Quick Selection Table by Operating Conditions
| 작동 조건 | 추천 모델 | 이유 |
| Far from transformer, Isc ≤10kA, ordinary fans & 슬리퍼, domestic standard equipment | GV2ME21 | Lower cost and sufficient performance |
| Close to distribution transformer, prospective short-circuit current >10그만큼 | GV2P21 | Breaking capacity satisfies short-circuit protection and avoids burnout risk |
| Production line maintenance requiring mandatory LOTO lockout | GV2P21 | Padlockable, meets safety codes |
| Need to operate circuit breaker externally on cabinet door | GV2P21 | Compatible with extended handle, unavailable for GV2ME |
| Complete machine for export | GV2P21 | Compliant with overseas electrical acceptance specifications |
| 분쇄기, mixers and other hazardous loads to avoid accidental restart | GV2P21 | Mandatory OFF reset after trip for higher safety margin |
| Simple HVAC, standalone unit with no special safety requirements | GV2ME21 | Economical solution |
- Common Engineering Misunderstandings Reminder
- Do not interchange simply based on identical current rating
Even with same 17~23A setting, replacing GV2P21 with GV2ME21 will create severe short-circuit hazard if on-site short-circuit current exceeds 10 그만큼.
- Common practice among panel builders: GV2ME series for HVAC; GV2P series for industrial production lines, power cabinets and export equipment.
- 보조 접점 (GV2AN11/GV2AD10) are electrically interchangeable, yet front operating mechanisms differ; cabinet panel cutouts cannot be modified for direct replacement.
접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지